Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED FL Polyglass_2-3Ply_FlatRoof
2/3/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2fIZm6TpmvJBPDlAvtKGsHR4x0B30r8qfZppTJHg%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL16717-R10 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer POLYGLASS USA Address/Phone/Email 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1330 Ext 242 malpert@polyglass.com Authorized Signature Maury Alpert malpert@polyglass.com Technical Representative TECH REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (866) 802-8017 uspolyglasstechnical@polyglass.com Quality Assurance Representative QA REP Address/Phone/Email 1111 West Newport Center Drive Deerfield Beach, FL 33442 (888) 410-1375 uspolyglasstechnical@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/21/2022 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL16717_R10_COI_2020_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D2178 2015 ASTM D4601 2012 ASTM D4897 2009 ASTM D6162 2015 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 2/3/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obl%2fIZm6TpmvJBPDlAvtKGsHR4x0B30r8qfZppTJHg%3d%3d 2/2 ASTM D6509 2015 TAS 110 2000 TAS 114 2011 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/02/2020 Date Validated 10/04/2020 Date Pending FBC Approval 10/12/2020 Date Approved 12/16/2020 Summary of Products FL #Model, Number or Name Description 16717.1 Polyglass Modified Bitumen Roof Systems APP and SBS modified bitumen roof systems Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: +N/A/-622.5 Other: 1.) The design pressure in this application pertains to one system. Refer to ER Appendix for all systems and maximum design pressures. 2.) Refer to ER Section 5 for Limits of Use. 3.) Refer to FL1654 for non-HVHZ jurisdictions. Installation Instructions FL16717_R10_II_2020_10_01_FINAL_A1_ER_POLYGLASS_MODBIT_HVHZ_FL16717- R10.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL16717_R10_AE_2020_10_01_FINAL_ER_POLYGLASS_MB_HVHZ_FL16717-R10.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 83 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-12 1B Wood New, Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 12-14 1C Wood New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 14 1D Wood New, Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 15-17 1E Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-21 1F Wood New or Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 21-25 1G Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 25-32 2A Steel or Structural Concrete New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 33-35 2B Steel or Structural Concrete New, Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 36-40 2C Steel or Structural Concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 41-42 2D Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mech. Attached Velociflex, Bonded Roof Cover 43-44 3A Structural Concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 45-57 3B Structural Concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 58 4A Lightweight concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 59-63 4B Lightweight concrete New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 64 4C Lightweight concrete New or Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 65-68 5A Cementitious wood fiber Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 69-70 5B Cementitious wood fiber Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 70-71 5C Cementitious wood fiber Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 71 5D Cementitious wood fiber Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 72 5E Cementitious wood fiber Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 72 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 73-76 6B Existing gypsum New, Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 77 6C Existing gypsum New, Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 77 6D Existing gypsum New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 77 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 78-83 7B Various Recover F Non-Insulated, Bonded Roof Cover 83 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 2 of 83 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC HVHZ requirements to the satisfaction of the Authority Having Jurisdiction. Deck-attachment details pertain to ‘as-tested’ conditions under Testing Application Standard TAS 114, Appendix J. The table below provides reference to various as-tested deck sub-assemblies and associated maximum allowable design pressures. POLYGLASS AS-TESTED DECK ATTACHMENT DETAILS; TAS 114, APPENDIX J TYPE TESTED SPAN (FT O.C.) TESTED FASTENING TESTED FASTENER SPACING (INCH O.C.) HIGHEST AS-TESTED ALLOWABLE PRESSURE (PSF) 15/32-inch plywood 2 8d ring shank nails 6 -75.0 15/32-inch plywood 2 #10 wood screws 6 -90.0 15/32-inch plywood 2 #10 wood screws 4 -120.0 19/32-inch plywood 2 8d ring shank nails 6 -60.0 19/32-inch plywood 2 #10 wood screws 6 -127.5 22 ga., Type B, Grade 33 steel 6 Tek/5 screws 6 -112.5 22 ga., Type B, Grade 40 steel 6 5/8” puddle welds 6 -97.5 22 ga., Type B, Grade 40 steel 6 Traxx/5 screws with ¾” washers 6 -135.0 2 Unless otherwise noted, fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Firestone Insulation Fastening Plates with Firestone All-Purpose Fasteners; Firestone Pre-Assembled Fastener and Plate (consisting of 0.196-inch thread diameter fastener with 3-inch diameter metal plate). Minimum 1-inch plywood penetration or wood plank embedment. ➢ Steel Deck: Firestone Insulation Fastening Plates with Firestone All-Purpose Fasteners or Firestone Heavy-Duty Fasteners; Firestone Pre-Assembled Fastener and Plate (consisting of 0.196-inch thread diameter fastener with 3-inch diameter metal plate); Firestone Pre-Assembled Heavy-Duty Fastener and Plate (consisting of 0.275-inch thread diameter fastener with 3-inch diameter metal plate); AP AccuTrac; HD AccuTrac. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: Firestone Insulation Fastening Plates with Firestone Heavy-Duty Fasteners or Firestone Concrete Drive Fasteners; Firestone Pre-Assembled Heavy-Duty Fastener and Plate (consisting of 0.275-inch thread diameter fastener with 3-inch diameter metal plate); HD AccuTrac. Minimum 1-inch embedment into pilot hole in accordance with published installation instructions. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC HVHZ 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 If mechanical attachment to the structural deck through lightweight insulating concrete is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TA S 105 and Roofing Application Standard RAS 117 and/or RAS 137. Calculations shall be prepared, signed and sealed by a qualified design professional. 5 Preliminary insulation attachment for System Type D: Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer’s published instructions. ➢ Hot asphalt (HA): Full coverage at 25-30 lbs/square. ➢ DuPont INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ H.B. Fuller Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ H.B. Fuller Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive & Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 3 of 83 ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one -half the specified ribbons spacing. 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. ➢ H.B. Fuller Millennium One Step Foamable Adhesive (M-OSFA): MDP = -157.5 psf (Min. 0.5-inch thick) ➢ H.B. Fuller Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP = -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP = -45.0 psf (Min. 0.5-inch thick Multi-Max FA-3) ➢ OMG OlyBond 500 (OB500): MDP = -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (OB500): MDP = -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP = -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ ICP Adhesives & Sealants Polyset CR-20: MDP = -117.5 psf (Min. 1.0-inch thick) 8 Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9 For mechanically attached components, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC HVHZ 1620 or Roofing Application Standard RAS 128. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria in accordance with Roofing Application Standard RAS 117 or Roofing Application Standard RAS 137. *This extrapolation is not permitted for systems marked with an asterisk* 10 For assemblies marked with an asterisk*, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance in accordance with Testing Application Standard TAS 105. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Should the fastener resistance be less than that required, a revised fastener spacing – prepared, signed and sealed by a qualified design professional in accordance with Roofing Application Standard RAS 117 or Roofing Application Stan dard RAS 137 – may be submitted to the Building Official for review and acceptance. 12 Refer to FBC HVHZ 1521 for requirements and limitations regarding recover installations. For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with Testing Application Standard TAS 124. 13 For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC HVHZ Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC HVHZ 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC FBC HVHZ Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where spe cific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 83 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP-AA (Base and Ply sheets, Asphalt-Applied) Base Ply One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II Hot Asphalt at 20-40 lbs/square Ply One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes. SBS-CA1 Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield HT PG350 at 1.5-2.0 gal/square Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand-backed), Polyfresko G SBS FR (sand-backed) SBS-CA2 Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP Polyplus 35 at 1.5-2.0 gal/square Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand-backed), Polyfresko G SBS FR (sand-backed) SBS-AA (SBS, Asphalt-Applied) Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield HT Hot Asphalt at 20-40 lbs/square Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand-backed), Polyfresko G SBS FR (sand-backed) Note: Asphalt-applied sheets or insulation shall not be applied to poly-film surfaced membranes. SBS-TA (SBS, Torch-Applied) Base Ply or Ply One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield HT Torch-Applied Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (poly-film backed), Polyfresko G SBS FR (poly-film backed) SBS-SA-H (SBS, Self-Adhering, Hybrid Systems) Base Ply Elastobase SA Self-adhering (followed by torch-applied sheet) SBS-SA (SBS, Self-Adhering) Base Ply One or more plies Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR, Elastoflex SA Base HD Self-Adhering Cap Ply Elastoflex SA P, Elastoflex SA P FR, Polyreflect Note: Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, Elastobase (poly/sand) or Elastobase (poly/poly). APP-CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA (APP, Torch-Applied) Base Ply or Ply One or more plies Polyglass Base, Polyflex, Polybond Torch-Applied Cap Ply Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR APP-SA-H (APP, Self-Adhering, Hybrid Systems) Base Ply Polyflex SA Base Self-adhering (followed by torch-applied sheet) APP-SA (APP, Self-Adhering) Cap Ply Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polyfresko G SA FR, Polykool Self-Adhering Note: Unless otherwise noted, permissible membrane substrates for APP-SA are limited to the SBS-SA Base Ply options herein, Elastobase (poly/sand) or Elastobase (poly/poly). NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 5 of 83 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A: OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF)* TYPE (NOTE 15) APPLICATION C-VB-1. PG100 Elastoflex SA V Plus Self-Adhering D-IS or CR-20, 12-inch o.c. -60.0 C-VB-2. PG100 Polyglass Base Torch-applied D-IS or CR-20, 12-inch o.c. -75.0 C-VB-3. PG100 Elastoflex SA P Self-Adhering D-IS, 12-inch o.c. -75.0 C-VB-4. PG100 Elastoflex SA P Self-Adhering M-OSFA, 12-inch o.c. -157.5 C-VB-5. PG100 Elastoflex SA P Self-Adhering CR-20, 12-inch o.c. -270.0 C-VB-6. PG100 Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self-Adhering M-OSFA, M-PG-1, OB500 or CR-20, 12-inch o.c. -290.0 C-VB-7. PG100 SBS-TA (with sanded-top-surface) Torch-applied M-OSFA, M-PG-1, OB500 or CR-20, 12-inch o.c. -290.0 17 The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for application limitations and a Roofing Materials Directory for fire ratings associated with coating usage. SURFACING OPTIONS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS OPTION # SURFACING FLORIDA HVHZ PRODUCT APPROVAL SURF-1. PG 300 17-1031.01 SURF-2. PG 600 17-1031.01 SURF-3. PG 650 17-1031.01 SURF-4. PG 700 20-0611.01 SURF-5. PG 700 QS 20-0611.01 SURF-6. PG 800 17-1031.01 SURF-7. Polyplus 60 17-1031.01 SURF-8. Polyplus 65 17-1031.01 SURF-9. PolyBrite 60-FC 20-0611.01 SURF-10. PolyBrite 70 20-0611.01 SURF-11. PolyBrite 70 QS 20-0611.01 SURF-12. PolyBrite 75 20-0611.01 SURF-13. PolyBrite 71 HS 20-0611.01 SURF-14. PolyBrite 90 19-0610.02 SURF-15. PolyBrite 90.1 19-0610.02 SURF-16. PolyBrite 95 19-0610.02 SURF-17. PolyBrite 95.1 19-0610.02 SURF-18. KM Acryl 15 17-1031.01 SURF-19. KM Acryl 15 QS 17-1031.01 SURF-20. KM Acryl 25 17-1031.01 SURF-21. KM Acryl 25 QS 17-1031.01 SURF-22. KM Acryl 40 HS 17-1031.01 SURF-23. KM Acryl 85 17-1031.01 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 6 of 83 SURFACING OPTIONS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS OPTION # SURFACING FLORIDA HVHZ PRODUCT APPROVAL SURF-24. KM PS#250 17-1031.01 SURF-25. KM PS#220 17-1031.01 SURF-26. Turbo-Set 19-0820.05 18 “MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC (HVHZ) 1620 and Roofing Application Standard RAS 128 for determination of design wind loads. TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-1. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS- AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -45.0* W-2. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0* W-3. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS- AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -52.5 W-4. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 7 of 83 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-5. Min. 19/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top), Elastovent, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1-5/8- inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY- 3, Polytherm H, H- Shield, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS- AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -60.0 W-6. Min. 19/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top), Elastovent, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1-5/8- inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY- 3, Polytherm H, H- Shield, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-7. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap Fasteners 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS- AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -60.0 W-8. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap Fasteners 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-9. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) or Elastovent 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 8 of 83 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-10. Min. 15/32- inch plywood Polyglass G2 Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -82.5 W-11. Min. 15/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top) or Elastovent 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in five (5) equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -90.0 W-12. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -90.0 W-13. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) or Elastovent 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Min. 2-inch Polytherm, ACFoam II, III, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or ENRGY-3 D-IS, OB500, CR-20 or M- OSFA, atop fastener rows, 7-inch o.c. Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board D-IS, OB500, CR- 20 or M- OSFA BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0* SELF-ADHERING BASE PLY: W-14. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -45.0* W-15. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 9 of 83 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-16. Min. 19/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top), Elastovent, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1-5/8- inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY- 3, Polytherm H, H- Shield, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 W-17. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap Fasteners 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 W-18. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Min. 2-inch Polytherm, ACFoam II, III, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or ENRGY-3 D-IS, OB500, CR-20 or M- OSFA, atop fastener rows, 7-inch o.c. (Optional) Additional layers of base insulation D-IS, OB500, CR- 20 or M- OSFA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0* HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: W-19. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP- SA-H (Optional) APP-TA APP-TA -45.0* W-20. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP- SA-H (Optional) APP-TA APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 10 of 83 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-21. Min. 19/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top), Elastovent, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1-5/8- inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY- 3, Polytherm H, H- Shield, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP- SA-H (Optional) APP-TA APP-TA -60.0 W-22. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap Fasteners 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP- SA-H (Optional) APP-TA APP-TA -60.0 W-23. Min. 15/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top) or Elastovent 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt APP- SA-H (Optional) APP-TA APP-TA -67.5 W-24. Min. 15/32- inch plywood Polyglass G2 Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt APP- SA-H (Optional) APP-TA APP-TA -82.5 W-25. Min. 15/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top) or Elastovent 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in five (5) equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt APP- SA-H (Optional) APP-TA APP-TA -90.0 W-26. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board Hot asphalt APP- SA-H (Optional) APP-TA APP-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 11 of 83 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-27. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Min. 2-inch Polytherm, ACFoam II, III, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or ENRGY-3 D-IS, OB500, CR-20 or M- OSFA, atop fastener rows, 7-inch o.c. (Optional) Additional layers of base insulation D-IS, OB500, CR- 20 or M- OSFA APP- SA-H (Optional) APP-TA APP-TA -60.0* HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-28. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at min. 2-inch lap and 18- inch o.c. at two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -45.0* W-29. Min. 15/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap 9-inch o.c. at min. 2-inch lap and 12- inch o.c. at two, equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -52.5 W-30. Min. 19/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top), Elastovent, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1-5/8- inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch lap and 8- inch o.c. at three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY- 3, Polytherm H, H- Shield, H-Shield CG, Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -60.0 W-31. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) Simplex MAXX Cap Fasteners 12-inch o.c. at min. 4-inch lap and 12- inch o.c. at two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 12 of 83 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-32. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at min. 4-inch lap and 6- inch o.c. at four (4), equally spaced, staggered center rows Min. 2-inch Polytherm, ACFoam II, III, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or ENRGY-3 D-IS, OB500, CR-20 or M- OSFA, atop fastener rows, 7-inch o.c. (Optional) Additional layers of base insulation D-IS, OB500, CR- 20 or M- OSFA SBS-SA- H (Optional) SBS-TA SBS-TA -60.0* TABLE 1B: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-33. Min. 15/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top) or Elastovent Dekfast Hex (aka, Dekfast PLT-H- 2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 10-inch o.c. in 4- inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -52.5 W-34. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) or Elastovent OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA, APP-TA -60.0 W-35. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) or Elastovent OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 13 of 83 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-36. Min. 15/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top) or Elastovent Dekfast Hex (aka, Dekfast PLT-H- 2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -82.5 SELF-ADHERING BASE PLY: W-37. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) or Elastovent OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: W-38. Min. 15/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top) or Elastovent Dekfast Hex (aka, Dekfast PLT-H- 2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 10-inch o.c. in 4- inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-SA-H (Optional) APP-TA APP-TA -52.5 W-39. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) or Elastovent OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4- inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-SA-H (Optional) APP-TA APP-TA -60.0 W-40. Min. 15/32- inch plywood Polyglass G2 Base, Elastobase, Elastobase P (sanded-top) or Elastovent Dekfast Hex (aka, Dekfast PLT-H- 2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-SA-H (Optional) APP-TA APP-TA -82.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 14 of 83 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-41. Min. 19/32- inch plywood Elastobase, Elastobase P (sanded-top) or Elastovent OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. at min. 4-inch lap and 12- inch o.c. at two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch Polytherm, ACFoam II, ENRGY-3, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA-H (Optional) SBS-TA SBS-TA -60.0 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-42. Min. 19/32- inch plywood Min. 1.5-inch ENRGY 3, H-Shield or Polytherm Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #12 or Trufast 3” Metal Insulation Plate with Trufast DP 1 per 1.3 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-43. Min. 15/32- inch plywood Min. 2-inch Polytherm, ACFoam II, ENRGY-3, EnergyGuard Polyiso Insulation, H-Shield or Multi-Max FA3 Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), OMG #14 HD with OMG 3” Galvalume Steel Plates or Trufast #14 HD with Trufast 3- inch Insulation Plates 1 per 1.0 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt SBS-AA, SBS- TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -75.0 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: W-44. Min. 15/32- inch plywood Min. 2-inch Polytherm, ACFoam II, ENRGY-3, EnergyGuard Polyiso Insulation, H-Shield or Multi-Max FA3 Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), OMG #14 HD with OMG 3” Galvalume Steel Plates or Trufast #14 HD with Trufast 3- inch Insulation Plates 1 per 1.0 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum Fiber Roof Board Hot asphalt APP-SA-H (Optional) APP-TA APP-TA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 15 of 83 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-45. Min. 15/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), OMG #14 HD with OMG 3” Galvalume Steel Plates or Trufast #14 HD with Trufast 3-inch Insulation Plates 1 per 1.8 ft2 SBS-AA, SBS- TA, APP-TA (Optional) SBS- AA, SBS-TA, APP-TA SBS-AA, SBS- TA, APP-TA -45.0 W-46. Min. 15/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), OMG #14 HD with OMG 3” Galvalume Steel Plates or Trufast #14 HD with Trufast 3-inch Insulation Plates 1 per 1.0 ft2 SBS-AA, SBS- TA, APP-TA (Optional) SBS- AA, SBS-TA, APP-TA SBS-AA, SBS- TA, APP-TA -75.0 W-47. Min. 19/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP 1 per 1.3 ft2 (Optional if using AA Ply) BP-AA, SBS- AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -82.5 SELF-ADHERING BASE PLY: W-48. Min. 15/32- inch plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel 3” Round (aka, Dekfast PLT-R-3) or OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA None SBS-SA -45.0 W-49. Min. 15/32- inch plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA None SBS-SA -45.0 W-50. Min. 15/32- inch plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 with Polygrip Hex Plate or Dekfast DF-#14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 SBS-SA (Optional when using torch- applied Cap Ply) SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA or APP-TA -45.0 W-51. Min. 15/32- inch plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 SBS-SA (Optional when using torch- applied Cap Ply) SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA or APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 16 of 83 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply W-52. Min. 15/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), OMG #14 HD with OMG 3” Galvalume Steel Plates or Trufast #14 HD with Trufast 3-inch Insulation Plates 1 per 1.0 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP- TA -60.0 W-53. Min. 19/32- inch APA rated plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, H-Shield, H- Shield CG, ISO 95+ GL, Multi-Max FA3, Polytherm or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate 1 per 1.3 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -67.5* Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 180 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-54. Min. 19/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, H-Shield, H- Shield CG, ISO 95+ GL, Multi-Max FA3, Polytherm or Ultra-Max optionally primed with POLYBRITE 745 or WB3000ENRGY 3, H-Shield or Polytherm Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel 3” Round Insulation Plate (aka, Dekfast PLT-R-3) with Dekfast #12, OMG 3 in. Galvalume Plate (non-ribbed) or OMG AccuTrac Plate with #12 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast DPDekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP or Trufast 3” Metal Insulation Plate with Trufast DP 1 per 1.3 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -67.5* HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: W-55. Min. 15/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), OMG #14 HD with OMG 3” Galvalume Steel Plates or Trufast #14 HD with Trufast 3-inch Insulation Plates 1 per 1.8 ft2 APP-SA-H (Optional) APP- TA APP-TA -45.