HomeMy WebLinkAboutEvaluation Report; Flintlastic Modified Bitumen Roof SystemsQalwl wo
1
<f EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 Christian Street
TRINffY ERD
Oxford, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
CertainTeed Corporation Evaluation Report 3520.03.04-1117
18 Moores Road FL2533-1116
Malvern, PA 19355 Date of Issuance: 09/19/2005
Revision 17: 02/04/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: Flintlastic° Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5, plus a 58-page Appendix.
Prepared by:
r�`_
RobertJ.IVI. Nieminen, P.E. p ^ The facsimile seal appearing was authorized by Robert Nieminen,
,%��C'' = t ;:•', .` P.E. on 02/04/2016. This does not serve as an electronicallysigned
Florida Registration No. 59166, Florida DCA ANE1983
document
g
., � •. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRI[rIITY ERD
' ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Modified Bitumen Roof Systems
Compliance Statement:
Flintlastic® Modified Bitumen Roof Systems, as
produced by CertainTeed Corporation, have
demonstrated compliance with the following sections of the Florida Building Code through testing in accordance
with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of
Use set forth herein.
2. STANDARDS:
Section
Property Standard
Year
1504.3.1
Wind FM 4474
2004
1504.7
Impact FM 4470
1992
1507.11.2
Physical Properties ASTM D6162
2000
1507.11.2
Physical Properties ASTM D6163
2000
1507.11.2
Physical Properties ASTM D6164
2005
1507.11.2
Physical Properties ASTM D6222
2008
1507.11.2
Physical Properties ASTM D6509
2009
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
FM 4470
3504.06.01-1
06/05/2001
ERD (TST6049)
FM 4470
3513.08.02
08/15/2002
ERD (TST6049)
FM 4470
03515.07.03
07/22/2003
ERD (TST6049)
FM 4470
3519.12.03
12/22/2003
ERD (TST6049)
FM 4470/4474
3522.07.04
07/28/2004
ERD (TST6049)
FM 4470/4474
02843.02.05-11
02/10/2005
ERD (TST6049)
FM 4470/4474
3533.01.06
01/06/2006
ERD (TST6049)
FM 4470/4474
4674.11.01-1
03/21/2006
ERD (TST6049)
Physical Properties
3535.10.06
10/31/2006
ERD (TST6049)
FM 4470/4474
3521.07.04-RS
10/26/2007
ERD (TST6049)
FM 4470/4474
02764.09.05-R1
12/10/2007
ERD (TST6049)
FM 4470/4474
02762.03.05-R1
12/10/2007
ERD (TST6049)
Physical Properties
C7290.01.08
01/16/2008
ERD (TST6049)
Physical Properties
C10080.09.08
09/04/2008
ERD (TST6049)
FM 4470/4474
C8370.08.08-131
10/05/2009
ERD (TST6049)
FM 4470/4474
P6860.06.07-R1
09/10/2009
ERD (TST6049)
FM 4470/4474
C30310.12.09
12/17/2009
ERD (TST6049)
FM 4470/4474
C30560.03.10
03/18/2010
ERD (TST6049)
FM 4470/4474
C31420.08.10
09/21/2010
ERD (TST6049)
FM 4470/4474
C33980.12.10
12/22/2010
ERD (TST6049)
FM 4470/4474
C33830.02.11
02/08/2011
ERD (TST6049)
TAS 117(B), Rupture
C35500.02.11
02/09/2011
ERD (TST6049)
FM 4470/4474
C37820.07.12
07/24/2012
ERD (TST6049)
FM 4470/4474
C37830.07.12
07/26/2012
ERD (TST6049)
Physical Properties
C42110.08.12
08/13/2012
ERD (TST6049)
FM 4470/4474
C39670.08.12
08/20/2012
ERD (TST6049)
FM 4470/4474
C42280.08.12
08/20/2012
ERD (TST6049)
TAS117(A)
A35880.04.12-R1
10/26/2012
ERD (TST6049)
FM 4470/4474
C44580.07.13
07/25/2013
ERD (TST6049)
FM 4470/4474
C46090.11.13-A
11/20/2013
ERD (TST6049)
FM 4470/4474
C45620.03.14
03/27/2014
ERD (TST6049)
FM 4470/4474
C46760.06.14
06/19/2014
ERD (TST6049)
FM 4470/4474
C47320.03.14-R1
04/01/2015
ERD (TST6049)
FM 4470/4474
CTR-SC8995.10.15
10/14/2015
ERD (TST6049)
FM 4470/4474
CTR-SC9935.01.16
01/14/2016
ERD (TST6049)
FM 4470
