HomeMy WebLinkAboutProject Information VI Rack
Very Quiet, Low Velocity Cooler Air Defrost - 2,572 to 6,629 BTU/H Capacity
Application - Horizontal mounting, small to medium wine rooms
LRC's Rack Mount(RM)Low
Noise Evaporators are
designed for •S _
installation
inside a wine
rack or between
two ceiling
joists. RM
Evaporators
quietly supplies
refrigerated
and humidity
controlled air to
medium and
high temperature spaces,
making them an ideal choice for
small to medium size wine rooms. • provides consistent humidity
RM Evaporator units are available by maintaining a steady coil
in capacities from 2,572 to 6,629 temperature,reducing the need
BTU's per hour and can be used for expensive temperature units can t made to order
with R-22,R134a or R404a and humidity controls in most • Copper coils and or stainless
refrigerants.Chilled water models applications. Contact LRC for steel cabinets available for harsh
are available by special order. details. environments
RM units have multiple access • Insulated rust-proof aluminum Our Application Engineers can
doors that can be removed as housing.Flat black powder help you design the system you
needed for air intake and exhaust coated finish available.Call for need.Call us today,562-944.1969,
depending on how the unit is details. and we'll help you get the right
installed. RM's Motor Speed • Secondary drain pan standard LRC product for your project.
Control(standard)allows for • Thermally protected motors
airflow adjustment through the • Each coil pressure tested to tUR UNCONDITIONAL
it
unit while maintaining room over 380 psig for maximum
system integrity we're proud of the workmanship that goes into
humidity within desired range.
• Facto wired for easy field every LRC product.Because of our exacting design
� y and manufacturing standards,and our thorough
Contact LRC's Application
installation testing prior to shipping,we unconditionally
E guarantee our products to be free from
Engineers for more information.
Expansion and liquid line manufacturing defects for one year.You can taunt
• Low noise design for minimum solenoid valve pre-installed on LRC Coil for quality heat transfer products.
acoustical impact • Coil and drain pan coated with
• Compact design allows unit to LRCCoatTM anticorrosion coating Visit www.Irecoil.com for
be inconspicuously integrated • ETL listed installation and maintenance
into a wine room decor Options Available— data, and wiring diagrams.
• High performance staggered Call for details
calls,with copper tubing • Humidity controls available At LRC,we are continuously working to
improve our products,therefore,we reserve
mechanically expanded into • pre-charged,custom or OEM the right to make changes without notice,
aluminum collared fins
"=Assumes areas surrounding the humidity controlled room are maintained to ASHRAE conditions ®LRC Coil Company 2015
of 80"/67°. For humidity controlled rooms with different surrounding conditions,please contact LRC.
Santa Fe Springs,CA 90670 (562)944-1969 Fax:(562)944-4979 www.Irccoil.com
VIC Rack
Mount- (Rm)—
1 '
All measurements are in inches. Electrical Connections
and Air Outlet
Access Doors(all 4
sides and end)
O
°Q ° 3-D View
O Q° O o
W/z
o q
°
o �
4'/z
O
°
0
Refrigeration a
Top View Connections p
and Air Inlet
Access Doors
(all 4 sides and end)
L 3h 11
° O
O - ° O 7 O O
H O O
O O O O
'._.
°
O
Front View Drain stub located inside unit Inlet End View
Rack Mount(RM)Electrical and Physical Data Rack Mount(RM)Performance Specifications
115V Impeller Height Length Connections Unit BTUH Cap.@ 17°TD
Model No. Amps Qty (H) (L) Liq. Suct. Wt. 38°SST,55°EAT
RM-25 0.77 1 113/8 293116 3/8 3/6 26 Model No. CF'M R22 R134a R404a
RM-35 0.77 1 1134, 36 3/,, 'h, 29 ISM-25 220 2,654 2,572 2,633
RM-50 0.77 1 143/8 36 3/a 5/a 35 RM-35 260 3,543 3,228 3,478
RM-65 1.85 1 143/a 36 3/6 s/a 39 RM-50 335 4,996 4,550 4,723
Expansion valve and liquid line solenoid valve standard RM-65 420 6,629 6,500 6,603 a
For air flow into and out of the unit, at least one access door
must be removed from each end. Please note-
Custom configurations available;call factory for details. -LRC cooling units are designed to minimize noise and vibration.
To reduce/eliminate amplification of existing noise or vibration,
Our website has a Wine Room Capacity Calculator that extreme care must be taken during installation.Please refer to
instantly determines room loads and capacities,enabling supplied installation instructions and use proper installation
you to know cooling equipment requirements based on materials to minimize acoustic impact.
your exact specifications.Visit LRCCoil.com for details. -The use of oversized condensing units can lead to poor wine
mom evaporator performance and possible system failure.When
installing a LRC wine room evaporator,it is recommended that
condensing units be sized LESS than or equal to the evaporator
Our Application Engineers can help you design capacity.Contact LRC Coil's Application Engineers at 562-944-1969
the system you need. Call us today, for questions or assistance.
562-944-1969, and we'Il help you get the right -LRC recommends evaporator maintenance access is designed into
LRC product for your project. every wine room installation.
Santa Fe Springs,CA 90670 (562)944-1969 Fax:(562)944-4979 www.Irccoil.com
Sept. 18,2014
Revision: REL
Celseono Air Cooled Condensing Unit
Model: AJA4480YAAD*
BoM: 2G746-** R-134a 314 HP
- - W MAY.
..0 anx. .,
O 1
o...... o own
_ II q A
y - O
i�
L YAX.