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-56. Min. 15/32- inch plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel 3” Round (aka, Dekfast PLT-R-3) or OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0 W-57. Min. 15/32- inch plywood One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 17 of 83 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply W-58. Min. 15/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), OMG #14 HD with OMG 3” Galvalume Steel Plates or Trufast #14 HD with Trufast 3-inch Insulation Plates 1 per 1.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -60.0 W-59. Min. 19/32” APA rated plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, H-Shield, H- Shield CG, ISO 95+ GL, Multi-Max FA3, Polytherm or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate* 1 per 1.3 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -67.5* W-60. Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 180 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance W-61. Min. 19/32- inch plywood (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, H-Shield, H- Shield CG, ISO 95+ GL, Multi-Max FA3, Polytherm or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel 3” Round Insulation Plate (aka, Dekfast PLT-R-3) with Dekfast #12, OMG 3 in. Galvalume Plate (non-ribbed) or OMG AccuTrac Plate with #12 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast DP 1 per 1.3 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -67.5* TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: W-62. Min. 19/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma- Ply 28 or GAFGLAS #75 OMG Flat Bottom Plates (square) with Roofgrip #14, Dekfast Hex (aka, Dekfast PLT-H- 2-7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 12-inch o.c. in 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA, APP-TA -52.5 W-63. Min. 19/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P or Elastovent OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA, APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 18 of 83 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply W-64. Min. 19/32-inch APA rated plywood One or more layers, any combination Loose-laid Elastobase, Elastobase P or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width- direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-AA, SBS-TA, APP- TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-65. Min. 19/32-inch APA rated plywood One or more layers, any combination Loose-laid Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width- direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-TA APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-66. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Polyglass G2 Base, Elastobase, Elastobase P or Elastovent Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 10-inch o.c. in 4-inch lap and 10- inch o.c. in three (3), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA, APP-TA -75.0 W-67. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Polyglass Base Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 10-inch o.c. in 4-inch lap and 10- inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP- TA APP-TA -75.0 W-68. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood One or more layers, any combination Loose-laid Elastobase, Elastobase P or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width- direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-AA, SBS-TA, APP- TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-69. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood One or more layers, any combination Loose-laid Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width- direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-TA APP-TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 19 of 83 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply W-70. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Polyglass G2 Base, Elastobase, Elastobase P or Elastovent Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 9-inch o.c. in 4-inch lap and 9- inch o.c. in four (4), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS- TA, APP-TA -90.0 W-71. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Polyglass Base Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 9-inch o.c. in 4-inch lap and 9- inch o.c. in four (4), equally spaced, staggered center rows (Optional) APP- TA APP-TA -90.0 W-72. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA -90.0 W-73. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA, APP-TA SBS-AA, SBS- TA or APP-TA -90.0 W-74. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Polyglass Base OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows (Optional) APP- TA APP-TA -90.0 W-75. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood One or more layers, any combination Loose-laid Elastobase, Elastobase P or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width- direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-AA, SBS-TA, APP- TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-76. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood One or more layers, any combination Loose-laid Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width- direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows APP-TA APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-77. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in five (5), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 20 of 83 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply W-78. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in five (5), equally spaced, staggered center rows (Optional) BP- AA, SBS-AA, SBS- TA, APP-TA SBS-AA, SBS- TA or APP-TA -120.0 W-79. Min. 15/32-inch plywood One or more layers, any combination Prelim. Attached Polyglass Base OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in five (5), equally spaced, staggered center rows (Optional) APP- TA APP-TA -120.0 SELF-ADHERING BASE PLY: W-80. Min. 19/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P (poly- film top) Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -52.5* W-81. Min. 19/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P (poly- film top) OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -60.0* W-82. Min. 19/32-inch APA rated plywood One or more layers, any combination Loose-laid Elastobase, Elastobase P (poly- film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width- direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA, APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: W-83. Min. 19/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P (poly- film top) Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows APP-SA-H APP-TA -52.5* W-84. Min. 19/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P (poly- film top) OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12- inch o.c. in two, equally spaced, staggered center rows APP-SA-H APP-TA -60.0* W-85. Min. 19/32-inch APA rated plywood One or more layers, any combination Loose-laid Elastobase, Elastobase P (poly- film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width- direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-SA-H APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-86. Min. 19/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P (poly- film top) Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-TA -52.5* NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 21 of 83 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply W-87. Min. 19/32-inch plywood One or more layers, any combination Prelim. Attached Elastobase, Elastobase P (poly- film top) OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0* W-88. Min. 19/32-inch APA rated plywood One or more layers, any combination Loose-laid Elastobase, Elastobase P (poly- film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width- direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA-H SBS-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply NO BASE PLY: W-89. Min. 15/32-inch plywood Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -45.0* W-90. Min. 15/32-inch plywood Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -52.5 W-91. Min. 15/32-inch (existing) or min. 19/32- inch (new) APA rated plywood Elastobase (sanded top) Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -60.0 W-92. Min. 15/32-inch (existing) or min. 19/32- inch (new) APA rated plywood Elastobase (poly-film top) Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows None SBS-TA, APP-TA -60.0 W-93. Min. 15/32-inch (existing) or min. 19/32- inch (new) APA rated plywood Polyglass Base Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows None APP-TA -60.0 W-94. Min. 15/32-inch (existing) or min. 19/32- inch (new) APA rated plywood Elastobase (poly-film top) Simplex MAXX Cap Note: MAXX Caps are to be primed with PG100 or ASTM D41 primer 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows None SBS-SA, APP-SA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 22 of 83 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply W-95. Min. 19/32-inch plywood Elastobase, Elastobase P, Elastovent,Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -60.0 W-96. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA, APP-SA -60.0 W-97. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P or Elastovent 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -67.5 W-98. Min. 15/32-inch plywood Polyglass Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows None APP-TA -67.5 W-99. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -75.0 W-100. Min. 15/32-inch plywood Polyglass Base Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows None APP-TA -75.0 W-101. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -90.0 W-102. Min. 15/32-inch plywood Polyglass Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows None APP-TA -90.0 W-103. Min. 15/32-inch plywood Elastobase, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -90.0 W-104. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. 4-inch o.c. in 4-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA, APP-SA -97.5 W-105. Min. 15/32-inch plywood Elastobase, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -105.0 W-106. Min. 19/32-inch plywood Elastobase, Elastobase P or Elastovent 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -112.5 W-107. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. Note: Tin caps are to be primed with PG100 or ASTM D41 primer. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA, APP-SA -112.5 ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 23 of 83 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply W-108. Min. 15/32-inch plywood Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -45.0* W-109. Min. 15/32-inch plywood Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -52.5 W-110. Min. 15/32-inch (existing) or min. 19/32- inch (new) APA rated plywood Elastobase (sanded top) Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -60.0 W-111. Min. 15/32-inch (existing) or min. 19/32- inch (new) APA rated plywood Elastobase (poly-film top) Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows SBS-TA SBS-TA, APP-TA -60.0 W-112. Min. 15/32-inch (existing) or min. 19/32- inch (new) APA rated plywood Polyglass Base Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows APP-TA APP-TA -60.0 W-113. Min. 19/32-inch plywood Elastobase, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -60.0 W-114. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P or Elastovent 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -67.5 W-115. Min. 15/32-inch plywood Polyglass Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in four (4), equally spaced, staggered center rows APP-TA APP-TA -67.5 W-116. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -75.0 W-117. Min. 15/32-inch plywood Polyglass Base Simplex MAXX Cap 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows APP-TA APP-TA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 24 of 83 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply W-118. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 W-119. Min. 15/32-inch plywood Polyglass Base Simplex MAXX Cap 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows APP-TA APP-TA -90.0 W-120. Min. 15/32-inch plywood Elastobase, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 W-121. Min. 15/32-inch plywood Elastobase, Elastobase P Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -105.0 W-122. Min. 19/32-inch plywood Elastobase, Elastobase P or Elastovent 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -112.5 SELF-ADHERING BASE PLY: W-123. Min. 15/32-inch (existing) or min. 19/32- inch (new) APA rated plywood Elastobase (poly-film top) Simplex MAXX Cap Note: MAXX Caps are to be primed with PG100 or ASTM D41 primer 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 W-124. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 W-125. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. 4-inch o.c. in 4-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -97.5 W-126. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. Note: Tin caps are to be primed with PG100 or ASTM D41 primer. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Elastoflex SA V Plus, Elastoflex SA V Plus FR SBS-SA, APP-SA, SBS-TA, APP-TA -112.5 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: W-127. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows APP-SA-H APP-TA -60.0 W-128. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. 4-inch o.c. in 4-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows APP-SA-H APP-TA -97.5 W-129. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. Note: Tin caps are to be primed with PG100 or ASTM D41 primer. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows APP-SA-H APP-TA -112.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 25 of 83 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-130. Min. 15/32” APA rated plywood Elastobase (poly-film top) Simplex MAXX Cap Note: MAXX Caps are to be primed with PG100 or ASTM D41 primer 8-inch o.c. at min. 3-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0 W-131. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 4-inch lap and 8-inch o.c. at three (3), equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0 W-132. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails. 4-inch o.c. at min. 4-inch lap and 4-inch o.c. at four (4), equally spaced, staggered center rows SBS-SA-H SBS-TA -97.5 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap NO BASE PLY: W-133. Min. 19/32-inch plywood Elastobase, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 OMG Flat Bottom Plates (square) with Roofgrip #14, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -52.5 W-134. Min. 19/32-inch plywood Elastobase, Elastobase P or Elastovent OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -60.0 W-135. Min. 19/32-inch APA rated plywood Elastobase, Elastobase P or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-136. Min. 19/32-inch APA rated plywood Elastobase, Elastobase P (poly-film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None SBS-SA, APP-SA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 26 of 83 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-137. Min. 19/32-inch APA rated plywood Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF) W-138. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P or Elastovent Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -75.0 W-139. Min. 15/32-inch plywood Polyglass Base Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows None APP-TA -75.0 W-140. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Elastobase, Elastobase P or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-141. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows None APP-TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-142. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P or Elastovent Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 27 of 83 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-143. Min. 15/32-inch plywood Polyglass Base Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows None APP-TA -90.0 W-144. Min. 15/32-inch plywood Elastobase, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA -90.0 W-145. Min. 15/32-inch plywood Elastobase, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA or APP-TA -90.0 W-146. Min. 15/32-inch plywood Polyglass Base OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None APP-TA -90.0 W-147. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Elastobase, Elastobase P or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows None SBS-AA, SBS-TA, APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-148. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows None APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-149. Min. 15/32-inch plywood Elastobase, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows None SBS-AA -120.0 W-150. Min. 15/32-inch plywood Elastobase, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows None SBS-AA, SBS-TA or APP-TA -120.0 W-151. Min. 15/32-inch plywood Polyglass Base OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows None APP-TA -120.0 ASPHALT-APPLIED OR TORCH-APPLIED BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 28 of 83 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-152. Min. 19/32-inch plywood Elastobase, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma-Ply 28 or GAFGLAS #75 OMG Flat Bottom Plates (square) with Roofgrip #14, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -52.5 W-153. Min. 19/32-inch plywood Elastobase, Elastobase P or Elastovent OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -60.0 W-154. Min. 19/32-inch APA rated plywood Elastobase, Elastobase P or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-155. Min. 19/32-inch APA rated plywood Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-TA APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-156. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P or Elastovent Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -75.0 W-157. Min. 15/32-inch plywood Polyglass Base Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 10-inch o.c. in 4-inch lap and 10-inch o.c. in three (3), equally spaced, staggered center rows APP-TA APP-TA -75.0 W-158. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Elastobase, Elastobase P or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 29 of 83 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-159. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 9-inch o.c. at min. 2-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-TA APP-TA -90.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 159 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-160. Min. 15/32-inch plywood Polyglass G2 Base, Elastobase, Elastobase P or Elastovent Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 W-161. Min. 15/32-inch plywood Polyglass Base Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Round Metal Plate with OMG HD, OMG Flat Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD. 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), equally spaced, staggered center rows APP-TA APP-TA -90.0 W-162. Min. 15/32-inch plywood Elastobase, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -90.0 W-163. Min. 15/32-inch plywood Elastobase, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty (min. 1-5/8-inch long) with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -90.0 W-164. Min. 15/32-inch plywood Polyglass Base OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows APP-TA APP-TA -90.0 W-165. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Elastobase, Elastobase P or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 30 of 83 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-166. Min. 15/32-inch (existing) or min. 19/32-inch (new) APA rated plywood Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at three (3), equally spaced, staggered center rows APP-TA APP-TA -105.0 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 103 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-167. Min. 15/32-inch plywood Elastobase, Elastobase P or Elastovent Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -120.0 W-168. Min. 15/32-inch plywood Elastobase, Elastobase P or Elastovent OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-AA, SBS-TA, APP-TA -120.0 W-169. Min. 15/32-inch plywood Polyglass Base OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3” Round Metal Plates or OMG Flat Bottom Metal Plates 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), equally spaced, staggered center rows APP-TA APP-TA -120.0 W-170. Min. 19/32-inch APA rated plywood Elastobase (sanded top) or Elastovent Trufast Versa Fasteners (min. ¾” penetration) & Plates; 1 screws per plate in center hole* 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows BP-AA, SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance W-171. Min. 19/32-inch APA rated plywood Elastobase (poly-film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 1 screws per plate in center hole* 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows SBS-TA SBS-TA, APP-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance W-172. Min. 19/32-inch APA rated plywood Polyglass Base Trufast Versa Fasteners (min. ¾” penetration) & Plates; 1 screws per plate in center hole* 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows APP-TA APP-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance SELF-ADHERING BASE PLY: W-173. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -52.5* W-174. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0* NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 31 of 83 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap W-175. Min. 19/32-inch APA rated plywood Elastobase, Elastobase P (poly-film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-176. Min. 19/32-inch APA rated plywood Elastobase (poly-film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 1 screws per plate in center hole* Note: Versa-Fast Plates shall be primed with PG100 or ASTM D41 primer. 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows SBS-SA SBS-SA, APP-SA, SBS-TA, APP-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: W-177. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows APP-SA-H APP-TA -52.5* W-178. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows APP-SA-H APP-TA -60.0* W-179. Min. 19/32-inch APA rated plywood Elastobase, Elastobase P (poly-film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows APP-SA-H APP-TA -67.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: W-180. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA-H SBS-TA -52.5* W-181. Min. 19/32-inch plywood Elastobase, Elastobase P (poly-film top) OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0* W-182. Min. 19/32-inch APA rated plywood Elastobase, Elastobase P (poly-film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 2 screws per plate installed 180° into the holes of the plate, parallel to the width-direction of the sheet* 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two (2), equally spaced, staggered center rows SBS-SA-H SBS-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 32 of 83 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 199 lbf. Additional Versa -Fast Fasteners within each Versa-Fast Plate may be utilized to produce Minimum Characteristic Resistance Force (MCRF). W-183. Min. 19/32-inch APA rated plywood Elastobase (poly-film top) Trufast Versa Fasteners (min. ¾” penetration) & Plates; 1 screws per plate in center hole* Note: Versa-Fast Plates shall be primed with PG100 or ASTM D41 primer. 9-inch o.c. at min. 4-inch lap and 9-inch o.c. at four (4), equally spaced center rows SBS-SA-H SBS-TA -127.5 Note: *For re-roof or recover construction, field withdrawal resistance testing (Note 11) shall yield MCRF > 141 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 33 of 83 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: SC-1. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H- Shield or Polytherm Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #14 HD or OMG 3-inch Galv Plate with OMD HD 1 per 2.0 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* SC-2. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, H- Shield or Polytherm Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #14 HD or OMG 3-inch Galv Plate with OMD HD 1 per 4.0 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* SC-3. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch ENRGY 3, H-Shield or Polytherm Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.3 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -90.0 SC-4. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch ENRGY 3, H-Shield or Polytherm Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14 or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.3 ft2 Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS- AA (Top surface primed with PG100 primer) SBS-SA, SBS-TA or APP-TA SBS-SA, APP-SA, SBS-TA or APP-TA -90.0 SC-5. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch DensDeck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum- Fiber Roof Board D-IS SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 SC-6. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch DensDeck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum- Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA or M-PG1 SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 34 of 83 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-7. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch DensDeck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum- Fiber Roof Board OB500 SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 SC-8. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-AA, SBS-TA, APP-TA (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -45.0 SELF-ADHERING BASE PLY: SC-9. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board PRIMER: POLYBRITE 745 or WB3000 D-IS SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-10. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5- inch SECUROCK Cement Roof Board PRIMER: POLYBRITE 745 or WB3000 M-OSFA or M-PG1 SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-11. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board PRIMER: POLYBRITE 745 or WB3000 OB500 SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 35 of 83 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SC-12. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board PRIMER: POLYBRITE 745 or WB3000 CR-20 SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0 COLD-APPLIED BASE PLY: SC-13. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board D-IS SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-14. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5- inch SECUROCK Cement Roof Board M-OSFA or M-PG1 SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-15. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0 SC-16. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete Min. 2-inch Polytherm, ACFoam II, ENRGY 3, EnergyGuard Polyiso Insulation, Polytherm H, H-Shield or Multi-Max FA3 Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #14, OMG 3” Galvalume Ribbons Plates with OMG #14 Roofgrip or Trufast 3” Metal Insulation Plate with Trufast #14 HD 1 per 1.6 ft2 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 36 of 83 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: SC-17. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.75-inch JM Fesco Board (homogeneous) or min. 1.5-inch JM Fesco Board (laminated) OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 2.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -45.0* SC-18. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 4.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -45.0* SC-19. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 4.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -45.0* SC-20. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 2-inch H-Shield WF OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 4.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -45.0* SC-21. Min. 22 ga., type B, Grade 40 steel; 6 ft span; 5/8” puddle welds, 6” o.c. One or more layers, any combination, min. 1.5” thick, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Dekfast PLT-H-2-7/8 or PTL-R-3 plates with Dekfast DF-#12-PH3, DF- #14-PH3 or DF-#15-PH3 fasteners or OMG 3 in. Galvalume Steel Plate, 3 in. Ribbed Galvalume Plate (Flat) or AccuTrac Flat Bottom Plate with OMG #12 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip fasteners or Trufast 3” Metal Insulation Plate with Trufast #12 DP, Trufast #14 HD or Trufast #15 EHD fasteners 1 per 2.0 ft2 SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -52.5 SC-22. Min. 22 ga., type B, Grade 40 steel; 6 ft span; 5/8” puddle welds, 6” o.c. One or more layers, any combination, min. 1.5” thick, loose laid Min. 0.25-inch DensDeck Prime Dekfast PLT-H-2-7/8 or PTL-R-3 plates with Dekfast DF-#12-PH3, DF- #14-PH3 or DF-#15-PH3 fasteners or OMG 3 in. Galvalume Steel Plate, 3 in. Ribbed Galvalume Plate (Flat) or AccuTrac Flat Bottom Plate with OMG #12 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip fasteners or Trufast 3” Metal Insulation Plate with Trufast #12 DP, Trufast #14 HD or Trufast #15 EHD fasteners 1 per 2.0 ft2 SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -60.0 SC-23. Min. 22 ga., type B, Grade 40 steel; 6 ft span; 5/8” puddle welds, 6” o.c. One or more layers, any combination, min. 1.5” thick, loose laid Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Dekfast PLT-H-2-7/8 or PTL-R-3 plates with Dekfast DF-#12-PH3, DF- #14-PH3 or DF-#15-PH3 fasteners or OMG 3 in. Galvalume Steel Plate, 3 in. Ribbed Galvalume Plate (Flat) or AccuTrac Flat Bottom Plate with OMG #12 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip fasteners or Trufast 3” Metal Insulation Plate with Trufast #12 DP, Trufast #14 HD or Trufast #15 EHD fasteners 1 per 1.6 ft2 SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 37 of 83 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SC-24. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OMG 3-inch Galvalume Steel Plate with OMG #14 HD 1 per 1.8 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -75.0 SC-25. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 (steel only) or #14 or Trufast 3” Metal Insulation Plate with Trufast DP (steel only) or HD 1 per 1.3 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS-TA, APP-TA -82.5 SELF-ADHERING BASE PLY: SC-26. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch H-Shield or Polytherm OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 2.0 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -45.0* SC-27. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, OMG 3” Galvalume Ribbed Plates with OMG #14 RoofGrip or Trufast 3” Metal Insulation Plates with Trufast #14 HD Fasteners 1 per 2.0 ft2 SBS-SA None SBS-CA1, SBS-CA2, APP-CA1 -45.0* SC-28. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 2.0 ft2 SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP-SA, SBS-TA or APP- TA -45.0* SC-29. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel 3” Round (aka, Dekfast PLT-R-3) or OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA None SBS-SA -45.0 SC-30. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA None SBS-SA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 38 of 83 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SC-31. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- #14 or DF-#15 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 SBS-SA (Optional when using torch- applied Cap Ply) SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA or APP- TA -45.0 SC-32. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 SBS-SA (Optional when using torch- applied Cap Ply) SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA or APP- TA -45.0 SC-33. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch H-Shield or Polytherm Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast #14 1 per 2.0 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -60.0 SC-34. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 1.6 ft2 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -60.0 SC-35. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, H-Shield, H- Shield CG, ISO 95+ GL, Multi-Max FA3, Polytherm or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel 3” Round Insulation Plate (aka, Dekfast PLT-R-3) with Dekfast #12 (steel only) or Dekfast #14, OMG 3 in. Galvalume Plate (non-ribbed) or OMG AccuTrac Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty or Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 1.3 ft2 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5* SC-36. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 1.3 ft2 SBS-SA (Optional) SBS- TA or APP-TA SBS-TA or APP- TA -72.5 SC-37. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OMG 3-inch Galvalume Steel Plate with OMG #14 HD 1 per 1.8 ft2 SBS-SA (Optional) SBS- TA SBS-TA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 39 of 83 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SC-38. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- #14 or DF-#15 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -90.0 SC-39. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- #14 or DF-#15 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA (Optional) SBS- TA, APP-TA SBS-TA, APP-TA -97.5 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: SC-40. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch H-Shield or Polytherm OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 2.0 ft2 APP-SA-H (Optional) APP- TA APP-TA -45.0* HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: SC-41. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch H-Shield or Polytherm H OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0* SC-42. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel 3” Round (aka, Dekfast PLT-R-3) or OMG #14 Roofgrip with OMG 3 in. Round Metal Plate, OMG 3 in. Ribbed Galvalume Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0 SC-43. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -45.0 SC-44. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch H-Shield or Polytherm optionally primed with POLYBRITE 745 or WB3000 Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel only) or Dekfast #14 1 per 2.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -60.0 SC-45. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 1.6 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 40 of 83 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply SC-46. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, ENRGY 3 CGF, H-Shield, H- Shield CG, ISO 95+ GL, Multi-Max FA3, Polytherm or Ultra-Max optionally primed with POLYBRITE 745 or WB3000 Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Galvalume Steel 3” Round Insulation Plate (aka, Dekfast PLT-R-3) with Dekfast #12 (steel only) or Dekfast #14, OMG 3 in. Galvalume Plate (non-ribbed) or OMG AccuTrac Plate with #12 Roofgrip (steel only) or OMG #14 Heavy Duty or Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 1.3 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -67.5* SC-47. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 OMG 3 in. Galvalume Plate (non-ribbed) with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex (aka, Dekfast PLT-H-2- 7/8) with Dekfast #12 DP (steel only) or Dekfast #14, Trufast 3” Metal Insulation Plate with Trufast #12 DP (steel only) or Trufast #14 HD 1 per 1.3 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -72.5 SC-48. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OMG 3-inch Galvalume Steel Plate with OMG #14 HD 1 per 1.8 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -75.0 SC-49. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- #14 or DF-#15 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -90.0 SC-50. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination, min. 1-inch, loose laid Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF- #14 or DF-#15 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 SBS-SA-H (Optional) SBS- TA SBS-TA -97.5 COLD-APPLIED BASE PLY: SC-51. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board Dekfast Galvalume Steel Hex with Dekfast #14, OMG 3” Galvalume Ribbed Plates with OMG #14 RoofGrip or Trufast 3” Metal Insulation Plates with Trufast #14 HD Fasteners 1 per 2.0 ft2 SBS-CA1, SBS-CA2 (Optional) SBS- CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 41 of 83 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: SC-52. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase, Elastobase P, Elastovent or JM Perma-Ply 28 Roofgrip #14 with OMG Flat Bottom Plates (square), Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 18-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -45.0* SC-53. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase, Elastobase P, Elastovent, Polyglass G2 Base, CertainTeed Glasbase, Firestone MB Base, JM Perma- Ply 28 or GAFGLAS #75 Roofgrip #14 with OMG Flat Bottom Plates (square), Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -52.5 SC-54. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase, Elastobase P or Elastovent Roofgrip #12 (steel only) or #14 with OMG Flat Bottom Plates (square) 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -60.0 SC-55. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Polybond, Polyflex Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG Roofgrip #14 OMG Flat Bottom Plates 12-inch o.c. at the 4-inch lap and 18-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -112.5 SELF-ADHERING BASE PLY: SC-56. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase or Elastobase P with poly top surface Roofgrip #14 with OMG Flat Bottom Plates (square), Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -52.5* SC-57. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase or Elastobase P with poly top surface Roofgrip #12 (steel only) or #14 with OMG Flat Bottom Plates (square) 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -60.0* HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: SC-58. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase or Elastobase P with poly top surface Roofgrip #14 with OMG Flat Bottom Plates (square), Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows APP-SA-H APP-TA -52.5* NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 42 of 83 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply SC-59. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase or Elastobase P with poly top surface Roofgrip #12 (steel only) or #14 with OMG Flat Bottom Plates (square) 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows APP-SA-H APP-TA -60.0* HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: SC-60. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase or Elastobase P with poly top surface Roofgrip #14 with OMG Flat Bottom Plates (square), Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-TA -52.5* SC-61. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastobase or Elastobase P with poly top surface Roofgrip #12 (steel only) or #14 with OMG Flat Bottom Plates (square) 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0* COLD-APPLIED BASE PLY: SC-62. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose laid Elastobase Trufast #12 DP (steel only), #14 HD or #15 EHD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 12-inch o.c. at one staggered center row (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -45.0* SC-63. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose laid Elastovent Trufast #12 DP (steel only), #14 HD or #15 EHD with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at one staggered center row (Optional) SBS-CA1 SBS-CA1, APP- CA1 -45.0* SC-64. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose laid Elastobase Trufast #12 DP (steel only), #14 HD or #15 EHD with Trufast 3” Metal Insulation Plate 12-inch o.c. at 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -67.5 SC-65. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose laid Elastovent Trufast #12 DP (steel only), #14 HD or #15 EHD with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) SBS-CA1 SBS-CA1, APP- CA1 -67.5 SC-66. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose- laid Elastoflex S6 Trufast #12 DP (steel only) or Trufast #14 HD (steel or concrete) with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 4-inch lap and 6-inch o.c. at one staggered center row (Optional) Elastoflex S6 applied in PG350 at 1.5-2.0 gal/square SBS-CA1 -75.0* SC-67. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Loose- laid Elastoflex S6 Trufast #12 DP (steel only) or Trufast #14 HD (steel or concrete) with Trufast 3” Metal Insulation Plate 12-inch o.c. at min. 4-inch lap and 12-inch o.c. at two, equally spaced, staggered center rows (Optional) Elastoflex S6 applied in PG350 at 1.5-2.0 gal/square SBS-CA1 -90.0* NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 43 of 83 TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED VELOCIFLEX, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: SC-68. Min. 22 ga., type B, 33 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plates or Trufast 2.75” Barbed Metal Seam Plates 12-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA -45.0 SC-69. Min. 22 ga., type B, 33 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.75” Barbed Metal Seam Plates 6-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA -60.0 SC-70. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.75” Barbed Metal Seam Plates 18-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -60.0 SC-71. Min. 22 ga., type B, 33 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.75” Barbed Metal Seam Plates 12-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -82.5 SC-72. Min. 22 ga., type B, 33 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoshield HT Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Barbed Metal Seam Plates, Trufast 2.4” Scoop Seam Plates or Trufast 2.75” Barbed Metal Seam Plates or Dekfast #15 with Dekfast Galvalume Steel 1-1/2” x 2-3/4” Oval Barbed Plate (aka, Dekfast PLT-O2- 3/4-12B) or Dekfast Galvalume Steel 2-3/8” Round Barbed Plate (aka, Dekfast PLT-R-2-3/8-6B) 12-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -82.5 SC-73. Min. 22 ga., type B, Grade 80 steel One or more layers, any combination Prelim. Attached Polyflex Dekfast #15 HS with Dekfast Galvalume Steel 2-3/8” Round Barbed Plate (aka, Dekfast PLT-R-2-3/8-6B) 12-inch o.c. within the 5-inch wide, torch-sealed side lap (Optional) APP-TA SBS-TA, APP- TA -82.5 SC-74. Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Polybond or Polyflex Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4 in. Barbed Seam Plates 12-inch o.c. within the 6-inch wide, torch-sealed side lap (Optional) APP-TA SBS-TA, APP- TA -82.5 SC-75. Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoshield HT Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Barbed Metal Seam Plates, Trufast 2.4” Scoop Seam Plates or Trufast 2.75” Barbed Metal Seam Plates or Dekfast #15 with Dekfast Galvalume Steel 1-1/2” x 2-3/4” Oval Barbed Plate (aka, Dekfast PLT-O2- 3/4-12B) or Dekfast Galvalume Steel 2-3/8” Round Barbed Plate (aka, Dekfast PLT-R-2-3/8-6B) 6-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 44 of 83 TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED VELOCIFLEX, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply SC-76. Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.75” Barbed Metal Seam Plates 6-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) SBS-TA SBS-TA (D6164 only) -135.0 COLD-APPLIED BASE PLY: SC-77. Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.75” Barbed Metal Seam Plates 18-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) Elastoflex S6 applied in PG350 at 1.5- 2.0 gal/square SBS-CA1 -60.0 Note: When extrapolating base sheet attachment for this system for elevated pressure zones, any additional fastener rows installed in the center of the sheet shall be stripped-in with minimum 6-inch wide strips of torch-applied, sand-top-surfaced, Polyglass SBS modified bitumen membrane prior to placement of subsequent Base Ply or Cap Ply membranes in PG350 adhesive. SC-78. Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structural concrete One or more layers, any combination Prelim. Attached Elastoflex S6 HP Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.75” Barbed Metal Seam Plates 12-inch o.c. within the 5-inch wide, torch-sealed or heat- welded side laps (Optional) Elastoflex S6 applied in PG350 at 1.5- 2.0 gal/square SBS-CA1 -82.5 Note: When extrapolating base sheet attachment for this system for elevated pressure zones, any additional fastener rows installed in the center of the sheet shall be stripped-in with minimum 6-inch wide strips of torch-applied, sand-top-surfaced, Polyglass SBS modified bitumen membrane prior to placement of subsequent Base Ply or Cap Ply membranes in PG350 adhesive. NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 45 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT OR TORCH APPLIED BASE PLY: C-1 Structural concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 C-2 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-3 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board D-IS SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-4 Structural concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 C-5 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-6 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board OB500 SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-7 Structural concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA or M-PG1 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 C-8 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield M-OSFA or M-PG1 Min. 0.25-inch Dens Deck Prime M-OSFA or M-PG1 SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-9 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board M-OSFA or M-PG1 SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-10 Structural concrete None Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H- Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 46 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-11 Structural concrete None Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H- Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-TA (Optional) APP-TA APP-TA -232.5 C-12 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-13 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board CR-20 SBS-TA, APP- TA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-14 Structural concrete None (Optional) Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield OB Classic (full- coverage) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB Classic (full- coverage) BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 C-15 Structural concrete None (Optional) Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield OB Classic (full- coverage) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB Classic (full- coverage) APP-TA (Optional) APP-TA APP-TA -232.5 C-16 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS-AA SBS-AA -225.0 C-17 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -232.5 C-18 Structural concrete PG100 Min. 0.75-inch Fesco Board (homogeneous) Hot asphalt None N/A (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -277.5 C-19 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt Min. 0.75-inch Fesco Board (homogeneous) Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -290.0 C-20 Structural concrete PG100 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt None N/A (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -285.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 47 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-21 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -480.0 C-22 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck Prime Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -480.0 C-23 Structural concrete PG100 Min. 0.25-inch Dens Deck Prime Hot asphalt None N/A (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -510.0 SELF-ADHERING BASE PLY TO INSULATION: C-24 Structural concrete (Optiona l) PG100 Min. 1.5-inch H-Shield or Multi-Max FA3 D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5 C-25 Structural concrete None Min. 1.5-inch Polytherm H, H-Shield D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -122.5 C-26 Structural concrete (Optiona l) PG100 Min. 1.5-inch Polytherm, ACFoam II or ENRGY 3 D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -135.0 C-27 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 (Optional) additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -120.0 C-28 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -122.5 C-29 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -127.5 C-30 Structural concrete None Min. 1.5-inch Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -150.0 C-31 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H- Shield M-OSFA or M-PG1 (Optional) additional layers(s) of base insulation M-OSFA or M-PG1 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -122.5 C-32 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation M-OSFA SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -232.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 48 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-33 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax. M-OSFA or M-PG1 (Optional) additional layers(s) of base insulation, optionally primed with POLYBRITE 745 or WB3000 M-OSFA or M-PG1 SBS-SA None SBS-CA1, SBS- CA2 -290.0 C-34 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, Polytherm H, H-Shield CR-20 (Optional) additional layers(s) of base insulation CR-20 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -122.5 C-35 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -240.0 C-36 Structural concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield OB Classic (full- coverage) (Optional) additional layers(s) of base insulation OB Classic (full- coverage) SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -270.0 C-37 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt (Optional) additional layers(s) of base insulation Hot asphalt SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -480.0 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY TO INSULATION: C-38 Structural concrete (Optiona l) PG100 Min. 1.5-inch H-Shield or Multi-Max FA3 D-IS (Optional) additional layers(s) of base insulation D-IS APP-SA-H (Optional) APP-TA APP-TA -67.5 C-39 Structural concrete None Min. 1.5-inch Polytherm H, H-Shield D-IS (Optional) additional layers(s) of base insulation D-IS APP-SA-H (Optional) APP-TA APP-TA -122.5 C-40 Structural concrete (Optiona l) PG100 Min. 1.5-inch Polytherm, ACFoam II or ENRGY 3 D-IS (Optional) additional layers(s) of base insulation D-IS APP-SA-H (Optional) APP-TA APP-TA -135.0 C-41 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II OB500 (Optional) additional layers(s) of base insulation OB500 APP-SA-H (Optional) APP-TA APP-TA -122.5 C-42 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional layers(s) of base insulation OB500 APP-SA-H (Optional) APP-TA APP-TA -127.5 C-43 Structural concrete None Min. 1.5-inch Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base insulation OB500 APP-SA-H (Optional) APP-TA APP-TA -150.0 C-44 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H- Shield M-OSFA or M-PG1 (Optional) additional layers(s) of base insulation M-OSFA or M-PG1 APP-SA-H (Optional) APP-TA APP-TA -122.5 C-45 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation M-OSFA APP-SA-H (Optional) APP-TA APP-TA -232.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 49 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-46 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, Polytherm H, H-Shield CR-20 (Optional) additional layers(s) of base insulation CR-20 APP-SA-H (Optional) APP-TA APP-TA -122.5 C-47 Structural concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield OB Classic (full- coverage) (Optional) additional layers(s) of base insulation OB Classic (full- coverage) APP-SA-H (Optional) APP-TA APP-TA -270.0 C-48 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt (Optional) additional layers(s) of base insulation Hot asphalt APP-SA-H (Optional) APP-TA APP-TA -480.