HomeMy WebLinkAboutProduct Approval 4/2812016 . Florida Building Code Online -
•, r3
`polo D°paarn.ent`l BCIS Home i Log In i User Registration Hot Topics 1. Submit Surcharge i Stats&Facts Publications FBC Staff BCIS Site Map i Links Search
I
Busines -
'jI it. Product Approval
Professi nal T.? USER:Public User
Regulation
Product Approval Menu>Product or Application Search>Application List>Application Detail
., r. FL# FL10674-R11
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829 i
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
,i
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Robert J.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017 Y
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
S
Certificate of Independence FL10674 R11 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year i
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008 i
i
Equivalence of Product Standards f
Certified By I
.i
Sections from the Code
,I
I
https://www.floridabuilding.org/pr/pr ppp OU.aspx?param=wGEVXQwtDgtBNbEY5V`/p2boQT°/p2b6w7ahReglCQ8ucR6ixEAOdgtxUj3osQ°/p3dp/o3d 1/2
4/2812016 .-- Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/20/2015
Date Approved 12/15/2015
Date Revised 04/18/2016
Summary of Products
FL# Model,Number or Name Description
10674.1 Owens Corning'Asphalt Roofing 3-tab, 4-tab, 5-tab, laminated, starter and hip&ridge
Shingles and Starters shingles
Limits of Use Installation Instructions
1 Approved for use in HVHZ: No FL10674 R11 II 2015 10 FINAL ER OC ASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-R11 odf
Impact Resistant: N/A Verified By: Robert]. M. Nieminen PE- 59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER, Section 5. Evaluation Reports
FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT
SHINGLES FL10674-Rll.Ddf
Created by Independent Third Party:Yes
Back Ncxt
Contact Us:: 1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(i),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter
455,F.S.,please dick here.
Product Approval Accepts:
® ®RR M
securitt•�tr:rkrtx
https:/twww.floridabuilding.org/pr/pr app o.aspx?param=wGEVXQwtDgtBNbEY5Vp/o2boQT`/`2b6w7ahRegfCQ8ucR6ixEAOdgtxUj3osQp/g3dg/gad 212
EXTERIOR RESEARCH&DESIGN, LLC.
i
�' Certificate of Authorization#9503
TRl�lllY ER® 353 CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R6
One Owens Corning Parkway FL10674-R11
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 6: 10/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable,rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 51h Edition (2014)Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LA6EuNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product.change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation .Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. if any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
'Prepared by:
Robertl.M.Nieminen,P.E.
Thefacs6nAeseala r,Fp�•.. ppearingivasauthoriiedtiyRobertNieminen
P.E.on10/15/7l115.This does not serve as an electronkally signed
Florida Registration No.59166,Florida DCA ANE1983 document Signed,sealed hardroptes have been transmitted to the
'CERTIFICATION OF INDEPENDENCE: Product Approval Administrator and tothe named client
1. TrinitylERD does not have,.nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen,P.E.are, in any'way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY i ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
\ Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1S07.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
Ent Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) ' Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
UL LLC(TST9628) Physical Properties Classification letter 10/02/2015
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic*and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire"are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration , Duration Premium Cool, TruDefinition® Duration Designer Color
Collection,Tru Definition*Oakridge,Oakridge'and WeatherGuard*HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire* Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge
Shingles,ProEdge Hip &Ridge Shingles and DuraRidgeTM Hip&Ridge Shingles are fiberglass reinforced,hip
and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R6
Certificate of Authorization#003 FL10674-R11
Revision 6:10/15/2015
Page 2 of 7
q`�, _'f:RINITY 1 ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for
us in all wind zones up to Vasd=150 mph(V„n= 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to Vasd= 150 mph (Vmt= 194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 611320-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval,or be Locally Approved per Rule 611320-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire'shingles require minimum five(5)nails per shingle. d
➢ WeatherGuard'HP shingles require minimum six(6) nails per shingle.
