HomeMy WebLinkAboutREVISION PACKET - SCL2010-0420OFFICE USE ONLY:
DATE FILED:
REVISION FEE:
PERMIT # SLC2010-0420
RECEIPT #
PLANNING &DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772) 4629553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
DUNKIN' - 903 E PRIMA VISTA BLVD, PORT ST LUCIE, FL 34952
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
HAD TO MOUNT WALL SIGN ON A WIREWAY FOR PROPER INSTALLATION
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: Es000022s ST. LUCIE CO CERT. #: 32o2a
BUSINESS NAME: KEMP SIGNS &SERVICE INC
QUALIFIERS NAME: STEPHEN M KEMP
ADDRESS: 1740 HILL AVENUE
CITY: WEST PALM BEACH STATE: FL ZIP: 33407
PHONE (DAYTIME): 561-840-6382 FAX: 561-840-6385
OWNER/BUILDER INFORMATION:
NAME: ST LUCIE REALTY GROUP LLC
ADDRESS: 469 MARINER DR
CITY: JUPITER
PHONE (DAYTIME: N/A
STATE: FL
ARCHITECT/ENGINEER INFORMATION:
NAME: CHRISTIAN LANGLEY
ADDRESS: 1200 N FEDERAL HWY #200
CITY: BOCA RATON STATE: FL
PHONE (DAYTIME): 1-888-371-3113
SLCCC: 9/23/09
Revised 06/30/17
FAX: N/A
FAX: N/A
ZIP: 33477
ZIP: 33432
EasySeals
easyseals.com
DESIGN C/�LCULATIONS
FOR
DUNI<IN'
ID LETTERS ON 13ACICER
903 E Prima Vista Blvd — Port St Lucie
1. Design is in accordance with the Florida Building Code 7th Edition (2020)
for use within and outside the High Velocity Hurricane Zone (HVHZ)1
2. Wind loads have been calculated per the requirements of ASCE 7-16 as
shown herein.
3. These engineering calculations pertain only to the structural integrity of
those systems, components, and/or other construction explicitly
specified herein and/or in accompanying engineering drawings. The
existing host structure (if any) is assumed to be in good condition,
capable of supporting the loaded system, subject to building department
approval. No warranty, either expressed or implied, is contained herein.
4. System components shall be as noted herein. All references to named
components and installation shall conform to manufacturer's or industry
specifications as summarized herein.
6. Where site
conditions
deviate from
those noted herein, revisions may be
required or
a separate
site -specific
engineering evaluation
performed.
6. Aluminum components in contact with steel or embedded in concrete
shall be protected as prescribed in the 2015 Aluminum Design Manual,
Part 1. Steel components in contact with, but not encased in, concrete
shall be coated, painted, or otherwise protected against corrosion.
7. Engineer seal affixed hereto validates structural design as shown only.
Use of this specification by contractor, et. Al, indemnifies and saves
harmless this engineer for all costs & damages including legal fees &
apellate fees resulting from deviation from this design.
This domment has been DI Itai� SI ned
digitally signed y, PE an he 9 y g
(hdstian Langley, is di the b Christian
date noted in this digital by
Christian
Printed copies of Langley
this document are not g y
considered signed &sealed,& Date: 2021,01.29
the signatu re must he verified
u1,a"fit` Sieiiic colless. 12412:00-05'00'
Index:
Pg 1 Cover
Pg 2 Wind Loads
Pg 3 Anchor Design
dtuuuunte
Eng;�s X t�ir t�seal valid
No.67382
c
.,�• STATE OF
�,n.• F Jan 29 �2t•
Christia7%� ��!`QE#67382
Easy biAInuIIIIS Auth # 31124
1200 N Federal Hwy, N200
Roca Raton, FL 33432 Easy Seals.�om Pdge 1
_ EasySeals
ASCE 7-16 Design Wind Loads
WALL -MOUNTED SIGNS
Building Specs
V= 160 mph Basic wind speed (Vult)