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY TO INSULATION: C-49 Structural concrete (Optiona l) PG100 Min. 1.5-inch H-Shield or Multi-Max FA3 D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -67.5 C-50 Structural concrete None Min. 1.5-inch Polytherm H, H-Shield D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 C-51 Structural concrete (Optiona l) PG100 Min. 1.5-inch Polytherm, ACFoam II or ENRGY 3 D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -135.0 C-52 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 C-53 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -127.5 C-54 Structural concrete None Min. 1.5-inch Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -150.0 C-55 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H- Shield M-OSFA or M-PG1 (Optional) additional layers(s) of base insulation M-OSFA or M-PG1 SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 C-56 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -232.5 C-57 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, Polytherm H, H-Shield CR-20 (Optional) additional layers(s) of base insulation CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 C-58 Structural concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield OB Classic (full- coverage) (Optional) additional layers(s) of base insulation OB Classic (full- coverage) SBS-SA-H (Optional) SBS-TA SBS-TA -270.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 50 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-59 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt (Optional) additional layers(s) of base insulation Hot asphalt SBS-SA-H (Optional) SBS-TA SBS-TA -480.0 SELF-ADHERING BASE PLY TO COVERBOARD: C-60 Structural concrete None Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum- Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5 C-61 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam, Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 C-62 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime D-IS SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -120.0 C-63 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 D-IS SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-64 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch DEXcell FA Glass Mat Roof Board D-IS SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-65 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 D-IS SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -322.5 C-66 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or ISO 95+GL OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 C-67 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -127.5 C-68 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, H- Shield or ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -150.0 C-69 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 51 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-70 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch DEXcell FA Glass Mat Roof Board OB500 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-71 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 OB500 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -322.5 C-72 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 C-73 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -232.5 C-74 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield M-OSFA or M-PG1 Min. 0.25-inch Dens Deck Prime M-OSFA or M-PG1 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-75 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield M-OSFA or M-PG1 Min. 0.25-inch DEXcell FA Glass Mat Roof Board M-OSFA or M-PG1 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-76 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 M-OSFA or M-PG1 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -322.5 C-77 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 2-inch Polytherm, ACFoam II, min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 C-78 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime CR-20 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 52 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-79 Structural concrete None Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H- Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -240.0 C-80 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -282.5 C-81 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch or DEXcell FA Glass Mat Roof Board CR-20 SBS-SA (Optional) SBS-TA, APP- TA SBS-TA, APP-TA -322.5 C-82 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 CR-20 SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -322.5 C-83 Structural concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield OB Classic (full- coverage) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB Classic (full- coverage) SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -350.0 C-84 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-SA, SBS- TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -350.0 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY TO COVERBOARD: C-85 Structural concrete None Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS APP-SA-H (Optional) APP-TA APP-TA -67.5 C-86 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime D-IS APP-SA-H (Optional) APP-TA APP-TA -120.0 C-87 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 or DEXcell FA Glass Mat Roof Board D-IS APP-SA-H (Optional) APP-TA APP-TA -322.5 C-88 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 APP-SA-H (Optional) APP-TA APP-TA -127.5 C-89 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, H- Shield or ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 APP-SA-H (Optional) APP-TA APP-TA -150.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 53 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-90 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board OB500 APP-SA-H (Optional) APP-TA APP-TA -322.5 C-91 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board M-OSFA or M-PG1 APP-SA-H (Optional) APP-TA APP-TA -322.5 C-92 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime CR-20 APP-SA-H (Optional) APP-TA APP-TA -240.0 C-93 Structural concrete None Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H- Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-SA-H (Optional) APP-TA APP-TA -240.0 C-94 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board CR-20 APP-SA-H (Optional) APP-TA APP-TA -322.5 C-95 Structural concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield OB Classic (full- coverage) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB Classic (full- coverage) APP-SA-H (Optional) APP-TA APP-TA -350.0 C-96 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-SA-H (Optional) APP-TA APP-TA -350.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY TO COVERBOARD: C-97 Structural concrete None Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum- Fiber Roof Board D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -67.5 C-98 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 54 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-99 Structural concrete None Min. 2-inch Polytherm, ACFoam II, ENRGY- 3, Polytherm H or H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 C-100 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch Dens Deck Prime optionally primed with POLYBRITE 745 or WB3000 D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 C-101 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board optionally primed with POLYBRITE 745 or WB3000 or DEXcell FA Glass Mat Roof Board D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 C-102 Structural concrete None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -127.5 C-103 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, H- Shield or ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -150.0 C-104 Structural concrete None Min. 2-inch Polytherm, ACFoam II, ENRGY- 3, Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 C-105 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 C-106 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 C-107 Structural concrete None Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -232.5 C-108 Structural concrete None Min. 2-inch Polytherm, ACFoam II, ENRGY- 3, Polytherm H or H-Shield M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 C-109 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield M-OSFA or M-PG1 Min. 0.25-inch Dens Deck Prime M-OSFA or M-PG1 SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 C-110 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield M-OSFA or M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board M-OSFA or M-PG1 SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 55 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-111 Structural concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 C-112 Structural concrete None Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H- Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 C-113 Structural concrete None Min. 2-inch Polytherm, ACFoam II, ENRGY- 3, Polytherm H or H-Shield CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 C-114 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 C-115 Structural concrete None (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H, H-Shield CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DEXcell FA Glass Mat Roof Board CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 C-116 Structural concrete None Min. 2-inch Polytherm, ACFoam II, Polytherm H or H-Shield OB Classic (full- coverage) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB Classic (full- coverage) SBS-SA-H (Optional) SBS-TA SBS-TA -350.0 C-117 Structural concrete PG100 Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 Hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA-H (Optional) SBS-TA SBS-TA -350.0 COLD-APPLIED BASE PLY: C-118 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H or H-Shield D-IS Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board D-IS SBS-CA1, SBS- CA2 (Optional) SBS-CA1, SBS- CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 C-119 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H or H-Shield D-IS Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board D-IS SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 56 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-120 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, Polytherm H or H-Shield D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-121 Structural concrete None Min. 1-inch ENRGY 3, Polytherm H or H- Shield D-IS Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum- Fiber Roof Board D-IS SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2 -232.5 C-122 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA, M- PG1 Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum- Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16- inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA or M-PG1 SBS-CA1, SBS- CA2 (Optional) SBS-CA1, SBS- CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 C-123 Structural concrete None Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA, M- PG1 Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board, min. 7/16- inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA, M- PG1 SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-124 Structural concrete None Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA, M- PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M- PG1 SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-125 Structural concrete None Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA, M- PG1 Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum- Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16- inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA, M- PG1 SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2 -232.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 57 of 83 TABLE 3A: STRUCTURAL CONCRETE DECKS; MIN. 2,500 PSI – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 16 FOR VAPOR BARRIER OPTIONS System No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-126 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS- CA2 (Optional) SBS-CA1, SBS- CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 C-127 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board OB500 SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-128 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-129 Structural concrete None Min. 1-inch Polytherm, ACFoam II, ENRGY 3 or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2 -232.5 C-130 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum- Fiber Roof Board CR-20 SBS-CA1, SBS- CA2 (Optional) SBS-CA1, SBS- CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 C-131 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board CR-20 SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-132 Structural concrete None Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 C-133 Structural concrete None Min. 1-inch ENRGY 3, Polytherm H, H- Shield, Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum- Fiber Roof Board CR-20 SBS-CA1, SBS- CA2 None SBS-CA1, SBS- CA2 -232.