HomeMy WebLinkAboutEngery CalcsFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 6805 Citrus Park Blvd 1650 B RHG- N Builder Name: WADE JURNEY HOMES Street: 6805 Citrus Park Blvd Permit Office: St. Lucie City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1456.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Block, Exterior R=4.1 1164.00 ft2 b. Frame - Wood, Adjacent R=13.0 292.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1650.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1650.00 ft 2 6. Conditioned floor area above grade (ft2) 1650 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11 Ducts R ft2 7. Windows(126.0 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 330 a. U-Factor: Dbl, U=0.35 126.00 ft2 SHGC: SHGC=0.29 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 22.2 SEER:14.50 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d U-Factor: N/A ft2 a. Electric Heat Pump 22.2 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.290 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1650 0 sqft.) Insulation Area EF: 0.920 a Slab -On -Grade Edge Insulation R=0.0 1650.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.076 Total Proposed Modified Loads: 47.77 PASS Total Baseline Loads: 48.32 1 hereby certify that the plans and specifications covered by Review of the plans and 1-KYiE Sr�r this calculation are in compliance with the Florida Energy specifications covered by this 0_ Code. calculation indicates compliance- with the Florida Energy Code ' ':�„ ❑ / PREPARED BY: Z;'2V-t� Before construction is completed DATE: 09/23/20 this building will be inspected for a compliance with Section 553.908 I hereby certify that this bui ' g, designed, is in compliance Florida Statutes. r with the Florida Energy de. �Da WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 9/23/2020 2:33 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 6805 Citrus Park Blvd 1650 B Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1650 Lot # Owner Name: Total Stories: 1 Block/Subdivision: LWP # of Units: 1 Worst Case: No PlatBook: Builder Name: WADE JURNEY HOMES Rotate Angle: 180 Street: 6805 Citrus Park Blvd Permit Office: St. Lucie Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL , 34951 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH AIRPORT 45 90 70 75 369 69 Medium BLOCKS Number Name Area Volume 1 Block1 1650 13200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1650 13200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 145.5 ft 0 1650 ft2 ---- 0.29 0 0.71 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1739 ft' 274 ftz Dark N 0.5 N 0.5 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1650 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1650 ft' 01 Wood 9/23/2020 2:33 PM EnergyGaugeO USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 • : u : - lIllltC-111►TJIJJF\:YKA:I44111]: O1.119 »:1rla11 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below aY QrnL _ To Wall Type_ Space R-V;;his FL __la_ -.Et In Area R4alue Fracliort__Absoc__GradeJ 1 S=>N Exterior Block - Wood Main 4.1 18 0 8 0 144.0 ft' 0 0.25 0.4 0 2 E=>W Exterior Block -Wood Main 4.1 36 6 8 0 292.0 ft' 0 025 0.4 0 3 N=>S Exterior Block -Wood Main 4.1 38 6 8 0 308.0 ft' 0 0.25 0.4 0 4 W=>E Exterior Block -Wood Main 4.1 52 6 8 0 420.0 ft' 0 0.25 04 0 5 -SE Garage Frame - Wood Main 13 36 6 8 0 292.0 ft' 0 0.25 0.4 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>N Insulated Main None .4 3 3 8 20 ft' 2 N=>S Wood Main None .46 2 8 u 17.8 ftZ 3 -SE Wood Main None .46 2 8 6 8 17.8 ft' WINDOWS Orientation shown is the entered orientation => changed to As Built (rotated 180 degrees). / Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S=>N 1 Vinyl Low-E Double Yes 0.35 0.29 N 30.0 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds None 2 E=>W 2 Vinyl Low-E Double Yes 0.35 0.29 N 30 0 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds None 3 N=>S 3 Vinyl Low-E Double Yes 0.35 0.29 N 6 0 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds None 4 N=>S 3 Vinyl Low-E Double Yes 0.35 0.29 N 30.0 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds None 5 W=>E 4 Vinyl Low-E Double Yes 0.35 0.29 N 30.0 ftZ 1 ft 0 in 1 ft 4 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 403 ft' 403 ft' 46 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1540 84.54 159 .1339 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.2 22.