HomeMy WebLinkAboutProduct Approval (2) MIAIWI•®ADE;' MIAMI-DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315t2599 _NOTICE OF ACCEPTANCE (NOA) www.miamidad .Eov/economy Lawson Industries,Inc. 8501 N-IN 90 Street Medley, FL 33166 SCOpF4 This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and,other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section(In Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the,AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been-designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone.- DESCRIPTION: Series"SH-7700(Flange Frame)"Aluminum Single rung Window—L.MT .I. APPROVAL DOCUMENT: Drawing No. L7700-0901, titled "Series-7700 Single Hung Flange Frame Impact Window", sheets 1 through 5 of 5, dated 05/27/09, with revision D dated 11/01/17, prepared by manufacturer, signed and sealed by Thomas J. Sotos,P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small rvlissile Impact Resistant Dff ATIONS: Insulated Glazing Options Types 6 and 7 are not approved to be installed above 30 feet in height without external protection device(shutters) LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMY-NATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with-any section of this NOA shall be cause for termination and removal of NOA. T ADVERTiiSE1VIE1`.'T: The NOA number receded b the words Miami-Dade County, Florida, and P Y tY� followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be.available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.16-1003.01 and consists of this page I and evidence pages E-1 and E-2,as well as approval document mentioned above. The submitted documentation was reviewed by'Sifang Zhao,P.E. �. �I.M-11011 ERWYK- , �.�• NOA N®.17-1212.21 Expiration Date: December 27,2021 Approval Date: February 01,2018 Page 1 File COPY Lawson Industries,Inc. NOTICE OF ACCEPTANCE: E ENCE SUBMITIED A. DRAW iGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 09-0706.09) 2. Drawing No. L 7700-0901, titled `Series-7700 Single Hung Flange Frame Impac' Window', sheets 1 through 5 of 5, dated 05/27/09 with revision D dated 11/01/17, prepared by manufacturer, and signed and sealed by Thomas J. Sotos,P.E. B. TESTS 1. Test reports on: 1)Uniform Static Air Pressure Test, Loading.per FBC,TAS 202-94 2)Large Missile Impact Test per FBC,TAS 22 W-941 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along wiin marked up drawings and installation diaagram of an aluminum single hung window, prepared by I-Iurri,cane Engineering.& Testing,Inc., Test Reports No.HETI- 0'9;ZraOA and JILIETI-09 2530B, dated 03/02/09, signed and sealed by Candido F. Font,P.E. (Submitted under IVOANo. 09-0766.09) 2. Test reports on: 1)Uniform.Static Aft-Pressure Test,Loading per FBC TAS 202-94 2)Large Mis-H-le lmgaet Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 2-03-94 along with marked-up drawings and installation diagram of an aluminum single hung window, prepared by Hurricane Engineering & Testing, Inc., all Test Reports No. BETai-08-2003C, 1ETI-08-2004A, =1 -08-2060A & D, HETI-08-2061A & B, HEE e'I;-08-2062A & B, 11TEE TI-08 2Ob3A.