APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
DUNKIN' - 903 E PRIMA VISTA BLVD, PORT ST LUCIE, FL 34952
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
HAD TO MOUNT WALL SIGN ON A WIREWAY FOR PROPER INSTALLATION
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: Es000022s
BUSINESS NAME: KEMP SIGNS & SERVICE INC
QUALIFIERS NAME: STEPHEN M KEMP
ADDRESS: 1740 HILL AVENUE
CITY: WEST PALM BEACH STATE: FL
PHONE (DAYTIME): 561-840-6382
OWNERBUILDER INFORMATION:
NAME: ST LUCIE REALTY GROUP LLC
ADDRESS:469 MARINER DR
CITY: JUPITER
PHONE (DAYTIME: N/A
STATE: FL
ARCHITECT/ENGINEERINFQRM
NAME: CHRISTIAN LANGLEY
ADDRESS: 1200 N FEDERAL HWY#200
CITY: BOCA RATON
PHONE (DAYTIME): 1-888-371-3113
SLCCC. 9/23/09
Revised 06/30/17
STATE: FL
ST. LUCIE CO CERT. #: 3zoza
FAX:
ZIP: 33407
561-840-6385
FAX: N/A
FAX: N/A
ZIP: 33477
ZIP: 33432
EasySeats
easyseals.com
DESIGN CALCULATIONS
DUNI<IN'
DRIVE-THRU LETTERS ON [3AC1<ER
903 E Prima Vista Blvd — Port St Lucie
GENERAL NOTES:
1. Design is in accordance with the Florida Building Code 7th Edition (2020)
for use within and outside the High Velocity Hurricane Zone (HVHZ)1
2. Wind loads have been calculated per the requirements of ASCE 7-16 as
shown herein.
3. These engineering calculations pertain only to the structural integrity of
those systems, components, and/or other construction explicitly
specified herein and/or in accompanying engineering drawings. The
existing host structure (if any) is assumed to be in good condition,
capable of supporting the loaded system, subject to building department
approval. No warranty, either expressed or implied, is contained herein.
4. System components shall be as noted herein. All references to named
components and installation shall conform to manufacturer's or industry
specifications as summarized herein.
S. Where site
conditions
deviate from
those noted herein, revisions may be
required or
a separate
site -specific
engineering evaluation
performed.
6. Aluminum components in contact with steel or embedded in concrete
shall be protected as prescribed in the 2015 Aluminum Design Manual,
Part 1. Steel components in contact with, but not encased in, concrete
shall be coated, painted, or otherwise protected against corrosion.
7. Engineer seal affixed hereto validates structural design as shown only.
Use of this specification by contractor, et. AI, indemnifies and saves
harmless this engineer for all costs &damages including legal fees &
apellate fees resulting from deviation from this design.
This document has been
digitally signed and sealed by
Chrirtian Langley, PE on the
date noted In this digital
signature. Printed copies of
this document are not
considered signed & sealed, &
the signature must be verified
on an� electronic copies.
Serlat6 3CF33811 FF DAEA9D 16 ACEA
Digitally signed
by Christian
Langley
Date: 2021.01.29
12:14:21-05'00'
Index:
Pg 1 Cover
Pg 2 Wind Loads
Pg 3 Anchor Design
auuunnr��
Engl�al�;�ir t1r eal valid
to
No.67382
*: * •:ire
'd STATE OF
A an 29
Chrrsjt E� i#67382
Easy SE='dl9n11111d Auth # 31124
1200 N Federal Hwy, #200 Easy Sea Is .com Page 1 Boca Raton, FL 33432
Easy Seals
ASCE 746 Design Wind Loads
WALL -MOUNTED SIGNS
Building Specs
