Loading...
HomeMy WebLinkAbout7706 San Carlos Dr RevisionOFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 7706 San Carlos Dr., Fort Pierce, FL 34951 DETAILED DESCRIPTION OF PROJECT REVISIONS: Customer has decided they want a solar attic fan on their roof. Curia Mount Series. FL13339-R8. Attic Breeze. 13339.7 Permit #SLC2101-0549 CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CCC1326977 BUSINESS NAME: Modtek Roofing Inc. QUALIFIERS NAME: Luke McConnell ADDRESS: 1360 Old Dixie Hwy SW Ste 103 CITY: Vero Beach STATE: FL PHONE (DAYTIME): 772-213-8437 OWNER/BUILDER INFORMATION: NAME: _ ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC. 9123109 Revised 06130117 STATE: ST. LUCIE CO CERT. #: ZIP: 32962 FAX: NA s_A ZIP: ZIP: 1100% db� �' Product Approval USER: Public User Florida Building Code Online Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval Menu > Product or Application Search > Application List > Application Detall FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL13339-R8 Affirmation 2020 Approved Attic Breeze 1370 FM 116 Gatesville, TX 76528 (254)865-9999 travis. hipp@atticbreeze. net Travis Hipp travis.hipp@atticbreeze.net Travis Hipp 1370 FM 116 Gatesville, TX 76528 (877)288-4234 travis. hipp@atticbreeze, net Roofing Roofing Accessories that are an Integral Part of the Roofing System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received James L. Buckner, RE. @ CBUCK Engineering PE-31242 Keystone Certifications, Inc. 12/01/2029 Michael John Riemer, P.E. Validation Checklist - Hardcopy Received FL13339 R8 COI COI CertOf Indep James Buckner,RE. sc.PDF 1708.2 I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. https://www.floridabuilding.org/pr/pr app_.dtl.aspx?param=wGEVXQwt0quFsbTbi%2b3jRWwJ%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA... 1/3 2/1/2021 Florida Building Code Online Documentation from approved Evaluation or Validation Entity Yes No N/A Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Of FL # 1114odel, Number or Name 13339.1 1 OS —Solar Attic Fan FL13339 R8 COC Affirmation F1.13339 ss Rd Method 2 Option B 11/04/2020 11/04/2020 11/05/2020 Description Limits of use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. 13339.2 102_Solar Attic Fan Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. 13339.3 j 03_Solar Attic Fan Limits of Use - Approved for use In HVHZ: No Approved for use Outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation Instructions as a supplemental guide. 13339.4 1 04 Solar Attic Fan Limits of Use Approved for use in HVHZ: No Approved for use Outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. 13339.5 I OS —Solar Attic Fan Limits of Use Approved for use in HVHZ: No Models AB-201A, AB-202A, AB-253A, A13-252A, AB-2022A, AB- 3022A & AB-4022A. Self -flashing, solar powered fan units, with solar panel directly attached to fan unit shroud/dome Installation Instructions FL13339 R8 II 1-7 Attic Bre ze-SPAF Panel Direct to Flush Mount Unit EvalRgport.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339 R8 AE 1-7 Attic Breeze-SPAF Panel Direct to Flush Mount Unit EvaIR gort.pdf Created by Independent Third Party: Yes Models AB-201D, AB-202D, AB-251D, AB-2521), AB-401, AB- _ 402, AB-2022D, AB-3022D & AB-4022D. Self -flashing, solar powered fan units, with solar panel(s) remotely attached from fan unit, using low profile mounting brackets Installation Instructions y� FL13339 R8 II 2-7 Attic Breeze SPAF Panel Remote to Low Profile EvalReport.pdf Verified By: James L. Buckner, RE. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339 R8 AE 2-7 Attic Breeze-SPAF Panel Remote to Low Profile EvalReport.1df Created by Independent Third Party: Yes Models AB-201D, AB-202D, AB-251D, A13-252D, AB-401, AB- 402, AB-20221), AB-3022D & AB-4022D. Self -flashing, solar powered fan units, with solar panel(s) remotely attached from fan unit, using universal mounting bracket Installation Instructions FL13339 R8 II 3-7 Attic Breeze-SPAF Panel Remote Inclined EvalReport.