U7 _
12.5 O~ I T 1
[318�
. p .
a
--
VAX. -._......_��_�
[330]
Large Capacity Pump Down Unit
Model Dimensions, inches Line Connection* Pum down Air Oil Ch Gr. Wt.
L W H CH Suction Liquid 90°F 90% SCFM Oz. Lbs.
AJA4480YAADC 200 143 12.1 12.0 5/8"S 3/8" S 6.6 Ibs. 230 26 64
AJA4480YAADP 5/8" S 3/8"S 6.6 lbs. 64
*F=Flare,S=Solder,RF or RS=Rotolock with Flare or Solder Connections,C—Compression Fitting
Factory charge: 20 PSIG Nitrogen—MUST BE EVACUATED
Ambient Temperatures
Evaporator T, 80°F 90°F 100°F 110°F
OF PSIG BTUH Watts Cond T BTUH Watts Cond T 13TUH Watts Cond T BTUH Watts Cond T
20 18.4 5305 875 1I2 4791 878 120 4300 881 128 3829 884 135
25 22.1 5883 946 116 5328 954 123 4796 962 131 4287 970 139
30 26.1 6467 1022 120 5871 1035 127 5298 1047 135 4749 1060 142
35 30.4 7051 1101 124 6413 1119 1 131 5800 1136 138 --- --- ...
40 35.1 7631 1184 127 6950 1207 135 6294 1229 142 --- ___ ___
45 40.1 8201 1271 131 7550 1298 139 ___ ___
50 45.5 8756 1362 135 7988 1394 142 .._ ___ ___
60 Hz Performance
Return gas temp.65°F,5°F sub cooling
Sept. 18,2014
Revision:REL
Specifleations/Parts:
Unit Model AJA4480YAADC Unit Model AJA4480YAADP
Unit Hill of Material ZG746-59 Unit Bill of Material 2G746-89
Refrigeration Range 20"F to 550 F Receiver Tank 510-10002
Design Pressure Low 150 Liquid Valve 56662
Design Pressure High 235 Suction Valve 56661
Nominal Volts-Hz-Ph 115/60/1 Power Cord 85106-14
Voltage Ran Le 103 to 127 Filter Drier 71116
Min,Circuit Ampacity 17.1 Sight Glass 70084
Max.Fuse Size(amps) 30
Unit Model AJA4480YAADC
Compressor Model AJA4492YXA Unit Bill of Material 2G746-99
Comp.Bill of Material AJ150AT-434-P2 Receiver Tank 510-10002
Compressor RLA/LRA 13/69 Liquid Valve 56662
Overload 8300CRAH22 Suction Valve 56661
Relay 820ARR31388 Power Cord 85106-14
Run Capacitor N/A L.P. Control 84026-2
Run Capacitor Rating N/A
Start Capacitor 85PS165C77 Unit Model AJA4480YAADP
Start Capacitor Rating 378-440 MFD 165V Unit Bill of Material 2G746-109
Receiver Tank 510-10002
Fan Motor 810-10003 -Liquid Valve 56662
Fan Motor RLA .95 Suction Valve 56661
Fan Blade 515-10003 Power Cord 85106-14
Fan Shroud/Guard Combo 707-00005 Filter Drier 71116
Condenser 506-10008 Sight Glass 70084
L.P. Control 84026-2
Receiver Tank 510-10002
Liquid Valve 56662
Suction Valve 56661
Power Cord 85106-14
Unit Drawin DGU1971-09
Wiring Dia ram 91266-02
Replacement Kit:Relay K71-14
Replacement Kit:OIL K90-51
Replacement Kit: St,Cap K 146-18
Sept. 18,2014
Revision:REL
Electrical Diagram Page 3
—..._
C�ERLGAD CFB. I'Akl FSI.
9 �31ZfiH-GI
l
COW 55i112 PA.CK
TERMINALS
r" r~
S la... ) ELECTRICI ANC=1TJ 01IMM AND :NSTRLCTICh5
I. SPLICE INIZIC TINS nNxA LEADS. FROM OISCChK-CT SNITCH,
RELAY - rPDTr4T€0L TO STRIPPED LEQ5 M THIS LHICLGWRE,
RLk CAPACITCR 7- IMCMIN5 P09CR LFAOS WJST mr GIm'CR CrNrLCTCFS
BLACK€23OW— IAM tEw..0WA MS C-;GJC'I-Imi IN CIN41- 51f1J'6ww.I
IfN$1TEM5W 7 I w 75'C4YIN— 11111hr.
i, CChtECT IKXNI4C 54i3:R47 LEAD ?'TI W&EN 5CNGN.
..._,_ 4. VKN T.P.CZ, APe'40YF;7 4 TERNATE RELAY IS LSED,
r. , 1 5 4 .•' CCNI'kV LEADS TO SMI `✓` IDEREa TERMINAL$,
REGAIaCLESS OF i.CY'ATIN.
5. A JJLM5ER WIRE MY 6E C�EVER IIETMEEN 14 d 06
TEMNALS TO DIST51113JTE v RES rOR EASE Cr 'AIRING.
I
TI-E #4 3 06 TERW[NALS AlE M`:R"NG TERMINALS 91]TH NJ CES I 1 MfERWL C011M CTIsONS TO RELAy.
f START CAPACITOR
f I C T4& EDER RES I STAR
} I I FAN ICT;NI'T.W..RI P[Y111 MAK)
mr=SLFIE COMTF3<1L I'YVI
W) I L POYER LEADS FRCN 1GfbTICNALI
196Oh1 CT SIP I T-0' i.. -
L_ 6#I I T CL1IlECT I Ok — J r—
IOENTIFICATI,OV-18 (*Elj'-AAL: