HomeMy WebLinkAboutEngery CalcsEnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 42/2/2021 10:42 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: 66100 Port St. Lucie Wade Jurney Homes7106 Paso Robles Blvd - 1449 B LHG - S Street: City, State, Zip: , FL , 7106 Paso Robles Blvd Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 1449 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Dbl, U=0.35 105.00 ft² SHGC=0.29 N/A f t ² N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1449.00 ft² R=f t ² R=f t ² 10. Wall Types a. Frame - Wood, Exterior R=13.0 1096.00 ft² b. Frame - Wood, Adjacent R=13.0 304.00 ft² c. N/A R=f t ² 11. Ceiling Types a. Under Attic (Vented)R=30.0 1449.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Main, AH: Main 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.857 ft. Area Weighted Average SHGC:0.290 Description Area Insulation Area Insulation Area Insulation Area 16. Credits Pstat 4 (105.0 sqft.) (1400.0 sqft.) (1449.0 sqft.) (1449.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Heat Pump k B t u / h r 22.2 SEER:14.50 Efficiency k B t u / h r Efficiency 22.2 HSPF:8.20 f t ² R 6 289.8 EF: 0.920 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.072 Total Proposed Modified Loads: Total Baseline Loads: 41.71 44.02 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 02/02/2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: 66100 Port St. Lucie Wade Jurney Homes 1 7106 Paso Robles Blvd - 144 Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 1449 4 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , , St. Lucie 7106 Paso Robles Blvd Lakewood Park Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_AIRPORTFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Block1 1449 11592 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 Main 1449 11592 Yes 5 4 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS R-ValueSpace Perimeter 1 1449 ft² 0.29 0 0.71______ Slab-On-Grade Edge Insulatio - - - -0137 ft Main # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Gable or Shed Composition shingles 1527 ft² Dark 0.4 0 18.4______N242 ft² 0.4 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 1449 ft² N N300 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 1449 ft² 0.1 Wood______Main Blown 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 13 0Main00037 8N Frame - Wood 0.40.25Exterior296.0 ft² ____ 2 13 0Main00650 8E Frame - Wood 0.40.25Exterior404.0 ft² ____ 3 13 0Main00616 8S Frame - Wood 0.40.25Exterior132.0 ft² ____ 4 13 0Main00033 8W Frame - Wood 0.40.25Exterior264.0 ft² ____ 5 13 0Main00038 8- Frame - Wood 0.40.25Garage304.0 ft² ____ # Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .4 17.8 ft² None______ N Main 8682 2 Insulated .4 20 ft² None______ S Main 863 3 Wood .46 17.8 ft² None______ - Main 8682 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 N Low-E Double 0.35 0.29 45.0 ft² 1 ft 0 in 1 ft 0 in Drapes/blindsVinyl None______Yes1 N 2 E Low-E Double 0.35 0.29 15.0 ft² 1 ft 0 in 1 ft 0 in Drapes/blindsVinyl None______Yes2 N 3 S Low-E Double 0.35 0.29 30.0 ft² 4 ft 0 in 1 ft 0 in Drapes/blindsVinyl None______Yes3 N 4 W Low-E Double 0.35 0.29 15.0 ft² 1 ft 0 in 1 ft 0 in Drapes/blindsVinyl None______Yes4 N # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 418 ft² 418 ft² 46 ft 8 ft 1______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1352.4 774.2.000356Wholehouse .1263139.3Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Heat Pump/HSPF:8.2 22.2 kBtu/hr ______sys#1Split1 Singl # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 14.5 22.2 kBtu/hr 666 cfm 0.75______sys#1Split1 Singl 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.92 50 gal 70 gal 120 deg None______ None Main FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 289.8 ft Main 72.45 ft Default Leakage Main ( D e f a u l t ) ______1 1 ( D e f a u l t ) TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Main 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods Florida Building Code, Energy Conservation, 7th Edition (2020) ADDRESS: 7106 Paso Robles Blvd , FL , Permit Number: The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. MANDATORY REQUIREMENTS - See individual code sections for full details. R402.4 Air leakage (Mandatory). During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. R401.3 Energy Performance Level (EPL) display card (Mandatory). 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 R402.4.3 Fenestration air leakage. R402.4.1.1 Installation. Exception: Site-built windows, skylights and doors. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight-fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. Exception: R402.4.1.2 Testing. R402.4.1 Building thermal envelope. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer’s instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. SECTION R401 GENERAL SECTION R402 BUILDING THERMAL ENVELOPE MANDATORY REQUIREMENTS - (Continued) Building framing cavities shall not be used as ducts or plenums. Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. If heated water circulation systems are installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 R403.3.5 Building cavities (Mandatory). R403.4 Mechanical system piping insulation (Mandatory). R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). SECTION R403 SYSTEMS R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be “substantially leak free” in accordance with Section R403.3.3. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer’s air handler enclosure. Registers shall be taped or otherwise sealed during the test. Rough-in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer’s air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. 1. Exceptions: A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. 2. 1. R403.1 Controls. R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer’s designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. 1. 2. R403.5.1.1 Circulation systems. R403.5.1.2 Heat trace systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. MANDATORY REQUIREMENTS - (Continued) 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 ½ inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and Be installed at an orientation within 45 degrees of true south. 1. 2. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.7 Heating and cooling equipment. R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. When installed to function as a whole-house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. R403.6.1 Whole-house mechanical ventilation system fan efficacy. E x c e p t i o n : R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole-house mechanical ventilation, the air handler shall be powered by an electronically commutated motor. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. 1. 2. 3. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY For SI: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916 HRV or ERV In-line fan Bathroom, utility room Bathroom, utility room FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY AIRFLOW RATE MAXIMUM (CFM) (CFM/WATT) a Any Any 10 90 1.2 cfm/watt 2.8 cfm/watt 1.4 cfm/watt 2.8 cfm/watt Any Any <90 Any (CFM) Range hoods Any 2.8 cfm/watt Any MANDATORY REQUIREMENTS - (Continued) R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: Where public health standards require 24-hour pump operation. R403.10.2 Time switches. Pumps that operate solar- and waste-heat-recovery pool heating systems. Where pumps are powered exclusively from on-site renewable generation.3. 2. 1. 2/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Florida Building Code, Energy Conservation—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice-melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section R403.7, or the closest available size provided by the manufacturer’s product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. 2. Attached single- and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. When signed and sealed by a Florida-registered engineer, in attached single- and multiple-family units, the capacity of equipment may be sized in accordance with good design practice. The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing. Manufacturer’s expanded performance data shall be used to select cooling-only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water-source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. SECTION R404 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions-Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatory). The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. ELECTRICAL POWER AND LIGHTING SYSTEMS Page 5 of 52/2/2021 10:42 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software All gas- and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. R403.10.4 Gas- and oil-fired pool and spa heaters. Where more than 70 percent of the energy for heating, computed over an operation season, is from site-recovered energy, such as from a heat pump or solar energy source, covers or other vapor-retardant means shall not be required. Exception: Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. R403.10.3 Covers. R403.13 Dehumidifiers (Mandatory Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13, conform to the following requirements: R403.13.1 Ducted dehumidifiers. If installed, a dehumidifier shall conform to the following requirements: 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. 7106 Paso Robles Blvd, , FL, EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft²) New (From Plans) Detached 1 4 No 1449 7. Windows** a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Dbl, U=0.35 105.00 ft² SHGC=0.29 N/A f t ² N/A f t ² N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1449.00 ft² R= f t ² R= f t ² 10. Wall Type and Insulation a. Frame - Wood, Exterior R=13.0 1096.00 ft² b. Frame - Wood, Adjacent R=13.0 304.00 ft² c. N/A R= f t ² 11. Ceiling Type and insulation level a. Under Attic (Vented) R=30.0 1449.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts, location & insulation level 13. Cooling systems 14. Heating systems k B t u / h r 15. Hot water systems a. Electric Cap: 50 gallons EF: 0.92 b. Conservation features None d. N/A R= f t ² Description Area Insulation Area Insulation Area Insulation Area Credits (Performance method) Pstat Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 1.857 ft. 0.290 a. Electric Heat Pump 22.2 HSPF:8.20 a. Central Unit 22.2 SEER:14.50 k B t u / h r Efficiency Efficiency a. Sup: Attic, Ret: Main, AH: Main 6 289.8 R f t ² 8. Skylights a. U-Factor(AVG): S H G C ( A V G ) : Description Area N/A N/A f t ² I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:Date: Address of New Home:City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. Page 1 of 1 FORM R405-2020 2/2/2021 10:42 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: 66100 Port St. Lucie Wade Jurney Homes7106 Paso Robles Blvd - 1449 B LHG - S Street: City, State, Zip: , FL , 7106 Paso Robles Blvd Permit Number: Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls shall be sealed. Knee walls shall be sealed. The space between window/door jambs and framing, and skylights and framing shall be sealed. Rim joists shall include the air barrier. The air barrier shall be installed at any exposed edge of insulation. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Shafts, penetrations Crawl space walls Floors (including above-garage and cantilevered floors) Rim joists Windows, skylights Walls Ceiling/attic General COMPONENT Garage separation Recessed lighting Plumbing and wiring S h o w e r / t u b HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or The air barrier shall be installed behind electrical or communication boxes or air-sealed boxes shall be installed. The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs. Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Recessed light fixtures installed in the building thermal envelope shall be sealed to the finished surface. Air sealing shall be provided between the garage and conditioned spaces. When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. C o n c e a l e d Electrical/phone box on exterior walls Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA INSULATION INSTALLATION CRITERIA EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software2/2/2021 10:42 AM Page 1 of 1 Air-permeable insulation shall not be used as a sealing material. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Rim joists shall be insulated. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. and doors on exterior wall requirements Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. sprinklers Where provided instead of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exterior walls adjacent to showers and tubs shall be insulated. 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. a Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 1 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1...Job:Project Summary 07/23/20Date:House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 Project Information Wade Jurney HomesFor: Notes: Design Information Vero Beach Municipal AP, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F43 Outside db °F91 Inside db °F68 Inside db °F74 Design TD °F25 Design TD °F17 Daily range M Relative humidity %50 Moisture difference gr/lb62 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh10998 Structure Btuh12411 Ducts Btuh1298 Ducts Btuh2716 Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none)(none) Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh12296 Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load Btuh14522 Method Latent Cooling Equipment Load SizingSimplified Construction quality Semi-tight 0Fireplaces Structure Btuh3678 Ducts Btuh746 Central vent (0 cfm) Btuh0 CoolingHeating (none) 14221422Area (ft²)Equipment latent load Btuh4424 1137811378Volume (ft³) Air changes/hour 0.160.31 Equipment Total Load (Sen+Lat)Btuh18946 Equiv. AVF (cfm) 3059 Req. total capacity at 0.75 SHR ton1.6 Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB02400G0A0 Cond CH14NB02400G0A0 AHRI ref 9162301 Coil FB4CNP025L AHRI ref 9162301 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14.5 SEER Heating input Sensible cooling Btuh16650 Heating output Btuh @ 47°F22200 Latent cooling Btuh5550 Temperature rise °F0 Total cooling Btuh22200 Actual air flow cfm0 Actual air flow cfm740 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0.049 Static pressure in H2O0 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.77 Capacity balance point = 29 °F Backup: Input = 13 kW, Output = 43093 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 1 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1449...Job:Right-J® Worksheet 07/23/20Date:House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 1 Room name House KIT 2 Exposed wall 137.0 ft 12.0 ft 3 Room height 8.0 dft 8.0 heat/coolft 4 Room dimensions ft12.0x16.5 5 Room area 1422.3 ft²198.