➢ Devonshirer"shingles require minimum six(6)nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck Felt undedaymerd Deck Sel-a here kb
Self-adhered u'do'tatm""t
WeatherLocka
underlayment j
Drip edge
Drip Drip edge Ddp---
edge edge
Naffs located
Wai{plocated trom em
2=3 from eave
Install first Self-sealing adhesive tnstalrirstStararSoipPlre Sir do e
Starter Strip positioned along eave whb g•removed
shingle with \
6"removed , Starter SSt p ploy overhangs eaves and rakes VC-3/4'
h-
Starlet Strip shingle overhangs eaves and rakes Vs
1
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certif/mte alAuthorization#9503 FL10674-R11
Revision 6:10/iS/2015
Page 3 of 7
TRINITY i ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
Normal Mansard or Area par& Normal Mansard or Area pan
Wind Areas High Wind dssv om y Wind Areas High Wind dasvenes y
Area pore vientos normales- Areas viontos fusms Area pore vientoa normales Areas vientos fusRss
�• IAI t�,�" �" z' B z' !72 tA) 21 r �• 2•
6"Exposure 6 5/8"Exposure
Exposici6n Exposiei6n
6.2.7 Minimum Nailing—Berkshire®:
sealant drip Eealara strip
La rka do sOtdx is Ira de sOla*r
sell
it Vf
r .
r
r
2" Asphalt rooting Cement
Cemento do teiho de astafto
6.2.8 Minimum Nailing—Devonshir6':
r - •�
Nails
Nails Ten t"Spots of Asphalt Hoof Cement
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-116
Certificate of Authorization#9503 FL10674-Rll
Revision 6:10/15/2015
Page 4 of 7
TRINITY !ERD
i
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition
Duration Designer Color Collection:
4 Nall Pattem 6 Nag Wmardard Stapetop
Esquema de 4 davos Wen when SunNa-
Pattern anaandlop o!cut out."
SureNaiP°t+steningareawldth �uelva t��aMa�
Area dodawsSuteNatl` • • • taaswlb�roparu
. rrgg e¢edeodel�¢ak.
.1• 1' arwwidln \ suftifa
Ostmtn
area w olh
� W Ana de P \
rbles of
Sun W 12' 17' S�e1'2iP
53e"Exposure Nails WExposure
614 pulg.de ezposlddn cbvos 6+b ping.de expo*,Wn
5%"Exposure Nails W Exposure
5%pulg.de exposkldn Davos 51h ping.de exposlddn
6.2.10 Minimum Nailing—TruDefinition Oakridge®,Oakridge®:
4 Nail Pattom 6 Nail Pattem
Esquema con 4 davos Esquema con 6 davos
t t
• t• t.
Imo-- tr
5 618'Exposure Nails 8 818" re Nags
brposlddade6618pulg. Claws �gande6618pufg• 65/8"Expasure WOWS 66f8"Ezposure
Exposld6n 66/8ptdi Expodd6n.de6619pedlg.
6.2.11 Minimum Nailing—WeatherGuard® HP:'
single$Me View
Wibjee111=l.
a> \•.
Chmm
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire*Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,WeatherGuard HP
Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle. installation of DuraRidgeTm.Hip &Ridge Shingles
shall comply with the manufacturer's current published instructions,using two(2) nails per shingle. Refer
to Owens Corning published information on wind resistance and installation limitations, including the use
of hand-sealing for wind warranties.