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 14.5 22.2 kBtu/hr 666 cfm 0.75 1 sys#1 9/23/2020 2:33 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS ---- Supply ---- --- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 330 ftZ Main 82.5 ftZ Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin ]Jan Feb Mar [ ] A r May X Jun Jul Au X Se f Oct Nov Dec Heating X] Jan X Feb Xj Mar [ ] APr f May 4 Jun Jul rj AuSep �Xj Oct Nov H Dec Ventin [ ] Jan [ Feb X Mar [X] A r [ Ma [ Jun Jul Aug Se [X Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 9/23/2020 2:33 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 6805 Citrus Park Blvd Permit Number: Fort Pierce , FL , 34951 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402 4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveldilie building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air IeakagdNndows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 9/23/2020 2:33 PM EnergyGauge® USA 6 0 02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel -burning appliances. In Climate "Zones 3 through 8, where open combustion air ducts provide combustion ai+ to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1 Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3 3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manuf, air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2 Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 55°F (1 YC) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe ❑ shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 9/23/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.5.5 Heat traps (Mandatory). Storage: water heaters not equipped with integral heat traps and having vertical prpe ris+:fs shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/z inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). ❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). ❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. ❑ R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403 6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMU (CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 9/23/2020 2:33 PM EnergyGauge® USA 6 0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is riot less than ;he calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 2. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, El shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 9/23/2020 2:33 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. ❑ R403.11 Portable spas (Mandatory$e energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high, -,efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 9/23/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1 New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 60 2 Single-family or multiple -family 2. 5inale-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4 Number of bedrooms 4. 4 13 Cooling system: Capacity 22.2 a) Split system SEER 14.