Loading...
HomeMy WebLinkAboutEvaluation Report; V1 50 Series Picture & Fixed Window. BUILDING DROPS 398 East Dania Beach t Suite 338 A Perfect Solution in Every Drool Dania Beach, FL 33004 • Certificate of Authorization: 29578 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Of Silver Line Windows And Doors VI Series/50 Series Picture & Fixed Speacialty Window (2130) (Impact) (HVHZ) Method: 1— D (Engineering Evaluation) Category: Windows Sub — Category: Fixed Product: V1 Series/50 Series Picture & Fixed Window Material: PVC Product Dimensions: 53"x 73" Prepared for: t' Recelveo Silver Lane Building Products y ®� 1010 One Silverline Cyr. OCi North Brunswick, NJ 08902 Opermttttnu ieCo vmtq %Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date:10/19/17 Contents: Evaluation Report Pages 1-4 Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2017.1020 06:34:37-04'00' DES F. O % O 7 N,Al- F C� Herme01 P.E. Florida No. 73778 BUILDING DROPS Date: 10/19/2017 A Perfect Solution in Every Drop! Report No: 5226 Certificate of Authorization: 29578 Manufacturer: Silver Line Windows and Doors Product Category: Windows Product Sub -Category: Fixed Compliance Method: State Product Approval Method (1)(d) Product Name: VI Series/50 Series Picture & Fixed Window 53" x 73" Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Windows And Doors based on Method id of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SW13042, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing SWD042 require further engineering analysis by a licensed engineer or registered architect. S. See Installation Instructions SWD042 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 • ^6^A,) BUILDING DROPS Date: 10/19/2017 • A Perfect Solution in Every Drop! Report No: 5226 Certificate of Authorization: 29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Current Florida Building Code manufacturing under a quality assurance program audited by an approved quality assurance entity through Window and Door Manufacturers Association (FBC Organization #: QUA2515). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 • AAMA/WDMA/CSA 101/I.S.2/A440-11 • ASTM E1886-05 • ASTM E1996-12 Referenced Data: 1. Product Testing performed by Architectural Testing (FBC Organization # TST1558) Report: Dated: E5302.01-109-18 3/17/2015 E5302.02-109-44 3/17/2015 E5302.03-109-44 3/17/2015 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization #: QUA2515) 3. PVC profiles certified by AAMA in accordance with AAMA 303 4. Material Certification Miami Dade RER — Product Control Section NOA E.I. DuPont De Nemours & Co., Inc. Butacite PVB Interlayer Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 BUILDING DROPS Date: 10/19/2017 A Perfect Solution in Every Drop! Report No: 5226 Certificate of Authorization: 29578 Installation: 1. Approved anchor types and substrates areas follows: Nail Fin: A. For two by (2X) wood frame substrate, use #8 Wood Screws wood frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood framing. B. For metal stud substrate, use #8 Self -Tapping type metal stud anchors of sufficient length to achieve a minimum of 3 threads of penetration beyond metal structure. Throunh Frame: A. For two by (2X) wood frame substrate, use #10 Wood Screws wood frame anchors of sufficient length to achieve minimum embedment of 1.50" into wood framing. B. For concrete or masonry substrate where one by (1X), non-structural, wood bucking is employed, use 3/1V