Loading...
HomeMy WebLinkAboutREGULATOR SPECS - 2-4-21Bulletin LP-7: R122H March 2010 Type R122H First -Stage Regulator Introduction The Type R122H is an Underwriters Laboratories listed regulator designed for Two -Stage LP -Gas systems. The unit is designed to reduce the tank pressure to an outlet pressure of 10 psig. The compact size makes it ideal for small domestic applications and underground tanks. The outlet pressure setting is nonadjustable and is factory set at a nominal 10 psig. Screened drip - lip vents are oriented over the outlet as standard. Features • 20 Year Recommended Replacement Life - The R122H is designed using rugged time proven design concepts and constructed of corrosion resistant materials, both internally and extemally. With proper installation and periodic inspection and maintenance the R122H regulator will meet a 20 Year Recommended Replacement Life. • Dual Gauge Taps - Built-in 1I8 inch NPT gauge taps orificed to a number 54 drill size on both the inlet and outlet side of the regulator allow for easy testing. • Durability - A fluorocarbon valve disc is utilized to improve lockup performance in systems with contaminated gas. • Improved Regulation - A large fabric -reinforced diaphragm and stabilizer clip deliver accurate and stable regulation. Easy Installation - The units compact size and easily accessible inlet and outlet wrench flats make installation easy even in the tightest installations. FISHER Figure 1. Type R122H Forst -Stage Regufator Superior Overpressure Protection - The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UL standards. When used in conjunction with a R622 or R652, the two -stage system will limit the downstream pressure from the second -stage to 2 psig even in a double failure situation. Corrosion -Resistant - Added corrosion resistance from an internal and external coating process for all castings prior to painting, stainless steel relief valve spring and retainer and a corrosion resistant relief valve seat. Positive Draining Spring Case - When installed properly with the spring case vent pointed down, the design allows moisture formed in the spring case to drain out limiting the problems with corrosion and freezing water in the spring case. EMERSON. Process Management Bulletin LP-7: R122H Table t. Ordering lnformalron TYPE NUMBER CAPACITY BTUIHR CONNECTIONS NOMINAL OUTLET SETTING PROPANEt11 I INLET x OUTLET R 122FMA.1 1.100.000 114drtth x 1124ncn NPT 10 psrg (0.69 bw) i Ca> M o basso on 30 K* aff eon asret aeswra =4 M% d-eop ue.1e W a I11, Figure 2. Type R122H Dimensions "Wiens (mm) L1%4= EgWprneM Emerson Process Manapment Regulator Teohnabgfes. tna. USA - Headquarters MdUmM, Texas 75E89-18n USA Telt'pham: 1 (i300) 558-5853 TekTharre: l (972) 546-3574 For further alfornration visit www.fisherregulators.aomAp The Emerson bae is a Mbmv% and smvft mark of Emww Elacirtc Co. Ae Wer marks am the XcWty of that psagwMe owners. Ftshor is a mark Owned CN Fww COrCUL Cm.. a bwwwa d Eatomm Probes mumpowl The Q01 , a1 Orb p1 Lt10e are preeasdsd fbr btlDrrn tWW awpos aft VW wale every effort has teen MWO to omm Mw aemway. they are nor b be Construed as aarrattbos or Orr uw taw eWass ar trrtpttee, raQBtorrq Ore prodttUs or eencoes desamed herettt Or than use ar axzmb ft. vye massive ate mitt tD rMsotly Or anwm Ota des** or speemcafta of wadi proarrets a1 any tttrre wreltou aonso. Eirreraon Pntsess tdahagwou does eat assume raspy for the seledan. use or =Tdonarm at any product Respo wwty for proper se cwk use and msaroarw w of any Fsnnraon Ftooess ItZMgenant product cesrra%ss 20* with the PLVChasay EMERSON. 