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1650 d) Room unit/PTAC EER e) Other 7 Windows, type and area a) U-factor:(weighted average) 7a 0.350 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.290 14. Heating system: Capacity 22.2 c) Area 7c. 1260 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 00 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.92 b) Gas fired, natural gas EF 10 Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1._ 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c d) Multizone cooling credit d) Radiant barrier installed 11d No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be complete d on installed code compliant features. Builder Signature: Date Address of New Home: 6805 Citrus Park Blvd City/FL Zip. Fort Pierce. FL 34951 9/23/2020 2:33:17 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 6805 Citrus Park Blvd 1650 B RHG- N Builder Name: WADE JURNEY HOMES Street: 6805 Citrus Park Blvd Permit Office: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Jurisdiction: 661000 w Design Location FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in an dropped9 ceiling/soffit /soffit insulation and any gaps in the air barrier shall be sealed shall be aligned with the air barrier Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces Garage separation Air sealing shall be provided between the garage and conditioned spac .s Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids betWegEl fire si)rinkler cover plates and walls r ilia a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/23/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary Job: 6805 Citrus Park Blvd 165... - + wrightsoft9 , ry Date: 07/24/2020 House W. LVL One Stop Cooling and Heating Plan: 1650 B LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: www.OneStopCooling com License: CAC1817652 For: WADE JURNEY 6805 Citrus Park Blvd, Fort Pierce, FL 34951 Notes: Weather: FL, Fort Pierce Winter Design Conditions Outside db 43 °F Inside db 68 °F Design TD 25 °F Heating Summary Structure 13431 Btuh Ducts 1382 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 14813 Btuh Method Construction quality Fireplaces Area (M Volume (ft) Air changes/hour Equiv.AVF (cfm) Infiltration Simplified Average 0 He1t64g COMB 13130 13130 0.38 0.20 83 44 Heating Equipment Summary Make Carrier Trade CARRIER Model CH14NBO2400GOA0 AHRI ref 9162301 Summer Design Conditions Outside db 91 °F Inside db 74 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 65 grAb Sensible Cooling Equipment Load Sizing Structure 12819 Btuh Ducts 2875 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturers data n Rate/swing multiplier 0.96 Equipment sensible load 15035 Btuh Latent Cooling Equipment Load Sizing Structure 3581 Btuh Ducts 771 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 4352 Btuh Equipment Total Load (Sen+Lat) 19387 Btuh Req. total rapacity at 0,75 SHR 1.7 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond CH14NBO2400GOA0 Coil FB4CNP025L AHRI ref 9162301 Efficiency 8.2 HSPF Efficiency 11.5 EER,14.5 SEER Heating input Sensible cooling 16650 Btuh Heating autput 22200 Btuh @ 47°F Latent cooling 5550 Btuh Temperature rise 0 °F Total cooling 22200 Btuh Actual airflow 0 cfm Actual airflow 740 cfin Air flow factor 0 cfrnBtuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0.50 in H2O rmostetpoint Load sensible heat ratio 0.78 Capce th = 34 °F Backup: Input =13 kW, Output = 43093 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FP- wrigti n 2020-Sep-2314:28:15 Right -Suite® Universal201919020 RSU25029 Page 1 /tCCp.... k Blvd 6805 Citrus Park Blvd 1650 B RHG- N rut Calc= MJB Front Door faces: N wrightsoft Right-J® Worksheet House One Stop Cooling and Heating Job: 6805 Citrus Park Blvd 1650 B ... Date: 07/24/2020 LVL Pan: 1650 B LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwwvOneStopCooling corn License: CAC1817652 1 Room name House KIT 2 E)posed wall 145 5 ft 12.0 ft 3 Room height 8.0 ft d 8.0 ft heat/000l 4 Room dimensions 12.0 x 125 ft 5 Room area 1641.3 ft2 150.0 fF Ty Construction U-value Or HTM Area (ft') Load Area (W) Load number (Btuh/ft-°F) (BWhAt=) or perimeter (it) (Btuh) or perimeter (ft) (BWh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 0143 ne 352 2.80 308 253 889 708 96 90 317 252 4A5-20v 0320 ne 7,87 