HomeMy WebLinkAboutEngery CalcsFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 6805 Citrus Park Blvd 1650 B RHG- N
Builder Name: WADE JURNEY HOMES
Street: 6805 Citrus Park Blvd
Permit Office: St. Lucie
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1456.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame - Block, Exterior
R=4.1 1164.00 ft2
b. Frame - Wood, Adjacent
R=13.0 292.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1650.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1650.00 ft 2
6. Conditioned floor area above grade (ft2) 1650
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11 Ducts
R ft2
7. Windows(126.0 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 330
a. U-Factor: Dbl, U=0.35 126.00 ft2
SHGC: SHGC=0.29
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
22.2 SEER:14.50
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d U-Factor: N/A ft2
a. Electric Heat Pump
22.2 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.290
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1650 0 sqft.) Insulation Area
EF: 0.920
a Slab -On -Grade Edge Insulation R=0.0 1650.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.076 Total Proposed Modified Loads: 47.77
PASS
Total Baseline Loads: 48.32
1 hereby certify that the plans and specifications covered by
Review of the plans and
1-KYiE Sr�r
this calculation are in compliance with the Florida Energy
specifications covered by this
0_
Code.
calculation indicates compliance-
with the Florida Energy Code
' ':�„ ❑
/
PREPARED BY: Z;'2V-t�
Before construction is completed
DATE: 09/23/20
this building will be inspected for
a
compliance with Section 553.908
I hereby certify that this bui ' g, designed, is in compliance
Florida Statutes.
r
with the Florida Energy de.
�Da WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
9/23/2020 2:33 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
6805 Citrus Park Blvd 1650 B
Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 1650
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision: LWP
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
WADE JURNEY HOMES
Rotate Angle: 180
Street: 6805 Citrus Park Blvd
Permit Office:
St. Lucie
Cross Ventilation: No
County: St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip: Fort Pierce ,
Family Type:
Single-family
FL , 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating Design Daily Temp
V Design Location TMY Site
97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO BEACH AIRPORT 45 90
70
75 369 69 Medium
BLOCKS
Number
Name Area
Volume
1
Block1 1650
13200
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main 1650
13200 Yes 5
4
1 Yes Yes Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 145.5 ft 0
1650 ft2
---- 0.29 0 0.71
ROOF
Roof Gable Roof
Rad
Solar SA Emitt Emitt Deck Pitch
V #
Type Materials
Area Area Color
Barr
Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1739 ft' 274 ftz Dark
N
0.5 N 0.5 No 0 18.4
ATTIC
/
V
#
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Vented 300 1650 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1650 ft' 01 Wood
9/23/2020 2:33 PM EnergyGaugeO USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
• : u : - lIllltC-111►TJIJJF\:YKA:I44111]: O1.119 »:1rla11
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar Below
aY QrnL _ To Wall Type_ Space R-V;;his FL __la_ -.Et In Area
R4alue Fracliort__Absoc__GradeJ
1 S=>N Exterior Block - Wood Main
4.1 18 0 8
0 144.0 ft'
0
0.25 0.4
0
2 E=>W Exterior Block -Wood Main
4.1 36 6 8
0 292.0 ft'
0
025 0.4
0
3 N=>S Exterior Block -Wood Main
4.1 38 6 8
0 308.0 ft'
0
0.25 0.4
0
4 W=>E Exterior Block -Wood Main
4.1 52 6 8
0 420.0 ft'
0
0.25 04
0
5 -SE Garage Frame - Wood Main
13 36 6 8
0 292.0 ft'
0
0.25 0.4
0
DOORS
V # Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 S=>N Insulated Main
None
.4 3
3 8
20 ft'
2 N=>S Wood Main
None
.46 2
8
u
17.8 ftZ
3 -SE Wood Main
None
.46 2
8
6 8
17.8 ft'
WINDOWS
Orientation shown is the entered orientation => changed to As Built (rotated 180 degrees).
/ Wall
Overhang
v # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1 S=>N 1 Vinyl Low-E Double Yes
0.35 0.29 N
30.0 ft' 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
2 E=>W 2 Vinyl Low-E Double Yes
0.35 0.29 N
30 0 ft' 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
3 N=>S 3 Vinyl Low-E Double Yes
0.35 0.29 N
6 0 ft' 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
4 N=>S 3 Vinyl Low-E Double Yes
0.35 0.29 N
30.0 ft' 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
5 W=>E 4 Vinyl Low-E Double Yes
0.35 0.29 N
30.0 ftZ 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 403 ft' 403 ft'
46 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1540 84.54 159 .1339
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.2
22.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit/ Split
Singl SEER: 14.5 22.2 kBtu/hr 666 cfm
0.75 1
sys#1
9/23/2020 2:33 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.92 50 gal
70 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cent #
Company Name
System Model # Collector
Model
# Area
Volume
FEF
None
None
ftz
DUCTS
---- Supply ----
--- Return ----
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value
Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 330 ftZ
Main
82.5 ftZ Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin ]Jan
Feb
Mar
[
] A r
May X Jun Jul
Au
X Se
f
Oct
Nov
Dec
Heating X] Jan
X Feb
Xj Mar
[
] APr f
May 4 Jun Jul
rj
AuSep
�Xj
Oct
Nov
H
Dec
Ventin [ ] Jan
[ Feb
X Mar
[X]
A r [
Ma [ Jun Jul
Aug
Se
[X
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
9/23/2020 2:33 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 6805 Citrus Park Blvd Permit Number:
Fort Pierce , FL , 34951
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL) display
card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section
553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold
residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a
dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and
specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402 4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal enveldilie building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with
the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the
code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air Where using
tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air IeakagdNndows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
9/23/2020 2:33 PM EnergyGauge® USA 6 0 02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R402.4.4 Rooms containing fuel -burning appliances. In Climate "Zones 3 through 8, where open combustion air ducts provide combustion ai+ to open
combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a
room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table
R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully
gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1 Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between
conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than
2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be
sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3 3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of
the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manuf,
air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2 Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or
below 55°F (1 YC) shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused
by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the
material. Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe
❑ shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
9/23/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps (Mandatory). Storage: water heaters not equipped with integral heat traps and having vertical prpe ris+:fs shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/z inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting
range shall be from 100°F to 140°F (38°C to 60°C).
❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
❑ R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table
C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403 6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor
units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in
Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect
equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as
standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating
equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916
9/23/2020 2:33 PM EnergyGauge® USA 6 0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is riot less than
;he calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section
403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall
not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
2.
Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements
calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403
and C404 of the IECC—Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
El
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall
be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of
such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
9/23/2020 2:33 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with
AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to
verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
❑ R403.11 Portable spas (Mandatory$e energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high, -,efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights.
9/23/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition 1 New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
60
2 Single-family or multiple -family 2. 5inale-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family) 3. 1
4 Number of bedrooms 4. 4
13 Cooling system: Capacity
22.2
a) Split system SEER
14.5
5. Is this a worst case? (yes/no) 5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 1650
d) Room unit/PTAC EER
e) Other
7 Windows, type and area
a) U-factor:(weighted average) 7a 0.350
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.290
14. Heating system: Capacity
22.2
c) Area 7c. 1260
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value) 9a. 00
b) Wood, raised (R-value) 9b.
15. Water heating system
c) Concrete, raised (R-value) 9c.
a) Electric resistance EF
0.92
b) Gas fired, natural gas EF
10 Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value) 10A1._ 13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value) 10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value) 10131. 13.0
2. Masonry (Insulation R-value) 10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic 11 a. 30.0
b) Cross ventilation
No
b) Single assembly 11 b.
c) Whole house fan
No
c) Knee walls/skylight walls 11 c
d) Multizone cooling credit
d) Radiant barrier installed 11d No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy
Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be complete d on installed code compliant features.
Builder Signature:
Date
Address of New Home: 6805 Citrus Park Blvd
City/FL Zip. Fort Pierce. FL 34951
9/23/2020 2:33:17 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: 6805 Citrus Park Blvd 1650 B RHG- N Builder Name: WADE JURNEY HOMES
Street: 6805 Citrus Park Blvd Permit Office: St. Lucie
City, State, Zip: Fort Pierce , FL, 34951 Permit Number:
Owner: Jurisdiction: 661000
w
Design Location FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in an dropped9
ceiling/soffit
/soffit
insulation and any gaps in the air barrier shall be sealed
shall be aligned with the air barrier
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed
inch minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces
Garage separation
Air sealing shall be provided between the garage and conditioned spac
.s
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
betWegEl fire si)rinkler cover plates and walls r ilia
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
9/23/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Project Summary Job: 6805 Citrus Park Blvd 165...
- + wrightsoft9 , ry Date: 07/24/2020
House W. LVL
One Stop Cooling and Heating Plan: 1650 B LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: www.OneStopCooling com License: CAC1817652
For: WADE JURNEY
6805 Citrus Park Blvd, Fort Pierce, FL 34951
Notes:
Weather: FL, Fort Pierce
Winter Design Conditions
Outside db 43 °F
Inside db 68 °F
Design TD 25 °F
Heating Summary
Structure
13431
Btuh
Ducts
1382
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
14813
Btuh
Method
Construction quality
Fireplaces
Area (M
Volume (ft)
Air changes/hour
Equiv.AVF (cfm)
Infiltration
Simplified
Average
0
He1t64g
COMB
13130
13130
0.38
0.20
83
44
Heating Equipment Summary
Make Carrier
Trade CARRIER
Model CH14NBO2400GOA0
AHRI ref 9162301
Summer Design Conditions
Outside db
91
°F
Inside db
74
°F
Design TD
17
°F
Daily range
L
Relative humidity
50
%
Moisture difference
65
grAb
Sensible Cooling Equipment Load
Sizing
Structure
12819
Btuh
Ducts
2875
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturers data n
Rate/swing multiplier 0.96
Equipment sensible load 15035 Btuh
Latent Cooling Equipment Load Sizing
Structure
3581
Btuh
Ducts
771
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
4352
Btuh
Equipment Total Load (Sen+Lat) 19387 Btuh
Req. total rapacity at 0,75 SHR 1.7 ton
Cooling Equipment Summary
Make
Carrier
Trade
CARRIER
Cond
CH14NBO2400GOA0
Coil
FB4CNP025L
AHRI ref
9162301
Efficiency
8.2 HSPF
Efficiency 11.5 EER,14.5 SEER
Heating input
Sensible cooling
16650
Btuh
Heating autput
22200 Btuh @ 47°F
Latent cooling
5550
Btuh
Temperature rise
0 °F
Total cooling
22200
Btuh
Actual airflow
0 cfm
Actual airflow
740
cfin
Air flow factor
0 cfrnBtuh
Air flow factor
0.047
cfm/Btuh
Static pressure
0 in H2O
Static pressure
0.50
in H2O
rmostetpoint
Load sensible heat ratio
0.78
Capce th = 34 °F
Backup:
Input =13 kW, Output = 43093 Btuh,100 AFUE
Calculations
approved byACCA to meet all requirements of Manual J 8th Ed.