&.B,-IIETI-08-2064A.& B,dated 03 15/08, signed and sealed by Candido F. Font P.E. (Submitted under NOA No. 08-08.25.I7) 3. Test reports on: 1)Air Infiltration Test,per FBC,TAS 202-94 2)Unifonn Static Ayr Pressure Test,Loading-per FBC TAS 202-94 3)'WaterJZesistance TesL per FBC,TAS 202r94 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test,per FBC 2411 3.2.1, TAS 202-94 along with marked up drawings and installation diagram of an aluminum single hung window, prepared b=y Fenestration Testing Laboratory,. Inc., Test Reports No. FT L- 2987 and 'L-2986, dated 04/03/01 and 03/27/01, all- signed .and sealed by Luis Antonio Figueredo,.P.E. (Submitted under IVOA No. 0I-1609.01) -C. CALCULATIONS 1. Anchor ver=.fication-calculations.and structural analysis, complying with FBC, prepared by Lawson industries,Inc.,dated 05/2&/09,revised on 01/19/10, signed and sealed by Thomas I Sotos,P.E. ("Submitted under NO-4 No. 11-0705 09) 2. Glazing complies wiffi ASTM E1.00=09 Sifang Zha.o,P.E. product Control Examiner NOA No.17-1212.21 Expiration Date. Deceaber?7,2021 Approval lDa:ate: February 01,20I8 E-1 Lawson Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-0808.02 issued to Kuraray America,Inc.for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America,Inc. for their "Trosifol®Ultraclear, Clear and Color PVB Interlayers"dated 01/19/17, expiring on 07/08/19. 3. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company(MA) for'their"Safiex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBI' -6th Edition. (2017), and of no financial interest, dated November 17, 2017, issued by manufacturer, signed and sealed by Thomas J. Sotos,P.E_ 2. Statement letter of no financial interest, dated 05/28,09, issued by manufacturer, signed and sealed by Thomas J. Sotos, P.E. (Submitted under NO-4 No. 11-0705.09) 3. Laboratory compliance letter for all Test Reports No. BETI-09-2530A& B,issued by Hurricane Engineering&Testing,Inc., dated 03/02/09,signed and sealed by Candido F.Font, P.E. (Submitted tinder NOA No. 09-0706.09) 4. Laboratory compliance letter for Test Reports No. HETI-08-2003.C,HETI-08- 2004A,HETI-08-2060A& B,IIETI-08-2.061A& B,HETI-08-2062A& B, HETI-08-2063A &B,HETI=08-2064A&B,issued by Hurricane Engineering& Testing,Inc., dated 03/1.5/08,signed and sealed by Candido F.Font,P.E. (Submitted tinder NOA No. 08-0825.17)- _. 5. Laboratory compliance letter-for Test Reports No. FTL-2987 and FTL-2986, issued by Fenestration Testing Laboratory, Inc., dated 04/03/01 and 03/27/01, signed and sealed by Luis Antonio Figueredo,P.E. (Submitted under NOA No. 01-0406 08) G. OTHERS 1. Notice of Acceptance No. 16-1003.01,issued to Lawson Industries,Inc. for their Series"SH-7700 (Flan,Frame)"Aluminum Single Bung VVindow—L.M.I.", approved on 12/15/16 and expiring on 12/27/21. ;, Sifang Zhao,P.E. Product Contr Ol Examiner NOA No. 17-1212.21 Expiration Date: December 27,2021 Approval Date. February 01,2019 E-2 48' 53.125 53.125' INSTALLATION A"HORSi WINDOW FLANGE FRAME WIDTH WINDOW FLANGE FRAME WIDTH INSTALLATION ANCHORS WINDOW FLANGE FRAME WIDTH V7 .. (A)4 NAX AT FRANE HEAD 7NSTALLAT20N ANCHORS W 4 HA%.AT FRAME HEAD (D)NONE PER FRAME SILL — 13 3/4• (A)4 MA%.AT FRAME HEAD 10 I5/I6.1.