V= 160mph
Exposure C
Calculations
-a=9.5
zg = 900'
Gcpi = 0
Basic wind speed (Volt)
3-sec gust speed power law exponent
Nominal ht. of atmos. boundary layer
Internal pressure coeff
160
mph
- Exp
"C"
WALL -MOUNTED
SIGNS
ASD
WIND
PRESSURES
SIGN
CENTER
CORNER
HEIGHT
(Zone
4)
(Zone 5)
15
ft
31.2 psf 39.7
psf
20
ft
33.2
psf
42.2
psf
25
ft
34.8
psf
44.2
psf
30
ft
36.1
psf
46.0
psf
35
ft
37.3
psf
47.5
psf
40
ft
38.4
psf
1 48.8
psf
45
ft
39.3
psf
_ 50.1
psf
50
ft
40.2
psf
51.2
psf
55
ft
41.0
psf
52.2
psf
60
ft
41.8
psf
53.2
psf
70
ft
35.3
psf
€ 70.6
psf
80
ft
36.3
psf
1. 72.6
psf
90
ft
37.2
psf
74.5
psf
100
ft
38.1
psf
76.1
psf
110
ft
38.8
psf
€ 77.7
psf
120
ft
39.6
psf
79.1
psf
130
ft
40.2
psf
1 80.5
psf
140
ft
40.9
psf
81.7
psf
150
ft
41.5
psf
82.9
psf
175
ft
42.8
psf
85.7
psf
200
ft
44.1
psf
88.1
psf
250
ft
46.2
psf
92.3
psf
CALCULATIONS FOR WALL -MOUNTED SIGNS
ASD Load Combo Coeff: 0.6
Kd =
0.85
Directionality factor
Kzt =
1.0
Topographic foctor
Ke =
1.0
Ground elevation foctor
A =
10 sq ft
Tributary area
0.85
28.4
-1.10
-1.40
0.90
30.1
-1.10
-1.40
0,95
31.6
-1.10
-1.40
0.98
32.8
-1.10
-1.40
1.01
33.9
-1.10
-1.40
1.04
34.9
-1.10
-1.40
1.07
35.8
-1.10
-1.40
1.09
36.6
-1.10
-1.40
1.12
37.3
-1.10
-1.40
1.14
38.0
-1.10
-1.40
1.17
39.2
-0.90
-1.80
1.21
40.4
-0.90
-1.80
1.24
41.4
-0.90
-1.80
1.27
42.3
-0.90
-1.80
1.29
43.2
-0.90
-1.80
1.32
44.0
-0.90
-1.80
1.34
44.7
-0.90
-1.80
1.36
45A
-0.90
-1.80
1.38
46.1
-0.90
-1.80
1.42
47.6
-0.90
-1.80
1.46
48.9
-0.90
-1.80
1.53
51.3
-0.90
-1.80
Easy Seals
Wall Sign Anchor Design
Structure Dimensions & Loading
Design wind pressure:
Sign type:
Sign size:
CALCULATIONS FOR WALL -MOUNTED SIGNS
P = 46.0 psf
Backer/Wireway
A = 19.5 sqft (entire backer/wireway)
Wall material: Masonry (ASTM C90, 1,500 psi min)
Anchor type/size: 3/8" Large Diam Tapcon
Ref: Red Head LDT, catalog
Min Embedment: 15'
Min edge dirt: 4" Min Spacing: 4"
Anchor tensile capacity: Tcap = 229.0 Ib (per anchor)
Check Anchors for Pullout
Total Reaction: Rt = 895 Ib = P'A (entire hacker(wirewayj
No. of anchors req'd: n = 3.9 total anchors ... = Rt/cap
Total anchors required: 4 total anchors balanced over backer/wireway
OK, typical anchor option shown. Limit to min (8) total.
Ref anchor schedule for other anchor options.
ALLOWABLE: 32'+ 1.5' for each lineal ft over 20'=68.9'
(32' + 44.6'-20'=24.6'x1.5'=36.9') Pink
RETURNS: Gray
EXISTING: ' TRIM CAP: Bronze -
PROPOSED:19.47" WIREWAY ;Painted to match
building
�� �,�„
EXISTING
PROPOSED
C �4D
5,e-~ ED LIGHTS
REF ANCHOR SCHEDULE
FOR MOUNTING OPTIONS
�,. �._
TO MATCH BUILDING
#8x'I /2" Self Dulling
screws to hold Jewelite
Mmcap to alum. letter
Minimum 4 per lettef
Drain Holes in letters if used
in wet or damp locations
(120VOLTfL04MP)VVEATHER PROOF) -BOX WITH DISCONNECT
SWITCH ON WALL
BUSHING THROUGH METAL LETTER TO PREVENT
WIRE PROM GETTING CUT
PRIMARY ELECTRICAL SOURCE
NEC 600-6 t/2" MIN. CONDUIT
me an[emem ha: been
digitally signed and sealed by
(hrrstian Langley, PE on the
2V LED POWER SUPPLY date noted in this digttal
signature. Printed copies of
this document a not
onsidered signed &sealed, &
the signature must be verified
Conelsts of ohannel letters ona�yaeleQmvi[omD�i'aura
N
and disconnect switch.