-FP- wrigti n 2020-Sep-2314:28:15
Right -Suite® Universal201919020 RSU25029 Page 1
/tCCp.... k Blvd 6805 Citrus Park Blvd 1650 B RHG- N rut Calc= MJB Front Door faces: N
wrightsoft Right-J® Worksheet
House
One Stop Cooling and Heating
Job: 6805 Citrus Park Blvd 1650 B ...
Date: 07/24/2020
LVL
Pan: 1650 B LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwwvOneStopCooling corn License: CAC1817652
1
Room name
House
KIT
2
E)posed wall
145 5 ft
12.0 ft
3
Room height
8.0 ft d
8.0 ft heat/000l
4
Room dimensions
12.0 x 125 ft
5
Room area
1641.3 ft2
150.0 fF
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
Area (W)
Load
number
(Btuh/ft-°F)
(BWhAt=)
or perimeter (it)
(Btuh)
or perimeter (ft)
(BWh)
Heat
Cod
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A flocs
0143
ne
352
2.80
308
253
889
708
96
90
317
252
4A5-20v
0320
ne
7,87
17.44
6
0
47
105
6
0
47
105
4A5-20v
0 320
ne
787
17.44
30
0'
236
523
0
0
0
0
11DO
0390
ne
9.59
12o1
19
19
185
231
0
0
0
0
W
11
13A-4ocs
0.143
se
3.52
2.80
292
262
922
734
0
0
0
0
4A-12ov
0 320
se
7.87
1723
30
2
236
517
0
0
0
0
W
13A-4ocs
4A5-2ov
0143
0 320
sw
sw
3.52
787
2.80
1723
144
30
94
2
329
236
262
517
0
0
0
0
0
0
0
0
D
11 DO
0.390
sw
959
784
20
20
196
160
0
0
0
0
IW
13A-4ocs
0.143
nw
3.52
2.80
420
390
1372
1093
0
0
0
0.
G
4A5-2ov
0 320
nw
7.87
17.44
30
0
236
523
0
0
0
0
T—D
12C-0sw
0.091
-
224
1 A5
292
274
614
397
0
0
0
0
11 DO
0 390
n
9.59
7.84
18
18
169
138
0
0
0
0
C
16B-30ad
0032
0.79
1.74
1641
1641
1292
2852
150
150
118
261
F
22A-4pm
1180
29.03
0.00
1641
146
4224
0
150
12
348
0
6
c)AED excursion
0
-110
Envelopelossrgain
11183
8761
830
508
12
a) Infiltration
2248
808
185
67
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
5
1150
0
0
Applianoes/other
2100
1200
Subtotal (lines 6 to 13)
13431
12819
1016
1774
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
13431
12819
1016
1774
15
Dudloads I
10%
22%
1382
2875
109/a 1
221/a
105
3138
Total room load
14813
15694
1120
2172
Airrequired (dm)
0
740
0
102
Calculations aDDroved NACCA to meet all reauirements of Manual J 8th Ed
_ wrigF�tsoit 2020-Sep-2314:28:15
ACCA ._...__.....,_. Right-Suite.anUniversal 201919.0IC-RSU25029 Page
-.rk Blvd'6805 Citrus Paris Blvd 1650 B RHG-N rut Calc= MJ8 Frocr Door faces: N
wrightsoft• Right-l® Worksheet
House
One Stop Cooling and Heating
Job: 6805 Citrus Park Blvd 1650 B ...
Date: 07/24/2020
LVL
Pan: 1650 B LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwvw0neStopCooling com License: CAC1817652
1
Room name
LAUN
FOY
2
Eposed wall
O ft
3-5 ft
31
Room height
80 ft heat/000l
80 ft heaNcool
4
5
Room dimensions
Room area
70 x 40 ft
280 1?
1.0 x 211.0 ft
2110 ft'
Ty
Construction
U-value
Or
HTM
Area (@)
Load
Area (W)
Load
number
(BtuhAF °F)
(BtuhfiL�
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6Vh13AAocs
0.143
ne
3.52
2.80
0
0
0
0
0
0
0
0
4A5-2ov
4A5-2ov
0.320
0.320
ne
ne
7.87
7.87
17.44
17.44
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11 DO
0.390
ne
9.59
1201.
