Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND QAXZON Builder Name: WYNNE BUILDING COPR. Street: \.Q Z- 0 0�, .e-0,\..- Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or.existing New (From Plans) 9. Wall Types.(1442.0 sqft.) Insulation Area. 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling, Types (1476.0 sqft.) Insulation Area. a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (W) 1446 b. Knee Wall (Vented) R=19.0. 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U=Factor: Sgl, U=0:54 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency . d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average.Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1445.5 sqft.) Insulation 'Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 46.69 Glass/Floor Area: 0.098 PASS Total Baseline Loads: 48.09 hereby -certify that the plans and specifications covered by Review of.the plans and:; this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance,,'' with the Florida Energy Code.. - � artrr , �. PREPAREDBY: Before construction is completed �,.• DATE: - 1-21D20 this building will be inspected for compliance with Section 553.908 -" I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Cod OWNER/ BUILDING OFFICIAL: \` DATE,DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies -as certified factory -sealed in accordance with R40112.1. ��EVIEWE R - Compliance requires an Air Barrier and Insulation Inspection Checklist.in accg eXtce�wPi �4�,02.4..1 an§lhis roject requires an envelope leakage test re pe L"ffla n an 7.00 ACH3O' 4b .4:1:�t�:R � PL1,(�N�E t-rLE�� ST.LUC1E COUNTY rlOCC 4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units:. 1 Worst Cate: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: .Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie. Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State; Zip: FT. PIERCE , ' Family Type: Single-family. FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree.Days Moisture Range. FL, Fort Pierce FL VERO_BEACH_MUNI 39 90. 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES NumberName. Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes 'Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ftZ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ftZ ____ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft- 0 192 ftz ____ 0 1 0 5 Slab -Oh -Grade Edge Insulatio BATH. 5 ft 0 45 ftz ____ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ftz ____ .0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft, 0 55 ftz 0 1 0 4/21/2020 10:24 AM EnergyGauge® USA 6.0.02. (Rev. 1) - FI6Res2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio 'LAUNDRY 6 ft 0 42 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING . 46 ft 0 488 ft2 ____ 0 1 0 ROOF / Roof, Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4. ATTIC V # Type Ventilation Vent Ratio (.1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown .45 ft2 0.1 Wood 6 Under. Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity . Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 _ 3 NW=>SE Exterior . Concrete Block.- Int InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block - Int InSINEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 - 7 .SE=>NW Exterior Concrete Block - Int InsEEDROOM 2 4.1 10. 0 8 0 80.0 ft2 .0 0 0.4 0 8 S=>N Exterior Concrete Block- Int InsBIEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Int In613EDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 _10 SE=>NW Exterior. Concrete Block- Int Insul ENTRY 4.1 6 0 8. 0 48.0 ft2 0 0 0.4 0 _ 11 SW=>NE Exterior Concrete Block- Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY . 4.1 6 0 8 0 48.0 ft2. 0 0 0.4 0 13 NE=>SW Exterior Concrete Block - Int InsiG6REAT/DINI 4.1 26 0 8 0 208.6 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int InsLOREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017. FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY 'CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In.. Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered: orientation. => changed to Worst Case. Wall # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 5 in None 0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 5 in None 0.54 0.25 N 37.5 ft2 1 ft 0 in 1 ft 5 in None 0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall: Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft2 24 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing SEER:15 34.8 kBtu/hr ch 0.8 1 syS#1 HOT WATER'SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FnRM R4ns-2n17 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC . Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply ---- ---- Return.--- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1. Attic 6 250 ft2 Attic 65 W Default Leakage. Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[[ ]] Jan [[ I] Feb Heatin[X] Jan [X] Feb [[ jj Mar [X] Mar Apr Apr May May Jun Jun Jul Jul Au Aug X] ] Sep. [ ] Oct Se [ ]Oct J�. Nov Nov Dec f X� Dec . Ventin [[ ]] Jan [[ ]] Feb [[XX]] Mar A r [ L Ma . [ Jun t Jul [ Au L [ ] Se [X] Oct Nov [ l Dec Thermostat Schedule: HERS 2006 Reference Hours, Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80. 80 80 .80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 .68 68: 68 PM 68 68 68. 68 '68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0:3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 LAUDRY- Default(8 Ibs/sq.ft. ft2 ft 0.3. BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 DINING/GREAT R Defaulf(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft, ft2 ft 0.3 BATH Default(8 lbs/sq:ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default 8 Ibs/s .ft. ft? ft 0.3 BEDROOM 3 ' . 4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (RevA) - F16Res2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT: PIERCE ; FL,, Permit Number: Y Owner: WYNNE BUILDING CROP Jurisdiction: 'ST. LUCIE COUNTY w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the.building. envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a. continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall.be aligned with The insulation in an dropped ceiling/soffit Y PP g /soffit the insulation and any gaps in the.air.ban ier.shall be sealed. shall be aligned with the air barrier. Access, openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill:plate shall be sealed. Cavities within corners,and headers of frame walls' The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity _sealed. with'a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors :The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations :Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned s ace shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting. Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and'wiring Batt insulation shall be cut neatly to. fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind �9ping and w2ring- Shower/tub The air barrier installed at exterior walls adjacent to: showers and Exterior walls adjacent to showers and tubs shall onexterior wall tubs shall separate them from the showers, and tubs. be -insulated. Electrical(phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended. by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceMbas. a. in aaaitlon, Inspection or log.waiis.snan De. in accoroance witn the provisions of lee-40U. 4/21/2020 10:25 AM EnergyGauge® USA 6.0.02{Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL' (EPL). DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family .2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. 15 this a worst case? (yes/no) 5. Yes b) Single package .SEER c) Ground/water source SEER/COP . 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area . a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 . 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump . HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 , b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame. (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry'(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g)' Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0' b) Cross ventilation No b) Single assembly 1lb. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building -Code, Energy Conservation, if not DEFAULT. I certify that this home has compiled with the Florida Building Code, Energy Conservation, through the above energy saving features, which will. be installed (or exceeded) In this home before final inspection. Otherwise, a new EPL display card will .be completed based on installed gode compliant features. . Builder Signature: Date: Address of New.Home\ \ �"'���C�� City/FL Zip: FT.. PIERCE, FL 4/21/202010:24:57 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 1