Loading...
HomeMy WebLinkAboutEvaluation Report; Flintlastic Modified Bitumen Roof SystemsQalwl wo 1 <f EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street TRINffY ERD Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT CertainTeed Corporation Evaluation Report 3520.03.04-1117 18 Moores Road FL2533-1116 Malvern, PA 19355 Date of Issuance: 09/19/2005 Revision 17: 02/04/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Flintlastic° Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 58-page Appendix. Prepared by: r�`_ RobertJ.IVI. Nieminen, P.E. p ^ The facsimile seal appearing was authorized by Robert Nieminen, ,%��C'' = t ;:•', .` P.E. on 02/04/2016. This does not serve as an electronicallysigned Florida Registration No. 59166, Florida DCA ANE1983 document g ., � •. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRI[rIITY ERD ' ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Flintlastic® Modified Bitumen Roof Systems, as produced by CertainTeed Corporation, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2004 1504.7 Impact FM 4470 1992 1507.11.2 Physical Properties ASTM D6162 2000 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2008 1507.11.2 Physical Properties ASTM D6509 2009 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) FM 4470 3504.06.01-1 06/05/2001 ERD (TST6049) FM 4470 3513.08.02 08/15/2002 ERD (TST6049) FM 4470 03515.07.03 07/22/2003 ERD (TST6049) FM 4470 3519.12.03 12/22/2003 ERD (TST6049) FM 4470/4474 3522.07.04 07/28/2004 ERD (TST6049) FM 4470/4474 02843.02.05-11 02/10/2005 ERD (TST6049) FM 4470/4474 3533.01.06 01/06/2006 ERD (TST6049) FM 4470/4474 4674.11.01-1 03/21/2006 ERD (TST6049) Physical Properties 3535.10.06 10/31/2006 ERD (TST6049) FM 4470/4474 3521.07.04-RS 10/26/2007 ERD (TST6049) FM 4470/4474 02764.09.05-R1 12/10/2007 ERD (TST6049) FM 4470/4474 02762.03.05-R1 12/10/2007 ERD (TST6049) Physical Properties C7290.01.08 01/16/2008 ERD (TST6049) Physical Properties C10080.09.08 09/04/2008 ERD (TST6049) FM 4470/4474 C8370.08.08-131 10/05/2009 ERD (TST6049) FM 4470/4474 P6860.06.07-R1 09/10/2009 ERD (TST6049) FM 4470/4474 C30310.12.09 12/17/2009 ERD (TST6049) FM 4470/4474 C30560.03.10 03/18/2010 ERD (TST6049) FM 4470/4474 C31420.08.10 09/21/2010 ERD (TST6049) FM 4470/4474 C33980.12.10 12/22/2010 ERD (TST6049) FM 4470/4474 C33830.02.11 02/08/2011 ERD (TST6049) TAS 117(B), Rupture C35500.02.11 02/09/2011 ERD (TST6049) FM 4470/4474 C37820.07.12 07/24/2012 ERD (TST6049) FM 4470/4474 C37830.07.12 07/26/2012 ERD (TST6049) Physical Properties C42110.08.12 08/13/2012 ERD (TST6049) FM 4470/4474 C39670.08.12 08/20/2012 ERD (TST6049) FM 4470/4474 C42280.08.12 08/20/2012 ERD (TST6049) TAS117(A) A35880.04.12-R1 10/26/2012 ERD (TST6049) FM 4470/4474 C44580.07.13 07/25/2013 ERD (TST6049) FM 4470/4474 C46090.11.13-A 11/20/2013 ERD (TST6049) FM 4470/4474 C45620.03.14 03/27/2014 ERD (TST6049) FM 4470/4474 C46760.06.14 06/19/2014 ERD (TST6049) FM 4470/4474 C47320.03.14-R1 04/01/2015 ERD (TST6049) FM 4470/4474 CTR-SC8995.10.15 10/14/2015 ERD (TST6049) FM 4470/4474 CTR-SC9935.01.16 01/14/2016 ERD (TST6049) FM 4470 CTR-SC9920.01.16-R1 01/20/2016 ERD (TST6049) FM 4470/4474 