0
0
0
0
0
0
0
0
11
W
13AAocs
4A5-2ov
0143
0.320
se
se
352
7.87
2.80
1723
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
13AAocs
0.143
sv
3.52
2.80
0
0
0
0
28
6
27
21
4A5-2ov
0.320
sw
7.87
1723
0
0
0
0
0
0
0
0
11 DO
0.390
snr
9.59
7.84
0
0
0
0
20
20
196
160
IW
�--G
R
13"ocs
4A5-2ov
12C-096v
0143
0.320
0091
nw
nw
-
3.52
7.87
224
2-80
17.44
1.45
00
0
0
0
0
0
0
0
0
0
0
0
0
132
0
0
114
0
0
256
0
0
166
I L----D
I
11 DO
0 390
n
9.59
7.84
0
0
0
0
18
18
169
138
C
1613-30ad
0.032
0.79
1.74
28
28
22
49
211
211
166
367
F
22A-tpm
1.180
29.03
0.00
28
0
0
0
211
4
102
0
6
c)AED excursion
-35
-63
Envelopelosslgain
22
13
915
788
12
a) Infiltration
0
0
54
19
b) Room ventilation
0
0
0
0
13
Intemal gains Occupants @ 230
0
0
0
0
Appliances/other
500
1100
subtotal (lines 6to13)
22
513
969
908
Less exdemalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
-22
-513
-969
-908
14
Subtotal
0
0
0
0
151
Dudloads
10%
22%
0
0
10%
22%
0
0
Total room load
0
0
0
0
Air required (dm)
0
0
0
0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrrgl-�taoi`C-° 2020-Sep-2314:28:15
- — — • Right-SuiteC0 Universal 201919.020 RSU25029 Page 2
AccK .-.rk BIW'6805 Citrus Paris Blvd 1650 B RHG- N.rut Calc = MJ8 Front Docrfaces: N
wrightsoft• Right-J® Worksheet
House
One Stop Cooling and Heating
Job: 6805 Citrus Park Blvd 1650 B...
Date: 07/24/2020
LVL
Pan: 1650 B LHG
7225 Sandscove Court, Wnter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629- 9307 Web: www.OneStopCooling com License: CAC1817652
1
Room name
FLEX
2
Eposed wall
0 ft
10.5 it
3
Room height
8.0 ft heat/000l
80 ft heat/cool
4
Room dimensions
3.5 x 3.0 ft
14.0 x 105 ft
5
Room area
10.5 T
147 0 T
Ty
Construclion
U-value
Or
HTM
Area (ft�
Load
Area (W)
Load
number
(BtuhAF--'F)
(B
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cod
Gross
N/P/S
Heat
Cod
Gross
NrP/S
Heat
Cool
6
1qJ
0.320
ne
352
2.80
0
0
0
0
0
0
0
0
A5-2ovs
4Arr2ov
0.320
ne
7.87
1744
0
0
0
0
0
0
0
0
��L—((p`'
4A5-2ov
0.320
ne
787
17.44
0
0
0
0
0
0
0
0
11 DO
0.390
ne
9.59
12011
0
0
0
0
0
0
0
0
11
IW
L—G
13A-4ocs
4A-12ov
0143
0 320
se
se
352
787
2801
1723i
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W
13A4ocs
4A5-2ov
0.143
0.320
sw
sw
3.52
7.87
2.80
1723
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
D
11 DO
0.390
sw
959
7.84
0
0
0
0
0
0
0
0
IW
13A-4ocs
0.143
nw
352
280
0
0
0
0
84
69
243
193
L—G
4A-12ov
0 320
nw
787
17.44
0
0
0
0
15
0
118
262
12C-096v
0 091
-
224
145
28
28
63
41
0
0
0
0
11 DO
0 390
n
959
7.84
0
0
0
0
0
0
0
0
C
16B-30ad
0.032
079
1.74
11
11
8
18
147
147
116
255
l
F
22A-tpm
1.180
29.03
000
11
0
0
0
147
11
305
0
6
c)AED excursion
-4
55
Envelope loss/gain
71
55
781
766
12
a) Infiltration
0
0
162
58
b) Room ventilation
0
0
10
0
13
Intemal gains. Oo upants @ 230
0
0
0
0
Appliancesbitw
0
300
Subtotal (lines 6 to 13)
71
55
944
1124
Less exlemal load
0
0
0
0
Lesstransier
0
0
0
0
Redistribution
-71
-55
143
134
14
Subtotal
0
0
1087
1258
151
Dudloads
100/0
229% 1
0
0
10%
22°/n
112
282
Total room load
0
0
1199
1540
Air required (dm)
0
0
0
73
Calculations aooroved bvACCA to meet all reauirements of Manual J 8th Ed
~ wrigl �ts�fC 2020-Sep-23 14:28:15
••••- Right -Suite Universal2019 19.020 FSU25029 Page 3
...rk BI AIC805 Cirrus Park Blvd 1650 8 RHG- N.rut Calc= MJ8 Froni ['uor faces: N
wrightsoft- Right-J® Worksheet
House
One Stop Cooling and Heating
Job: 6805 Citrus Park Blvd 1650 B ...