9 nretson Prooase I11, errt ReO.=WTeW%ftg es. ft, 2=. 2010. AP RWU Rwervt d Process Management Bulletin 71.1:R622 Type R622 Pressure Reducing Regulator • Comp ,+ no�f r • Protei Scree • Hirth Canarity • Inlet and Outlet Pressure Gauge Taps Figure r. 7ype R622 Pres-cure Reducrnq Requiem Introduction Type R622 direct -operated. spring -loaded regulators provide economical pressure reducing control in a variety of residential. commercial. and industrial FISHER Relief /eight applications. These regulators can be used mdh natural. manufactured. or propane gases and have the same inlet and outlet pressure capabilities. :j EMERSON Bulletin 71.1:R622 Specifications Body Size and End Connection Style0) Pressure Registration 112 NPT inlet and outlet Internal Maximum Allowable Inlet PressureM Operating: 125 prig (8,6 bar) Emergency: 125 psig (8,6 bar) Except 1.8 to 2.24nches w.c. (4 to 5 mbar) spring range which has operating and emergency pressures of 60 psig (4,1 bar) Maximum Allowable Outlet (Casing) Pressurell) Operating to Avoid Internal Part Damage: 3 psid (0,21 bar d) above outlet pressure setting Emergency: 20 psi (1,4 bar) Outlet Pressure Ranges See Table 1 Orifice Size 1/84nch (3,2 mm) orifice Flow Coefficients Wide -Open C. for Relief Sizing: 12.5 Wide -Open Cv for Relief Sizing: 0.36 Cl: 35 IEC Sizing Coefficients xT 0.78 FD: 0.82 FL: 0.89 Flow Capacities See Table 2 Relief Performance See Figure 4 Internal Relief Performance Start -to -Discharge is 8 to 22-inches w.c. (20 to 55 mbar) for setpoints from 1.8 to 20-inches w.c. (4 to 50 mbar) Start -to -Discharge is 140 to 200% over setpoint from 20-inches w.c. to 2.2 psig (50 to 152 mbar) Spring Case Vent Connections 3/4 NPT with removable screen Temperature Capabilities( ) -20° to 160°F (-29- to 71"C) Approximate Weight 2.35 pounds (1 kg) Construction Materials Body, Spring Case, Diaphragm Plate, and Orifice: Aluminum Diaphragm, Disk, and O-ring: Nitrile (NBR) Adjusting Screw and Pushpost: Deldn® Closing Cap: ASA Thermoplastic (UV -Ray Resistant) Control Spring: Zinc -plated steel Machine Screw, Spring Seat, and Lever: Zinc -plated steel Valve Stem: Zinc Relief Valve Spring, Relief Spring Retainer, Lever Pin, and Vent Screen: Stainless steel t. Zuo � n Otis BG1M or any 20k=%e UM M amd UM Sft*l Oat no exceeded Dan* is a awk owned by E I. du Pont do Nmun and Co. In addition, Type R622 regulators have internal relief across the diaphragm to help minimize overpressure. Any outlet pressure above the start -to -discharge point of the non-adjustable relief valve spring moves the diaphragm off of the relief valve seat, allowing excess pressure to bleed out through the screened spring case vent. Table 11. Outlet Pressure Ranges Specifications The SpedficaWns sedw lists specifications for Type R622 Pressure Reducing Regulators. As it originally comes from the factory, specifications for a given regulator are stamped on the spring case nameplate. OUTLET PRESSURE RANGE CONTROL SPRING PART NUMBER CONTROL SPRING COLOR CODE SPRING WIRE DIAMETER INCHES (MM) SPRING FREE LENGTH. INCHES (nun) 1.8 to 2.24nches w.c. 0 to 5 mbar) T 1445370012 Puq to 0.051 0.30) 3.40 (86.4) 5 to 74ttches w.c (12 to 17 rnbar) T 143SBT0012 Orange 0.062 (1,58) 3.40 (86.4) 6.5 to 9-Inches w.c. (16 to 22 mbar) T 14399T00 t 2 Ye tow 0.067 (1,70) 3.61 (91.7) 9 to 13-i ctm w.c. (22 to 32 mbar) T 14400T0012 sliver 0.072 (1.63) 4.10 (104) 13 to 204nChes W.C. (32 to 50 Mbar) T 14401 T0012 Gray 0.080 (2.03) 3.60 (91.4) 16 to 35-plates w.c. (40 to 87 mbar) T 1440270012 Ptrtk 0.093 (236) 3.52 (89.4) 1 to 22 psig (69 to 152 mbar) Tt4403T0012 Ltgttl Blue 0105(2.67) 3.66 (93.0)