17.44 6 0 47 105 6 0 47 105 4A5-20v 0 320 ne 787 17.44 30 0' 236 523 0 0 0 0 11DO 0390 ne 9.59 12o1 19 19 185 231 0 0 0 0 W 11 13A-4ocs 0.143 se 3.52 2.80 292 262 922 734 0 0 0 0 4A-12ov 0 320 se 7.87 1723 30 2 236 517 0 0 0 0 W 13A-4ocs 4A5-2ov 0143 0 320 sw sw 3.52 787 2.80 1723 144 30 94 2 329 236 262 517 0 0 0 0 0 0 0 0 D 11 DO 0.390 sw 959 784 20 20 196 160 0 0 0 0 IW 13A-4ocs 0.143 nw 3.52 2.80 420 390 1372 1093 0 0 0 0. G 4A5-2ov 0 320 nw 7.87 17.44 30 0 236 523 0 0 0 0 T—D 12C-0sw 0.091 - 224 1 A5 292 274 614 397 0 0 0 0 11 DO 0 390 n 9.59 7.84 18 18 169 138 0 0 0 0 C 16B-30ad 0032 0.79 1.74 1641 1641 1292 2852 150 150 118 261 F 22A-4pm 1180 29.03 0.00 1641 146 4224 0 150 12 348 0 6 c)AED excursion 0 -110 Envelopelossrgain 11183 8761 830 508 12 a) Infiltration 2248 808 185 67 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 5 1150 0 0 Applianoes/other 2100 1200 Subtotal (lines 6 to 13) 13431 12819 1016 1774 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 13431 12819 1016 1774 15 Dudloads I 10% 22% 1382 2875 109/a 1 221/a 105 3138 Total room load 14813 15694 1120 2172 Airrequired (dm) 0 740 0 102 Calculations aDDroved NACCA to meet all reauirements of Manual J 8th Ed _ wrigF�tsoit 2020-Sep-2314:28:15 ACCA ._...__.....,_. Right-Suite.anUniversal 201919.0IC-RSU25029 Page -.rk Blvd'6805 Citrus Paris Blvd 1650 B RHG-N rut Calc= MJ8 Frocr Door faces: N wrightsoft• Right-l® Worksheet House One Stop Cooling and Heating Job: 6805 Citrus Park Blvd 1650 B ... Date: 07/24/2020 LVL Pan: 1650 B LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwvw0neStopCooling com License: CAC1817652 1 Room name LAUN FOY 2 Eposed wall O ft 3-5 ft 31 Room height 80 ft heat/000l 80 ft heaNcool 4 5 Room dimensions Room area 70 x 40 ft 280 1? 1.0 x 211.0 ft 2110 ft' Ty Construction U-value Or HTM Area (@) Load Area (W) Load number (BtuhAF °F) (BtuhfiL� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6Vh13AAocs 0.143 ne 3.52 2.80 0 0 0 0 0 0 0 0 4A5-2ov 4A5-2ov 0.320 0.320 ne ne 7.87 7.87 17.44 17.44 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 DO 0.390 ne 9.59 1201. 0 0 0 0 0 0 0 0 11 W 13AAocs 4A5-2ov 0143 0.320 se se 352 7.87 2.80 1723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 13AAocs 0.143 sv 3.52 2.80 0 0 0 0 28 6 27 21 4A5-2ov 0.320 sw 7.87 1723 0 0 0 0 0 0 0 0 11 DO 0.390 snr 9.59 7.84 0 0 0 0 20 20 196 160 IW �--G R 13"ocs 4A5-2ov 12C-096v 0143 0.320 0091 nw nw - 3.52 7.87 224 2-80 17.44 1.45 00 0 0 0 0 0 0 0 0 0 0 0 0 132 0 0 114 0 0 256 0 0 166 I L----D I 11 DO 0 390 n 9.59 7.84 0 0 0 0 18 18 169 138 C 1613-30ad 0.032 0.79 1.74 28 28 22 49 211 211 166 367 F 22A-tpm 1.180 29.03 0.00 28 0 0 0 211 4 102 0 6 c)AED excursion -35 -63 Envelopelosslgain 22 13 915 788 12 a) Infiltration 0 0 54 19 b) Room ventilation 0 0 0 0 13 Intemal gains Occupants @ 230 0 0 0 0 Appliances/other 500 1100 subtotal (lines 6to13) 22 513 969 908 Less exdemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -22 -513 -969 -908 14 Subtotal 0 0 0 0 151 Dudloads 10% 22% 0 0 10% 22% 0 0 Total room load 0 0 0 0 Air required (dm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrrgl-�taoi`C-° 2020-Sep-2314:28:15 - — — • Right-SuiteC0 Universal 201919.020 RSU25029 Page 2 AccK .-.rk BIW'6805 Citrus Paris Blvd 1650 B RHG- N.rut Calc = MJ8 Front Docrfaces: N wrightsoft• Right-J® Worksheet House One Stop Cooling and Heating Job: 6805 Citrus Park Blvd 1650 B... Date: 07/24/2020 LVL Pan: 1650 B LHG 7225 Sandscove Court, Wnter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629- 9307 Web: www.OneStopCooling com License: CAC1817652 1 Room name FLEX 2 Eposed wall 0 ft 10.5 it 3 Room height 8.0 ft heat/000l 80 ft heat/cool 4 Room dimensions 3.5 x 3.0 ft 14.0 x 105 ft 5 Room area 10.5 T 147 0 T Ty Construclion U-value Or HTM Area (ft� Load Area (W) Load number (BtuhAF--'F) (B or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross NrP/S Heat Cool 6 1qJ 