Date: 07/24/2020
Bgyy� LVL
Pfan: 1650 B LHIG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC1817652
1
Room name
BED 3
BA2
2
Exposed wall
10.0 ft
5.5 ft
3
Room height
80 ft heat/cod
8.0 ft heatbool
4
Room dimensions
140 x 10.0 ft
100 x 55 ft
5
Room area
140.0 1F
55.0 it'
Ty
Construction
U-value
Or
HTM
Area (W)
Load
Area (1F)
Load
number
(BtuhAF--°F)
(BtrahAt�
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cod
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
Cool
6�13A-flocs
0.320
ne
3.87
2.80
0
0
0
0
0
0
0
0
4AS2ov
0.320
ne
7.87
17.44
0
0
0
0
0
0
0
0
4A5-2ov
0.320
ne
7.87
1744
0
0
0
0
0
0
0
0
11 DO
0.390
ne
9.59
12.01
0
0
0
0
0
0
0
0
IW
11
13A-4ocs
0.143
se
352
2.80
0
0
0
0
0
0
0
0
L—G
4A5-2ov
0.320
se
787
1723
0
0
0
0
0
0
0
0
W
13A-4ocs
0.143
sw
3.52
280
0
0
0
0
0
0
0
0
4AS2ov
0 320
sw
7.87
17.23
0
0
0
0
0
0
0
0
11 DO
0 390
sw
959
784
0
0
0
0
0
0
0
0
W
13A-4ocs
0.143
nw
3.52
2.80
80
65
229
182
44
44
155
123
4A5-2ov
0.320
nw
7.87
1744
15
0
118
262
0
0
0
0
L-.12C-0sw
D
0.091
-
224
1.45
0
0
0
0
0
0
0
0
11 DO
0 390
n
9.59
784
0
0
0
01
0
0
0
0
C
16B-30ad
0.032
0.79
174
140
140
110
243
55
55
43
96
F
22A-tpm
1.180
29.03
000
140
10
290
0
55
6
160
0
6
c)AED excursion
62
-16
Envelopeloss/gain
747
748
358
203
12
a) Infiltration
155
56
85
31
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
1
230
0
0
Applianoeslother
0
O
Subtotal (lines6 to 13)
902
1034
443
233
Less exdemalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
191
179
75
70
14
Subtotal
1093
1213
518
304
15
Ductloads
10%
22%
112
272
10%
22%
53
68
Total room load
1205
1485
571
372
Air required (dm)
0
70
0
18
Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed
—1-F wV ghtwcw t- 2020-Sep-2314:28:15
- Right-SuiteOUniversal 2019 19.0.20 RSU25029 Page 4
;_rk Blvd%6805 Citrus Park Blvd 1650 B RHG- N.rut Calc= MJ8 Front Door faces: N
wrightsoft• Right-J® Worksheet
House
One Stop Cooling and Heating
Job: 6805 Citrus Park Blvd 1650 B ...
Date: 07/24/2020
LVL
Pan: 1650 B LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling corn License: CAC1817652
1
Room name
BED 2
BED 1
2
Exposed wall
28 5ft
105 ft
3
Room height
80 It heat/cool
I 80 ft heaU000l
4
Room dimensions
10 x 162 3 ft
110 x 105 ft
5
Room area
162 3 T
1155 W
Ty
Construction
U-value
Or
HTM
Area (W)
Load
Area (ft?)
Load
number
(BtuhV-'F)
(BtuhM
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
Cool
6
s
0-320
3.87
2.44
0
0
0
0
0
0
0
0
4A5-2ov
A5-2o
0-320
ne
ne
7.67
17.44
0
0
0
0
0
0
0
0
4A5-2ov
0.320
ne
7.87
17.44
0
0
0
0
0
0
0
0
D
11 DO
0-390
ne
9.59
1201
0
0
0
0
0
0
0
0
W
W
11
13A- ocs
4A5-2ov
13AAors
0.143
0.320
0.143
se
se
sw
3.52
7.87
352
280
1723
280
20
0
116
20
0
86
70
0
303
56
0
241
84
15
0
69
1
0
243
118
0
193
258
0
0.320
sw
787
1723
30
2
236
517
0
0
0
0
EJD4A5-2ov
11 DO
0 390
s+v
959
784
0
0
0
0
0
0
0
0
IW
L—c
13A-0ocs
4A5-2ov
0143
0.320
nw
nw
352
787
280
17.44
92
0
92
0
324
0
258
0
0
0
0
0
0
0
0
0
q
I—D
12C-0sw
0 091
-
224
1.45
0
0
OI
0
88
88
197
127
11DO
0.390
n
9.59
7.84
0
0
0
0
0
0
0
0
C
16B-30ad
0 032
079
1.74
162
162
128
282
116
116
91
201
F
22A-tpm
1.180
29.03
ODD
162
29
827
0
116
11
305
0
6
c)AED excursion
127
54
Envelope loss(gain
1888
1480
954
834
12
a) Infiltration
440
158
162
58
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
1
230
1
230
Appliancesiother
10
10
Subtotal (lines 6 to 13)
2328
1869
1116
1123
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redishibuton
184
173
48
45
14
Subtotal
2512
2041
1164
1167
15
Ductloads
10%
22%
259
458
10%
220A
120
262
Total room load
2771
2499
1283
1429
Airrequired (dm)
0
118
0
67
Calculations approved WACCA to meet all requirements of Manual J 8th Ed
-4- wrPy! �ttso€t 2020-Sep-23 14:28:15
• ...... ••- -- RigNSuiteeUniversal 201919.0-20RSU25029 Pages
-.A BlvdZ805 Citrus Park Blvd 1650 B RHG- N.rut Calc = MJ8 Front Door faces: N
- wrightsoft• Right-J® Worksheet Job: 6805 Citrus Park Blvd 1650 B...