-A� fH)NONE PER FRAME SILL — 13 3/4' O Q (C)FRAME JANBS(SEE SHEET P4) �{ I MAX,O.C.l, (B)NONE PER FRAME SILL MAX.O.C.FK <C)FRAME JANBS(SEE SHEET 04) {� I MAX.O.C. b• C5 ( t AIL) (C)FRAME JAMBS(SEE SHEET 64) (p 4 z' 6- BANE 6. ALL CORNERS _ .. « ALL CORNERS i L n I F Max. D.L.O.Widtn ALL CORNERS I V U =i;43 9 16 ;f =o_ m p N O O ICI 10 1/4' '____ -'i- ;d=- a i� %/;; e' 3 b MAX.ABOVE V/ ! n � t ii ii G 0 pf;h W 14MOABOVk. MEETING RAILS „ x 10 3/ib' D FF Yr u w o p , •Z -z B ii ii i aw z> MEETING RYAI�is Mox.b.L.O.Width ' _s M�' D.L.O.W th x m a Ga., z u5 _ p 11 16 a k a c-A i 48 11 10,i N x lz O Co u w AT b'MEETING 'J 4 B II II Cim �zla' yj it B ii �� j �' O 61'MEETING = a i d V F o i1 rn in �q ao 6•MEEETING o-a� i� , i� •_ 5 m RAILS a 5 x RAILS x F7 �/ e 1/r > 9 J/8' N gx �> MAX.BELOW10 3/4' / ,/ k cy MAX.BELOW -�/i b HEFTING RAILS == IMA% BELOW_ ,'cif. B.,cZ•- U MEETING RAIL / / p_II --/J,1 O x M R L J,1!!i /J .y �y sF', .z�- U] ocso ® w 6 b 6,NA%. 6NA%. `MAX ��ll W I (` I �' E%T.I.INT.FALSE COLONIAL r' N U] EXT.4 INT.FALSE COLONIAL 52125' MUNTINS ARE APPLIED W/ 5?.I25• A�Ia? a' MUNTINS ARE APPLIED V/ 47.000' W/SILICONE AND ARE •'+ "� O VIN➢OV BUCK O.T.V WINDOW BUCK VmTX WINDOW BUCK WIDTH U P. W/SILICONE AND ARE AVAILABLE AS OPTIONAL. 6 AVAILABLE AS OPTIONAL. 48" x 78" EQUAL LITE ELEVATION UN-EQUAL LITE RADIUS ELEVATION UN-EQUAL LITE ELEVATION N i. •INCLUDES UN-EQUAL LITE AND RADIUS HEAD (LIMITED TO LOADS ON SHEET 4 OF 6) (LIMITED TO LOADS ON SHEET 4 OF 6) D I k (LIMITED TO LOADS ON SHEET 4 OF 6) SERIES-7700 SINGLE HUNG IMPACT WINDOW - FLANGE FRAME Q w General Notes: �z w 1.) THIS WINDOW SYSTEM IS DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS 53125- Fi OF THE FLORIDA BUILDING CODE (2014-6th Edition & 2017-6th Edition) INCLUDING INSTAL I N ANCHORS WINDOW FLANGE FRAME WIDTH d HIGH VELOCITY HURRICANE ZONE VELOCITY HVHZ AND ASTM 1300-09. (Al 4 MA%.AT FRAME HEAD ( ) (B)NONE PER FRAME SILL -•� 13 3/4' THIS PRODUCT IS IMPACT RESISTANT. (SHUTTERS NOT REQUIRED) (C)FRAME JAMBS(SEE SHEET Y4) !MA)L O.c.l m�� 2.) WOOD BUCKS SHALL BE INSTALLED AND ANCHORED SO THAT THE BUILDING A 1 (E (HAx. m 'N' •I,,c RESISTS THE SUPERIMPOSED LOADS IN ACCORDANCE WITH THE REQUIREMENTS TWICAL OF THE F.B.C. & TO BE REVIEWED BY BUILDING OFFICIAL. 6• CORNERS c S e�o 3.) ANCHORS SHOWN ABOVE ARE AS PER TEST UNITS. ANCHORS ON ALL WINDOW SIZES ARE NOT TO EXCEED THESE MAXIMUM SPACINGS ON CENTER (O.C.) AND AS TABULATED ON SHEET 4. ' �' 11 4.) ANCHOR CONDITIONS NOT DESCRIBED IN THESE DRAWINGS ARE TO BE .H 9 5/B• _____=* -'f =?