0.320 ne 352 2.80 0 0 0 0 0 0 0 0 A5-2ovs 4Arr2ov 0.320 ne 7.87 1744 0 0 0 0 0 0 0 0 ��L—((p`' 4A5-2ov 0.320 ne 787 17.44 0 0 0 0 0 0 0 0 11 DO 0.390 ne 9.59 12011 0 0 0 0 0 0 0 0 11 IW L—G 13A-4ocs 4A-12ov 0143 0 320 se se 352 787 2801 1723i 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 13A4ocs 4A5-2ov 0.143 0.320 sw sw 3.52 7.87 2.80 1723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D 11 DO 0.390 sw 959 7.84 0 0 0 0 0 0 0 0 IW 13A-4ocs 0.143 nw 352 280 0 0 0 0 84 69 243 193 L—G 4A-12ov 0 320 nw 787 17.44 0 0 0 0 15 0 118 262 12C-096v 0 091 - 224 145 28 28 63 41 0 0 0 0 11 DO 0 390 n 959 7.84 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 079 1.74 11 11 8 18 147 147 116 255 l F 22A-tpm 1.180 29.03 000 11 0 0 0 147 11 305 0 6 c)AED excursion -4 55 Envelope loss/gain 71 55 781 766 12 a) Infiltration 0 0 162 58 b) Room ventilation 0 0 10 0 13 Intemal gains. Oo upants @ 230 0 0 0 0 Appliancesbitw 0 300 Subtotal (lines 6 to 13) 71 55 944 1124 Less exlemal load 0 0 0 0 Lesstransier 0 0 0 0 Redistribution -71 -55 143 134 14 Subtotal 0 0 1087 1258 151 Dudloads 100/0 229% 1 0 0 10% 22°/n 112 282 Total room load 0 0 1199 1540 Air required (dm) 0 0 0 73 Calculations aooroved bvACCA to meet all reauirements of Manual J 8th Ed ~ wrigl �ts�fC 2020-Sep-23 14:28:15 ••••- Right -Suite Universal2019 19.020 FSU25029 Page 3 ...rk BI AIC805 Cirrus Park Blvd 1650 8 RHG- N.rut Calc= MJ8 Froni ['uor faces: N wrightsoft- Right-J® Worksheet House One Stop Cooling and Heating Job: 6805 Citrus Park Blvd 1650 B ... Date: 07/24/2020 Bgyy� LVL Pfan: 1650 B LHIG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.com License: CAC1817652 1 Room name BED 3 BA2 2 Exposed wall 10.0 ft 5.5 ft 3 Room height 80 ft heat/cod 8.0 ft heatbool 4 Room dimensions 140 x 10.0 ft 100 x 55 ft 5 Room area 140.0 1F 55.0 it' Ty Construction U-value Or HTM Area (W) Load Area (1F) Load number (BtuhAF--°F) (BtrahAt� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6�13A-flocs 0.320 ne 3.87 2.80 0 0 0 0 0 0 0 0 4AS2ov 0.320 ne 7.87 17.44 0 0 0 0 0 0 0 0 4A5-2ov 0.320 ne 7.87 1744 0 0 0 0 0 0 0 0 11 DO 0.390 ne 9.59 12.01 0 0 0 0 0 0 0 0 IW 11 13A-4ocs 0.143 se 352 2.80 0 0 0 0 0 0 0 0 L—G 4A5-2ov 0.320 se 787 1723 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 sw 3.52 280 0 0 0 0 0 0 0 0 4AS2ov 0 320 sw 7.87 17.23 0 0 0 0 0 0 0 0 11 DO 0 390 sw 959 784 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 nw 3.52 2.80 80 65 229 182 44 44 155 123 4A5-2ov 0.320 nw 7.87 1744 15 0 118 262 0 0 0 0 L-.12C-0sw D 0.091 - 224 1.45 0 0 0 0 0 0 0 0 11 DO 0 390 n 9.59 784 0 0 0 01 0 0 0 0 C 16B-30ad 0.032 0.79 174 140 140 110 243 55 55 43 96 F 22A-tpm 1.180 29.03 000 140 10 290 0 55 6 160 0 6 c)AED excursion 62 -16 Envelopeloss/gain 747 748 358 203 12 a) Infiltration 155 56 85 31 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 0 0 Applianoeslother 0 O Subtotal (lines6 to 13) 902 1034 443 233 Less exdemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 191 179 75 70 14 Subtotal 1093 1213 518 304 15 Ductloads 10% 22% 112 272 10% 22% 53 68 Total room load 1205 1485 571 372 Air required (dm) 0 70 0 18 Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed —1-F wV ghtwcw t- 2020-Sep-2314:28:15 - Right-SuiteOUniversal 2019 19.0.20 RSU25029 Page 4 ;_rk Blvd%6805 Citrus Park Blvd 1650 B RHG- N.rut Calc= MJ8 Front Door faces: N wrightsoft• Right-J® Worksheet House One Stop Cooling and Heating Job: 6805 Citrus Park Blvd 1650 B ... Date: 07/24/2020 LVL Pan: 1650 B LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling corn License: CAC1817652 1 Room name BED 2 BED 1 2 Exposed wall 28 5ft 105 ft 3 Room height 80 It heat/cool I 80 ft heaU000l 4 Room dimensions 10 x 162 3 ft 110 x 105 ft 5 Room area 162 3 T 1155 W Ty Construction U-value Or HTM Area (W) Load Area (ft?) Load number (BtuhV-'F) (BtuhM or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 s 0-320 3.87 2.44 