Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: FP-TANAGER-20 Builder Name: GHO HOMES Street: 3712 TANAGER PL Permit Office: ST. LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34983 Permit Number. Owner: Jurisdiction: Design Location: FL, ST LUCIE_CO INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2321.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2039.30 ft2 b. Frame - Wood, Adjacent R=11.0 282.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (2443.0 sgft.) Insulation Area a. Under Attic (Vented) R=40.0 2443.00 ft 6. Conditioned floor area above grade (ft2) 2443 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 11. Ducts R ft2 7. Windows(330.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Mein 6 664 a. U-Factor: Dbl, U=0.62 330.33 ft2 SHGC: SHGC=0.26 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 56.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 30.1 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Propane Cap: 50 gallons 8. Floor Types (2443.0 sgft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 2443.00 ft2 b. Conservation features b. WA R= ft2 Norte c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.135 Total Proposed Modified Loads: 67.99 PASS Total Baseline Loads: 77.55 I hereby certify that the plans and specifications covered by Review of the plans and S-r this calculation are in compliance with the Florida Energy speciflcatons covered by this O�ZKE Code. v calculation indicates compliance with the Florida Energy Code. PREPARED BY: _ Before construction is completed l " --- - DATE: .._... 7/9/2Q20 __ this building will be inspected for 6, �i compliance with Section 553.908 , ° s is in compliance I hereby certify that7Code. Florida Statutes. with the Florida f''Op WE OWNER/AGENT:_. GOFFICIAL: . -..DATE: - . "7 .. Zd. DATE: I - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifles as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402A.1.2). REVIEWF-D FO CE 000E COMPLIANCE cc 1,UC1IE COUN VT 719/2020 2:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017);;Mpliant Software , Page 1 of 4 ' FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: FP-TANAGER-20 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2443 Lot # Owner Name: Total Stoles: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: GHO HOMES Rotate Angle: 0 Street: 3712 TANAGER PL Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, 34983 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp lnt Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Molsture Range FL, ST_LUCIE CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2443 23697.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2443 23597.1 Yes 4 3 1 Yes Yes Yes FLOORS _ # FloorType_ Space Perimeter R Value _ Area _ Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 211 ft 0 2443 ft2 — 0 0 1 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor, Tested Tested Insui. (deg) 1 Hip Composition shingles 2732 ft' 0 ft' Medium N 0.4 N 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2443 fN N N CEILING _ _ _ # _ Ceiling Type_ Space R-Value — Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 40 Blown 2443 R2 0.1 Wood 7/9/2020 2:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 ' Ff1RM Rdf1F,-9nl7 IMPI IT RI IMMARY f_NFMCI IST RFPCIRT WALLS Cavity Width Height Sheathing Framing Solar Below VAdjacent _.. # Omt To.. Wall Type _ .- __- Space R.Value_ .. -Ft --An Ft In -_ Area- - _R-Vatue-Fraction..-Absor. GradeJ.- 1 N Exterior Concrete Block - Ext Insul Main 4.1 1 5 9 4 13.2 ft' 0 0 0.3 0 _ 2 NE Exterior Concrete Block - Ext Insul Main 4.1 61 11 9 4 577.9 ft' 0 0 0.3 0 3 SE Exterior Concrete Block - Ext Insul Main 4.1 54 10 9 4 511,8 ft' 0 0 0.3 0 4 SW Exterior Concrete Block - Ext Insul Main 4.1 39 8 9 4 370.2 ft' 0 0 0.3 0 5 NW Exterior Concrete Block - Ext Insul Main 4.1 60 8 9 4 566.2 ft' 0 0 0.3 0 _ 6 - Garage Frame - Wood Main 11 30 3 9 4 282.3 ft' 0 0.25 0.3 0 DOORS # Omt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 SW Wood Main None .39 3 8 24 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Omt ID Frame Panes NFRC U-Factor SH_GC_ Imp Area Depth Separation Int Shade Screening 1 no 2 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft' 0 ft 0 in 0 ft 0 in None None 2 ne 2 Metal Double (Clear) Yes 0.62 0.26 N 128.0 ft' 0 It 0 in 0 ft 0 in None None 3 se 3 Metal Double (Clear) Yes 0.62 0.26 N 14.0 ft' 0 ft 0 in 0 ft 0 in None None 4 se 3 Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft' 0 ft 0 in 0 ft 0 in None None 5 sw 4 Metal Double (Clear) Yes 0.62 0.26 N 72.0 ft' 0 ft 0 in 0 It 0 in None None 6 sw 4 Metal Double (Clear) Yes 0.62 0.26 N 8.0 It, 0 ft 0 in 0 ft 0 in None None 7 sw 4 Metal Double (Clear) Yes 0.62 0.26 N 16.0 ft' 0 ft 0 in 0 It 0 in None None 8 nw 5 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 0 ft 0 In 0 ft 0 in None None 9 NW 5 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft' 0 ft 0 in 0 ft 0 In None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 661 ft' 661 ft' 64 It 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 Et.A EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000431 2764.7 151.78 285.44 .1615 7 HEATING SYSTEM # System Type Subtype Speed Efficiency _ Capacity - _ Block Ducts 1 Electric Strip Heat/ None COPA 30.07 kBtu/hr 1 sys#1 7/9/2020 2:44 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 ' FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity —Air Flow _SHR Block_ Ducts 1 Central Unit/ Split Singl SEER: 16 56 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM V. # System Type SubType Location EF_ Cap Use • SetPnt — _ Conservation 1 Propane None Garage 0.9 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply --- — Return— Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 664 ft2 Attic 362 W Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heating Jan Feb Mar Apr I Apr j M:, n Jut JXJ May JuJul n Aug Aug �j Sep Sep Oct Oct( Nov Nov H Dee Dec Venting Jan Feb X Mar n Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 66 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft, 0 112 Oft 0.3 Main 719/2020 2:44 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 88 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple=family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 56.