= n $ N ENGINEERED ON A SITE SPECIFIC BASIS, UNDER SEPARATE APPROVAL AND �6 w IMAM%.AB�RV�E ✓� % �� D s d gA s TO BE REVIEWED BY BUILDING OFFICIAL. W< a x a 5.) WINDOWS ARE QUALIFIED FOR USE WITH SINGLE GLAZE LAMINATED GLASS z ii B ii w d -p"6 TYPES TABULATED HEREIN (SEE SHEET #3), AND FOR USE WITH DOUBLE GLAZE _ `a'> 1 AT t" s 8 LAMINATED INSULATED GLASS TYPES TABULATED HEREIN (SEE SHEET#3). dw 6'REETING .��'. 6.) SEE SHEET 9 FOR LOCK DETAILS & OPTIONS. RAILSd, r �] 7.) SEE SHEET 4 FOR DESIGN PRESSURES AND GLASS TYPES. 6.) FOR OPTIONAL FRAME INSTALLATION DETAILS SEE SHEET 3. $n �(+' IE / '� =1° 4e).iS 2E!:Op$B 9.) EXT. & INT. FALSE COLONIAL MUNTINS ARE OPTIONAL&AND ARE APPLIED W/ SILICONE as>�xy u9MAX.BELOW v MEETING RAILS yw '•0�.•e.oe.....,•/���f✓♦♦s 10.) WOOD BUCKS IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED AND ANCHORED �' /1/ I d (BY OTHERS), PRIOR TO WINDOW INSTALLATION. (SEE SHEET #2 FOR DETAIL & NOTES) �� o�jWi��• LL G 0 o PH(1DUCTRRVISEp La WOOD RUCKS TO BE ANCHORED IN COMPLIANCE WITH TID; FBC CHAPTER 24, " " as cum 1,;o F'o V•J; P1 8with(he Florida 40 ;GJ +1 SECTIONDuildinBCode ;O`S' W 11.) APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE MULLED UNITS. Ham' Acceptance No 2 •.al _?t ;u] f- o m 2 - 12.) MULLING SINGLE HUNG WINDOWS WITH OTHER TYPES OF MIAMI-DADE COUNTY APPROVED Expimuon Uwe 1 Zt L j ���`3'•t•f y 'Jp"'"� WINDOWS USING A MIAMI-DADE COUNTY APPROVED MULLION IN BETWEEN ARE ACCEPTABLE EXT.4 INT.FALSE COLONIAL Dy xox°�°� y , BUT THE LOWER DESIGN PRESSURE FROM THE WINDOWS OR MULLION APPROVAL WILL APPLY MUNTINS ARE APPLIED W/ 52.125• MIHmi DDdc Ihodun Cot((roi C-•"• ' _ , V/SILICONE AND ARE o ''♦e A( '• •' TO THE ENTIRE MULLED SYSTEM. AVAILABLE AS OPTIONAL. WINDOW BUCK WIDTH K 13.) SEE SHEET# 3 FOR MULLION/METAL ATTACHMENT DETAILS & OPTIONS. EQUAL LITE ELEVATION 14.) ALL METAL/STEEL IN CONTACT WITH ALUMINUM OR OTHER DISSIMILAR MATERIALS TO BE 99igi6 F PAINTED OR PLATED AND SHALL MEET THE FLORIDA BLDG. CODE. (LIMITED To LOADS ON SHEET 4 OF 5) ¢� 1/4' TAPCON W/ 1 1/4• 014 S.M.S.W/1 1/4'. MIN, EMBEDMENT INTO CONC. ALL WOOD BUCKS ENGINEERED SEPARATELY MIN.EMBEDMENT INTO WOOD. - .PT.W000 BUCKS 4 TO BE REVIEWED BY BLDG. OFFICIAL(TYP.) LA MATED GLASS (SEE ELEVATION AT SHEET IFS (SEE ELEVATION A7 SHEET a1 24 ca FOR MAX. FASTENER SPACING) P.T W013D BUCK NOT BY LAWSON IND. FOR MAX FASTENER SPACING) a A MUST SUSTAIN IMPOSED LOADS SILICONE ADHESIVE CD I 1/B•MIN. 23 BED➢ING COMPOUND in q z D e INTERIOR 2 20 1/4'TAPCON W/l 1/4' n pl y E }} ° MIN.EMBEDMENT INTO CONC. .o ee n •;e•I. ?•'•.a' ,.•. 1 3 4•MIN. : °' 1B "'(SEE ELEVATION AT SHEET 01 N a O1 •a U r~ °a'♦ . 'EMBEDMENT. d: o ' . '' FOR MAX.FASTENER SPACING) w W a...: . o y �ADE"; i z 1 1/4' MIN. 12 - 12 1 1/4'MIN. z [.B w'EMBEDMENT'.,•:. 1 1/8' MIN, M 0. Gu (nE%7ERIOR G a --- ---- ------ - EDGE DISTANCE r4 o PERIMETER CAULKING o C.h p Ot 16 I 19 O 3 _ SILICONE ADHESIVE EXT. cRAOE EXTERIOR J:�:.• 'e...