Loading...
HomeMy WebLinkAboutConstruction PlansFERRIN CLIENT: DOLLAR GENERAL LOCATION: FT PIERCE, FL. DESIGN #1120018 SIGNS SATES: D. MA20 SALES: D. MAY Y I. PRO DESIGN POSAL' DESIGNER: J. LUZURIAGA SCALE: AS NOTED DISK:DRAW 2020 DATE: _�'+INjry�4 REVISIONS 4 . FT .•.0 a ,. �JIIDI S � ` REAR ZNG. _ d � a Install 1 Internally illuminated aluminum cabinet wall sign. North elevation: N.T.S. (Z _ C-4c>7S SIGN TO BE LISTED AS PER N.E.C. 600.3 ALL COMPONENTS TO BE U.L. LISTED & APPROVED ALL FABRICATION & USE OF SAID COMPONENTS TO MEET OR EXCEED LOCAL & N.E.C. REQUIREMENTS REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY B®CC THIS DRAWING WAS CREATED TO ASSIST YOU IN VISUALIZING OUR PROPOSAL. THE ORIGINAL IDEAS HEREIN ARE THE PROPERTY OF FERRIN. PERMISSION TO COPY OR REVISE THIS DRAWING CAN ONLY BE OBTAINED THRU A WRITTEN AGREEMENT WITH FERRIN, SEE YOUR SALES REPRESENTATIVE OR CALL THE OFFICE OF FERRIN SIGNS INC. L LIFTING ANGLE HINGE JTOP VIEW SCALE 1:40 26'-0" (18) STL. MOUNTING ANGLE BRACKET W/ 1/2" DIA. MOUNTING HOLES FRONT VIEW SCALE 1.40 1'-10" 2'-6 11/16" 2'-6 11/16" 2'-6 11/16" 3'-2" T-9 7/8" 2'-6 11/16" 2'-6 11/16" 2'-6 11/16" 1'-10" r ELECTRONIC FLUORESCENT 1 BALLAST LAMP - - 7/8" DIA. ELECTRICAL �L (18) STL. MOUNTING ANGLE BRACKET ROUTE HOLE W/ 1/2" DIA. MOUNTING HOLES CABINET SEAM USE 3/8" DIA. FASTENERS FOR 3/8" DIA. FASTENER TO ASSEMBLE LHS & RHS CHASSIS 13'-0" 13'-0" - FRONT VIEW W/O FACE SCALE 1:40 WEEP HOLES C` GENERAL NOTES_" INCLUDE COMPLETION PHOTOS OF MOUNTING/CONNECTION POINTS, WALL MOUNT AND WELDING CONNECTIONS IF APPLICABLE. LIFTING BRACKET THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRONIC BALLAST ELECTRIC CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. SIGN SPECS OVERALL DIMENSIONS OF SIGN: SIGN FACE HEIGHT: 45" WIDTH: 312" DEPTH WITH FACE: 7 11/16" LAMPS: (4) F96T72 CW/HO (4) F84T12 CW/HO (8) F72T12 CW/HO BALLAST: (4) EESB-832-16L 9.6 AMPS @ 120VAC FLUORESCENT LAMP (1) 20 AMP CIRCUIT, 60 Hz UL 48 & NEC COMPLIANT SIGN IS TO BE WIRED WITH 12 GAGE MTW WIRE. SIGN MUST BE GROUNDED WITH 12 GAGE GREEN WIRE. (1) 7/8" DIA. ELECTRICAL INLET (INSTALLER TO PROVIDE UL LISTED CONDUIT, FITTINGS AND MOUNTING HARDWARE) CONT. BLOCKING (BY G.C. AS REQUIRED, SEE INSTALLATION INSTRUCTIONS) MOUNTING ANGLE BRACKET (18) PVC/STEEL SLEEVE TO PROTECT WALL FINISH (IF REQUIRED) (18) 3/8" DIA.THREADED ROD NUTS & WASHERS (TYPE & LENGTH IS DEPENDENT ON WALL CONSTRUCTION & T.B.D. BY INSTALLER ON SITE) SEAL ALL PENETRATIONS PER NEC CODE BUILDING FRAME INSTALLATION INSTRUCTIONS 1. WALL CABINET IS SHIPPED AS TWO PIECES. ENSURE FACES ARE BUTTED UP AGAINST EACH OTHER TO APPEAR SEEMLESS. THIS WILL AVOID RETURNING TO SITE TO ADJUST FACES AT INSTALLER COST. 2. OPEN PACKAGING CAREFULLY AND INSPECT FOR DAMAGE. VERIFY SIGN TEMPLATE IS IN BOX. IF DAMAGE IS FOUND, CLAIM MUST BE FILED WITHIN 15 DAYS WITH SHIPPING AGENT. 3. 8 MOUNTING ANGLE BRACKETS ARE SUPPLIED BY EVERBRITE. BRACKETS WILL BE MOUNTED TO CRATE HOLDING THE SIGN IN PLACE. BRACKETS MUST BE MOUNTED TO WALL PER SECTION VIEW. 4. DETERMINE SIGN PLACEMENT BY REFERING TO ELEVATION/OVERLAY DRAWINGS. ADHERE TEMPLATE TO THE SURFACE TO WHICH THE SIGN WILL BE INSTALLED. 