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.272.27 2.142.14 404 389 885 832 96 96 218 205 .GG 4A5-2ov4A5-2ov 0.3200.320 nn 8.008.00 8.738.73 15 0 120 131 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.272.27 2.142.14 132 82 186 175 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 ee 8.008.00 16.2616.26 30 14 240 488 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 9.759.75 6.946.94 20 20 196 140 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ss 2.272.27 2.142.14 264 249 566 532 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3200.320 ss 8.008.00 8.858.85 15 13 120 133 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ww 2.272.27 2.142.14 296 233 530 499 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3200.320 ww 8.008.00 22.7722.77 45 0 360 1025 0 0 0 0 DD 11D011D0 0.3900.390 ww 9.759.75 11.1111.11 18 18 174 199 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.272.27 1.241.24 304 286 651 354 0 0 0 0 DD 11D011D0 0.3900.390 nn 9.759.75 6.946.94 18 18 174 124 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.800.80 1.661.66 1422 1422 1138 2367 198 198 158 329 FF 22A-cpm22A-cpm 1.1801.180 --29.5029.50 0.000.00 1422 137 4041 0 198 12 354 0 6 c) AED excursion 297 -41 Envelope loss/gain 9383 7294 731 493 12 a) Infiltration 1615 567 141 50 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 5 1150 0 0 Appliances/other 3400 1200 Subtotal (lines 6 to 13)10998 12411 872 1743 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 123 219 14 Subtotal 10998 12411 995 1962 15 Duct loads 12%22%1298 2716 12%22%118 429 Total room load 12296 15127 1113 2391 Air required (cfm)Air required (cfm)0 740 0 117 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 2 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1449...Job:Right-J® Worksheet 07/23/20Date:House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 1 Room name BED 4 MBED 2 Exposed wall 29.5 ft 27.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft145.5x1.0 ft12.5x14.5 5 Room area 145.5 ft²181.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.272.27 2.142.14 112 112 255 240 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 nn 8.008.00 8.738.73 0 0 0 0 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.272.27 2.142.14 96 66 150 141 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 ee 8.008.00 16.2616.26 30 14 240 488 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 9.759.75 6.946.94 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ss 2.272.27 2.142.14 28 28 64 60 100 100 227 214 GG 4A5-2ov4A5-2ov 0.3200.320 ss 8.008.00 8.858.85 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ww 2.272.27 2.142.14 0 0 0 0 116 101 230 216 GG 4A5-2ov4A5-2ov 0.3200.320 ww 8.008.00 22.7722.77 0 0 0 0 15 0 120 342 DD 11D011D0 0.3900.390 ww 9.759.75 11.1111.11 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.272.27 1.241.24 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nn 9.759.75 6.946.94 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.800.80 1.661.66 146 146 116 242 181 181 145 302 FF 22A-cpm22A-cpm 1.1801.180 --29.5029.50 0.000.00 146 30 870 0 181 27 796 0 6 c) AED excursion -35 150 Envelope loss/gain 1695 1135 1519 1223 12 a) Infiltration 348 122 318 112 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)2043 1487 1837 1795 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 309 338 0 0 14 Subtotal 2352 1825 1837 1795 15 Duct loads 12%22%278 399 12%22%217 393 Total room load 2630 2224 2054 2188 Air required (cfm)Air required (cfm)0 109 0 107 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 3 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1449...Job:Right-J® Worksheet 07/23/20Date:House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 1 Room name ''MBA 2 Exposed wall 0 ft 6.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft3.5x3.5 ft6.0x14.5 5 Room area 12.3 ft²87.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.272.27 2.142.14 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 nn 8.008.00 8.738.73 0 0 0 0 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.272.27 2.142.14 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 ee 8.008.00 16.2616.26 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 9.759.75 6.946.94 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ss 2.272.27 2.142.14 0 0 0 0 48 48 109 103 GG 4A5-2ov4A5-2ov 0.3200.320 ss 8.008.00 8.858.85 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ww 2.272.27 2.142.14 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3200.320 ww 8.008.00 22.7722.77 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 9.759.75 11.1111.11 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.272.27 1.241.24 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nn 9.759.75 6.946.94 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.800.80 1.661.66 12 12 10 20 87 87 70 145 FF 22A-cpm22A-cpm 1.1801.180 --29.5029.50 0.000.00 12 0 0 0 87 6 177 0 6 c) AED excursion 0 -6 Envelope loss/gain 10 20 356 241 12 a) Infiltration 0 0 71 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)10 20 427 266 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -10 -20 2 86 14 Subtotal 0 0 429 352 15 Duct loads 12%22%0 0 12%22%51 77 Total room load 0 0 480 429 Air required (cfm)Air required (cfm)0 0 0 21 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 4 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1449...Job:Right-J® Worksheet 07/23/20Date:House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 1 Room name MWIC LAUN 2 Exposed wall 4.