•w .7 CAU BEDDING COMPOUND LK ^' y EXTERIOR GRADE f"+'t2.?:��;�r-"„ U `C z p yyk PERIMETER CAULKING �J, �9 LAMINATED GLASS WINDOW FRAFfE WIDTH ®N 3'MIN. 0 14 S.M.S.W/1 1/4' I'MIN_ W A _ Ge DISTANCI MIN.EMBEDMENT INTO WOOD. DGE DISTANC� WINDOW INSTALLATION NOTES: A N INTERIOR (SEE ELEVATION AT SHEET#I 1. THE WINDOW FRAME FLANGE TO BE BACK-BEDDED W/ AN EXT, f`��•1�1 MEETING FOR MAX.FASTENER SPACING) W RAILS 18 GRADE CAULK THROUGHOUT THE ENTIRE PERIMETER OF FLANGE H EXTERIOR EXT. GRADE EXT. GRADE I BY WINDOW INSTALLER (TYP.) CAULK CAULK 2. THE EXPOSED EXT. PERIMETER OF THE WINDOW FRAME TO O 1 1 4'MIN, BE SEALED W/ AN APPROVED EXTERIOR GRADE CAULK O EMBEDMENT BY OTHERS (TYP.) 4 4 g 5WHEN THErn BETWEEN THE WINDOW FRAME AND THE BUCK OR Q PA o MASONRY IS LESS THAN 1/8", SHIMS ARE NOT REQUIRED. H •2 trJ I ANCHORS NOTE: ' 28 e I 17 ANCHORS TO BE #12 SMS OR WD. SCREWS INTO WOOD, OR 1 1 1/4' TAPCONS or APPROVED CONC. FASTENERS INTO CONC., S 1 WITH A MINIMUM OF 1 1/4' PENETRATION INTO WOOD OR �s I 1H CONC. (REFER TO LOAD TABLES AT SHEET 4 OF 5 FOR � �• QUANTITIES REQUIRED) I � s s s E 6 25 16 ; o 21 oP 28 i A E # 2 z o 6 28 ' �rc z c4� rc 16 z°•( m J`o © i 11 14 O N. ly}�� ILJ_41_LJI I 11 � 14 EXTERIDR GRADE I 2 PERIMETER CAULKING LJ 2 1/4' MAX. SHIM •.rR1, a <` a's• — . TYP ..... PRODUCT REVISED R. 'Q• •••IL 6�?✓�i ........... ........ A d: d` Sa'd�di, gCie�devi•h IIAe Florida mrm �'? N O d a A. Acceptance No 17 lLl2•> 'z '' rn f�%Z '''�.•'d G d d;c n d'o..a Hlgiinstian IY.3c o c '�SO G a Q . '. EX'.a T. GRADE Mimd Dxde O :�,`A�•,• �� CAULKL BY OR P a W� WOOD BUCKHY 0. ?ptABp60 ,••791646%`ya A #14 S.M.S,W I a MIN. EMBEDMENT INTO WOOD. 24 (SEE ELEVATION AT SHEET#1 26 FOR MAX FASTENER SPACING) /4'MA)I. INTERIOR 6 6 INTERIOR FINISH 'SILICONE D-TIONS', NOT BY LAWSON �O DOW CORNING 899 D3 rm • SC E-KEIREHEAD 5731 • ------------------- '0' rn TREMCO SPECTRUM 2 �II Q CO RACK BEDDING 25 21 E .GRADE z GLAZING DEPTH TO BE APPLIED BEHIND0 iii WINDOW FRAMEFLANGE By 60, 1 5 0 0 LAMINATED GLASS COMPOSITION TYPE 2 2x INSTALLER(TYP.) hit 5 '14 13� ITBM GLASS DESCIUPIION DESCRIPTION 2 0,090'-P—LAS—TI EAstnan y" WEATHERPROOF LOCK (LATCH AND SWEEP) OPTION 1w,x MWSTURE IE I a- 3 1/S'ANNEALED M BY OTHERS(TYP.: 1. BOTH EXTRUDED ALUMINUM AND PLASTIC LIFT HANDLE 0 IN LAMINATED GLASS COMPOSITION TYPE 1-�B'E�D LOCKS ARE QUALIFIED FOR USE ON ALL WINDOWS. X-,7�, 2. BOTH DIE CAST AND NYLON CAM LOCKS ARE QUALIFIED !.—DESCRIPTION If LUCHATE DESCRIPTION FOR USE ON ALL WINDOWS. EXTERIOR IV PLASTIC INTERLAYER 1 3. TWO (2) LOCKS ARE REQUIRED PER EACH VENT. ...................... • uroroY ANNEALED GLASS AS by 3 11/0'ANNEALED GLASS 41sENT"' EX.GRADE PERIMETER z CAULKING N13T BYFZ 'LAW,14 CT IM111TRIIS, :4- TO BE APPLIED BY OTHERS LAMINATED GLASS COMPOSITION TYPE 4 C I JAMBaIISM GLASS BEECEUP-N OBTAW IALUNATE DESCRIPTIGN ANNEALED GLASS STUCCO OVER METAL LATH NAILED T13 ER OR GRADE PLYWOOD SHEATHING m --T K KI'PLASTIC INTERLAYER by BE SPECIFIED BY ARCHITECT O.C.3 11/8'ANNEALED GLASS -0-1=F- JJ —y A—im Inc I(] OR(EXTERIOR FINISH BY OTHERS) H NOT BY LAWSON INDUSTRIES,INC. WOOD FRAME INSTALLATION DETAIL LAMINATED GLASS COMPOSITION - TYPE 5 r- DETAIL F.