HomeMy WebLinkAboutEvaluation ReportR W R W Building Consultants, Inc.
B Consulting and Engineering Services for the Building Industry
C P.O Box 230 VaInco. FL 33595 Phom 313.659.9197
Florida Board of Professional Errsi—. Cmifrcalc of Aurhodrarm No. 9813
AnchorEvaivation Report ReportNo.: FL-15115.5-80
Dam: September 2l, 2017
Product
Category
Sub Category
Manufacturer
Product Name
Swinging
Therma Tru Corporation
"SmoothStae' and "Benchmark by Therma-Tru"
Exterior
Exterior Door
118 Industrial Dr
8'0 Single & Double Opaque or Glazed Panels w/ & w/o Sidelltes
Doors
Assemblies
Edgerton. 01143517
Inswing IOutswing
Phone 419.298.1740
Insulated Fiberglass Door with Wood Frames
Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for
Therma Tru Corporation, based on Rule Chapter No. 61G2D-3, Method 1A of the State of Florida Product Approval, Dept. of
Business & Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing
or distributing the product or in any other entity involved in the approval process of the product named herein.
Limitations:
1, This product anchoring has been developed in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding
the "High Velocity Hurricane Zone". See the Certification Agency Certificate for sizes, specifications and design pressure ratings.
2. Product anchors shall be as listed and spaced as shown on delails. Anchor embedment to base material shall be beyond wall dressing, stucco, foam,
brick and other wall coverings.
3. Wood screws shall be installed following installations instructions of ANSI AF&PA NDS 2015. All other fastener types to be installed following fastener
manufacture's installation instructions.
4. Fastener embedment depths, edge distance and center -center distances shall be specified by the fastener manufacture, but in no instance shall they
be less than shown in drawing FL-15225.5-80.
5. Where shims are used, they must be a'rigid / stifr material that complies with the requirements of the FBC.
6. Positive and negative design pressure requirements for use with drawing FL-15225.5-80 shall be determined by others for specificjobs in accordance
with the governing code.
7. Site conditions that deviate from the details of drawing FL-15225.5-80 require further engineering analysis by a licensed engineeror registered
architect.
Supporting Documents:
1. Test Report No.
Test Standard
ETC-01-741-10593.0
ASTM E330.02/TAS 202-94
ETC-01.741-10703.0
ASTM E330-02 / TAS 202.94
NCTL 210-1940-1,2,3,4
ASTM E330-02 / TAS 202.94
TEL 01460147
ASTM E330-02I E1886-02 / El996-02
2. Drawing No. Prepared by
No. FL-15225.5-80 RW Building Consultants, Inc. (CA #9813)
3. Calculations Prepared by
Anchoring RW Building Consultants, Inc (CA #9813)
Sheet i of 1
Testing Laboratory Signed by
ETC Laboratories Mark D. Passero, P.E.
ETC Laboratories Wendell W. Haney, P.E.
NCTL Barry Portnoy, P.E.
Testing Evaluation Lab, Lyndon F. Schmidt, P.E.
Signed & Sealed by
Lyndon F. Schmidt, RE,
Signed & Sealed by
Lyndon F. Schmidt, P.E.
iarsi!$q`� C g1s.,a`-Lyndon F. SchmidL P.E.
FL PE No. 43409
9/21/2017
R W R W Building Consultants, Inc.
B Consulting and Engineering Services for the Building Industry
C P.O. a. 230 Vohico, FL 33595 PI— 913.b59.9197
Ronda BoardofPr iorulE�ineers C<ni8wrc ofAmMrfrarion No. 981J
Anchor Evaluation Report Report No.: FU15225.5-68
Date: September 21, 2017
Product
Category
Sub Category
Manufacturer
Product Name
Swinging
Thcrma Tru Corporation
"Smooth -Star" and "Benchmark by Therma-Tru"
Exterior
Exterior Door
118 Industrial Dr
6'8 Single & Double Opaque or Glazed Panels wl & w/o Sidelites
1
Doors
Assemblies
Edgerton, Oil 43517
Inswing /Outswing
Phone 419.298.1740
Insulatod Fiherglass Door with Wood Frames
Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon R Schmidt, P.E. (System ID d 1998) for
Therma Tru Corporation, based on Rule Chapter No. 61G20-3, Method 1A of the Stale of Florida Product Approval, Dept. of
Business & Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt. P.E. do not have nor will acquire financial interest in the company manufacturing
or distributing the product or In any other entity Involved in the approval process of the product named herein.
Limitations:
1. This product anchoring has been developed in compliance with the 61h Edition (2017) Florida Building Code (FBC) structural requirements excluding
the "High Velocity Hurricane Zone'. See the Certification Agency Certificate for sizes, specifications and design pressure ratings.