0 0 0 0 0 0 0 0 4A5-2ov A5-2o 0-320 ne ne 7.67 17.44 0 0 0 0 0 0 0 0 4A5-2ov 0.320 ne 7.87 17.44 0 0 0 0 0 0 0 0 D 11 DO 0-390 ne 9.59 1201 0 0 0 0 0 0 0 0 W W 11 13A- ocs 4A5-2ov 13AAors 0.143 0.320 0.143 se se sw 3.52 7.87 352 280 1723 280 20 0 116 20 0 86 70 0 303 56 0 241 84 15 0 69 1 0 243 118 0 193 258 0 0.320 sw 787 1723 30 2 236 517 0 0 0 0 EJD4A5-2ov 11 DO 0 390 s+v 959 784 0 0 0 0 0 0 0 0 IW L—c 13A-0ocs 4A5-2ov 0143 0.320 nw nw 352 787 280 17.44 92 0 92 0 324 0 258 0 0 0 0 0 0 0 0 0 q I—D 12C-0sw 0 091 - 224 1.45 0 0 OI 0 88 88 197 127 11DO 0.390 n 9.59 7.84 0 0 0 0 0 0 0 0 C 16B-30ad 0 032 079 1.74 162 162 128 282 116 116 91 201 F 22A-tpm 1.180 29.03 ODD 162 29 827 0 116 11 305 0 6 c)AED excursion 127 54 Envelope loss(gain 1888 1480 954 834 12 a) Infiltration 440 158 162 58 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliancesiother 10 10 Subtotal (lines 6 to 13) 2328 1869 1116 1123 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redishibuton 184 173 48 45 14 Subtotal 2512 2041 1164 1167 15 Ductloads 10% 22% 259 458 10% 220A 120 262 Total room load 2771 2499 1283 1429 Airrequired (dm) 0 118 0 67 Calculations approved WACCA to meet all requirements of Manual J 8th Ed -4- wrPy! �ttso€t 2020-Sep-23 14:28:15 • ...... ••- -- RigNSuiteeUniversal 201919.0-20RSU25029 Pages -.A BlvdZ805 Citrus Park Blvd 1650 B RHG- N.rut Calc = MJ8 Front Door faces: N - wrightsoft• Right-J® Worksheet Job: 6805 Citrus Park Blvd 1650 B... House Date: 0712412020 LVL One Stop Cooling and Heating P an: 1650 B LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www0neStopCooling-com License: CAC1817652 1 Room name MBED MWIC 2 Exposed wall 11.0 ft 185 ft 3 Room height 8.0 ft heat/cool 80 ft heaV000l 4 5 Room dimensions Room area 14.5 x 11.0 It 159.5 1F 6.0 x 12.5 It 75.0 f1 Ty Construclion U-value Or HTM Area (W) Load Area (W) Load number (BtuhffL'F) (Btuh/r or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross NIPS Heat Cool 6 %1�13A-0ocs 0.143 ne 3.52 280 0 0 0 0 48 48 169 135 4A5-2ov 0 320 ne 1 7.87 17.44 0 0 0 0 0 0 0 0 4A5-2ov 0.320 ne 7.87 17.44 0 0 0 0 0 0 0 0 11 DO 0.390 ne 9.59 12.01 0 0 0 0 0 0 0 0 W 11 13A4ocs 4A5-2ov 0.143 0.320 se se 3.52 7.87 2.80 1723 88 15 73 1 257 118 205 258 100 0 100 0 352 0 280 0 W 13A-4ocs 0.143 sw 3.52 2.80 0 0 0 0 0 0 0 0 4A5-2ov 0.320 sw 7.87 1723 0 0 0 0 0 0 0 0 11 DO 0 390 sw 9.59 7.84 0 0 0 0 0 0 0 O IW R�---G i---D 13A4ocs 4A5-2ov 0143 0 320 nw . 3.52 7.87 2.80 1744 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11DO 0.390 n 959 17.84 0 0 01 OI 0 0 0 0 C 1613-30ad 0.032 079 1.74 160 160 126 277 75 75 59 130 F 22 -tpm 1.180 29.03 0.00 160 11 319 0 75 19 537 0 6 c)AED excursion 42 -42 Envelope loss/gain 820 782 1117 W3 12 a) Infiltration 170 61 286 103 b) Room ventilation 0 0 0 0 13 Intemalgains Occupants@ 230 2 460 0 0 Applianaesbtw 0 0 Subtotal (lines 6to13) 990 1303 1403 606 Less external load 0 0 0 0 LesstransW 0 0 0 0 Redistributon 48 45 0 0 14 Subtotal 1037 13411 1403 606 15 Dudloads 10% 221/n 107 302 10%l 22°/a 144 136 Total room load 1144 1650 1 1547 742 Air required (dm) 0 78 0 35 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -1-- wrights�Tt ^ 2020-Sep-23 14:28:15 ^...-•- - - - Right -Suite® Universal 2019 19.0 20 RSU25029 Page 6 rk l3lA 805 Citrus Park Blvd 1650 B RHG- N rut Calc= MJB Front Door faces: N wrightsoft• Right-J® Worksheet House One Stop Cooling and Heating Job: 6805 Citrus Park Blvd 1650 B ... Date: 07/24/2020 MLVL 1650 B LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: ww ..OneStopCooling com License: CPC1817652 1 Room name MBA WIC 1 2 Exposed wall O ft O ft 3 Room height 80 It heat/cool 8.0 it heat/cool 4 5 Room dimensions Room area 55 x 110 ft 60 5 W 10 x 245 It 24 5 tF Ty Construction U-value Or HTM Area (ftF) Load Area (W) Load number (BtuhAF--°F) (B or perimeter (ft) (Btuh) or perimeter (ft) (BILh) Heat Cod Gross N/P/S Heat Cod Gross NAPS Heat Cod 6 