House Date: 0712412020
LVL
One Stop Cooling and Heating P an: 1650 B LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www0neStopCooling-com License: CAC1817652
1
Room name
MBED
MWIC
2
Exposed wall
11.0 ft
185 ft
3
Room height
8.0 ft heat/cool
80 ft heaV000l
4
5
Room dimensions
Room area
14.5 x 11.0 It
159.5 1F
6.0 x 12.5 It
75.0 f1
Ty
Construclion
U-value
Or
HTM
Area (W)
Load
Area (W)
Load
number
(BtuhffL'F)
(Btuh/r
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cod
Gross
N/P/S
Heat
Cod
Gross
NIPS
Heat
Cool
6
%1�13A-0ocs
0.143
ne
3.52
280
0
0
0
0
48
48
169
135
4A5-2ov
0 320
ne
1 7.87
17.44
0
0
0
0
0
0
0
0
4A5-2ov
0.320
ne
7.87
17.44
0
0
0
0
0
0
0
0
11 DO
0.390
ne
9.59
12.01
0
0
0
0
0
0
0
0
W
11
13A4ocs
4A5-2ov
0.143
0.320
se
se
3.52
7.87
2.80
1723
88
15
73
1
257
118
205
258
100
0
100
0
352
0
280
0
W
13A-4ocs
0.143
sw
3.52
2.80
0
0
0
0
0
0
0
0
4A5-2ov
0.320
sw
7.87
1723
0
0
0
0
0
0
0
0
11 DO
0 390
sw
9.59
7.84
0
0
0
0
0
0
0
O
IW
R�---G
i---D
13A4ocs
4A5-2ov
0143
0 320
nw
.
3.52
7.87
2.80
1744
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11DO
0.390
n
959
17.84
0
0
01
OI
0
0
0
0
C
1613-30ad
0.032
079
1.74
160
160
126
277
75
75
59
130
F
22 -tpm
1.180
29.03
0.00
160
11
319
0
75
19
537
0
6
c)AED excursion
42
-42
Envelope loss/gain
820
782
1117
W3
12
a) Infiltration
170
61
286
103
b) Room ventilation
0
0
0
0
13
Intemalgains Occupants@ 230
2
460
0
0
Applianaesbtw
0
0
Subtotal (lines 6to13)
990
1303
1403
606
Less external load
0
0
0
0
LesstransW
0
0
0
0
Redistributon
48
45
0
0
14
Subtotal
1037
13411
1403
606
15
Dudloads
10%
221/n
107
302
10%l
22°/a
144
136
Total room load
1144
1650
1
1547
742
Air required (dm)
0
78
0
35
Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _
-1-- wrights�Tt ^ 2020-Sep-23 14:28:15
^...-•- - - - Right -Suite® Universal 2019 19.0 20 RSU25029 Page 6
rk l3lA 805 Citrus Park Blvd 1650 B RHG- N rut Calc= MJB Front Door faces: N
wrightsoft• Right-J® Worksheet
House
One Stop Cooling and Heating
Job: 6805 Citrus Park Blvd 1650 B ...
Date: 07/24/2020
MLVL
1650 B LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: ww ..OneStopCooling com License: CPC1817652
1
Room name
MBA
WIC 1
2
Exposed wall
O ft
O ft
3
Room height
80 It heat/cool
8.0 it heat/cool
4
5
Room dimensions
Room area
55 x 110 ft
60 5 W
10 x 245 It
24 5 tF
Ty
Construction
U-value
Or
HTM
Area (ftF)
Load
Area (W)
Load
number
(BtuhAF--°F)
(B
or perimeter (ft)
(Btuh)
or perimeter (ft)
(BILh)
Heat
Cod
Gross
N/P/S
Heat
Cod
Gross
NAPS
Heat
Cod
6
13AAocs
0.143
ne
3.52
280
0
0
0
0
0
O
0
0
4A5-2ov
0.320
ne
7.87
17.44
0
0
0
0
0
0
0
0
4A5-2ov
0.320
ne,
7.87
17.44
0
0
0
0
0
0
0
0
11DO
0.390
ne
9.59
12.01
0
0
0
0
0
0
0
0
Iw
L—G
11
13A-4ocs
4A5-2ov
0143
0 320
se
se
352
787
280
1723
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
w
13AAocs
4A5-2ov
0.143
0.320
sw
sw
3.52
7.87
2.80
1723
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
D
11DO
0.390
sw
9.59
7.84
0
0
0
0
0
0
0
0
Iw
L—c
13AAocs
0143
nw
352
280
0
D
0
0
0
0
0
0
4A5-2ov
12C-Osw
0.320
0.091
nw
-
787
224
17.44
1.45
0
0
0
0
0
0
0
0
0
44
0
44
0
98
0
54
11DO
0.390
n
9.59
7.84
0
(3
0
0
0
0
0
0
C
1613-30ad
0.032
0.79
1.74
61
61
48
105
25
25
19
43
F
22Prtpm
1.180
29.03
0.00
61
0
0
0
25
0
0
0
6
c)AED excursion
-7
-7
Envelope losstgain
48
98
118
99
12
a) Irfillraton
0
0
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliancesldher
0
0
Subtotal (lines 6 to 13)
46
98
118
99
Less extemalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
191
179
120
594
14
Subtolal
239
277
238
693
15
Dudloads
10%
22°/a
25
62
10%
22°/a
25
155
Total room load
263
340
263
849
Airrequired (dm)
0
16
0
40
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
F wrigF�tsoft•° --••--•- • • - - Right-Suite®Universal 201919.0 20 RSU25029 2020-Sep-2314:28:15
..-rk BlvM6805 Citrus Park Blvd 1650 B RHG- N rut Calc = MJB Front Doorfaces: N Page l
wrightsoft` Right-JO Worksheet
House
One Stop Cooling and Heating
Job: 6805 Citrus Park Blvd 1650 B ...