Exposure C
Calculations
a=9.5 3-sec gust speed power law exponent
Zg = 900' Nominal ht. of atmos. boundary layer
Gcpi = 0 Internal pressure coeff
CALCULATIONS FOR WALL -MOUNTED SIGNS
ASD Load Combo Coeff: 0.6
Kd=
0.85
Directianalityfactor
Kzt =
1.0
Topographic factor
Ke =
1.0
Ground elevation factor
A =
10 sq ft
Tributary area
160 mph - Exp
WALL -MOUNTED
"C"
SIGNS
ASD WIND PRESSURES
SIGN
CENTER
CORNER
1EIGHT
(Zone 4)
(Zone 5)
Kh
= Kz
q:
GCp (4)
GCp (5)
15
ft
31.2
psf
39.7
psf
0.85
28.4
-1.10
-1.40
20
ft
33.2
psf
42.2
psf
0.90
30.1
-1.10
-1.40
25
ft
34.8
psf
44.2
psf
0.95
31.6
-1.10
-1.40
30
ft
36.1
psf
[ 46.0
psf
0.98
32.8
-1.10
-1.40
35
ft
37.3
psf
47.5
psf
1.01
33.9
-1.10
-1.40
40
ft
38.4
psf
I 48.8
psf
1.04
34.9
-1.10
-1.40
45
ft
39.3
psf
50.1
psf
1.07
35.8
-1.10
-1.40
50
ft
40.2
psf
51.2
psf
1.09
36.6
-1.10
-1.40
55
ft
41.0
psf
i 52.2
psf
1.12
37.3
-1.10
-1.40
60
ft
41.8
psf
53.2
psf
1.14
38.0
-1.10
-1.40
70
ft
35.3
psf
70.6
psf
1.17
39.2
-0.90
-1.80
80
ft
36.3
psf
72.6
psf
1.21
40.4
-0.90
-1.80
90
ft
37.2
psf
€ 74.5
psf
1.24
41.4
-0.90
-1.80
100
ft
38.1
psf
I 76.1
psf
1.27
42.3
-0.90
-1.80
110
ft
38.8
psf
77.7
psf
1.29
43.2
-0.90
-1.80
120
ft
39.6
psf
79.1
psf
1.32
44.0
-0.90
-1.80
130
ft
40.2
psf
80.5
psf
1.34
44.7
-0.90
-1.80
140
ft
40.9
psf
81.7
psf
1.36
45.4
-0.90
-1.80
150
ft
41.5
psf
82.9
psf
1.38
46.1
-0.90
-1.80
175
ft
42.8
psf
85.7
psf
1.42
47.6
-0.90
-1.80
200
ft
44.1
psf
88.1
psf
1.46
48.9
-0.90
-1.80
250
ft
46.2
psf
92.3
psf
1.53
51.3
-0.90
-1.80
EasySeals
Wall Sign Anchor Design
Structure Dimensions & Loading
Design wind pressure:
Sign type:
Sign size:
CALCULATIONS FOR WALL -MOUNTED SIGNS
P = 46.0 psf
Backer/Wireway
A = 36.0 sqft (entire backer/wireway)
Wall material: Masonry (AsrM c9o, isoo psi minl
Anchortype/size: 3/8" Large Diann Tapcon
Ref: Red Head LDT, catalog
Min Embedment: 1.5"
Min edge dirt: 4" Min Spacing: 4"
Anchor tensile capacity: Tcap= 229.0 Ib (per anchor)
Check Anchors for Pullout
Total Reaction: Rt = 1654 Ib ... = P*Fl (entire backerJwireway)
No. of anchors req'd: n = 7.2 total anchors ... = Rt/cap
Total anchors required: 8 total anchors balanced over backer/wireway
OK, typical anchor option shown. Limit to min (10) total.
Ref anchor schedule for other anchor options.
i
ALLOWABLE: 32'+ 1.5' for each lineal ft over 20'=65'
(32' + 42'-20'=22'x1.5'=33')
EXISTING: '
PROPOSED:36'
EXISTING
72 �a�—
PROPOSED
D
42'
FACES: Orange
Pink(apostrophe)
RETURNS: Gray
TRIM CAP: Bronze -
WIREWAY :Painted to match
building
MIN l3) #10 SMS
PER LETTER
TO MATCH BUILDING
#Sxl2" Self Drilling
screws to hold Jevdelite
trimcap to alum. letter
Minimum 4 per letef
Drain Holes in letters if used
in wet or damp locations
�4rr =��'�� Rim�G7382
ED LIGHTS � �
STATE OP
REF ANCHOR $CHEDUL ���, ,{. >,yy,
FOR MOUNTING OPTIONSy �• ; � Rt�,
h+uuaauLL
8 �1 V0 LT/10AMPJwEATHER PROOF J-BOX WITH
SWITCH ON WALL
m[�.-rmm
WALLMNTERUIL
CONCRETE (3kzi)or
HOLLOW MASONRY
1/2" PLYWOOD
(NO ACCESS EEHINOI
METALSNOS/PANELS
HOLLOW WALL, BLOCKING
Lti
r
METAL LETTER TO PREVENT
JG CUT
ELECTRICAL SOURCE
i t/2" MIN. CONDUIT
This document has been
dlghally signed and sealed 6y
2V LED POWER SUPPLY Chtlstlan Inngley, PE an the
date noted In this digital
signature. Printed copies of
this documem a oat
ronsidered signed &sealed �
the signature must be verified
Consists of channel letters osetiiw>iii enzcwi�sosicncu
and disconnect switch.