Suitable for damp, wet or Digitally signed
outdoor locations. by ChFlstldn
Wall
All building penetrations Langley
sealed, to comply with Date: 2021.01.29
applicable bldg. code req.
1
12:14:32-OS'00'
ANCHOR SCHEDULE
qTY or SPACING
MATE0.IAL
ANCH00.TTPE
HOLLOW MAskO'N0.Y
3/e"THREADED ODS WITH MIN 2"EMBED IN ADHESIVE
MIN ISD)TOTAL
a/e"TA CONS IOR EquIv WITH 2.5"EMBEp
IN (8)TO
3/8"EXPANSION ANCHORS WITH 3.8"EMBED
MIN IB)TOTAL
1/2"PLYWOOD
IND ACCESS BEHINo)
3/B"TOGGLE BOLTS
MIN (8)TOTAL
1/4"WOOD SCREWS, FULL EM
MIN IH)TOTAL
UDs/PANELS
N14 METALBCREWET0 MIN 18gaDSTEELo0. D.D9n"ALUM
MIN IB)TOTAL
3/e"THRUBDITS DR rAG5T0 cKING BEHIND
MIN I&J TOTAL
I ELECTRICAL NOTES I
Primary wire size - #12 THWN
Disconnect switch: at base of sign, 20 amp single pole. Astronomical time
clock of panel room or photocell
Maximum load - 16 amps 120 volts per circuit maximum circuit size 20 amps
per NEC 600-6A
Power supply-120v-277 Multi Volt 60w 12v DC
Illumination-Osram .75watis per module
Conduit -minimum 1/2
Total sign load - 2.4 amps 120 volts
Total sign circuits- 1
All components shall be U.L, approved
Ballasts shall have independent U.L. approval (fused where required)
All installations shall be incompliance with NEC and state, county, or local codes
All signs shall be bonded to building equipment bonding conductor per NEC 250
1740 HILL AVENUE CUSTOMER: DESIGNER: Pam Reeves COPYRIGNT 2016 State of: Florida
BY KEMP SIGN 6 County Of: Palm Beach
DATE: 09.11.2020 SERVICE. ALL �.—�-
WEST PALM BEACH, FL • pIGHTS RESERVED -=/ The forgoing document was acknowledged
33407 D u N K I N before me_day of
_ 561-840-6382 903 E. PRIMA VISTA BLVD qLL ELECTRICAL E50000229
TO BE U L LISTED
FAX: 561-840-6385 PT ST LUCIE, FL �� DDMPONENTS AND Electrical Qualifier: p P Your Name Here, Notary Public
sxALL MEET qll Ste hen M. Kem N commission Expires
ES0000229 x.E.c. srAxDARDs
«�
c
,'e
V N
��
6
C M
O
Ev
3�
General •0eslgn lsinattoNamewdh therequlremmts oftheFW Bldg Code7ih Ed(2D2D)forusewithln&ouaidethe HighVelo[iry HurcicaneZone(HVHZ).•mis engineedng certifiesonlythestruauml integriryMthosesys[ems,components, anNorothercons[mGion expllcittyspetlfied herein. •Bechicalrrotes,details,&specifi[adons are provided byantl arethesole responsibiliryof[heeletlrical contra[roLNoele[tn[al review hasbeen performed and notertifiwGvnofsu[h is intended.•Stm[tu2ldesign meetsregtllremen6ofA(131&14,A6C36o-16, ABM7-75,&NUS-18,
Notes: as appli[able.�5teel components shall be coaled,painted, or otherwise prolttl[d against corrosion per FHCSe[Rm.2/lUS.6.•Alum mmponenb in mn[aR with steel or embedded in concrete shall be painted or protttted as prescribed in AUMI-1517a), or plastidneoprene spacers prmided.�All eXposed listeners shall be SS. or haves pmtecdve coatingfvr[ormsion pmtecdon.•All wddirg shall[anply with AWS requirements.•Sted welds: E7ExX eleRmdes.•Aluminum welds: 4043 filler alloy.�Alum extrusions: 6p63-T6 or monger, U.N.U.