CTR-SC10420.01.16 01/25/2016 FM Approvals (TST1867) FM 4470 OE3A2.AM 03/30/1982 Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R37 Certificate of Authorization #9503 FL2533-R16 Revision 17: 02/04/2016 Page 2 of S °`� ,r TRINITY ERD ' - Entity Examination Reference Date FM Approvals (TST1867) FM 4470 3WOA4.AM 03/16/1993 FM Approvals (TST1867) FM 4470 3WOA2.AM 03/17/1993 FM Approvals (TST1867) FM 4470 3WOA3.AM 03/17/1993 FM Approvals (TST1867) FM 4470 1Z4A6.AM 09/11/1996 FM Approvals (TST1867) FM 4470 3Y8A1.AM 09/30/1996 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3009502 12/12/2000 FM Approvals (TST1867) FM 4470 3008869 03/19/2001 FM Approvals (TST1867) FM 4470 3009610 10/15/2001 FM Approvals (TST1867) FM 4470 3006025 12/28/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3009814 09/06/2002 FM Approvals (TST1867) FM 4470 3014502 04/04/2003 FM Approvals (TST1867) FM 4470 3015444 07/11/2003 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3018579 10/09/2003 FM Approvals (TST1867) FM 4470/4474 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3021759 06/03/2005 FM Approvals (TST1867) FM 4470/4474 3022038 04/05/2006 FM Approvals (TST1867) FM 4470/4474 3023458 07/18/2006 FM Approvals (TST1867) FM 4470/4474 3026128 08/04/2006 FM Approvals (TST1867) FM 4470/4474 3024311 11/01/2006 FM Approvals (TST1867) FM 4470/4474 3025766 11/13/2006 FM Approvals (TST1867) FM 4470/4474 3028410 02/19/2007 FM Approvals (TST1867) FM 4470/4474 3026964 07/25/2007 FM Approvals (TST1867) FM 4470/4474 3031262 11/30/2007 FM Approvals (TST1867) FM 4470/4474 3031199 12/23/2008 FM Approvals (TST1867) FM 4470/4474 3032172 06/12/2009 FM Approvals (TST1867) FM 4470/4474 3037127 01/11/2010 FM Approvals (TST1867) FM 4470/4474 3039848 12/02/2011 FM Approvals (TST1867) FM 4470/4474 3046104 08/13/2013 FM Approvals (TST1867) FM 4470/4474 3048520 09/19/2013 MTI (TST2508) Physical properties DX08C4A 03/22/2004 MTI (TST2508) Physical properties DX20E3A 03/22/2004 MTI (TST2508) Physical properties DX20E3A-001 01/04/2006 MTI (TST2508) Physical properties AX31G8A 08/21/2008 MTI (TST2508) Physical properties AX31G8D 09/05/2008 MTI (TST2508) Physical properties AX31G8F 06/05/2009 MTI (TST2508) Physical properties AX21G8C 01/28/2011 PRI (TST5878) Physical Properties CTC-032-02-01 01/16/2008 PRI (TST5878) Physical Properties CTC-034-02-01 11/24/2008 PRI (TST5878) Physical Properties CTC-066-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-067-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-068-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-070-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-071-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-093-02-01 08/08/2011 PRI (TST5878) Physical Properties CTC-116-02-01 04/03/2012 PRI (TST5878) Physical Properties CTC-183-02-01 10/04/2013 PRI (TST5878) Physical Properties CTC-259-02-01 12/11/2015 UL, LLC. (QUA9625) Quality Assurance Service Confirmation, R11656 Exp. 07/03/2017 4. PRODUCT DESCRIPTION: This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed Corporation published installation instructions and the Limitations / Conditions of Use herein. The following CertainTeed