- ALUMINUM MULLION :2Z M :iFT118—HEAT-TE—ENGNT-ENNED CLASS ....... -.-xjF=—p, �A by. SEE MULUON APPROVALS FOR #12 X 3/4' S.D.S. SEE MULUON APPROVALS FOR MULLION TYPE,SIZE A14D MAX. MULLION TYPE,SIZE AND MAX. PLASTIC INTERLAYER FLAT HEAD,PHILLIPS. Z DESIGN PRESSURE LIMITATIONS. (SEE ELEVATION AND DESIGN PRESSURE UMMATIONS. 3 11/1W9"HFAT-STRENGHTENED GLASSI I" (ALUM.0.078"MIN.THICK) LIP TABLES FOR QUANTITY INTERIOR NOTE.THE LOWER PRESSURES OF SINGLE AND FASTENER SPACING) MAX. HUNG WINDOW OR MULL SHALL GOVERN 20 MOTE:THE LOWER PRESSURES OF SINGLE 11 'LING WINDOW OR MULL SHALL GOVERN SHIM # 12 S.D.S.X 1 1/4-L INTERIORSF E ELEV.FOR SPACING -@ F, SILICONE OPTIONS', DOW CORNING 899 SC NEE-MaREHEAD 5731 24 TREMCO SPECTRUM 2 GLAZING DEPTH NOTE: E E INSULATED LAMINATED GLASS COMPOSITION TYPE 6 ------------ 1.ALL STEEL IN CONTACT WITH 8 ALUM. TO BE PAINTED OR PLATED. .9 .2 ITEM GLASS DES DETUL LAIGNATS DES ON 2.METAL STRUCTURES: & A)STEEL:Fy-36 KSI MIN. 1 1/8'HEAT-STICERNEINTOONlED CLASS (STEEL E -a �E 1.) jk '9 z 2 0.090-PLASTIC INTERLAYER 18 GA.MIN.THICK-0.04 8' 1/4' TROSTOL PVB by 3 2/8-MEAT-STRENGHTENED GLASS K—y America,Inc EXTERIOR PERIMETER-j WINDOW FRAME B)ALUMINUM 6063-T5 MIN. :9.4 i 's 4 2/4'INSULATED AIR SPACE (ALUM,0.078-MIN.THICK) E2 SEALANT EXTERIOR 5 1/8'ANNEALED GLASS EXTERIOR GRADE PERIMETER CAULKING INSULATED LAMINATED GLASS COMPOSITION TYPE 7 FRAME MULLING DETAIL METAL STRUCTURE ATTACHMENT DETAIL OIEM GLASS DESCRIPTION DETAIL 1—.93 ON 1 1/8'ANNEALED GLASS a 0.090-PLASTIC INTERLAYER 6) SAFLEX FVB by 3 1/0'ANNEALED GLASS E.�—Ch-�.t AZW PRODUCT REVISED' A� 4 1/4'INSULATED AIR SPACE us"ith L'H�Floridan 5 I/Sa ANNEALED CLASS 1p dding Coda GLAZING DETAILS AND OPTIONS NOTE: WINDOWS WITH GLASS TYPES "6 & 7" INSTALLED ABOVE 30ft v IN THE HVHZ, THE I.G. IN THE EXTERIOR U=- SHALL BE TEMPERED TO CO LYZIH THE SMALL MISSILE IMPACT RESISTANCE dill?• It REQUIREMENTS (F BC-2017, Chapter 24 Section 2411.3.3.7). in DESIGN LOAD CAPACITY(PSF)-VIEW WINDOWS W/3H VENTS DESIGN LOAD CAPACITY(PSF)-EQUAL LITE W/NDOWS # +/-Pressures(psn # +/-Pressures(psq y WINDOW Jamb Glass Type Glass Type Glass Type WINDOW Jamb GlassT a GlassT a GlassT WIDTH HEIGHT Anchors 4 5 6 `�\\ YP YP Ype GiassType Glass Type Glass Type oo A \\ WIDTH HEIGHT Anchors 2 3 4 5 6 7 o q 19.125 50.625 60.0 80.0 80.0 19.125 26 80.0 80.0 60.0 80.0 80.0 80.0 r= a 26.5 50.625 60.0 80.0 80.0 26.5 26 80.0 80.0 60.0 80.0 80.0 80.0 r1 rn E• 37 50.625 60.0 80.0 80.0 �: 1D Ib U 1O 6 37 26 80.0 80.0 60.0 80.0 80.0 80.0 A a v rn r~ 42 50.625 60.0 BD.O 80.0 4 o D d z o \ 42 26 80.0 80.0 60.0 80.0 BD.O 80.0 48 50.625 60.0 80.0 80.0 rn p ut \ \ 48 28 80.0 80.0 80.0 80.0 BD.O 80.0 53.125 50.625 60.0 80.0 80.0 i \ 19.125 59 60.0 80.0 80.0 53.125 26 80.0 80.0 60.0 80.0 80.0 80.0 z w 26.5 59 60.0 80.0 80.0 19.125 38,375 80.0 