5. LAYOUT AND PER -DRILL ALL MOUNTING AND ELECTRICAL HOLES REQUIRED FOR MOUNTING THE SIGN ON THE WALL AS IT IS TO BE INSTALLED PER ELEVATION DRAWINGS. 6. ATTACH STEEL ANGLE MOUNTING BRACKETS TO WALL WITH APPROPRIATE MOUNTING HARDWARE, SUPPLIED BY INSTALLER. ALL FASTENERS SHALL BE ZINC COATED TO PREVENT CORROSION UNLESS NOTED OTHERWISE. 7. ALL WALL PENETRATIONS SHALL BE SEALED TO PREVENT WATER INFILTRATION. EVERBRITE RECOMMENDS FILLING HOLES WITH SILICONE PRIOR TO INSTALLING HARDWARE. 8. IF THE MOUNTING STRUCTURE HAS A VARYING SURFACE (I.E. METAL PANEL), SHIMS MAY BE REQUIRED TO PROVIDE UNIFORM MOUNTING SURFACE. 9. IF THE STRUCTURE CANNOT PROPERLY SUPPORT THE SIGN, THE G.C. SHALL INSTALL UNISTRUT, 2X, ANGLE OR OTHER APPROPRIATE BLOCKING BEHIND THE SURFACE TO PROVIDE PROPER SUPPORT FOR THE SIGN. 10. THREADED ROD FASTENERS MAY BE REQUIRED TO REACH SUBSTRUCTURE OR INSTALLED BLOCKING (THE INSTALLER IS RESPONSIBLE FOR DETERMINING THE PROPER LENGTH OF THREADED ROD). 11. IF THE MOUNTING SURFACE IS BRICK, USE AT LEAST 3/8" DIA HILTI HLC SLEEVE ANCHOR WITH A MINIMUM OF 1 1/4" EMBEDMENT. 12. THREAD ONE END OF THE FASTENER/THREADED ROD THROUGH THE BACK OF THE CABINET JUST FAR ENOUGH TO APPLY THE WASHER AND NUT BUT NOT FAR ENOUGH TO TOUCH THE LAMPS ON THE INSIDE OF THE CABINET. 13. PUSH THE CABINET, WITH THE FASTENERS/THREADED RODS EXTENDING OUT THE BACK, THROUGH THE PRE -DRILLED MOUNTING HOLES AND SECURE WITH HARDWARE. 14. EACH WALL CABINET SIGN REQUIRES A DEDICATED 20 AMP CIRCUIT. 15. MAKE FINAL ELECTRICAL HOOKUP TO PRIMARY WIRING PER NATIONAL ELECTICAL CODE AND IF NEEDED PROVIDE WEATHER PROOK BOX, SUPPLIED BY INSTALLER. EVERBRITE SUPPLYS A 4' ELECTRICAL WHIP. 16. TEST THE SIGN TO ENSURE THE SIGN IS LIGHTED AND FUNCTIONING PROPERLY. 17. PERFORM TOUCH UP AS REQUIRED. ALL EXPOSED FASTENER HEADS SHALL BE PAINTED TO MATCH EXTERIOR CABINET. COLOR IS SEMI GLOSS BLACK. C REVISED ELECTRICAL SPECS B REVISED INSTRUCTIONS A RELEASED FOR INSTALL EV. DESCRIPTION WALL FINISH OVER SHEATHING (INSTALLER TO IDENTIFY TYPE & THICKNESS) WALL MOUNT DET EVIE 13% FOR SCALE 1:10 CD®COMPLIANCE S` . LUCIE COUNTY SIGN TO BE CONSTRUCTED TO 2014 NEC 600 STANDARD SIGN TO BEAR UL LABEL SIGN TO HAVE ELECTRICAL DISCONNECT ON THE EXTERIOR FLORIDA BUILDING CODE 6TH EDITION (2017) SECTION 16 WIND LOAD ASCE 7-10 160 MPH WIND LOAD RISK CATEGORY II EXPOSURE C DWG TITLE SITE DG08736 7-7-15 SAJ RHB DOLLAR GENERAL T-T SAJ X 3-19-14 ��AS SHOWN 10GO SIGN OWN R - WALL MOUNT 8736 FORT IRGINIA AVE/SR FL 381 0 9-18-14 SAJ RHB DRAWN BY DATE /� SCALE DWG NO. REV. 4-4-14 SAJ RHB CHK'D BY DATE PIF REF DATE DRN CHK RHB 4-4-14 302864 I N 04326 B C ENCON SERVICES, INC. P.O. BOX 3613 APOLLO BEACH, FL 33572 813-655-3373, FLEB #9394 ENCON@ME.COM , W N P. PRF''�'''�. E No 77G •• •ice 'p • • ATE OF NATHAN P. PRESNELL, PE 77696 DATE SIGNED: 9/24/2020 o ��O ° o "0000 O000• 4949 SO. 110TH ST. 0000 0000. P.O. BOX 20020 0900 o00^ GREENFIELD, WI 53220 ° 00 000 00 0 414529-3500 °° °