Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
EnergyGauge Summit® v6.10 INPUT DATA REPORT Proiect Information Project Name: D R HORTON Orientation: 0 Deg Clockwise. Walls & Windows will be rotated accordingly Project Title: EXPRESS HOMES Building Type: Office Address: 9213 POTOMAC DR Building Classification: Renovation to existing building Enter Address here State: F], No.of Stories: ] Zip: 34981 GrossArea: 430 SF owner: Enter Owner's name here Zones No Acronym Description Type Area Multiplier Isfl Total Area Intl I Prozol Zone 1 CONDITIONED 430.3 1 430.3 ❑ Spaces No Acronym Description Type Depth Ifil Width Height Multi Total Area Ift] Ift] plier lsfl Total Volume ]cf] 3/30/2020 EnergyGauge Summit® v6.10 1 In Zone: PrOZol 1 Pr0Zo1Sp1 ZoOSpI Office- Open Plan 20.66 20.83 9.00 1 430.3 3873.1 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 1 LED General Lighting 18 10 180 Manual On/Off 2 ❑ Walls (Walls will be rotated clockwise by building rotation value) No Description Type Width H (Effec) Multi Area Orientation Conductance Heat Dens. R-Value Ift] Ift] plier Ist] [Btu/hr. sf. F] Capacity Ilb/ct] ih.sLF/Btu] IBtu/sLFI In Zone: PrOZol 1 PrOZolWal 5/8"stucco 21.00 9.00 1 189.0 North West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 2 PrOZoIWa2 5/8"stucco 20.66 9.00 1 185.9 South West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO 13TWN24"oc/.5" GYP 3 PrOZolWa3 5/8" stucco 4.00 9.00 1 36.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO 13TWN24"oe/.5" GYP Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area jBtu/hr sf F] IN I ft] plier Isf] 3/30/2020 EnergyGauge Summit® v6.10 In Zone: PrOZol In Wall: PrOZo1Wal 1 PrOZolWalWil North West No 0.9000 0.50 0.40 16.00 6.66 1 106.6 ❑ Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf] [Btu/hr. sE F] [lb/ct] [Btu/sf. F] [h.sf.F/Btul In Zone: In Wall: Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value Ift] Ift] plier [sf] [deg] [Btu/hr. SE F] [Btu/sE F] Ilb/cf] [h.sEF/Btu] In Zone: PrOZol 1 PrOZoIRfl T24R19b 21.50 20.00 1 430.0 0.00 0.0339 0.86 5.47 29.5 ❑ Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btufhr sf FI Ift] Ift] ISf] [Sf] In Zone: In Roof- ❑ Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value Ift] Ift] plier Isf] [Btu/hr. sE F] jBtuAE F] jlb/ci] jh.sEF/Btu] In Zone: PrOZoI 3/30/2020 EnergyGauge Summit® v6.10 I PrOZOIFII Concrete floor, 21.50 20.00 1 430.0 0.5987 9.33 140.00 1.67 ❑ carpet and rubber pad Systems PrOSyl System 1 Constant Volume Air Cooled Split System <65000 Btu/hr No. Of Units 1 Component Category Capacity Efficiency IPLV Cooling System 2 Heating System 3 Air Handling System -Supply 24000.00 17.00 8.00 24000.00 11.00 800.00 0.40 ❑ ❑ ❑ Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacity Cap.Unit UP Rt. Efficiency Loss Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire Isf/ft/N0l IWI El 3/30/2020 EnergyGauge Summit® v6.10 4 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sEFI [in[ [in[ 01 01 Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sEFI ASHULDbITntM User Defined 2 0.9000 0.5000 0.4000 ❑ tl-Oth frm Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used Ih.sf.F/Btu[ IN [Btu/h.ft.F[ [Ib/ct] [Btu/Ib.F[ 187 Mad 187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 Lj BOARD,1/2IN 151 Mat115l CONC HW, DRD, I40LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 244 Mat1244 PLYWOOD, 1/21N No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 ❑ SIDING 3/30/2020 EnergyGauge Summit® v6.10 5 91 Matl91 BUILDING PAPER, Yes 0.0600 ❑ PERMEABLE FELT 407 Mat1407 R-19 Generic Insulation No 19.0000 0.4147 0.0218 0.30 0.2000 ❑ 414 Mat1414 R-8 generic Insulation No 8.0000 0.1746 0.0218 0.30 0.2000 ❑ 80 Mat180 AIR LAYER, 4IN OR Yes 0.9200 ❑ MORE, HORIZ. ROOFS Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] ]Btu/sEF] ]Ib/cf] ]h.sEF/Btul 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.7 ❑ Layer Material Material Thickness Framing No. jft] Factor 1 151 CONC HW, DRD, 140LB, 4IN 0.3333 0.000 ❑ 2 178 CARPET W/RUBBER PAD 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct ]Btu/h.sEFI ]Btu/sf.F] ]Ib/cf] jh.sEF/Btuj 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. ]ft] Factor 1 268 0.625" stucco 0.0521 0.000 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0,0625 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 3/30/2020 EnergyGauge Summit® v6.10 No Name Simple Massless Construct Construct Conductance jBtu/h.sEFj Heat Capacity [Btu/st'.Fl Density RValue fib/cq [h.sEF/Btul 1053 T24R19b No No 0.03 0.86 5.47 29.5 ❑ Layer Material Material Thickness Framing No. IN Factor 1 82 ASPHALT -SHINGLE AND SIDING 0.000 ❑ 2 91 BUILDING PAPER, PERMEABLE FELT 0.000 ❑ 3 244 PLYWOOD, 1/2IN 0.0417 0.000 ❑ 4 414 R-8 generic lnsulatrion 0.1746 0.000 ❑ 5 407 R-19 Generic Insulation 0.4147 0.000 ❑ 6 80 AIR LAYER, 41N OR MORE, HORIZ. 0.000 ❑ ROOFS 7 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.000 ❑ 3/30/2020 EnergyGauge Summit® v6.10 7 - - wrightsoft Building Analysis Entire House D R HORTON Jo b: Date: Mar 30, 2020 By: ENERGYCALCS.NET ENERGYCALCS.NET 267 DELEON RD, DEBARY, FL 32713 Phone: 386-775-0908 Fax: 888-262.5406 Email: MAGGIEQENERGYCALCS.NET Web: w .energycalra.net Lic... For: D R HORTON MODEL 1828 CALI 9213 POTOMAC DR, PSL, FL 34981 .