80.0 60.0 80.0 80.0 80.0 �z o zo 54 37 59 60.0 80.0 80.0 26.5 38.375 80.0 80.0 60.0 80.0 80.0 80.0 N w= ,�„ I 42 59 6 60.0 80.0 80.0 37 38.375 IT. 80.0 80.0 60.0 80.0 80.0 80.0 00 a 48 59 60.0 80.0 80.0 /� 42 38.375 80.0 80.0 60.0 80.0 80.0 80.0 w of 53.125 59 60.0 80.0 80.0 i%� 48 38.375 80.0 80.0 60.0 80.0 80.0 80.0 ti Z p o 19.125 63 60.0 80.0 80.0 53.125 38.375 80.0 80.0 60.0 80.0 80.0 80.0 1 r 26.5 63 60.0 80.0 80.0 19.125 50.625 80.0 80.0 60.0 80.0 80.0 80.0 37 63 6 60.0 80.0 80.0 26.5 50.625 80.0 80.0 60.6 80.0 80.0 80.0 z 42 63 60.0 80.0 80.0 / j 37 50.625 80.0 B0.0 60.0 80.0 80.0 60.0 48 63 60.0 80.0 80.0 6 42 50.625 80.0 60.0 60.0 80.0 80.0 80.0 N CC 2 53.125 63 60.0 80.0 80.0 48 50.625 80.0 80.0 60.0 80.0 80.0 80.0 ® er 19.125 74.25 60.0 80.0 80.0 o-w•1 53.125 50.625 1 80.0 80.0 60.0 80.0 80.0 80.0 o 26.5 74.25 60.0 80.0 80.0 U) g 19.125 59 80.0 80.0 60.0 80.0 80.0 80.0 � z in 37 74.25 60.0 80.0 80.0 26.5 59 80.0 80.0 60.0 80.0 80.0 80.0 42 74.25 6D.0 80.0 80.0 p° 37 1 59 1 80.0 80.0 60.0 80.0 80.0 80.0 Q• o z 19.125 78 60.0 80.0 80.0 6 F r- ii 42 59 80.0 e0.0 60.0 80.0 80.0 80.0 E+ r• M 26.5 78 60.0 80.0 80,0 !/ 'C m 8 48 59 80.0 80.0 - - - 80.0 w w x 37 78 59.0 80.0 80.0 a I q 53.125 59 80.0 80.0 - - - 80.0 ] .Z ✓� 42 78 59.0 79.0 79.0 e w 19.125 63 80.0 80.0 60.0 80.0 80.0 80.0 DESIGN LOAD CAPACITY(PSF)-VIEW WINDOWS W/4H VENTS 26.5 1 63 P0O.0 .0 80.0 60.0 80.0 80.0 80.0 Z w # +/-Pressures(pst) j / 37 63 60.0 80.0 60.0 80.0 80.0 80.0 ~ WINDOW Jamb Glass Type Glass Type Glass Type 42 63 0.0 80.0 60.0 80.0 80.0 80.0 WIDTH HEIGHT Anchors 4 5 6 48 1 63 0.0 80.0 - - - 80.0 s n tl\ 19.125 59 60.0 80.0 80.0 53.125 1 63 e0.0 80.0 o \ 19.125 74.25 80.0 80.0 60.0 80.0 80.0 80.0 „ 26.5 59 60.0 80.0 80.0 26.5 74.25 80.0 80.0 60.0 80.0 80.0 80.0 r r 22 4'a 37 59 60.0 80.0 80.0 /i 6 //.; 37 74.25 8 60.0 80.0 - - - 80.0 42 59 60.0 80.0 80.0 42 74.25 80.0 80.0 80.0 48 59 60.0 80.0 80.0 48 74.25 80.0 80.0 80.0 g;d g o N 53.125 59 60.0 80.0 80.0 53.125 7a.25 7a.0 77.0 80.0 19.125 63 60.0 80.0 80.0 / j 19.125 78 80.0 80.0 60.0 80.0 80.0 80A E /./ s a z 26.5 63 60.0 80.0 80.0 j i 2s.5 le eD.o go.o so.o go.D eo.o 80.0 �•� ��a 37 78 8 80.0 80.0 - - 80.014i, 37 63 60.0 80.0 80.0 6 42 78 79.0 79.079.042 63 60.0 80.0 80.0 48 78 71.048 63 60.0 80.0 80.0 APPROVED 5t77741/ 53.125 63 60.0 80.0 80.0 CONFIGURATIONS 6�b1Dp gt f{�y osro 19.125 74.25 60.0 80.0 80.0 �liL-EQUAL LITE a ' y� 26.5 74,25 60.0 80.0 80.0 F N�, Z 37 74.25 8 60.0 80.0 80.0 /i /i• // �\ :4VDUCTREV:SED oza ce Ce�Pt 6US will]the FlcridaLij 42 74.25 60.0 80.0 80.0 AaptanmNo11121z•t1 �z . 