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2443 d) Room uniVPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 30.1 c) Area 7c. 330.3 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level:. a) Slab -on -grade (R-value) 9a. 0.0 b) Wood,.raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF 0.90 A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%o B. Adjacent: g).Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 40.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has compli d with the Florida Building Code, Energy Conservation, through the above energy saving features which will be'instdiled (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed bas don installed code compliant features. Builder Signature: Date: :7/q / 7,.D 2,0 Address of New Home: 3712 TAN OERPI City/FL Zip: FORT PIERCE, FL 34983 7/9/2020 2:44:44 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -- wrightsoft. Load Short Form Entire House Project For: PSL-TANGER-20 3712 TANAGER PL, FORT PIERCE, FL 34983 Job: Date: Jun 30, 2020 By: Design -Information Htg Clg Infiltration Outsidedb (OF) 43 91 Method Simplified Ins ide'db(OF) 70 72 Construction quality Semi -tight Design TD (°F) 27 19 Fireplaces 0 Daily range - L. Inside humidity (%) 30 50 Moisture difference (gr/lb) 0 65 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.8 kW 30073 Btuh 14 OF 1900 cfm 0.062 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make Lennox Trade 16ACX SERIES Cond 16ACX=060-230A Coil CBA25UHV-060-230 AHRI ref 202540573 Efficiency 12.0 EER, 16 SEER Sensible cooling 39200 Btuh Latent cooling 16800 Btuh Total cooling 56000 Btuh Actual air flow 1900 cfm Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.71 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg'AVF (cfm) Clg AVF (cfm) MASTER SUITE 305 4815 4562 297 222 HIS WIC 40 681 464 42 23 MASTER BATH 166 1828 2119 113 103 HER WIC 74 63 259 4 13 DEN 201 4278 4506 263 219 FOYER 69 1502 1943 93 95 DINING 175 2567 3489 158 170 MECH 24 375 627 23 31 UTILITY 68 123 791 8 38 BATH 2 58 1020 924 63 45 BED 2 180 1757 2383 108 116 BED 3 178 1803 2398 111 117 BATH 3 58 1698 1132 105 55 NOOK 73 2277 2103 140 102 KITCHEN l_1E5C AT M R A 2118 AAG 655 CAOM 2338 OCGn 40 13413 114 AAC 'Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r 2020Jul-07 12:05:11 -+ - wrightSOft' Right-SuiteO Universal2012 12.1.05 RSU02818 Page 1 '�vCil1. C:1UserslJasontDocuments\WrightsoR WACIPSL-TANAGER-20.rup Calc = MJ8 Front Door faces: SW U I ILI I'Y I71HLL PANTRY fL 39 Lt55 33, z1v 194 -10 2 19+ 9 Entire House 2442 30848 39072 1900 1900 Other equip loads 0 0 Equip. @ 0.95 RSM 37313 Latent cooling 16066 Irr% Al Q I nAAn I 9AOAD. I G,],]7A I AAAA I AAA V IMI-Q G'f'TL JVV'tV JJJ(.7 1Q VV. I. aVV Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020Jul-07 12:05:11 ..:ij:, + wrightSOft` Right -Suite) Universal 201212.1.05 RSU02818 Page ACCk C:\UsersUasonlDocumentslWrighlsoft HVAMPSI.-TANAGER•20.rup Calo= MJ8 Front Door faces: SW +�+ wrightsoft° Project Summary Entire House For: PSL-TANGER-20 3712 TANAGER PL, FORT PIERCE, FL 34983 Notes: Design Information Weather: Vero Beach Municipal AP, FL,, US Job: Date: Jun 30, 2020 By: Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Heating Summary - Structure 25219 Btuh Ducts 5620 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 30848 Btuh Infiltration Method Construction quality Fireplaces Simplified Semi -tight 0 Heating Cooling Area (ft?) 2442 2442 Volume (fP) 23785 23785 Air changes/hour 0.22 0.11 Equiv. AVF (cfm) 87 44 Heating Equipment Summary Make Trade Model AHRI ref Efficiency 100 EFF Heating input 8.8 kW Heating output 30073 Btuh Temperature rise 14 OF Actual air flow 1900 cfm Air flow factor 0.062 cfm/Btuh Static pressure 0 in H2O Space thermostat Sensible Cooling Equipment Load Sizing Structure 29140 Btuh Ducts 9931 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 37313 Btuh Latent Cooling Equipment Load Sizing Structure 13379 Btuh Ducts 2687 Btuh Central vent (0 cfm) 0 Btuh Equipment.latent load 16066 Btuh Equipment total load 53379 Btuh Req. total capacity at 0.70 SHR 4.4 ton Cooling Equipment Summary Make Lennox Trade 16ACX SERIES Cond 16ACX-060-230A Coil CBA25UHV-060-230 AHRI ref 202540673 Efficiency 12.0 EER, 16 SEER Sensible cooling 39200 Btuh Latent cooling 16800 Btuh Total cooling 56000 Btuh Actual air flow 1900 cfm Air flow factor 0.049 •cfm/Btuh Static pressure 0 in H2O Load -sensible heat ratio 0.71 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsOft' 2020-Jul-0712:05:11 g Right-Suile®Universal 2012 12.1,05 RSU02010 Page 1 C:1UsersXJason%DocumentslWrighlsoft 1-1VAMPSL-TANAGER-20.rup Calc = MJB Front Door faces: SW GHO HOME5 Ff-TANAGEK-20 3712 TANAGER P L FORT PIERCE, FL 34965