Loading...
HomeMy WebLinkAboutLetter; Products Review4 September 17, 2020 ST LUCIE STRUCTURE 4888 N KINGS HWY 225 FORT PIERCE, FL -34951-2244 17-B-78914 BARRY MORRIS FORT PIERCE, FL 40'0" x 100'0" x 16'0" To Whom It May Concern: BUILDING COMPANY A Comerstone Building Brands C;FAPPROVED P DRAINING I SUBIVVI REVIEVY ❑ APPROVED AS NOTED ISEANDRESUBMIT ❑REJECTEDITTAL WAS REVIEWED FOR DESIGN CONFORMITYAND GENERAL CONFORMANCE TO CONTRACT DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRNG AND CORRELATING DIMENIONS AT JOBSITE FOR TOLERANCE, CLEARANCE, QUANT TS S, FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION, COOR INATION OF HIS WORK WITH THEIR DES AND FULL IANCE WITH CONTRACT OCUM NTS By; Data t Architectoinc. frost. Memo.- FL 34950 This is to certify that materials for the subject structure have been designed in accordance with the order documents, specifically.as shown per the attached Engineering Design Criteria Sheet. Aspects of code compliance as related to use or occupancy, such as sprinkler requirements, are not addressed by these documents. These materials, when properly erected on an adequate foundation in accordance with the erection drawings as supplied and using the components as furnished,- will meet the attached loading requirements. This certification does not cover field modification's or the design of materials not furnished by Metallic Building Systems. P The attached design criteria information is to remain with and form part of this Letter of Certification. The calculations and the metal building they represent are the product of Metallic Building Systems or a division of its affiliate Cornerstone Building Brands. The engineer whose seal appears hereon is employed by either Metallic Building Systems or a division of its affiliate Cornerstone Building Brands and is not the engineer of record for this project. Cordially, Metallic Building Systems Materials for Metal Buildings A Cornerstone Building Brands Company Mehrdad Pirataie, P.E., P.E. Engineer IV 17-B-78914 This document has been digitally signed. Page 1 of 3 r BUILDING COMPANY ACCREDITEU A Cornerstone Building Brands Company MAC 0&XmgSx�.f ' AE4?Z Building Code ..................... FLORIDA BUILDING CODE, 6TH EDITION (2017) Building Risk Category ............ Agricultural (Category I) Roof Dead Load Superimposed ................. 2.29 psf Collateral ................... 0.50 psf (0.50 psf Other) Roof Live Load .................... 20.00 psf reduction allowed Wind_ Ultimate Wind Speed (Vult) ... 160.00mph Nominal Wind Speed (Vasd) .... 123 mph (IBC section 1609.3.1) Serviceability Wind Speed .... 87 mph Wind Exposure Category ....... C Internal Pressure Coef (GCpi) 0.18/-0.18 Wall Loads for components not provided by building manufacturer Corner Areas (within 4.00' of corner) 51.76 psf pressure -69.02 psf suction Other Areas 51.76 psf pressure -56.08 psf suction These values are the maximum values required based on a 10 sq ft area. .Components with larger areas may have lower wind loads. 9 17-B-78914 Page 2 of 3 Dim BUILDING COMPANY ACCREDITED' A Cornerstone Building Brands Company M, <NO&,Syw-,, a�au The material supplied by the manufacturer has been designed with the following minimum deflection criteria. The actual deflection may be less depending on actual load and actual member length. BUILDING DEFLECTION LIMITS.......: BLDG-A Roof Limits Rafters Purlins Panels ------------------------------- -------- ------- ------ Live: L/ 180 180 60 Serviceability Wind: L/ 180 180 60 Total Gravity: L/ 180 180 60 Total Uplift: L/ N/A N/A 60 Frame Limits Sidesway --------------------------------------- Live: H/ 180 Serviceability Wind: H/ 60 Total Gravity: H/ 180 Wall Limits Limit ------------------------------- -------- Total Wind Panels: L/ 60 Total Wind Girts: L/ 90 Total Wind EW Columns: L/ 120 The Service Seismic limit as shown here is at service level loads. 17-B-78914 Page 3 of 3