- • •roftiobs Location: Indoor: Heating Cooling St Lucie Co Infl, FL, US Indoor temperature (°F) 70 76 Elevation: 26 It Design TD (°F) 29 14 Latitude: 28°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(grAb) 24.4 54.7 Dry bulb (°F) 41 90 Infiltration: Dailyrange (F) - 15 ( L ) Method Simplified Wetbulb(° - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces • 0 Component Btuh/ft2 Btu %of load Walls 4.1 1252 7.6 Glazing 10.7 1202 7.3 Doors 0 0 0 Ceilings 0.9 390 2A Floors , 3.1 1319 8.1 Infiltration 14.4 5941 36.3 Ducts 2451 15.0 Piping 0 0 Humidification 2688 16.4 ventilation 1138 6.9 Adjustments 0 Total 16381 100.0 •• • Aun 1755 i_DT Component Btuh/t2 Btu %of load Walls 2.8 844 6.0 Glazing 45.3 5077 36.0 Doors 0 0 0 Ceilings 1.3 556 3.9 Floors 0 0 0 Infiltration 2.8 1176 8.4 Ducts 3325 23.6 Mentilation 547 3.9 Intema I gains 2561 18.2 Blower 0 0 Adjustments 0 Total 1 1 14086 100.0 Latent Cooling Load =5406 Btuh Overall U-value = 0.114 Btuh/ft2-°F WARNING: window to floor area ratio = 26.7%-more than 25%. lies W'1�11S5iQfL" 2020•Mar-3014:11:14 .-..... «• <>-.«. RlghtSuite® U niversal 201919.0.17 RSU19927 Page 1 ...ere\Margamt\Downloads\D R HORTON 1828 CALl.rup Calc = MN5 Front Door faces: NW Right -Suite® Universal 2019 Load Calculation Mrksheet Job: wrightsoft` Date: Mar 30, 2020 SALES OFF By: ENERGYCALCS.NET D R HORTON ENERGYCALCS.NET 267 DELEON RD, DEBARY, FL 32713 Phone: 386-775-0908 Fox: 888-262-5406 Email: MAGGIE@ENERGYCALCS.NET Web: www.energycalm.net Lic... Projectio®inatim For: D R HORTON MODEL 1828 CALI 9213 POTOMAC DR, PSL, FL 34981 Zone: SALES OFF LWH: 20.0 x 21.0 x 9.0 1. DESIGN CONDITIONS -COOLING ( Aug 1700 LDT ) Dryl3lb RH kbisture Range WetBlb Outdoor Condit ons —> 90 57 15 77 Indoor Conditions —> 76 50 63 TOD Correction —> 0 Difference 14 54.7 [ Milt = 1.0 ] — 2. GLAZINGSOIARHEAT GAIN ( Let = 27.50 % Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCkltlt SC Sens/A Sens GLAZ 01 nw 112 90 0.00 n 1.00 0.61 40.2 4499 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 nw 112 112 0.370 13.9 N - 5077 WALL-01 ne 45 45 0.143 GF 20.8 N m 134 WALL-02 sw 180 180 0.143 GF 21.7 N m 558 WALL-03 nw 189 77 0.143 GF 13.8 N m 152 FLOR-01 420 420 0 0 0 CEIL-01 420 420 0.032 45 41.3 w 556 4. INTERNAL HEAT GAIN PEOPLE Sens Latent kwty Total Sensible Latent Schedule ftZ/prsn # people Btuh/prsn Btuh/prsn Office 200 0 2 250 200 499 420 8to6-E 0 0 0 0 0 0 0 Wrightsoft, . 2020-Mar-3014:11:14 .,.„. Right-Sufte® U niversal 201919.0.17 RSU19927 Pagel ...ers\MargaretWownloads\D R HORTON 1828 CALI.rup Calc=MN5 Front Door faces: NW LIGHTS Lamp/blst+fi)dure W/ft' W Total Factor Space Sens Schedule W fract Fluor NIB + Rec trof 0.70 0 294 1.20 1.0 1109 8to6-E Ru or MB + Rec trof 0 0 0 1.20 1.0 0 Flu orMB+Rectrof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ftz W 8to6-E 0.70 0 1.00 3.412 0 953 0 #/ftz # 0 0 1.00 0 0 0 0 #/ftz # 0 0 1.00 0 0 0 0 #/ftz # 0 0 1.00 0 0 0 0 #fft2 # 0 0 1.00 0 0 0 0 #/ftz # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ftz # Total Per mtr Load Sens Schedule Btu factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 77 cfm x db Temp Diff 13.9 x 1.10 1176 > x bbist. Diff 54.7 x 0.68 2855 6. SUBTOTAL COOLING LOAD FORSPACE Sensible