53.125 74.25 60.0 80.0 80.0 6 o n' �pdrnlion Do: °°csge� 19.125 78 60.0 80.0 80.0pY 9���°ae v. . - °••° I 26.5 78 60.0 80.0 80.0 Mimi Dadc i mdua Couttoi m 37 78 8 60.0 80.0 80.0 42 78 59.0 79.0 79.0 APPROVED CONFIGURATIONS - EQUAL LITE a i FRAME HEAD FIXED MEETING RAIL BILL OF MATERIALS L-7701 L-7704 �° O -`---- --- - - - .. I ITEM PART # REQD. DESCRIPTION REMARKS to O v� O O4 1094 I FRAME TOP CORNEA o o F 1 L-7801 1 FIN FRAME HEAD 6063-T6 ALUMINUM z�-+ ,°62 e 2 L-7802 1 FIN FRAME SILL 6063-T6 ALUMINUM 1O 000 .50o A62 3 L-7803 2 FIN FRAME JAMB 6063-TG ALUMINUM ro m E- n-T {apqq n zzes 4 L-7704 1 FRAME FIXED MEETING RAIL 6063-T6 ALUMINUM v a.844 W o I4 I'078' 5 L-7705 1 VENT MEETING (TOP) RAIL 6063-TG ALUMINUM o c Z y iO I 6 L-7706 1 VENT BOTTOM (LATCH) RAIL 6063-T6 ALUMINUM 1.so4 W 7 L-7707 2 VENT JAMB (SIDE) RAIL 6063-T6 ALUMINUM Z��` z y 2.651I 8 L-7708 AS REQ'D. GLAZING BEAD ( 3/8' ) 6063-T5 ALUMINUM w x q R•' o 07 (0083-T6 ALU1diNOM) 8069-r8 AWIONUM) FRAME HE n _ 'M a. I=• U p 9 FS-006 AS REQ'D. FRAME ASSEMBLY SCREWS #8 X 3/4' P.H. PHILLIPS it W 41 0 10 FS-040 AS READ. INSTALLATION SCREWS #14 X 1 1/4' F.H./PHIL, � CS FRAME SILL FRAME JAMB p Z o L-7702 L-7703(does-T5,MMMMU 11 L-7531 AS REQ'D, BULB VINYL WTS'P 1/4' DIA. BULB #3033 d ti O (eo69_r6 LLU1m m) O �t.zs°—{ FRAME JAMB 12 PWS-003 AS REQ'D, FIN SEAL WEATHERSTRIP .187'x,230' 13 PWS-005 AS REQ'D. FIN SEAL WEATHERSTRIP .187'x.350' C C7 0 22E 1.441 14 PWS-009 AS REQ'D, FIN SEAL WEATHERSTRIP .187'x.310' z (�"„ Z ] i 2.437 15 HC-024-1 2 SELF ADHESIVE PILE PAD 1/4' X 1.1/2' ®H e x 16 L-7711 AS REQ'D. GLAZING BEAD/ INSULATED 6063-T5 ALUMINUM m w 2.64 17 L-4204 AS REQ'D. GLAZING BEAD - RA➢IUS 6063-T5 ALUMINUM w o z 3 18 L-7723 1 SASH BALANCE CAM/GUIDE (2 X VENT) S00 ~ c��' � �iaj 19 L-7725 2 RIGID VINYL SASH STOP (2 X FRAME) 461J �I�.oso •So° -.062 20 L-7727 2 BLOCK 6 TACKLE BALANCE BSI Balance Systems o a 21 L-7539 2 VENT LIFT LATCH 6063-T5 ALUMINUM z713 I 22 L-7523 IX LATCH VENT LATCH SPRING STAINLESS STEEL Q D W �.781 5 23 x AS REQ'D. GLAZING SILICONE SEE GLAZING @ SHT. 3 �'z W VENT INTERLOCK RAIL VENT BOTTOM RAIL g i 24 x 2 Laminated Glass SEE GLAZING DETAILS ~ L-7705 L-7706 VENT JAMB RAIL -`�' 2 O (603-TO iLUMUMM O (6oa9-rfi ncvualw) L-7707 O 25 HC-057-1 2 VENT LIFT LATCH MOLDED NYLON m O (eo03-Ta NMUMM) FRAME BOTTOM CORNER 26 HC-059-1 2 VENT SWEEP LATCH MOLDED NYLON 27 x 2 FRAME SILL FOAM GASKET SELF ADHESIVE —1�375—�-I � d� a 28 HC-026-1 1 SCREEN FRAME 6 MESH .o� O 29 L-7730 1 PRODUCT LABEL .C62 a •�_ VENT TOP CORNER 30 x x x x ` s�� E 2.000 zo6z A6z 1J65 31 SM-5504 AS REQ'D.JOINT SEALANT SM-5504 8 so 8 O $M062 N 32 x AS REQ'D.PERIMETER ACRYLIC CAULK OSI PDLYSEAMSEAL a a m e $ z z VENT JAMB RAIL --1.075— 1.235— z d m<i 6 g VENT TOP RAIL 4 ' VENT SPRING LATCH GLAZING BEAD GLAZING BEAD GLAZING BEAD L-7708 L-7711 L-4204 F„ use L-7539 ,s,<•- ..a8�, r O ® 16 I]- Ilyp\ ti eryryk' ..��LyP s —.062 (6063 M ALUUiNUM> (6063-Ts ALUMM U (6083-76 ALWMUII I ` \ ppY,y�' .��' • 05 o NRAG 0:4 tf1 n •.� 6: � PRODUCT REVISED �o'vN�•°�7 N O �'.`�� 450 as complying with the F ed& �'°���/'" � W � i e.,... a7 1L.O. mg Code K 0.. .8109 Acceptfincc No L I L.Z ~Z ^, :J IA13 .391 1 L O VENT BOTTOM FW Bxpirmion Cl@ IT I f -7 Ms VENT BOTTOM CORNER O 6—.773—I —,773— J � Mai Dadc Pro Caaaol x 'sti •• o (606_ u9a ) 466 FRAME & SASH CORNER DETAILS a sc9 d F3