HomeMy WebLinkAboutPool Information t
' Pentair TDH Calculator Page l of 2
File Copy
PENTAIR
TDH CALCULATOR HORIZON-WHEELER-HIGH SPEED
Pool Information
Flow Rate: 73.45 GPM Total Piping Lengths:
Suction Lift: 2 Ft Inlet Side: 72 Ft
Discharge Side: 90 Ft
Maximum Pipe Velocity Allowed: Piping Sizes:
(consult your local code) Inlet Piping: 2.052 In
Branch Piping: 6 Ft/Sec Discharge Piping: 2.062 In
Inlet Piping: 8 Ft/Sec Piping Head Loss at 73.45Gal/Min:
Discharge Piping: 8 FUSec
(not incuding fittings or valves)
Inlet Piping: 5.90 Ft
Discharge Piping: 7.38 Ft
For advanced pools that contain multiple suctions, this program may be
inaccurate. Consult a hydraulics engineer This program is for single pump
sytems with a single body of water.
Results: Your TDH Calculation
Suggested Minimum Pipe Sizes:
Flow Rate: 73.45 Gal/Min Branch Piping: 2.6 In
Your Head Loss: 47.99 Ft Inlet Piping: 2.0 In
Maximum Flow Rate Discharge Piping: 2.0 In
at Maximum RPM: 73.45 Gal/Min
Ensure the drain cover max flow rating is not
exceeded.
Head Loss at 47.99 Ft
Maximum Flow Rate:
System Head Pressure Curve
80
Q, so
0
�s
40 r -
20 - —
SuperFio VS-3450 rpm
Clean System �4
Desired Operation Point
0
0 25 50 75 100
Volumetric Flow Rate(GPM)
https://www.pentairpartners.com/marketing/tdh/index.aspx 5/9/2017
e
Pentair TDH Calculator Page 2 of 2
Selected Components V.0 CO
13y
Components
Head Loss at
ame uantity 73.45GaUMin
IntelliChlor IC-20 1 1.56
2 x 2.5 3 way valve 3 2.73
Main Drain 1 1.08
Clean and Clear 1 3.45
1/2 Inch Return 4 13.99
Piping
Inlet Discharge Head Loss at
ame uantity uantity 73.45GaUMin
90 degree elow 5 10 7.01
45 degree elow 1 8 1.92
Tee Through 0 3 0.98
Pumps
ame uantity
SuperFlo VS 1
All Pentair trademarks and logos are owned by Pentair, Inc. IntelliFlo®,IntelliComm@,EasyTouch@, IntelliTouch®,SunToucho,and Eco SelectT"
are registered trademarks and/or trademarks of Pentair Water Pool and Spa, Inc.and/or its affiliated companies in the United States and/or other
countries. Unless expressly noted,names and brands of third parties that may be used in this document are not used to indicate an affiliation or
endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the
trademarks or registered trademarks of those third parties.Because we are continuously improving our products and services, Pentair reserves the
right to change specifications without prior notice.Pentair is an equal opportunity employer.
https://www.pentairpartners.com/marketing/tdh/index.aspx 5/9/201 7
Pentair TDH Calculator Page 1 of 2
PENTAIR
File C'o
TDH CALCULATOR HORIZON-WHEELER-LOW SPEEDY
Pool Information
Pool Volume: 13800 Gal Total Piping Lengths:
Turn Over Time: 7.25 Hrs Inlet Side: 72 Ft
Suction Lift: 2 Ft Discharge Side: 90 Ft
Maximum Pipe Velocity Allowed: Piping Sizes:
(consult your local code) Inlet Piping: 2.052 In
Branch Piping: 6 Ft/Sec Discharge Piping: 2.062 In
Inlet Piping: 8 Ft/Sec Discharge Piping: 8 Ft/Sec Piping Head Loss at 31.72Gal/Min:
(not incuding fittings or valves)
Inlet Piping: 1.26 Ft
Discharge Piping: 1.56 Ft
For advanced pools that contain multiple suctions, this program may be
inaccurate. Consult a hydraulics engineer. This program is for single pump
sytems with a single body of water.