diameter ITW Tapcons type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete or masonry substrate where wood bucking is NOT employed, use 3/16" diameter ITW Tapcons type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. D. For metal stud substrate, use #10 Self -Tapping type metal stud anchors of sufficient length to achieve a minimum of 3 threads of penetration beyond metal structure. Refer to Installation Instructions (SWD042) for anchor spacing and more details of the installation requirements. Design Pressure: +/- 55 psf Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4 . 4 INSTALLATION NOTES: SILVER LINE WINDOWS AND DOORS 1. ONE (1) INSTALLATION ANCHOR 1S REQUIRED AT EACH ANCHOR LOCATION CHnwm 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OFANCHORS TO BE USED FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF ±1/2 INCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR LAYOUT DETAILS ME., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 3/81NCH. SHIM WHERE SPACE OF V16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. S. FIN INSTALLATION: FOR INSTALLATION INTO WOOD FRAMING USE N8 WOOD SCREWS OR 11 GAUGE ROOFING NAILS OR 10d COMMON HALLS OF SUFFICIENT LENGTH TO ACHIEVE 1.1/21NCN MINIMUM EMBEDMENT IN70 WOOD SUBSTRATE. V1 SERIES150 SERIES PICTURE & FIXED SPECIALTY WIND 0W (2130){IMPACT}(H VHZ) GENERAL NOTES 1. THE PRODUCT SHOWN HEREIN 15 DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT EDITION FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 • TAS 202.94 TAS 203.94 • AAMA/WDMA/CSA 161/1.5.2/A440.11 ASTM E-1896-OS • ASTM ELS96-12 6. FIN INSTALLATION: FOR INSTALLATION INTO METAL STUD USE 08 SEtf-TAPPING SCREWS, OF SUFFICIENT LENGTH TO ACHIEVE A MINIMUM OF 3 2. ADEQUACY OF THE EXISTING STRUCTURAL THREApS PENETRATION BEYOND METAL WALL. CONCRETE/MASONRY, 2X FRAMING, AND METAL. FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF 7. THROUGH FRAME INSTALLATION: FOR INSTALLATION THROUGH 1X BUCK TO WITHSTANDING AND TRANSFERRING APPLIED PRODUCT CONCRETE/MASONRY, OR DIRECTLY INTO CONCRETUMASONRY, USE 3/16 INCH LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE DIAMETER ITW TAPCONS OF SUFFICIENT LENGTH TO ACHIEVE 1.1/4 INCH ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF MINIMUM EMBEDMENT. INSTALLATION. 8. THROUGH FRAME INSTALLATION: FOR INSTALLATION INTO WOOD FRAMING USE 910 WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1-112 INCH MIWNIU -EMBEDMENT INTO WOOD SUBSTRATE. 9. THROUGH FRAME INSTALLATION: FOR INSTALLATION INTO METAL STUD USE !10 SELF -TAPPING SCREWS OF SUFFICIENT LENGTH TO ACHIEVE A MINIMUM OF 3 THNEA05 PENETRATION BEYOND METAL WALL. 10. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 11. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 12. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, 00 NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 13, INSTALLATION ANCHORS SHALL 8E INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 14. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.55. B. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF 30DO PSI; C. GROUT -FILLED CMU- UNIT STRENGTH CONFORMS TO ASTM G90 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI AND GROUT CONFORMS TO ASTM C 476, MINIMUM GROUT COMPRESSIVE STRENGTH OF 2000 PSt D. HOLLOW BLOCK CMU -UNIT STRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI, E. STEEL- MINIMUM YIELD STRENGTH OF 33 KSI. MINIMUM WAL£.THSCKNESS OF 35.9 MIL (0.0478" or 18 GAUGE). MIN. 1/2" EDGE DISTANCE:. F. ALUMINUM -MINIM UMALLOY6063-TS.MINIMUMYVALLTHtXNESSOF 1/16". MIN.1/2" EDGE DISTANCE. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE, BUCK DESIGN AND INSTALLATION 15 THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZ AREAS, IN HVHZ AREAS, ONE TIME PRODUCT APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR AM. 5, APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: PVC 7. IN ACCORDANCE WITH THE CURRENT EDITION FBC, WOOD COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN CHAPTER23,. 8, GLASS MEETSTIIE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 4 FOR GLAZING DETAILS. TABLE OF CONTENTS SECTION I REVISION SHEET DESCRIPTION 3 - INSTALLATION & GENERAL NOTES 2 - ELEVATION & ANCHOR LAYOUTS 3 - VERTICALSECTIONS 4 HORIZONTAL SECTIONS & GLAZING MINIS 5 BILL OF MATERIALS &COMPONENTS DESIGN PRESSURE TABLE OVERALL SIZE DESIGN PRESSURE MISSILE IMPACT RATING WIDTH HEIGHT S3" 1 73" -55 /-SS PSF LARGE & SMALL MISSILE IMPACT _ Silver Lim �a x3iH.."t SILVER JE LIN E �?anuxsvAcrrn casot m(owl 134. , 218 cz� s" n K % r I 0Q;i wet .a tl3A a OU Z � CL tnho O r ym gm �tCN F m r `a a m vgne4 by HF. Narera. PE I arGaWla�A41R$eb.S�:mect T T O I. toe k aaxu atwl aaaa F ur t38 bu+u Aua iL N Leaf uNt tx lQeurm aa N. soars FL R: FL17767 DATE: 1 l SCALE: NTS Dwc. m WIMA 7 I OF 5 MAX. FRAME WIDTH 53.00" F I D.L.O. MAX WIDTH 48.50"- 3 3 - F 4 MM. FRAME HEIGHT 73.00" D.L.O. MAX. HEIGHT 5 .50" ELEVATION all MAX. FROM --�{ 14" MAX. CORNERS I �... � O.C. 1 14" O.C. f 8" MAX. J FROM CORNERS ANCHOR LAYOUT FINLESS 2" MAX. FROM CORNERS i 1-. 10" MI U.C. f 2" MAX. FROM CORNERS j-_ (W_)__ j t ; f TI (N) ' II+H} JJ (H) �'�� (H) �// (+HI) L__ _-J --j (W) I-- f (W)� I I i--(W)--) r—(W)—� �~—(W)---j IE lH) J f T—. _ .___� T ____ E ` i '� `--- i T I i (H) lL lL � � E lHI L �J `t .L UNITS OF THE SHOWN SHAPES ARE ALLOWED PROVIDED CONSTRUCTION, GLAZING, A, ANCHORAGE ARE PER DETAILS SHOWN HEREIN. ALL SHAPED UNITS SHALL FIT WITHIN THE RECTANGULAR AREAS AS SHOWN. MAXIMUM W = 53" MAXIMUM H = 73" MAXIMUM DP = +J- 55 PSF —1. MAX. O.C. ANCHOR LAYOUT _ ._......... _............—FIN (W) 1-1 (H) I (W) 1 1 L (H) T NOTE.;._ ._. .. ... WINDOW WIDTH (W) AND HEIGHT (H) ARE INTERCHANGEABLE FOR ALL SIZES SHOWN HEREIN NOT TO EXCEED MAXIMUM TESTED SQUARE FOOT AREA. ANCHOR SPACING SHALL NOT EXCEED THOSE SHOWN FOR LONG OR SHORT LEG OF UNIT: Silver Line ... biMdrrroffi E. B ONE 500WIEDR,.^JE KORIN BReiliSYhQi. fliON901 V �oN5 9j w'S re0 0.1-j4t 07'^--y W QUm S: a�sgg�i n3� m Qwv��d wwo0`� •m Jn W w h 6 IA•61HF5CEOIT1CN IAR 110.16.171 `f;ffffl it111j17 *�¢ 7 - o TPT it WA 6E . F1 3 3 M f[92 MT. OF F.UI MUPOK Nw 99178 FL p: FL17767 DATE: 10.16.17 j SCALE: NTS DWG.N: SWIV42 2 OF 5 • r N10 WOOD SCREW 3/4" MIN. INSYALLAFlON ANCHOR —..�j MIN. 3 THREADS Silver Line IaAndeis'en CONCRETE MASONRY EDGE DISTANCE I METAL STUD BY OTHERS, PENETRATION �' BEYOND METAL BYOTHERS A % • SEE SHEET I INSTALLATION NOTE 14 "*--..� STRUCTURE CAULK BETWEEN • ° CONCRETEBnYOTHERS ° ° 128SELF-TAPPING SCREW INSTALLATION ANCHOR 3J8"MIN. , ONESILPERWEnRSE IN 6tJYStl^.Q, sat 2X WOOD BUCK/STUD— BY OTHERS 1 1/2. MIN. EXTERIOR FINISH & SHEATING� BY OTHERS GE pO TANCE o-x: sm zsT•.: ]® EXTERIOR FINISH EMBEDMENT BACKER ROD & SEALANT BY OTHERS. - u BY OTHERS .. 