Latent 10213 5406 Envelope 10213 3275 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HFAT GAIN Gain factor 0.24 xLine 6 Sensible Gain 2452 8. COOLINGFAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 12666 (L 8 Sens ) / (Xfer xSupplyTD ) = cfm Est Cooling cfm = ( 12666) / ( 1.10 x 21.0 ) = 549 Actual Cooling Fan = 400 9. VENTILATION OA 36 cfm -> x db Temp Diff 13.9 x 1.10 547 -> x Nbist. Diff 54.7 x 0.68 1328 ► rightsoft5 2020-Mar-3014:11:14 Rig ht-Sutte®Universa1201919.0.17 RSU19927 Page 2 ...ers\Margaret\Downloads\D R HORTON 1825 CALI.rup Cato = MN5 Front Door faces: NW 10. RETURN AIRPLIIVUM Lights Total power(W) 294 0 Transmission load (plenum upper surface) 0 Space load credit(plenum lowersurface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0.09 xLine 6 Sensible Gain 873 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 14086 5406 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB -Outside DB) 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval GLAZ-01 nw 112 112 0.370 WALL-01 ne 45 45 0.143 WALL-02 sw 180 180 0.143 WALL-03 nw 189 77 0.143 FLOR-01 46 46 0.989 CEIL-01 420 420 0.032 70 - 41) = 29 [ Milt = 1.0 ] HTD Loss 29.0 1202 29.0 187 29.0 746 29.0 319 29.0 1319 29.0 390 15. INFILTRATION Loss 186 cfm x db Temp Diff 29.0 x 1.10 5941 16. SUBTOTAL HEATINGLOADFOR SPACE 10104 Envelope 10104 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLYDUCT HEAT LOSS Loss factor 0.21 x Line 16 Loss 2130 Less transfer 0 Redistribution 0 18. VENTILATION OA 36 cfm x db Temp Diff 29.0 x 1.10 1138 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) #of Glazing panes 2.0 (Max = 52.0 for 2pane ) 20. RETURN DUCT HEAT LASS 222 cfm x 0.03.20 g/100cfm/d = 7.1 gpd 2688 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 16381 Loss factor x Line 16 Loss WrightsofL" 2020-Mar-3014:11:14 ..,..-. ....... Right -Suite® Universal 201919.0.17 RSU19927 Page ...ems Margaret%Doxoloads\D R HORTON 1828 CALl.rup Calc = MN5 Front Door faces: NW J Right -Suite@ Universal 2019 Short Form Job: wrightsoft Date: Mar 30, 2020 Entire House By: ENERGYCALCS.NET D R HORTON ENERGYCALCS.NET 267 DELEON RD, DEBARY, FL 32713 Phone: 386-775-0908 Fax: 888-262-5406 Email: MAGGIE@ENERGYCALCS.NET Web: v .energycalcs.net Lic... For: D R HORTON MODEL 1828 CALI 9213 POTON46C DR, PSL, FL 34981 Htg Clg Htg Clg Outside db (°F) 41 90 Inside db (°F) 70 76 Outside RH (%) - 57 Inside RH N - 50 Outside wb (°F) 77 Inside wb (°F) - 63 Dailyrange (°F) 15 Design TD (°F) 29 14 Nbisture diff. (grAb) 55 Heating Equipment Cooling Equipment Make DAIKIN Nbke DAIKIN Nbdel RXB24 Nbdel RXB24 Type SplitASHP Type SplitASHP Efficiency 9 HSPF COP/EER/SEER 17.0 Heating Input Sensible Cooling 14.8 Wtuh Heating Output 21.2 Wtuh@47°F Latent Cooling 6.4 Wtuh Humidifier 7.1 gpd Total Cooling 21.2 Wtuh Leafing Air Tem p 118.2 °F Leafing