products make up the subject systems. Exterior Research and Design, LLC. Evaluation Report 3520.03.04-1117 Certificate of Authorization #9503 FL2533-1116 Revision 17: 02/04/2016 Page 3 of 5 . TRINITY ERD ABIi 1 R4LL G000sroa FlltVPIASTIC� Moor�r�c'Brrunn�tu'Roo> SYSTEMS Type Product Specification Reference Grade Type Base Sheets Flintlastic® SA NailBase ASTM D4601 N/A II Glasbase— Base Sheet ASTM D4601 N/A II All Weather/Empire'" Base ASTM D4601 N/A II Flexiglas'" Base ASTM D4601 N/A II Flintlastic" Base 20 ASTM D4601 N/A 11 Flintlastic Poly SMS Base Sheet ASTM D4601 N/A II Yosemite® Venting Base ASTM D4897 N/A II Ply Sheets Flintglas® Ply Sheet Type IV ASTM D2178 N/A IV Flintglas® Premium Ply Sheet Type VI ASTM D2178 N/A VI Base/Ply Membranes (APP) Flintlastic® APP Base T ASTM D6509 N/A N/A Flintlastic® STA ASTM D6222 S I Flintlastic® STA Plus ASTM D6222 S I Cap Membranes (APP) Flintlastic® STA ASTM D6222 S I Flintlastic® STA Plus ASTM D6222 S I Flintlasticm GTA ASTM D6222 G I Flintlasticm GTA CoolStar" ASTM D6222 G I Flintlastic® GTA-FR ASTM D6222 G I Flintlastic® GTA-F CoolStarT" ASTM D6222 G I ase PI Membrane SBS) Flintlastic SA P,IyBase ASTM D1970 N/A N/A ftiam a e eet ASTM D1970 N/A N/A Flintlastic SA Mid Ply ASTM D6163 S I Flintlastic Ultra Glass SA ASTM D6163 S 1 Flintlastic Base 20 ASTM D6163 S I Flintlastic Base 20 T ASTM D6163 S I Flintlastic Ultra Poly SMS Base Sheet ASTM D6164 S I dow Cap Membrane _ SBST Flintlastic FR Dual Cap ASTM D6162 G I Flintlastic _S"A Cap1R ASTM D6163 G I intt ic` ap R CoolStar" ASTM D6163 G I Flintlasti7 Cap 30 ASTM D6163 G I Flintlastic Cap 30 CoolStar'. ASTM D6163 G I Flintlastic FR Cap 30 ASTM D6163 G I Flintlastic FR Cap 30 CoolStarT" ASTM D6163 G I Flintlastic FR Cap 30 T ASTM D6163 G I Flintlastic FR Cap 30 T CoolStar•" ASTM D6163 G I Flintlastic SA Cap ASTM D6164 G I Flintlastic SA Cap CoolStarT" ASTM D6164 G I Flintlastic FR-P ASTM D6164 G I Flintlastic FR-P CoolStarT" ASTM D6164 G I Flintlastic GMS ASTM D6164 G I Flintlastic GMS CoolStarT" ASTM D6164 G I Flintlastic GTS ASTM D6164 G II Flintlastic GTS CoolStarT" ASTM D6164 G II Flintlastic GTS-FR ASTM D6164 G II Flintlastic GTS-FR CoolStarT" ASTM D6164 G II Flintlastic Premium FR-P ASTM D6164 G II Flintlastic Premium FR-P CoolStarT" ASTM D6164 G II Flintlastic Premium GMS ASTM D6164 G II Flintlastic Premium GMS CoolStarT" ASTM D6164 . G II S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R37 Certificate of Authorization #9503 FL2533-1116 Revision 17: 02/04/2016 Page 4 of 5 4 w...wO ..,_` TRINITY I ERa 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.8 For fully -adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.13 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Flintlastic® Modified Bitumen roof systems shall be installed in accordance with CertainTeed Corporation published installation instructions, subject to the Limitations / Conditions of Use herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (414) 248-6409, karen.buchmann@us.ul.com - THE 58-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 3520.03.04-1117 Certificate of Authorization #9503 FL2533-R16 Revision 17: 02/04/2016 Page 5 of 5