Loading...
HomeMy WebLinkAbout2021 - JACQUIN AND SONS - VET CLINIC-ModelREINFORCING STEEL SPECIFICATIONS WALL SIZE POST HOOPS MAT VERTICAL HORIZONTAL HEIGHT SIZE STEEL STEEL FOUNDATION DEPTH SCHEDULE BASED ON 30" DIA FOOTING, AND 3" ABOVE FTG. THEN 4-1/2" O.C. TO 2'-6" ABOVE FTG. THEN BAL. AT 18" O.C. JAMES BUSHOUSE P.E. PROFESSIONAL ENGINEER 20311 STATE OF FLORIDA 3300 NE 10TH TER. POMPANO BEACH FLORIDA, 33064 954-956-2203 PRECAST WALL SYSTEMS, INC. 1888 NW 22ND COURT POMPANO BEACH, FL 33069 954-973-8488 (MAY VERY DUE TO SITE SPECIFIC SITUATIONS) 20' CENTER TO CENTER COLUMN SPACING MAX. F.G. B B A A F.G. SOIL BEARING CAP. OF 2000 P.S.F. WALL HEIGHT ROCK SOLID DRY, UNDISTURBED MEDIUM DENSITY, SAND UNDISTURBED SATURATED, MEDIUM, DENSITY SAND ALTERNATE FOOTING DIMENSIONS PRECAST WALL SYSTEMS INC. 1888 NW 22 COURT POMPANO BEACH FLORIDA 33069 PH 954-973-8488 PROJECT; 12" x 13" POST CAP 16'-1 8" 1"5 8"14'-1 8" 4" 1'5 8" 1 2" WALL ELEVATION12" F.G.F.G. STANDARD CONDITIONS DETAIL 30" 8'-0"4'-9" 8'-0"4 - # 6 RE-BARS 7'-8"x19'-0"12"x13" REINF. 4'- 9" 3,000 PSI CONCRETE PLACED AROUND PRECAST COLUMN AFTER COLUMN PLACEMENT 8" 7 1 4" SECTION A-A PANEL TOP DETAIL N.T.S. 4 7 8" 8'- 0" SECTION B-B PANEL SECTION N.T.S 8'- 0" 7 1 4" 3 116" CENTER HORIZONTAL BARS OF PREFAB MAT IN THE PANEL, SEE REINFORCING SPEC. FOR MAT DETAILS. 8'- 0" 4" 3 116" NOTES: 1. PANELS = 7,000 PSI CONCRETE 2. COLUMNS AND CAPS = 4,000 PSI CONCRETE 3. FOUNDATIONS = 3,000 PSI CONCRETE 4. REINFORCING STEEL FOR PANELS TO BE ASTM A615 DEFORMED BARS MIN. 70,000 PSI, ALL OTHER STEEL TO BE 60,000 PSI 5. WIND LOAD DESIGN CONFORMS TO ASCE 7-10, FOR WIND LOAD OF 170 M.P.H. 3 SECOND GUST, EXPOSURE 'C', ASD DESIGN FOR A SOLID FENCE SECT. C-C LINE COL. 12"x13" SECT. C-C CORNER COL. 12"x13" SECT. C-C END COL. L 12"x13" AND HOOP FOR SIZE REFER TO POST: STEEL POST REINFORCEMENT 1-1/4"CLEAR COVER TO HOOP ON ALL POSTS NOTE:12"x13" SECT. C-C END COL. R 13" 13" 13" 12" 12" 12"312" 312" 2-1 4"2-1 4" 2-1 4" 312" 41 4" 13" 12"312" 2-1 4" 3 14" 41 4" 3 1 4" 4'- 0" 4'- 0" 12" x 13" COLUMN # 5 REBAR 12" O.C. IN BOTH DIRECTIONS CENTERED IN SLAB 3" COVER MIN. PLAN VIEW FRONT ELEV. VIEW SPREAD FOOTING DETAILS IF NEEDED. 3" COVER ALL SIDES MIN. C C PANEL - MESH REINFORCEMENT SYSTEM COLUMN - REINFORCEMENT DETAILS 18" 4'- 0" 8'- 0" 6" F.G.F.G. #5 REBAR 12" O.C. IN BOTH DIRECTIONS 2 MATTS REQ. 3" COVER MIN. 3,000 PSI CONCRETE PLACED AROUND PRECAST COLUMN AFTER COLUMN PLACEMENT 6" LONG x 4" WIDE x 6" TALL 3,000 PSI CONCRETE RISER PAD FOR PANEL SUPPORT, TYPICAL. 12" O.C.4" O.C. D-9 BARS D-9 BARS A.S. 0.09 A.S. 0.27