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports EL13339 R8 AE 3-7 Attic Breeze: PAF Panel Remote Inclined EvalReport pd Created by Independent Third Party: Yes Models AB-601, AB-602 & AB-6022D. Self -flashing, solar powered fan units, with solar panel remotely attached from fan unit, using low profile mounting brackets Installation Instructions FL13339 R8 II 4-7 Attic Breeze-SPAF Panel Remote to Low Profile EvalRepor .pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339 R8 AE 4-7 Attic Breeze SPAF Panel Remote to Low Profile EvalReport.pd Created by Independent Third Party: Yes Models AB-601, AB-602 & AB-6022D. Self -flashing, solar powered fan units, with solar panel remotely attached from fan unit, using universal mounting brackets Installation Instructions FL13339 R8 II 5-7 Attic Breeze-SPAF Panel Remote https://www.floridabuilcling.org/pr/pr app dti-aspx?param=wGEVXQwtDquFsbTbi%2b3jRWw,l%2bwxNA5%2bc%2bapmo3X8QNQHZRRZRWQ%2ftA... 213 2/1/2021 Florida Building Code Online Approved for use outside HVHZ: Yes 1 Inclined EvalReport.pdf Impact Resistant: No ( Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Design Pressure: +115/-115 { Created by Independent Third Pa Other: Refer to evaluation report for limitations and conditions II Evaluation Reports m' Yes of use. Refer to manufacturer's installation instructions as a FL13332 R8 AE 5-7 Attic Breeze-SPAF Pane_ I Remote supplemental guide. Inclined EvalReport.pdf Created by Independent Third Party: Yes 13339.6 106_Cardinal Ventilation Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +115/-115 Other: Refer to evaluation report for limitations and conditions of use. Refer to manufacturer's installation instructions as a supplemental guide. Models CV-2000 & CV-3000. Self -Flashing, circular shaped solar powered fan units, with solar panel directly attached to fan unit hood/dome Installation Instructions FL13339 R8 II 6-7 AB -Cardinal SPAF Panel Direct to Flush Mount Unit EvalReport.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL13339 R8 AE 6-7 AB -Cardinal SPAF Panel Direct to Flush Mount Unit EvalReport.pdf Created by Independent Third Party 13339.7 Curb Mount Series I Curb Profile vent fan base for attachment to roof curbs Limits of Use Installation Instructions Approved for use in HVHZ: No FL13339 R8 II 7-7 Curb -SPA -CM -ER W 10 pdf Approved for use outside HVHZ: Yes Verified By: James L Buckner, P.E. @CBUCK, Inc P.E. # 31242 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +115/-115 Evaluation Reports Other: Refer to evaluation report for limitations and conditions ! FL13339 R8 AE 7-7 Curb -SPA -CM -ER W 10 pdf of use. Created by Independent Third Party: Yes Bat#c next Contact us -: 2.601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click here . Product Approval Accepts; ® �hccg Credit! Safe tit: CtI#'It�'�1{4:"I'IEIt'+i` https://www.floridabuilding.org/prlpr app_dti-aspx?param=wGEVXQwtDquFsbTbi%2b3jRWWJ%2bwxNA5d/o2bc°/`2bapmo3X8QNQHZRRZRWQ%2ftA... 3/3 UCK aEngineering SpPCialfiy Structural Englneprinq CBUCK, Inc. Certificate of Authorization #I8064 Evaluation Report Curb Mount Profile Base Solar Powered Roof Ventilation Appendix A To Evaluation Reports: FL13339 .1 To .5 Manufacturer Attic Breeze, LLC. 1370 FM 116 Gatesville, Texas 76528 (877) 288-4234 for Florida Product Approval # FL 13339.7 Rf Florida Building Code 6th Edition (2017) Per Rule 61G20-3 Method: 2 - B Category: Roofing Sub - Category: Product Name: Product Description: Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Report No. 18-101-C-SPA-CM-ER Date: 1/4/ 17 Contents: Evaluation Report Pages 1-6 Roofing Accessories that are an Integral Part of the Roofing System Curb Mount Curb Mount Series with Hood/Dome Mounted Solar Panel & Remote Mount Solar Panel Facsimile of digital copy signed by James L. Buckner, P.E. Electronically signed and sealed documents sl comply with the provisions of FAC Rule 61G15- \`\�\\\l a ►Jriii,� �5 L. SUC,y ��,,P�'' \,\GENSF'• yF,p� * ' No 31242 # .(\ STATE OF /'s`s��NA1.E�\\\ CBUCK, Inc. - Palm Beach County, Florida Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net 2018.01.04 15:00:37-05'00' 1-BUCK Engineering Spc�dalty Structural Engineering FL #: FL 13339.7 R6 Date: 1 / 4 / 18 Report No.: 18-101-C-SPA-CM-ER Page 2 of 6 CBUCK, Inc. Certificate of Authorization #8064 Manufacturer: Attic Breeze, LLC. Product Name: Curb Mount Vent and Fan Base Models Product Category: Roofing Product Sub -Category Roofing Accessories that are an Integral part of the Roofing System Compliance Method: State Product Approval Rule 61G20-3.005 (2) (b) Product Description: Curb profile vent fan base for attachment to roof curbs. Curb material is the same as the self flashing base in FL13339 Evaluation reports .1 to .5. Product Assembly as Evaluated: Curb profile base attached to roof curb designed by others. Appendix A Scope: Model Numbers Included in This Report: This Appendix A is linked to FL13339 Reports .1 through .5 The vent units model numbers in this report are the same product specification in Reports .1 to .5 , including the same minimum base specifications. This report .7 