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing, stucco, foam,
brick and other wail coverings.
3 Wood screws shall be installed following installations instructions of ANSI AFBPA NOS 2015. All other fastener types to be instaued following fastener
manufacturer's installation instructions.
4. Fastener embedment depths. edge distance and center -center distances shall be specified by the fastener manufacture. but in no instance shall they
be less than shown in drawing FL-15225.5-6B.
5. Where shims are used. they must be a'rigid / stiff' material that complies with the requirements of the FBC.
6. Positive and negative design pressure requirements for use with drawing FL-15225.5.68 shall be determined by others for specific jobs in accordance
Wth the governing code.
7 Site conditions that deviate from the details of drawing FL-15225.5-68 require further engineering analysis by a licensed engineer or registered
architect.
Supporting Documents:
I. Test Report No.
Test Standard
ETC-01-741-10702.0
ASTM E330.02I TAS 202-94
ETC-01-741-11008.0
ASTM E330-02 / TAS 202-94
TEL 01460147
ASTM E330-02/E1886-02/E1996.02
2. Drawing No. Prepared by
No. FL-15225.5-68 RW Building Consultants, Inc. (CA #9813)
3. Calculations Prepared by
Anchoring RW Building Consultants. Inc. (CA 99813)
Sheet 1 of 1
Testing Laboratory Signed by
ETC Laboratories Wendell W. Haney, P.E.
ETC Laboratories Joseph L. Dolden, P.E.
Testing Evaluation Lab. Lyndon F. Schmidt, P.E.
Signed & Sealed by
Lyndon F. Schmidt, P.E.
Signed & Sealed by
Lyndon F. Schmidt, P.E.
..........
.y
idc 43r;OJ .��
°6aat; tstacllt Lyndon F. Schmidt. P.E.
FL PE No. 43409
9212017
R R W Building Consultants, Inc.
WConsulting and Engineering Services for the Building Industry
B P.0 Box 230 Valrico, FL 33595 Phone 813.659.9197
Florida Board of Professional G•ngineers Certificate of Authorization No, 9813
Product Sub Category Manufacturer Product Name
Category
7'herma Tru Corporation
V8 Single & Double Opaque or Glazed
Exterior
Swinging
118 Industrial Dr
Doors wi & w/o Sidelites
Doors
Exterior Door
Edgerton, Oil 43517
Outswing
Assemblies
Phone 419.298.1740
Direct to Masonry Installation
Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for
Therma Tru Corporation, based on Rule Chapter No. 61G20-3, Method 1A of the State of Florida Product Approval, Dept. of
Business & Professional Regulation,
RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing
or distributing the product or in any other entity involved in the approval process of the product named herein.
Limitations:
1. This product anchoring has been developed in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding
the "High Velocity Hurricane Zone". See the Certification Agency Certificate for sizes, specifications and design pressure ratings.
2 Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing, stucco, foam,
brick and other wall coverings.
3. Wood screws shall be installed following installations instructions of ANSI AF&PA NDS 2015. All other fastener types to be installed following fastener
manufacturer's installation instructions,
4. Fastener embedment depths, edge distance and center -center distances shall be specified by the fastener manufacture, but in no instance shall they
be less than shown in drawing FL-15225.68M.
5. Where shims are used, they must be a "rigid /stiff' material that complies with the requirements of the FBC.
6. Positive and negative design pressure requirements for use with drawing FLA 5225-68M shall be determined by others for specific jobs in accordance
with the governing code.
7. Site conditions that deviate from the details of drawing FLA 5225-68M require further engineering analysis by a licensed engineer or registered
architect.
Supporting Documents:
1. Test Report No.
Test Standard
TEL 01460145
ASTM E330-02 / E1886-02 / E1996.02
ETC 01-741-11006.0
ASTM E330-02 /TAS 201, 202, 203-94
2. Drawing No.
Prepared by
No. FL-15225.68M
RW Building Consultants, Inc. (CA #9813)
3. Calculations
Prepared by
Anchoring
RW Building Consultants, Inc. (CA #9813)
Testing Laboratory Signed by
Testing Evaluation Lab. Lyndon F. Schmidt, P.E.
ETC Laboratories Joseph L. Dolden, P.E.
Signed & Sealed by
Lyndon F. Schmidt, P.E.
Signed & Sealed by
Lyndon F. Schmidt. P.E.
o
4
f4o 43409
STATE � OF ,'Av
Lyndon F. Schmidt, P.E.
FL PE No. 43409
Sheet 1 of 1 9/21/2017