Air Tern p 55.0 °F Actual Heating Fan 400 cfm Actual Cooling Fan 400 cfm Equipment Location Entire House System Type PEAKCV Fan Nbtor Heat Type PACKAGE Fan &MotorCombined Efficiency 0 % Static Pressure Across Fan 0 in H2O MANE I Area I Heat ft2 Loss Sensible Latent iHtg I Clg I Time Gain Gain cfm cfm SALES OFF 420 16381 1 14086 1 5406 1 4001 4001 Aug 1700 LDT Entire House 420 16381 14086 5406 i 4001 400 Aug 1700 LDT +� wrlghLoFt' 2020-Mar-3014:11:14 s -- ..®.„ Right -Su He® U niversal 2019 19.0.17 RSU19927 Page 1 ...era\Margaret\Dovm loads\D R HORTON 1828 CALl.rup Calc=MN5 Front Door faces: NW Right -Suite ® Universal 2019 Load SunynaDate: Mar 30, 2020 ry Job: '�' WI`IC,�i1tSOft' SALES OFF By: ENERGYCALCS.NET D R HORTON ENERGYCALCS.NET 267 DELEON RD, DEBARY, FL 32713 Phone: 386-775-0908 Fax: 888-262-5406 Email: MAGGIE@ENERGYCALCS.NET Web: v .energycaics.net Lic... For: D R HORTON MODEL 1828 CALI 9213 POTOMAC DR, PSL, FL 34981 Zone: SAGES OFF COOLING LOAD 1. DESIGN CONDITIONS at Aug 1700 LDT Peak load atAug 1700 LDT Inside: 76 °F Outside: 90 °F TD: 14 °F RH: , 57 % M7istDiff: 54.7 gr/lb Mu It: 1.0 Ins.wb Sensible 2. SOLAR RADIATION THROUGH GLASS 4499 3. TRANSMISSION GAINS Sensible 1977 Walls: 844 - Glass: 578 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 556 - 4. INTERNAL HEAT GAIN Sensible Latent 2561 Occupants: 499 420 - Lights: 1109 - Motors: 0 - Appliances: 953 0 - 5. INFILTRATION: Outside air cfm: 77 1176 6. SUBTOTAL: Space load Sensible Latent 10213 En\elope 10213 3275 - Less external 0 - Redistribution 0 0 - 7. SUPPLY DUCT 2452 8. SUBTOTAL: Space load+supplyduct 12666 Actual cfm: 400 at supplyTD: 21 - 9. VENTH.ATION: Make-upaircfm: 36 547 10. RETURN AIR LOAD: Lighting + plenum (net) 0 11. RETURN DUCT 873 12. TOTAL LOADS ON EQUIPMENT 14086 HEATING LOAD 13. DESIGN CONDITIONS Milt 1.0 Inside: 70 °F Outside: 41 °F TD: 29 °F 14. TRANSMISSION LOSSES 4163 Walls: 1252 - Glass: 1202 - Doors: 0 - Partitions: 0 - Floors: 1319 - Ceilings: 390 - 15. INFILTRATION: Outside air cfm: 186 5941 16. SUBTOTAL: Space load 10104 En%elope 10104 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLYDUCT: 2130 18. VENTILATION: Ma ke-u p ai r cfm: 36 1138 19. HUMIDIFICATION 2688 Piping 0 20. RETURN D UCI' 321 21. TOTAL HEATING LOAD ON EQUIPMENT 16381 ' "wrighYS4ft'° Right-SuBe® Universal 201919.0.17 RSU19927 ...erslMargaretWovmloads1D R HORTON 1828 CALI.rup Celc = MN5 Front Door faces: NW 63 °F Latent 420 2855 3275 1328 5406 202D-Mar-3014:11:14 Page 1 Sheet 1 Job #: D R HORTON Scale: 1 :63 Performed by ENERGYCALCS.NET for: Page 1 D RHORTON MODEL 1828CALI ENBr.Y CA LCS.NEr 267 DELEON RD RightSuReO thiversal2019 9213 POTOMAC DR DEBARY, FL 32713 19.0.17 R6U19927 PSL, FL 34981 Phone: 386-775-0908 Fax: 888-2625406 2020-Mar-30 14:11:49 www.energycaics.net MAGGIE@EhERGYCALCS.t wrloadslDRFIORTON1828CAI