includes additional model numbers. The envelope structural components are the same as previous reports. The differences are internal mechanical and/or electrical. This report addresses options for attaching the Curb Profile to roof curbs. FL13339.7 AB-1020 AB-2042A AB-3042A AB-4042A AB-2042D AB-3042D AB-4042D AB-6042D 4 FL #: FL 13339.6 R6 Date: 1 / 4 / 18 Report No.: 18-101-C-SPA-CM-ER Page 3 of 6 ISPPcialfiy Structural Engineering GLICK, Inc. Certificate of Authorization #8064 Vent Unit Curb Base Support: Type & Minimum Strength Specification: Design of curbs is outside the scope of this evaluation 1 Wood Description: 15/32" or greater Plywood, or Wood (based on minimum density/specific gravityof0.42) 2 Steel 22 gauge minimum thickness, 33 ksi minimum yield strength (3) Aluminum 1/8 inch minimum thickness, alloy 6063-T52 or 6063-T6 Roof Slope: Slope shall be in compliance with FBC, Chapter 15 based on the p p type of roof covering. Allowable Wind Resistance: Performance: * Positive Design Pressure: + 115 PSF * Negative Design Pressure: - 115 PSF * Allowable design pressures for allowable stress design (ASD). Performance Standards: The following test protocol was performed to demonstrate compliance with the intent of the code as this product does not specifically addressed the performance standard in the code. ASTIVI E330-02 —Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors and by Uniform Static Air PressureDifference Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 6th Edition (2017), Section 1708.2. UCK .ffEncOneerinw, FL #: Fl- 13339.6 R6 Date: 1 / 4 / 18 Report No.: 18-101-C-SPA-CM-ER Page 4 of 6 ISPL-Oalfj Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Evaluation Report Scope: This product evaluation demonstrates compliance of this product with the structural wind load requirements of the Florida Building Code, as related to Florida Product Approval Rule 61G20-3.001. Limits of Use: . Scope of "Limitations and Conditions of Use" for this evaluation This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval'. Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(l)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. Design of support system is outside the scope of this report. Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof vent products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certification, Inc. (FBC Organization #: QUA 1824) SpQclalty Structural r-ngInL=L-rinCq Component(s) Material Standards: Evaluated Referenced Data: Vent Base Material Thickness: Yield Strength: Corrosion Resistance: Fastener for Wood Curb Type: Size: Standard: Corrosion Resistance: FL #: FL 13339.6 R6 Date: 1 / 4 / 18 Report No.: 18-101-C-SPA-CM-ER Page 5 of 6 CBUCK, Inc. Certificate of Authorization #8064 Steel 22 ga. 33 ksi Minimum Galvalume or Zincalume per ASTM A792 AZ 50 or in compliance with the FBC, Section 1507.4.3. Pancake or Hex Head Wood Screw #10 x 1 in. Minimum Per ANSI/ASME B18.6.1 Per FBC Section 1506.6 Fastener for Steel & Aluminum Curb Type: Size: Standard: Corrosion Resistance Self Tapping or Self Drilling Screw #12 x 1 in. Minimum Per FBC Section 1507.4.4 and/or SAE J78-1979 Per FBC Section 1506.6 1. ASTM E330-02 — Uniform Static Air Pressure Difference Test By Certified Testing Laboratories, Inc. (FBC Organization ID# TST 1577) Project #: CTLA 2002W, Dated: 11 / 20 /09 2. Quality Assurance By Keystone Certification, Inc. (FBC Organization ID# QUA 1824) Attic Breeze, LLC. Licensee #740 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 4. Engineering Analysis By CBUCK Engineering Report #17-144-EA, Dated: 6 / 11 / 17 CBUCK Engineering FL #: FL 13339.6 R6 Date: 1 / 4 / 18 Report No.: 18-101-C-SPA-CM-ER Page 6 of 6 SpL-CiaN'y Structural E=nginL L-rlf' q CBUCK, Inc. Certificate of Authorization #8064 Installation Methods Attic Breeze, LLC. Solar Powered Roof Vent Attachment To Curbs Attach to Wood Curb: Option to attach vertical leg or horizontal flange. Screw: pancake head or hex head minimum #10 x 1 inch 3 screw on each side for a minimum total of 12. Maximum spacing of 12 inches on center and within 6 inches of corners minimum distance to base edge 1 inch Attach to Steel (22 gauge min) or Aluminum (1/8 in min) Curb Option to attach vertical leg or horizontal flange. Screw: pancake head or hex head minimum #10 x 1 inch 3 screws on each side for a minimum total of 12. Maximum spacing of 12 inches on center and within 6 inches of corners minimum distance to base edge 1 inch Refer to manufacturer's installation instructions as a supplemental guide for attachment.