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6
Certi lcate of Authorization#9503 FL10674R11
Revision 6:10/15/2015
Page 5 of 7
TRINITY ER®
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R9O5.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
Fig.1 4 Fig.2
�— plevallnswna
i Dnepinn A TOPYiew SitleVlcw
I Nadc y A Nails Nails
4
I I r Top Lardnalai 2" 1
A i i 4- Piae
Ir t+j
I �IIPos�o 'II ¢¢I
ul
I
z
I
I
6.3.4 Minimum Nailing—Hip &Ridge with Sealant:
elm Fig. 2-High Wind Fastening Pattern
{4 Nails)rim Shin lie--}
nd Di:�card 2,r 2„
Excaess
Sealant --•
Strip 12"
'Fastening 55l$'Distance S"Exposu�
12 "
6.3.5 Minimum Nailing—WeatherGuard® HP Hip and Ridge:
ri
4
Fig.C Hip&Ridge Shingle Fastening
Fig.A
PtmaOYg ribtl TopVgw !
E-Dlt+xibn A ,�
A
Nail? 4 R tl
A i j Nails Nails
u
2" 2^ 1
r
I I {
�Eipowro +I
s' 'EYpo91R
���J i
I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
t:ertifimte oJAuthoriration#9503 FL10674-R11
Revision 6:20/15/2015
Page 6 of 7
i
\J
TRINITY 1 ERD
6.3.6 Minimum Nailing-ProEdge Hip&'Ridge Shingles:
Prevailing Standani
:VYind Direction Fastening
I;edent Strip Pattern W Espoeure 21
t2' i sea
lent
Fatm 7y,' 7'6' 6"�T e
Cove►Ellposed I
Fatsne with +
Roof Cement
6.3.7 Minimum Nailing—DuraRidg&m Hip&Ridge Shingles:
-Note: The drawings below pertain to minimum, as-tested attachment .requirements. Refer to Owens
Corning published installation instructions for their minimum requirements.
Pranihil Wild Dirockn Top Wev
t--Dirncion dornimnto d i mt voe en pin
Dirocdon del vionteOrodornimnto T44.1' visnngarior 1
I
x.. cam
N�lIai� ��. + ''QwemCaNnp9en=NaY
ir
mlij
I I '
.4 1
I
7. LABELING:
7.1 Labeling shall be in'accordance with,.the requirements the Accredited Quality'Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC "
Table 1507.2.7.1/R905.2.6.1:
8. BUILDING.PERMITREQUIREMENTS:
As required by the Building Official it Authority Having Jurisdiction in order to properly evaluate the installation of
'this product.
9. MANUFACTURING PLANTS:"
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA-
requirements.
:10. . QUALITY ASSURANCE ENTITY:
UL-LLC-QUA9625;(414)248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-R6
CertJfkote oJAuthorfzation#9503
FL10674-Rll
Revision 6:10/15/201s
Page 7 of 7
Chief Building Official April 12,2017
St Lucie County Building Department
2300 Virginia Avenue
Ft Pierce,FL 34982
Residence Bryant Residence
6391 Peterson Road
Fort Pierce, FL 34947
Subject: RAS-117 Nailing
The roofer may secure the CertainTeed Empire all-weather base sheet, for Systems Type
E (4)using 11 gauge annular ring shank nails and 1-5/8"dia. tin caps. The mechanical fastener
spacing is as follows:
Zone#1 (37 psf)—8" o.c. in the 4"lap and three rows, staggered, spaced 8"apart
@ 8" o.c.
Zone#2 (62 psf)—6" o.c. in the 4"lap and three rows, staggered, spaced 6" apart
@ 6"o.c.
Zone#3 (93 psf)—4"o.c. in the 4"lap and three rows, staggered, spaced 4"apart
@ 4"o.c.
All calculations are based on RAS-117 and the information contained in CertainTeed
NOA 14-0529.02, expiring 06/19/2018. These fastening patterns will meet the structural criteria
of the 2014 Florida Building code, 5d'. Edition, with a"C"exposure during a 170 mphult, 132
mph asd wind event. The cap sheet will be CertainTeed Flintlastic GMS.
If you have any questions, please call me at your convenience.
Thank.you -
Dr. rnest A. Kuonen,,PE 022920
President,_The ErningyCorporation CA-8327
228 Moccasin Trail, West
Jupiter, FL 33458