CTR-SC9920.01.16-R1
01/20/2016
ERD (TST6049)
FM 4470/4474
CTR-SC10420.01.16
01/25/2016
FM Approvals (TST1867)
FM 4470
OE3A2.AM
03/30/1982
Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R37
Certificate of Authorization #9503 FL2533-R16
Revision 17: 02/04/2016
Page 2 of S
°`� ,r TRINITY ERD
' - Entity
Examination
Reference
Date
FM Approvals (TST1867)
FM 4470
3WOA4.AM
03/16/1993
FM Approvals (TST1867)
FM 4470
3WOA2.AM
03/17/1993
FM Approvals (TST1867)
FM 4470
3WOA3.AM
03/17/1993
FM Approvals (TST1867)
FM 4470
1Z4A6.AM
09/11/1996
FM Approvals (TST1867)
FM 4470
3Y8A1.AM
09/30/1996
FM Approvals (TST1867)
FM 4470
2D5A9.AM
06/22/1999
FM Approvals (TST1867)
FM 4470
3009502
12/12/2000
FM Approvals (TST1867)
FM 4470
3008869
03/19/2001
FM Approvals (TST1867)
FM 4470
3009610
10/15/2001
FM Approvals (TST1867)
FM 4470
3006025
12/28/2001
FM Approvals (TST1867)
FM 4470
3012321
07/29/2002
FM Approvals (TST1867)
FM 4470
3009814
09/06/2002
FM Approvals (TST1867)
FM 4470
3014502
04/04/2003
FM Approvals (TST1867)
FM 4470
3015444
07/11/2003
FM Approvals (TST1867)
FM 4470
3014692
08/05/2003
FM Approvals (TST1867)
FM 4470
3014751
08/27/2003
FM Approvals (TST1867)
FM 4470
3018579
10/09/2003
FM Approvals (TST1867)
FM 4470/4474
3020703
07/30/2004
FM Approvals (TST1867)
FM 4470/4474
3021759
06/03/2005
FM Approvals (TST1867)
FM 4470/4474
3022038
04/05/2006
FM Approvals (TST1867)
FM 4470/4474
3023458
07/18/2006
FM Approvals (TST1867)
FM 4470/4474
3026128
08/04/2006
FM Approvals (TST1867)
FM 4470/4474
3024311
11/01/2006
FM Approvals (TST1867)
FM 4470/4474
3025766
11/13/2006
FM Approvals (TST1867)
FM 4470/4474
3028410
02/19/2007
FM Approvals (TST1867)
FM 4470/4474
3026964
07/25/2007
FM Approvals (TST1867)
FM 4470/4474
3031262
11/30/2007
FM Approvals (TST1867)
FM 4470/4474
3031199
12/23/2008
FM Approvals (TST1867)
FM 4470/4474
3032172
06/12/2009
FM Approvals (TST1867)
FM 4470/4474
3037127
01/11/2010
FM Approvals (TST1867)
FM 4470/4474
3039848
12/02/2011
FM Approvals (TST1867)
FM 4470/4474
3046104
08/13/2013
FM Approvals (TST1867)
FM 4470/4474
3048520
09/19/2013
MTI (TST2508)
Physical properties
DX08C4A
03/22/2004
MTI (TST2508)
Physical properties
DX20E3A
03/22/2004
MTI (TST2508)
Physical properties
DX20E3A-001
01/04/2006
MTI (TST2508)
Physical properties
AX31G8A
08/21/2008
MTI (TST2508)
Physical properties
AX31G8D
09/05/2008
MTI (TST2508)
Physical properties
AX31G8F
06/05/2009
MTI (TST2508)
Physical properties
AX21G8C
01/28/2011
PRI (TST5878)
Physical Properties
CTC-032-02-01
01/16/2008
PRI (TST5878)
Physical Properties
CTC-034-02-01
11/24/2008
PRI (TST5878)
Physical Properties
CTC-066-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-067-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-068-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-070-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-071-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-093-02-01
08/08/2011
PRI (TST5878)
Physical Properties
CTC-116-02-01
04/03/2012
PRI (TST5878)
Physical Properties
CTC-183-02-01
10/04/2013
PRI (TST5878)
Physical Properties
CTC-259-02-01
12/11/2015
UL, LLC. (QUA9625)
Quality Assurance
Service Confirmation, R11656
Exp. 07/03/2017
4. PRODUCT DESCRIPTION:
This Evaluation Report covers Flintlastic® Modified Bitumen Roof Systems installed in accordance with CertainTeed
Corporation published installation instructions and the Limitations / Conditions of Use herein. The following
CertainTeed products make up the subject systems.