Date: 07/24/2020
LVL
Pan: 1650 B LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652
1
Room name
LIV
2
Exposed wall
35.5 ft
3
Room height
8-0 ft heaVbool
4
Room dimensions
1.0 x 302.5 It
5
Room area
302.5 fF
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area
Load
number
(Btuh&-°F)
(Btj M
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cod
Gross
N/P/S
Heat
Cod
Gross
N/PS
Heat
Cool
6
Ih13A4ors
0.143
ne
3.52
2.80
164
115
404
322
4AS2ov
0 320
ne
787
17.44
0
0
0
0
4A5-2ov
0.320
ne
7.87
17.44
30
0
236
523
11 DO
0.390
ne
959
12.01
19
19
185
231
IW
L—c
11
13A-4ots
4A5-2ov
0143
0 320
se
se
352
787
2 80
1723
0
0
0
0
0
0
0
0
W
13A-4ors
0.143
sw
3.52
2.80
0
0
0
0
4A5-2ov
11DO
0.320
0.390
sw
sw
787
9.59
17.23
7.84
0
0
0
0
0
0
0
0
W
L—G
cs 13A-4o
4A5-2ov
01431
0320
nw
nw
3.52
7.87
2.80
1744
120
0
120
0
422
0
336
0
12C-09w
0 091
I
-
2.24
1.45
0
0
0
0
11 DO
0.390
n
9.59
784
0
0
0
0
C
1613-30ad
0 032
079
174
303
303
238
526
F
22A-tpm
1180
29.03
0.00
303
36
1030
0
6
c)AED excursion
-56
Envelope loss(gain
2515
1882
12
a) Infiltration
549
197
b) Room ventilation
0
0
13
Internal gains: Occupants@ 230
0
0
Applianoesktw
0
Subtdal(lines 6to13)
3064
2079
Lem exiemalload
0
0
Lesstransfer
0
0
Redistribution
61
58
14
Subtotal
3125
2137
151
Dudloads
10%
22%
322
479
Total room load
3447
2616
Air required (cim)
0
123
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
�i- wrig F�tsofti ° 2020-Sep-2314:28:15
P'gtit•Suil' Universal 2019 19.020 RSUZ5029 Page 8
...rk RI WV05 Citrus Park Blvd 1650 9 RHG- N•rut Calc =10A Front Dour faces: N
Duct System Summary Job: 6805 Citrus Park Blvd 165...
W I'19htSOft`° Date: 0712412020
House By: LVL
One Stop Cooling and Heating Plan: 1650 B LHG
7225 Sandscove Court. Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling corn License: CAC1817652
For: WADE JURNEY
6805 Citrus Park Blvd, Fort Pierce, FL 34951
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (fEL)
Heating
0
in H2O
0.16
in H2O
-0.2
in H2O
-0.080 /-0.080
in H2O
-0.12
in/100ft
0
cfm
129
Cooling
0.50
in H2O
0.16
in H2O
0.34
in H2O
0.170 / 0.170
in H2O
0.264
in/100ft
740
dim
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BA2
c 372
0
18
0.311
4.0
Ox0
VIFx
14.2
95.0
st1
BED 1
c 1429
0
67
0.282
6.0
Ox 0
VIFx
20.5
100.0
st1
BED2
c 2499
0
118
0.300
6.0
Ox0
VIFx
18.3
95.0
st1
BED3
c 1485
0
70
0.295
6.0
Ox0
VIFx
15.4
100.0
st1
FLEX
c 1540
0
73
0.299
5.0
Ox 0
VIFx
23.6
90.0
st2
KIT
c 2172
0
102
0.264
6.0
Ox 0
VIFx
28.6
100.0
st2
LV
c 2616
0
123
0.293
6.0
Ox 0
VIFx
26.1
90.0
st2
MBA
c 340
0
16
0.293
4.0
Ox 0
VIFx
21.2
95.0
st2
MBED
c 1650
0
78
0.305
6.0
Ox 0
VIFx
21.5
90.0
st2
MWIC
c 742
0
35
0.266
4.0
Ox0
VIFx
33.0
95.0
st2
We 1
c 849
0
40
0.313
4.0
Ox 0
VIFx
13.7
95.0
st1
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfM)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st2
PeakAVF
0
427
0.264
544
12.0
0 x 0
VinlFlx
st1
PeakAVF
0
313
0.282
708
9.0
0 x 0
VinlFlx
wrightsoft-
t . „ • R _, mom, Right-Suite®UnNersal201919020RSU25029
'AM rk BIWd 6805 Citrus Park BI A 1650 B RHG- N.rut Calc = MJ8 Front Doorfaces: N
2020-Sep-23 14:28:16
Page 1
Name
Grille
Size (in)
Htg
(cfm)
Clg
(dm)
TEL
(it)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat
Trunk
rb1
ox0
0
740
0
0
0
0
Ox 0
VIFx
W rlghtsoft- 2020-Sep-23 14:28:16
Right Suite®UnKersal 201919.020 RSU25029 Page 2
/�iCA ...rk BIodW05 Citrus Park Bled 1650 B RHG- N.rut Calc= MJ8 Front Door faces: N
Static Pressure and Friction Rate Job: 6805 Citrus Park Blvd 165...
