Loading...
HomeMy WebLinkAboutBlower door testDate: January 21, 2021 Contractor: Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave; Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method Permit #: 2008-0397 Job Address: 320 Nettles Blvd. Jensen Beach, FL 34957 Construction: ( ) New Construction — Complete ( ) Existing —After Addition House Infiltration T st Results CFM (50) _ Volume = 8420 ACH (50) _. CFM (50) x 60 / Volume = V Passing results must be & ACH (50) or less SLC Climate Zone 2 Test Date: February 1, 2021 Mec n►cal Ventilation required less than 3 ACH ( Pass ( )Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be.signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida.Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Ecolnnovative Address. 10570 S US Hwy 1, Ste 300 Port St. Lucie, FL 34952 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in,accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Kathleen S Connolly License/Certification #: 5060036 �rofe��iunal (Catification is awarded to Uatblern connollp All BPI ID# 5060036 who has successfully completed a comprehensive evaluation and is a certified Infiltration & duct _ 4� l _ as of July 6, 2020 Expires: 7/6/2023 o ='`•, ,�' ��®�;•oii°2 Larry Zarker Bruce DeMaine `. Chief Executive Officer Chief Operating Officer SM BUILDING PERFORMANCE INSTITUTE, INC. ==_.