0 N T 4"MAX. J PERIMETER SEALANTHIM SPACE / 1/4" M� _ SHIM SPACE $ ? T z S w a Y BY OTHERS ( d � G � E7 = � O.A. 2 r O.A.UNIT UNIT /':3 vy w `.HEIGHT HEIGHT N H $ is m^ $EE GLAZING SEE GLAZING DETAIL,SHEET4aEXTERIORERIOR cc N wDETAIL,SHEET4 EXTERIOR INTERIOR ° REMARKS BY DATE A 6TH M ENT N AR 10.161 VERTICAL SECTION _. VERTICAL SECTION _ '. ` ixWOODBUCK T HEAD•METAISTUD FIN INSTALLATION ,x>wuixc. ew vco;mR:xwi.aiear.R<� wn oJrwancx:a•urro•unnwvLn,e.. •LT<ATRx4>aP UPb.^Y.:tM1MilRxw UAOf:+f+ Wat \LSTU Ix SJCfUN[Nf 41E xUT YrYdIRUA'A 4At• AYE Altt+' TtOv FINLESS INSTALLATION EXTERIOR INTERIOR EXTERIOR INTERIOR ``t`0tilF 1114",�', NOTE: IX WOOD BUCK �e� Q�� SEE GLAZING BY OTHERS IS OPTIONAL SEE DETAIL, GLAZING DETAIL, SHEET 4 FOR MASONRY APPLICATIONS, SE 7. DETAIL E/4, zg$ O.A. O.A. * ! ? UNIT UNIT / \ '" 'b T T a HEIGHT / 3 HEIGHT ( 1 3 p W 1/4" MAX. ��'� L 2�C t �k' / 1 1/a°Max. . F` •••....... G . U J a SHIM SPACE 2 I r SHIM SPACE s`S/OPjJ�t rtaaoA vc w 73na autmc mc°s trot PERIMETER SEALANT OTHERS BACKER ROD & 3/4"MIN. +aa c DANu DMA CK u EDGE DISTANCE evn.� ax SEALANT BY OTHERS _ FVE omrE wiraanai na. veeTa EXTERIOR FINISH a 1 1/4" MIN. j_ BY OTHERS ° EMBEDMENT EXTERIOR FINISHr- 1 FLN: BY OTHERS F L17767 CONCRETE/MASONRY SILL + I 2X WOOD BUCK/STUD —' " BY OTHERS , I BY OTHERS DgTE: 1'ft" MIN. SHEATHING 10.16.17 3/16" ITW TAPCON EDGE DISTANCE BY OTHERS EMB 1, MIN. DWG. BY: CHK. BY: INSTALLATION ANCHOR N8 WOOD SCREW, OR 11 GAUGE AR I H FN ROOFING OR 10d COMMON NAIL SCALE: NTS VERTICAL SECTION INSTALLATION ANCHOR (� VERTICAL SECTION SILL - ZX WOOD FRAME I)—.;,: SWD042 SILL-CONCRETE/MASONRY FIN INSTALLATION SHEET FINLESS INSTALLATION ^( OF 5 1-1/4" MIN. EMBEDMENT 1/4-'MAX. CAULK BETWEEN SHIM SPACE CONCRETE/ MASONRY & 1X WOOD BUCK BY OTHERS CONCRETE/MASONRY v BYOTHERS1� INTERIOR 1X WOOD BUCK (OPTIONAL) 4 BY OTHERS 3 SEE GLAZING `DETAIL 1 }4" EDGE DISTANCE t 3/16" ITW TAPCON INSTALLATION 2 ANCHORS EXTERIOR ............. EXTERIOR FINISH CIA. BY OTHERS UNIT WIDTH PERIMETER SEALANT BY OTHERS HORIZONTAL SECTION JAMB • CONCRETE/MASONRY FINLESS INSTALLATION SitverLEr>e 31W, MIN. Andes' EDGE DISTANCE 1/4" MAX. SHIM SPACE CAULK BETWEEN ONC51[V•gU'ILDA4YE NtlRiN ggUNlt'dll, N168"r�11 CONCRETE/ MASONRY & 2X WOOD BUCK BY OTHERS INTERIOR i CONCRETE/ MASONRY w Z �!� BY OTHERS 2X WOOD BUCK/STUD BY OTHERS Z o z o SEE GLAZING 1 [[I � b u F t7 X s� DETAIL 3 4 � 0 9 gal k Y h w � ? \ 11/2'. MIN. ' ts. '- N C w i EMBEDMENT `N` M m q8 WOOD SCREW, OR 11 GAUGE C- a EXTERIOR ROOFING OR lod COMMON NAIL 2 INSTALLATION ANCHORS REMARKS BY DATE O.A. EXTERIOR FINISH A•6TH FBC 10MON AR ID66.1' UNIT BY OTHERS WIDTH BACKER ROD & SEALANT BY OTHERS anas•:uarm ecucxoomwmw.c:[cnrnn-� rF' _ HORIZONTAL SECTION rwmnu svc.uvra:ls,pvaoraxa.: ,L [>a[ca:t•aorrPrs. .Llosc,rtn.almn[a xu[<nrs n r Ns eacuvcw uE vor Ptxvm[a ua JAMB -WOOD BUCK FIN INSTALLATION ,LLTL 1111I t J1 J O 3/4" MA, I.G. LAMINATED GLASS CONSISTING OF: 1/8" ANNEALED GLASS, /4" SUPER SPACER, 5/32" ANNEALED GLASS 0.090" BUTACITE PVB INTERLAYER BY DUPONT, 5/32" ANNEALED GLASS EXTERIOR INTERIOR 2 / O MIN. GLASS i 0 BITE9/16" / 1/6" S_�'ITING BLOCK 1 \ %DOW 995 SILICONE GLAZING DETAIL �• .O ±�•: TT ?� N-4! AW.13"e Fl. P.[. No 7M . .. - am" mml'A Wa 7P0 C. K 6LAQ1 V. P sm NNN Aum rA FOR C4RC gp /�UrNOaU1W1 Na C!!tB NOTE: Fla: 1) FIXED GLASS LITES GREATER THAN 36" IN WIDTH SHALL HAVE F L17767 TWO APPROVED SETTING BLOCKS AS SPECIFIED IN FBC CHAPTER24. j DATE: 10.16.17 2) FOR INSTALLATION ABOVE 30 FT. ABOVE GRADE IN AREAS REQUIRING IMPACT RESISTANCE, ALL UNITS MUSTSAFETY BE uwGAR �HKHFN GLAZED OR COVERED BY AN IMPACT PROTECTIVE SYSTEM PER 1. FBC CHAPTER 24. SCALE: NTS DwG. a: S W D042 SHEET 4 OF 5