13AAocs 0.143 ne 3.52 280 0 0 0 0 0 O 0 0 4A5-2ov 0.320 ne 7.87 17.44 0 0 0 0 0 0 0 0 4A5-2ov 0.320 ne, 7.87 17.44 0 0 0 0 0 0 0 0 11DO 0.390 ne 9.59 12.01 0 0 0 0 0 0 0 0 Iw L—G 11 13A-4ocs 4A5-2ov 0143 0 320 se se 352 787 280 1723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 w 13AAocs 4A5-2ov 0.143 0.320 sw sw 3.52 7.87 2.80 1723 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D 11DO 0.390 sw 9.59 7.84 0 0 0 0 0 0 0 0 Iw L—c 13AAocs 0143 nw 352 280 0 D 0 0 0 0 0 0 4A5-2ov 12C-Osw 0.320 0.091 nw - 787 224 17.44 1.45 0 0 0 0 0 0 0 0 0 44 0 44 0 98 0 54 11DO 0.390 n 9.59 7.84 0 (3 0 0 0 0 0 0 C 1613-30ad 0.032 0.79 1.74 61 61 48 105 25 25 19 43 F 22Prtpm 1.180 29.03 0.00 61 0 0 0 25 0 0 0 6 c)AED excursion -7 -7 Envelope losstgain 48 98 118 99 12 a) Irfillraton 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliancesldher 0 0 Subtotal (lines 6 to 13) 46 98 118 99 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 191 179 120 594 14 Subtolal 239 277 238 693 15 Dudloads 10% 22°/a 25 62 10% 22°/a 25 155 Total room load 263 340 263 849 Airrequired (dm) 0 16 0 40 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. F wrigF�tsoft•° --••--•- • • - - Right-Suite®Universal 201919.0 20 RSU25029 2020-Sep-2314:28:15 ..-rk BlvM6805 Citrus Park Blvd 1650 B RHG- N rut Calc = MJB Front Doorfaces: N Page l wrightsoft` Right-JO Worksheet House One Stop Cooling and Heating Job: 6805 Citrus Park Blvd 1650 B ... Date: 07/24/2020 LVL Pan: 1650 B LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652 1 Room name LIV 2 Exposed wall 35.5 ft 3 Room height 8-0 ft heaVbool 4 Room dimensions 1.0 x 302.5 It 5 Room area 302.5 fF Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh&-°F) (Btj M or perimeter (ft) (Btuh) or perimeter Heat Cod Gross N/P/S Heat Cod Gross N/PS Heat Cool 6 Ih13A4ors 0.143 ne 3.52 2.80 164 115 404 322 4AS2ov 0 320 ne 787 17.44 0 0 0 0 4A5-2ov 0.320 ne 7.87 17.44 30 0 236 523 11 DO 0.390 ne 959 12.01 19 19 185 231 IW L—c 11 13A-4ots 4A5-2ov 0143 0 320 se se 352 787 2 80 1723 0 0 0 0 0 0 0 0 W 13A-4ors 0.143 sw 3.52 2.80 0 0 0 0 4A5-2ov 11DO 0.320 0.390 sw sw 787 9.59 17.23 7.84 0 0 0 0 0 0 0 0 W L—G cs 13A-4o 4A5-2ov 01431 0320 nw nw 3.52 7.87 2.80 1744 120 0 120 0 422 0 336 0 12C-09w 0 091 I - 2.24 1.45 0 0 0 0 11 DO 0.390 n 9.59 784 0 0 0 0 C 1613-30ad 0 032 079 174 303 303 238 526 F 22A-tpm 1180 29.03 0.00 303 36 1030 0 6 c)AED excursion -56 Envelope loss(gain 2515 1882 12 a) Infiltration 549 197 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 0 0 Applianoesktw 0 Subtdal(lines 6to13) 3064 2079 Lem exiemalload 0 0 Lesstransfer 0 0 Redistribution 61 58 14 Subtotal 3125 2137 151 Dudloads 10% 22% 322 479 Total room load 3447 2616 Air required (cim) 0 123 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �i- wrig F�tsofti ° 2020-Sep-2314:28:15 P'gtit•Suil' Universal 2019 19.020 RSUZ5029 Page 8 ...rk RI WV05 Citrus Park Blvd 1650 9 RHG- N•rut Calc =10A Front Dour faces: N Duct System Summary Job: 6805 Citrus Park Blvd 165... W I'19htSOft`° Date: 0712412020 House By: LVL One Stop Cooling and Heating Plan: 1650 B LHG 7225 Sandscove Court. Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OneStopCooling corn License: CAC1817652 For: WADE JURNEY 6805 Citrus Park Blvd, Fort Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (fEL) Heating 0 in H2O 0.16 in H2O -0.2 in H2O -0.080 /-0.080 in H2O -0.12 in/100ft 0 cfm 129 Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.170 / 0.170 in H2O 0.264 in/100ft 740 dim Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA2 c 372 0 18 0.311 4.0 Ox0 VIFx 14.2 95.0 st1 BED 1 c 1429 0 67 0.282 6.0 Ox 0 VIFx 20.5 100.0 st1 BED2 c 2499 0 118 0.300 6.0 Ox0 VIFx 18.3 95.0 st1 BED3 c 1485 0 70 0.295 6.0 Ox0 VIFx 15.4 100.0 st1 FLEX c 1540 0 73 0.299 5.0 Ox 0 VIFx 23.6 90.0 st2 KIT c 2172 0 102 0.264 6.0 Ox 0 VIFx 28.6 100.0 st2 LV c 2616 0 123 0.293 6.0 Ox 0 VIFx 26.1 90.0 st2 MBA c 340 0 16 0.293 4.0 Ox 0 VIFx 21.2 95.0 st2 MBED c 1650 0 78 0.305 6.0 Ox 0 VIFx 21.5 90.0 st2 MWIC c 742 0 35 0.266 4.0 Ox0 VIFx 33.0 95.0 st2 We 1 c 849 0 40 0.313 4.0 Ox 0 VIFx 13.7 95.