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft9.0x4.5 ft3.0x6.0 5 Room area 40.5 ft²18.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.272.27 2.142.14 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 nn 8.008.00 8.738.73 0 0 0 0 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.272.27 2.142.14 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 ee 8.008.00 16.2616.26 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 9.759.75 6.946.94 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ss 2.272.27 2.142.14 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3200.320 ss 8.008.00 8.858.85 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ww 2.272.27 2.142.14 36 36 82 77 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3200.320 ww 8.008.00 22.7722.77 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 9.759.75 11.1111.11 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.272.27 1.241.24 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 nn 9.759.75 6.946.94 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.800.80 1.661.66 41 41 32 67 18 18 14 30 FF 22A-cpm22A-cpm 1.1801.180 --29.5029.50 0.000.00 41 5 133 0 18 0 0 0 6 c) AED excursion -4 -12 Envelope loss/gain 247 141 14 18 12 a) Infiltration 53 19 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)300 159 14 518 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -14 -518 14 Subtotal 300 159 0 0 15 Duct loads 12%22%35 35 12%22%0 0 Total room load 336 194 0 0 Air required (cfm)Air required (cfm)0 9 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 5 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1449...Job:Right-J® Worksheet 07/23/20Date:House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 1 Room name BA 2 BED 2 2 Exposed wall 0 ft 11.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft9.0x6.0 ft135.0x1.0 5 Room area 54.0 ft²135.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.272.27 2.142.14 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 nn 8.008.00 8.738.73 0 0 0 0 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.272.27 2.142.14 0 0 0 0 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 ee 8.008.00 16.2616.26 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 9.759.75 6.946.94 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ss 2.272.27 2.142.14 0 0 0 0 88 73 166 156 GG 4A5-2ov4A5-2ov 0.3200.320 ss 8.008.00 8.858.85 0 0 0 0 15 13 120 133 WW 12C-0sw12C-0sw 0.0910.091 ww 2.272.27 2.142.14 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3200.320 ww 8.008.00 22.7722.77 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 9.759.75 11.1111.11 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.272.27 1.241.24 0 0 0 0 88 88 200 109 DD 11D011D0 0.3900.390 nn 9.759.75 6.946.94 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.800.80 1.661.66 54 54 43 90 135 135 108 225 FF 22A-cpm22A-cpm 1.1801.180 --29.5029.50 0.000.00 54 0 0 0 135 11 324 0 6 c) AED excursion -2 -8 Envelope loss/gain 43 88 919 615 12 a) Infiltration 0 0 130 46 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)43 88 1048 890 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 169 356 101 116 14 Subtotal 212 443 1149 1006 15 Duct loads 12%22%25 97 12%22%136 220 Total room load 237 540 1285 1227 Air required (cfm)Air required (cfm)0 26 0 60 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 6 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1449...Job:Right-J® Worksheet 07/23/20Date:House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 1 Room name BED 3 FOY 2 Exposed wall 10.5 ft 4.5 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft136.5x1.0 ft139.8x1.0 5 Room area 136.5 ft²139.