Exterior Research and Design, LLC. Evaluation Report 3520.03.04-1117
Certificate of Authorization #9503 FL2533-1116
Revision 17: 02/04/2016
Page 3 of 5
. TRINITY ERD
ABIi 1 R4LL G000sroa FlltVPIASTIC� Moor�r�c'Brrunn�tu'Roo>
SYSTEMS
Type
Product
Specification
Reference
Grade
Type
Base Sheets
Flintlastic® SA NailBase
ASTM D4601
N/A
II
Glasbase— Base Sheet
ASTM D4601
N/A
II
All Weather/Empire'" Base
ASTM D4601
N/A
II
Flexiglas'" Base
ASTM D4601
N/A
II
Flintlastic" Base 20
ASTM D4601
N/A
11
Flintlastic Poly SMS Base Sheet
ASTM D4601
N/A
II
Yosemite® Venting Base
ASTM D4897
N/A
II
Ply Sheets
Flintglas® Ply Sheet Type IV
ASTM D2178
N/A
IV
Flintglas® Premium Ply Sheet Type VI
ASTM D2178
N/A
VI
Base/Ply Membranes (APP)
Flintlastic® APP Base T
ASTM D6509
N/A
N/A
Flintlastic® STA
ASTM D6222
S
I
Flintlastic® STA Plus
ASTM D6222
S
I
Cap Membranes (APP)
Flintlastic® STA
ASTM D6222
S
I
Flintlastic® STA Plus
ASTM D6222
S
I
Flintlasticm GTA
ASTM D6222
G
I
Flintlasticm GTA CoolStar"
ASTM D6222
G
I
Flintlastic® GTA-FR
ASTM D6222
G
I
Flintlastic® GTA-F CoolStarT"
ASTM D6222
G
I
ase PI Membrane SBS)
Flintlastic SA P,IyBase
ASTM D1970
N/A
N/A
ftiam a e eet
ASTM D1970
N/A
N/A
Flintlastic SA Mid Ply
ASTM D6163
S
I
Flintlastic Ultra Glass SA
ASTM D6163
S
1
Flintlastic Base 20
ASTM D6163
S
I
Flintlastic Base 20 T
ASTM D6163
S
I
Flintlastic Ultra Poly SMS Base Sheet
ASTM D6164
S
I
dow
Cap Membrane _ SBST
Flintlastic FR Dual Cap
ASTM D6162
G
I
Flintlastic _S"A Cap1R
ASTM D6163
G
I
intt ic` ap R CoolStar"
ASTM D6163
G
I
Flintlasti7 Cap 30
ASTM D6163
G
I
Flintlastic Cap 30 CoolStar'.
ASTM D6163
G
I
Flintlastic FR Cap 30
ASTM D6163
G
I
Flintlastic FR Cap 30 CoolStarT"
ASTM D6163
G
I
Flintlastic FR Cap 30 T
ASTM D6163
G
I
Flintlastic FR Cap 30 T CoolStar•"
ASTM D6163
G
I
Flintlastic SA Cap
ASTM D6164
G
I
Flintlastic SA Cap CoolStarT"
ASTM D6164
G
I
Flintlastic FR-P
ASTM D6164
G
I
Flintlastic FR-P CoolStarT"
ASTM D6164
G
I
Flintlastic GMS
ASTM D6164
G
I
Flintlastic GMS CoolStarT"
ASTM D6164
G
I
Flintlastic GTS
ASTM D6164
G
II
Flintlastic GTS CoolStarT"
ASTM D6164
G
II
Flintlastic GTS-FR
ASTM D6164
G
II
Flintlastic GTS-FR CoolStarT"
ASTM D6164
G
II
Flintlastic Premium FR-P
ASTM D6164
G
II
Flintlastic Premium FR-P CoolStarT"
ASTM D6164
G
II
Flintlastic Premium GMS
ASTM D6164
G
II
Flintlastic Premium GMS CoolStarT"
ASTM D6164 .
G
II
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in HVHZ jurisdictions.
5.3 Refer to a current Roofing Materials Directory for fire ratings of this product.
5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance
with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply.
Exterior Research and Design, LLC. Evaluation Report 3520.03.04-R37
Certificate of Authorization #9503 FL2533-1116
Revision 17: 02/04/2016
Page 4 of 5
4
w...wO
..,_` TRINITY I ERa
5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks shall be in
accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be
documented through proper codified and/or FBC Approval documentation.
5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1510.
5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure
for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to
resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies
marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3
enhancements.
5.8 For fully -adhered insulation, the maximum design pressure for the selected assembly shall meet or exceed
critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for
these systems
5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the
existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison
to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or
ANSI/SPRI FX-1.
5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If
any surface conditions exist that bring system performance into question, field uplift testing in accordance
with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124 shall be conducted on mock-ups of the proposed
new roof assembly.
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system
shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as
documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124.
5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC
Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind
speed shall be determined from FBC Figure 1609.
5.13 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Flintlastic® Modified Bitumen roof systems shall be installed in accordance with CertainTeed Corporation
published installation instructions, subject to the Limitations / Conditions of Use herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects
the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been
applied). Refer to FBC 1609 for determination of design wind loads.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (414) 248-6409, karen.buchmann@us.ul.com
- THE 58-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 3520.03.04-1117
Certificate of Authorization #9503 FL2533-R16
Revision 17: 02/04/2016
Page 5 of 5