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfM) (cfm) FIR (fpm) (in) (in) Material Trunk st2 PeakAVF 0 427 0.264 544 12.0 0 x 0 VinlFlx st1 PeakAVF 0 313 0.282 708 9.0 0 x 0 VinlFlx wrightsoft- t . „ • R _, mom, Right-Suite®UnNersal201919020RSU25029 'AM rk BIWd 6805 Citrus Park BI A 1650 B RHG- N.rut Calc = MJ8 Front Doorfaces: N 2020-Sep-23 14:28:16 Page 1 Name Grille Size (in) Htg (cfm) Clg (dm) TEL (it) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 ox0 0 740 0 0 0 0 Ox 0 VIFx W rlghtsoft- 2020-Sep-23 14:28:16 Right Suite®UnKersal 201919.020 RSU25029 Page 2 /�iCA ...rk BIodW05 Citrus Park Bled 1650 B RHG- N.rut Calc= MJ8 Front Door faces: N Static Pressure and Friction Rate Job: 6805 Citrus Park Blvd 165... + Wrlghtsoft� Date: 07/24/2020 House By- LVL One Stop Cooling and Heating Plan: 1650 B LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wvwv0neSlopCooling com License: CPC1817652 For: WADE JURNEY 6805 Citrus Park Blvd, Fort Pierce, FL 34951 AvailablePressure Heating Cooling (in H2O) (in H2O) External static pressure 0 0.50 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure -0 2 0.34 Total• Supply Return (ft) (ft) Measured length of run -out 13 0 Measured length of trunk 16 0 Equivalent length of fittings 100 0 Total length Total effective length Supply Ducts Return Ducts 129 Heating (i n/100ft) -0.124 < 0.06 -0.124 < 0.06 Fitting Equivalent LengthDetails Supply 4X=35, 11 A=20, 11 G=5, 11G=5,1A=35: Total EL=100 Return TotalEL=0 0 129 Cooling (in/100ft) 0.264 > 0.18 0.264 > 0.18 1 * wrightsoft- 2020-Sep-2314:28:16 ^AE ..,,,,., Right -Suite® Universal201919020RSU25029 Pagel ACCK .. rk BIWM05 Citrus Park Blvd 1650 B RHG- N.rut Calc = MJ8 Front Door faces: N Main LIV KR 10x6 103 cfm 10x8 110 cfm M WIC 8x4 36 cfm SRB 1 4" Bath Duct to Roof FLEX WIFan Broan 1688F 10x6 6 " 88 cfm 5 „ 4 17 m 80 1 BA MBED 79 cfm 12" 8x4 x4 BED 3 - 24 x 4 10x6 78 cfm 4" Dryer Duct to Roof Cap wlDryer Vent Box 10x6 T UN 8x4 76 cfm - /BED 42 cfm 24x14 RA W 1!�f740 cfm 1 11CC`���'i1 24 x 4 6„ A/C-1: 2 0 TON 9" 4 140SEER HP. 8x4 BA 2 AC SLAB BY BUILDER 4" Bath Duct to Roof 18 cfm 2' FROM WALL WIFan Broan 1688F 6 „ SRB 2 2.0 ton WI5KW @240V 1 PH 14X14 Plen ON Platform 24 x 4 10x6 94 cfm BED 2 GAR Job #: 6805 Citrus Park Blvd 1650 B RHG- N One Stop Cooling and Heating Scale: 1 : 99 Performed by LVL for: Page 1 WADE JURNEY 7225 Sandscove Court RightSuite@ Universal 2019 6805 Citrus Park Blvd Winter Park19.0.20 RSU25029 Fort PiercePhone: (407) 629 - 6920 Fax:: (407) 629 - 9307 , FL 34951 , FL 2020-Sep-23 14:28:03 407 www.OneStopCooling corn trus Park Blvd 1650 B RHG- N rut \Builders . FrstSource S 404045 DAVID GIDDENS (CASH) D PALM BAY LOCATION 0 PALM BAY, FL 32905 DATE QT NUMBER ***REPRINT*** 12-15-20 51641035 QUOTATION QUOTE Page 1 QT S 407473 CENTURY COMPLETE I DAVID GIDDENS (CASH) *YD* P T 0 FT. JOB NO. CENTURY COMPLETE CUSTOMER PO. COST CODE ALL MODELS EST SHIP DATE 12-25-20 CLERK# SHIPPED FROM gpb5 PALMFLYD QT QTY ITEM NO, DESCRIPTION U/M UNIT PRICE EXTENDED PRICE CENTURY COMPLETE - EXTERIOR DO DR PRICING 1 51641035.10 3068 134SC OS TTSS 6PANEL SM EA 241.09 241.09 EXTERIOR DOOR PH 4-9/16 FRAMESAVER JAMBS DEL BORE STD SILL SATIN NKL HINGES INSWING 1 INSTALL ------------------------------ INSTALL LABOR EA 85.00 85.00 **Unless otherwise specified herein, all prices shown shall only be valid for materials delivered for or received by the Purchaser within 30 days from the date of this quotation.** Thenkyou for the opportunity to quote. SUBTOTAL TAX TOTAL 326.09 16.88 342.9 BFS RETAINS THE RIGHT TO ADJUST ALL QUOTED PRICES IN THE EVENT OF SHORTAGES, ENVIRONMENTAL IMPACTS, FREIGHT INCREASES, OR GOVERNMENTAL REGULATIONS, QUOTATIONS SUBJECT TO CREDIT APPROVAL 4S