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.272.27 2.142.14 84 69 157 148 0 0 0 0 .GG 4A5-2ov4A5-2ov 0.3200.320 nn 8.008.00 8.738.73 15 0 120 131 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.272.27 2.142.14 0 0 0 0 36 16 36 34 .GG 4A5-2ov4A5-2ov 0.3200.320 ee 8.008.00 16.2616.26 0 0 0 0 0 0 0 0 11 DD 11D011D0 0.3900.390 ee 9.759.75 6.946.94 0 0 0 0 20 20 196 140 WW 12C-0sw12C-0sw 0.0910.091 ss 2.272.27 2.142.14 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3200.320 ss 8.008.00 8.858.85 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ww 2.272.27 2.142.14 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.3200.320 ww 8.008.00 22.7722.77 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 9.759.75 11.1111.11 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.272.27 1.241.24 0 0 0 0 216 198 451 245 DD 11D011D0 0.3900.390 nn 9.759.75 6.946.94 0 0 0 0 18 18 174 124 CC 16B-30ad16B-30ad 0.0320.032 --0.800.80 1.661.66 137 137 109 227 140 140 112 233 FF 22A-cpm22A-cpm 1.1801.180 --29.5029.50 0.000.00 137 11 310 0 140 5 133 0 6 c) AED excursion -25 -30 Envelope loss/gain 696 481 1102 745 12 a) Infiltration 124 43 53 19 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 0 0 Appliances/other 300 500 Subtotal (lines 6 to 13)820 1054 1155 1264 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 470 514 -1155 -1264 14 Subtotal 1290 1568 0 0 15 Duct loads 12%22%152 343 12%22%0 0 Total room load 1442 1912 0 0 Air required (cfm)Air required (cfm)0 94 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 7 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1449...Job:Right-J® Worksheet 07/23/20Date:House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 1 Room name LIV 2 Exposed wall 32.0 ft 3 Room height 8.0 heat/coolft 4 Room dimensions ft274.5x1.0 5 Room area 274.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-0sw 0.091 n 2.27 2.14 112 112 255 240 .G 4A5-2ov 0.320 n 8.00 8.73 0 0 0 0 .W 12C-0sw 0.091 e 2.27 2.14 0 0 0 0 .G 4A5-2ov 0.320 e 8.00 16.26 0 0 0 0 11 D 11D0 0.390 e 9.75 6.94 0 0 0 0 W 12C-0sw 0.091 s 2.27 2.14 0 0 0 0 G 4A5-2ov 0.320 s 8.00 8.85 0 0 0 0 W 12C-0sw 0.091 w 2.27 2.14 144 96 219 206 G 4A5-2ov 0.320 w 8.00 22.77 30 0 240 683 D 11D0 0.390 w 9.75 11.11 18 18 174 199 P 12C-0sw 0.091 -2.27 1.24 0 0 0 0 D 11D0 0.390 n 9.75 6.94 0 0 0 0 C 16B-30ad 0.032 -0.80 1.66 275 275 220 457 F 22A-cpm 1.180 -29.50 0.00 275 32 944 0 6 c) AED excursion 311 Envelope loss/gain 2051 2095 12 a) Infiltration 377 132 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 900 Subtotal (lines 6 to 13)2428 3127 Less external load 0 0 Less transfer 0 0 Redistribution 5 173 14 Subtotal 2433 3300 15 Duct loads 12%22%287 722 Total room load 2721 4022 Air required (cfm)0 197 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 1 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1...Job:Static Pressure and Friction Rate 07/23/20Date: House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 Project Information Wade Jurney HomesFor: Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.500External static pressure Pressure losses 00Coil 00Heat exchanger 0.030.03Supply diffusers 0.030.03Return grilles 0.100.10Filter 00Humidifier 00Balancing damper 00Other device 0.34-0.2Available static pressure Total Effective Length ReturnSupply (ft)(ft) 018Measured length of run-out 08Measured length of trunk 0105Equivalent length of fittings 0131Total length 131Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) > 0.180.260< 0.06-0.122Supply Ducts > 0.180.260< 0.06-0.122Return Ducts Fitting Equivalent Length Details 11A=20, 4X=35, 11G=5, 11G=5, 1A=35, 11G=5: TotalEL=105Supply TotalEL=0Return 2021-Jan-20 14:23:07 Right-Suite® Universal 2019 19.0.20 RSU27934 Page 1 ...TEMP\7106 Paso Robles Blvd - 1449 B LHG - S.rut Calc = MJ8 Front Door faces: S 7106 Paso Robles Blvd - 1...Job:Duct System Summary 07/23/20Date: House WWBy: One Stop Cooling and Heating 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 Project Information Wade Jurney HomesFor: CoolingHeating External static pressure in H2O0.50in H2O0 Pressure losses in H2O0.16in H2O0.16 Available static pressure in H2O0.34in H2O-0.2 Supply / return available pressure -0.080 / -0.080 in H2O in H2O0.170 / 0.170 Lowest friction rate in/100ft0.260in/100ft-0.12 Actual air flow cfm740cfm0 Total effective length (TEL)ft131 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st295.010.8VlFx0x04.00.321260540cBA 2 st195.024.7VlFx0x06.00.2846001227cBED 2 st2100.015.7VlFx0x06.00.2949401912cBED 3 st2105.026.0VlFx0x06.00.26010902224cBED 4 st295.015.0VlFx0x06.00.30911702391cKIT st195.027.5VlFx0x07.00.27719704022cLIV st195.016.1VlFx0x04.00.306210429cMBA st195.017.1VlFx0x06.00.30310702188cMBED st195.017.7VlFx0x04.00.30290194cMWIC Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 0 394 0.277 502 12.0 0x0 VinlFlx st2 Peak AVF 0 346 0.260 634 10.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 00 740 0 0 0 0 x0 0 VlFx Job #: 7106 Paso Robles Blvd-1449 B LHG-S Performed by WW for: Wade Jurney Homes One Stop Cooling and Heating 7225 Sandscove Court Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 www.OneStopCooling.com Scale: 1 : 73 Page 1 Right-Suite® Universal 2019 19.0.19 RSU27934 Level 1 KIT GAR BED 4 MBED '' MBA MWIC LIV LAUN BA 2 BED 2 BED 3 FOY SRB 1 DV RV SRB 2 10x6 24x14 RA 10x6 8x4 8x4 10x8 10x6 8x4 10x6 T 10x6 2.0 ton W/5KW @240V 1PH 14X14 Plen ON METAL STAND A/C-1: 2.0 TON 14.0 SEER H.P. AC Slab By Builder 2' From Wall 4" Bath Duct to Roof W/Fan Broan 50CFM 4" Bath Duct to Roof W/Fan Broan 50CFM 27 cfm 110 cfm 116 cfm 24 x 4 10 cfm 195 cfm 24 x 4 107 cfm 24 x 4 24 x 4 21 cfm 740 cfm 60 cfm 95 cfm 4 " 6 " 6 " 4 " 7 " 6 " 4 " 12 " 10 " 6 " 6 " 4" Dryer Duct to Roof Cap w/Dryer Vent Box