Suitable for damp, wet or Digitally signed
outdoor Iocetions. by Christian
Wall
All building penetretions Langley
sealed, to comply with Date:2021.01.29
applicable bldg. code req. 12:11:49-OS'00'
RLDCKING BEHIND
QTY or SPACING
Primary wire size - # 12 THW N
Disconnect switch: at base of sign, 20 amp single pole. Astronomical time
clock al panel room or photocell
Maximum load- 16 amps 120 volts per circuit maximum circuit size 20 amps
per NEC 600-bA
Power supply-120v-277 MuNi Volt 60w 12v DC
Illumination-0sram .75watts per module
Conduit -minimum 1/2
Total sign bad - 2.4 amps 120 volts
Total sign circuits -1
All components shall be U.L. approved
Ballas}s shall have independent U.L. approval (fused where required)
All ins}allations shall be in compliance wi}h NEC and state, county, or bcal codes
All signs shall be bonded to building equipment bonding conductor per NEC 250
1740 HILL AVENUE CUSTOMER: DESIGNER: Pam Reeves COPYRIGHT S01G State of: FlFlda
BY REMV SIGH 8 County of: Palm Beach
DATE: 09.11.2020 SERVICE. ALL ��'M.���
WEST PALM BEACH FL _=/ Thek J°ing daument was acknowledged
� r � u N K I N' RIGHTS 0.r5ERVED t1efOR me_day of _
33407 ALL ELECTRIGL ESODOOJ29
561-840-6382 903 E. PRIMA VISTA BLVD T° °� °•� L'�'E° Your Name Here, Notary Public
COMPONFNISANO Electrical Qualifier.
FAX: 561-840-6385 PT ST LUCIE, FL D �, SHALL MEET ALL Stephen M. Kemp My Commission Expires:
I=_s0000zzs R.E.D. STARD.RDS
k?
e
e
vNv
„ a
oY
p, +1
Ev
o v
0 0`
3�
X �•
Eil
r�
ram
u �I
piY
o
rn
20
rn n
rv�
o
O V
va
m 'o
v�
Yo
c a
-v
o-
E
�%
w
� N
nq
N O
<�
3
General•OesignlslnaaoNanmwiththerequlremennoftheFW Bldg Code7th Ed 0020)forusewuhin lV ou6idetheHighVelairy HumcaneZore(HVHZ).•This englnewing rertifiesonrythestmuural integrity ofthosesys[ems,mmponenG,and/orotherronstnrctlanea#icitlyspecified hereln.•Bemiral notes,details,&spaificatlonsarepmvided byand arethesolerespomibilityoftheelertdral mntranor. Noelenricnl review hasbeen perfoimedand noremfiationofsuchulnteMed.•StmtluNl design meetsrequiremenaoFAC131B-14.AI5C360-16, ABM1-15,&NDS-18,
Notes: as apPlirable.•Sfeel components shall be coated, paintey or o[heiwise pmteaed against mnosion per FBCSec 11031/2722.6.•Num romponenfs in wntad with steelaembetlded In mnuete shall be painted or pmtecRd as prguibed in ADA11-15(1a), or plastitlneoprene spa[ers prwided.•All eryosed hsfeners shall be SS. or hareapmtettive coating(or[amsion pmM[tlon.•All welding shall comply wiN AV)S requirements. -Steel weldx E70xK eleclmdex-Aluminum welds: 4043 filler alloy.•Alum exhusions: 6063-i6 mAmnger, II.N.O.