+ Wrlghtsoft� Date: 07/24/2020
House By- LVL
One Stop Cooling and Heating Plan: 1650 B LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wvwv0neSlopCooling com License: CPC1817652
For: WADE JURNEY
6805 Citrus Park Blvd, Fort Pierce, FL 34951
AvailablePressure
Heating Cooling
(in H2O) (in H2O)
External static pressure 0 0.50
Pressure losses
Coil
0
0
Heat exchanger
0
0
Supply diffusers
0.03
0.03
Return grilles
0.03
0.03
Filter
0.10
0.10
Humidifier
0
0
Balancing damper
0
0
Other device
0
0
Available static pressure
-0 2
0.34
Total•
Supply
Return
(ft)
(ft)
Measured length of run -out
13
0
Measured length of trunk
16
0
Equivalent length of fittings
100
0
Total length
Total effective length
Supply Ducts
Return Ducts
129
Heating
(i n/100ft)
-0.124 < 0.06
-0.124 < 0.06
Fitting Equivalent LengthDetails
Supply 4X=35, 11 A=20, 11 G=5, 11G=5,1A=35: Total EL=100
Return TotalEL=0
0
129
Cooling
(in/100ft)
0.264 > 0.18
0.264 > 0.18
1 * wrightsoft- 2020-Sep-2314:28:16
^AE ..,,,,., Right -Suite® Universal201919020RSU25029 Pagel
ACCK .. rk BIWM05 Citrus Park Blvd 1650 B RHG- N.rut Calc = MJ8 Front Door faces: N
Main
LIV KR
10x6
103 cfm
10x8
110 cfm
M WIC
8x4
36 cfm
SRB 1 4" Bath Duct to Roof
FLEX WIFan
Broan 1688F
10x6
6 " 88 cfm
5 „
4 17 m
80 1 BA MBED
79 cfm 12" 8x4 x4
BED 3 - 24 x 4 10x6
78 cfm
4" Dryer Duct to Roof
Cap wlDryer Vent Box
10x6 T UN 8x4
76 cfm - /BED
42 cfm
24x14 RA W 1!�f740 cfm 1 11CC`���'i1
24 x 4 6„ A/C-1: 2 0 TON
9" 4 140SEER HP.
8x4 BA 2 AC SLAB BY BUILDER
4" Bath Duct to Roof 18 cfm 2' FROM WALL
WIFan
Broan 1688F 6 „ SRB 2 2.0 ton WI5KW @240V 1 PH
14X14 Plen
ON Platform
24 x 4
10x6
94 cfm
BED 2
GAR
Job #: 6805 Citrus Park Blvd 1650 B RHG- N One Stop Cooling and Heating Scale: 1 : 99
Performed by LVL for: Page 1
WADE JURNEY 7225 Sandscove Court RightSuite@ Universal 2019
6805 Citrus Park Blvd Winter Park19.0.20 RSU25029
Fort PiercePhone: (407) 629 - 6920 Fax:: (407) 629 - 9307
, FL 34951 , FL 2020-Sep-23 14:28:03
407
www.OneStopCooling corn trus Park Blvd 1650 B RHG- N rut
\Builders
. FrstSource
S 404045
DAVID GIDDENS (CASH)
D PALM BAY LOCATION
0 PALM BAY, FL 32905
DATE QT NUMBER
***REPRINT*** 12-15-20 51641035
QUOTATION QUOTE Page 1
QT
S 407473 CENTURY COMPLETE
I DAVID GIDDENS (CASH) *YD*
P
T
0
FT.
JOB NO.
CENTURY COMPLETE
CUSTOMER PO. COST CODE
ALL MODELS
EST SHIP DATE
12-25-20
CLERK# SHIPPED FROM
gpb5 PALMFLYD QT
QTY
ITEM NO,
DESCRIPTION
U/M
UNIT PRICE
EXTENDED PRICE
CENTURY COMPLETE - EXTERIOR DO
DR PRICING
1
51641035.10
3068 134SC OS TTSS 6PANEL SM
EA
241.09
241.09
EXTERIOR DOOR
PH 4-9/16 FRAMESAVER JAMBS DEL
BORE STD SILL SATIN NKL HINGES
INSWING
1
INSTALL
------------------------------
INSTALL LABOR
EA
85.00
85.00
**Unless otherwise specified herein, all prices shown shall only be valid for
materials delivered for or received by the Purchaser within 30 days from the
date of this quotation.**
Thenkyou for the opportunity to quote.
SUBTOTAL TAX TOTAL
326.09 16.88 342.9
BFS RETAINS THE RIGHT TO ADJUST ALL QUOTED PRICES IN
THE EVENT OF SHORTAGES, ENVIRONMENTAL IMPACTS,
FREIGHT INCREASES, OR GOVERNMENTAL REGULATIONS,
QUOTATIONS SUBJECT
TO CREDIT APPROVAL
4S