Results: Your TDH Calculation
Suggested Minimum Pipe Sizes:
Flow Rate: 31.72 Gal/Min Branch Piping: 1.5 In
Your Head Loss: 10.98 Ft Inlet Piping: 1.5 In
Maximum Flow Rate Discharge Piping: 1.5 In
at Maximum RPM: 73.46 Gal/Min
Ensure the drain cover max flow rating is not
exceeded.
Head Loss at 47.99 Ft
Maximum Flow Rate:
System Head Pressure Curve
15 _
2
010
�'C00
-
a
J �
SuperFlo VS-1600 rpm
Clean System ,
Desired Operation Point •`�
�!z l Q•�`q
Volumetric Flow Rate(GPM) .,
https://www.pentairpartners.com/marketing/tdh/index.aspx 5/9/2017
Pentair TDH Calculator Page 2 of 2
Selected Components
Components
Head Loss at
ame uantity 31.72GaUMin
IntelliChlor IC-20 1 0.41
2 x 2.5 3 way valve 3 0.18
Main Drain 1 0.33
Clean and Clear 1 0.56
1l2 inch Return 4 2.61
Piping
Inlet Discharge Head Loss at
ame uantity uantity 31.72GaUMIn
90 degree elow 5 10 1.48
45 degree elow 1 8 0.41
Tee Through 0 3 0.21
Pumps
ame uantity
SuperFlo VS 1
All Pentair trademarks and logos are owned by Pentair, Inc.IntelliFlo®,IntelliComm®,EasyTouch®, IntelliTouch®, SunTouch®,and Eco SelectTM
are registered trademarks and/or trademarks of Pentair Water Pool and Spa, Inc.and/or its affiliated companies in the United States and/or other
countries. Unless expressly noted,names and brands of third parties that may be used in this document are not used to indicate an affiliation or
endorsement between the owners of these names and brands and Pentair Water Pool and Spa,Inc. Those names and brands may be the
trademarks or registered trademarks of those third parties.Because we are continuously improving our products and services, Pentair reserves the
right to change specifications without prior notice.Pentair is an equal opportunity employer.
https://www.pentairpartners.com/marketing/tdh/index.aspx 5/9/2017
File Coy
_ y
1-M8 SOLUD BARE COPPER
18'MIN-24'MAX CONT.PERIMETER BOND
STAINLESS STEEL WIRE WITH APPROVED
HANDRAIL CLAMPS 4'TO 6'BELOW
(SAYE BONDING POR SUB-GRADE BOND TO
LADDER) ENDRE EQUIPMENT ALL-INMUND
PERIMETER ppOiS
.L ANCHOR WITH L
08 SOLID COPPER
BOND WIRE WITH
APPROVED CLAMPS 1-#8 SOLD BARE COPPER
BOND WIRE WITH APPROVED
Be SOLD COPPER g CLAMPS 0(4)SIDES OF
APPROVED AN
BOND WIDE LAMPS GUNIT BON E POOLS D TO
POOL STEEL
LIGHT NICHE
EQUIPOTENTIAL BONDING DETAIL
ELECTRICAL EQUIPMENT WIRING, GROUNDING PER FLORIDA BUILDING CODE ADAPTION
OF THE N.E.C. 2011 SEC. 680.26
AND INSTALLATION MUST CONFORM TO THE
2011 N.E.C. AND APPLICABLE LOCAL CODES
. SERVICE PANEL, TI2 V uGTmt OPTIONAL 2ND UGHT
JUNCTION-BOX(S)
•/P MIN OF 8'
DISCONNECT POOL TIMER W/S.T. J.B. ABOVE POOL DECK J.H.
RAP TOGGLE-SWITCH
G.l.l.
OPOOL DECK
NEC.APPROVED �
WATER PROOF G.F.I. 1'PVC CONDUT ...i.. i'�.�.
MUST NOT BE MORE
THAN 20'FROM POOL
EDGE AND NOT 3-/12 IN
WITHIN 6'OF POOL EDGE 1/2'CONDUIT
N.S.C. 2011 SEC. 680.22(3)
ELECTRICAL DETAIL
NOTE: ALL ELECTRICAL WORK SHALL
CONFORM TO N.E.C. 2011 SEC. 680