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 58 of 83 TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) *MDP (psf) Base Ply Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: C-134 Structural concrete PG100 (Optional) SBS-TA (Optional) SBS-TA SBS-TA -495.0 C-135 Structural concrete PG100 BP-AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -622.5 SELF-ADHERING BASE PLY: C-136 Structural concrete PG100 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -315.0 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: C-137 Structural concrete PG100 APP-SA-H (Optional) APP-TA APP-TA -315.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: C-138 Structural concrete PG100 SBS-SA-H (Optional) SBS-TA SBS-TA -315.0 COLD-APPLIED BASE PLY: C-139 Structural concrete None SBS-CA1 None SBS-CA1, SBS-CA2, APP-CA1 -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 59 of 83 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CELCORE (NOA 13-0307.02): ASPHALT OR TORCH APPLIED BASE PLY: LWC-1 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA, SBS- AA, APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -222.5 SELF-ADHERING BASE PLY: LWC-2 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS- SA SBS-SA, APP- SA -222.5 LWC-3 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -222.5 LWC-4 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -222.5 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: LWC-5 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 APP-SA-H (Optional) APP- TA APP-TA -222.5 LWC-6 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-SA-H (Optional) APP- TA APP-TA -222.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-7 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA-H (Optional) SBS- TA SBS-TA -222.5 LWC-8 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS- TA SBS-TA -222.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 60 of 83 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ELASTIZELL (NOA 18-0208.03): ASPHALT OR TORCH APPLIED BASE PLY: LWC-9 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, ISO 95+ GL, Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -225.0 LWC-10 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA, SBS- AA, APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -180.0 SELF-ADHERING BASE PLY: LWC-11 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 (Optional) Additional layers of base insulation OB500 SBS-SA (Optional) SBS- SA SBS-SA, APP- SA -120.0 LWC-12 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -120.0 LWC-13 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, ISO 95+ GL, Polytherm H or H-Shield OB500 (Optional) Additional layers of base insulation OB500 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -225.0 LWC-14 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, ISO 95+ GL, Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -225.0 LWC-15 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS- SA SBS-SA, APP- SA -180.0 LWC-16 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 61 of 83 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-17 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -180.0 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: LWC-18 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 APP-SA-H (Optional) APP- TA APP-TA -120.0 LWC-19 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, ISO 95+ GL, Polytherm H or H-Shield OB500 (Optional) Additional layers of base insulation OB500 APP-SA-H (Optional) APP- TA APP-TA -225.0 LWC-20 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, ISO 95+ GL, Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 APP-SA-H (Optional) APP- TA APP-TA -225.0 LWC-21 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 APP-SA-H (Optional) APP- TA APP-TA -180.0 LWC-22 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-SA-H (Optional) APP- TA APP-TA -180.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-23 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS- TA SBS-TA -120.0 LWC-24 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, ISO 95+ GL, Polytherm H or H-Shield OB500 (Optional) Additional layers of base insulation OB500 SBS-SA-H (Optional) SBS- TA SBS-TA -225.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 62 of 83 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-25 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, ISO 95+ GL, Polytherm H or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS- TA SBS-TA -225.0 LWC-26 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA-H (Optional) SBS- TA SBS-TA -180.0 LWC-27 Structural concrete Min. 200 psi, min 2-inch Range II Elastizell Lightweight Insulating Concrete. Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS- TA SBS-TA -180.0 MEARLCRETE (NOA 13-1007.09): ASPHALT OR TORCH APPLIED BASE PLY: LWC-28 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA, SBS- AA, APP-TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -222.5 SELF-ADHERING BASE PLY: LWC-29 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS- SA SBS-SA, APP- SA -222.5 LWC-30 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -222.5 LWC-31 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -222.5 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: LWC-32 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 APP-SA-H (Optional) APP- TA APP-TA -222.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 63 of 83 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-33 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-SA-H (Optional) APP- TA APP-TA -222.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-34 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 CR-20 (Optional) Additional layers of base insulation CR-20 SBS-SA-H (Optional) SBS- TA SBS-TA -222.5 LWC-35 Structural concrete Min. 200 psi, min. 2-inch Mearlcrete Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, ISO 95+ GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS- TA SBS-TA -222.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 64 of 83 TABLE 4B: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. ‡Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply LWC-36 Min. 22 ga., Type B, vented steel at max. 5 ft spans Min. 300 psi, min. 2-inch Celcore Cellular Concrete, Elastizell Lightweight Insulating Concrete or Mearlcrete GAFGLAS #75 or Elastovent OMG CR BSF 7-inch o.c. at 4-inch lap and 7-inch o.c. in two, equally spaced center rows (Optional) Min. 1.5-inch Polytherm, ACFoam II, Polytherm H, H- Shield, Multi- Max FA3 or Polytherm HA Min. 1.5-inch Thermaroof Composite, Polytherm Composite, or min. 0.5- inch Structodek High Density Fiberboard Roof Insulation or min. 0.75- inch Fesco Board (homogeneous) HA (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0 LWC-37 Min. 22 ga., Type B, vented steel at max. 5 ft spans Min. 300 psi, min. 2-inch Celcore Cellular Concrete, Elastizell Lightweight Insulating Concrete or Mearlcrete GAFGLAS #75 or Elastovent OMG CR BSF 7-inch o.c. at 4-inch lap and 7-inch o.c. in two, equally spaced center rows Min. 1.5-inch Polytherm, ACFoam II, Polytherm H, H- Shield, Multi- Max FA3 or Polytherm HA None N/A SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -45.0 LWC-38 Min. 22 ga., Type B, vented steel at max. 5 ft spans Min. 300 psi, min. 2-inch Celcore Cellular Concrete, Elastizell Lightweight Insulating Concrete or Mearlcrete GAFGLAS #75 or Elastovent OMG CR BSF 7-inch o.c. at 4-inch lap and 7-inch o.c. in two, equally spaced center rows Min. 1.5-inch Polytherm, ACFoam II, Polytherm H, H- Shield, Multi- Max FA3 or Polytherm HA None N/A APP-SA-H (Optional) APP-TA APP-TA -45.0 LWC-39 Min. 22 ga., Type B, vented steel at max. 5 ft spans Min. 300 psi, min. 2-inch Celcore Cellular Concrete, Elastizell Lightweight Insulating Concrete or Mearlcrete GAFGLAS #75 or Elastovent OMG CR BSF 7-inch o.c. at min. 4-inch lap and 7- inch o.c. at two, equally spaced center rows Min. 1.5-inch Polytherm, ACFoam II, Polytherm H, H- Shield, Multi- Max FA3 or Polytherm HA None N/A SBS-SA-H (Optional) SBS-TA SBS-TA -45.0 ‡ NOTE: For steel deck application where specific deck attachment is not referenced, tested attachment was 5/8” puddle welds with weld-washers or Tek/5 screws spaced 6” o.c. NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 65 of 83 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. ‡Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply PRE-EXISTENT CELLULAR LIGHTWEIGHT INSULATING CONCRETE: LWC-40 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick pre- existent cellular LWC. Note: To qualify the LWIC under this assembly, an OMG CR BPF shall achieve an average withdrawal of 53 lbf when tested per TAS 105 or ANSI/SPRI FX-1 B3 or B11 OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet (Optional) BP-AA, SBS- AA SBS-AA, APP- TA -45.0 CELCORE (NOA 13-0307.02): ASPHALT OR TORCH APPLIED BASE PLY: LWC-41 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Celcore B1 through B11 Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA SBS-AA -45.0 LWC-42 Min. 26 ga., type HF steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B1, B2, B3, B4, B7, B8, B10 or B11 OMG CR BPF 9-inch o.c. in a 3-inch lap and 9-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA SBS-AA -45.0 LWC-43 Min. 22 ga., type B steel at max 6 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B1, B2, B3, B4, B7, B8, B10 or B11 OMG CR BPF 7-inch o.c. in a 3-inch lap and 14-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA SBS-AA -45.0 LWC-44 Min. 22 ga., type B steel at max 6 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B1, B2, B3, B4, B7, B8, B10 or B11 OMG CR BPF 9-inch o.c. in a 3-inch lap and 9-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA SBS-AA -45.0 LWC-45 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B1, B2 or B11 Trufast Twin Loc-Nail 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA, or APP- TA -45.0 LWC-46 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF B2 or B11 Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three equally spaced, staggered center rows BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA, or APP- TA -60.0 LWC-47 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF B2 (with poly- film top surface) Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three equally spaced, staggered center rows SBS-TA or APP-TA SBS-TA or APP-TA -60.0 LWC-48 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore B1 through B11 Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA, SBS-TA, APP-TA SBS-AA, APP- TA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 66 of 83 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. ‡Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-49 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Elastobase P Trufast FM- 290 10-inch o.c. in a 4-inch lap and 10-inch o.c. in three equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -90.0 SELF-ADHERING BASE PLY: LWC-50 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B2 (with poly- film top surface) Trufast Twin Loc-Nail 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -45.0 LWC-51 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF B2 (with poly- film top surface) Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three equally spaced, staggered center rows SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -60.0 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: LWC-52 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF B2 (with poly- film top surface) Trufast Twin Loc-Nail 9-inch o.c. in a 4-inch lap and 18-inch o.c. in two, equally spaced, staggered rows in the field of the sheet APP-SA-H APP-TA -45.0 LWC-53 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF B2 (with poly- film top surface) Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three equally spaced, staggered center rows APP-SA-H APP-TA -60.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-54 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 225 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture B2 (with poly- film top surface) Trufast Twin Loc-Nail 9-inch o.c. at a min. 4-inch lap and 18-inch o.c. at two, equally spaced, staggered rows in the field of the sheet SBS-SA-H SBS-TA -45.0 LWC-55 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture B2 (with poly- film top surface) Trufast FM-90 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. at three equally spaced, staggered center rows SBS-SA-H SBS-TA -60.0 ELASTIZELL (NOA 18-0208.03): ASPHALT OR TORCH APPLIED BASE PLY: LWC-56 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II B1 through B11 Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA, SBS-TA, or APP-TA SBS-AA, SBS- TA, or APP- TA -45.0 LWC-57 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II B2 (with poly- film top surface) Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-TA or APP-TA SBS-TA or APP-TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 67 of 83 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. ‡Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-58 Min. 22 ga., type B vented steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 Elastobase P (with poly-film top surface) Trufast FM- 290 8-inch o.c. in a 4-inch lap and 8-inch o.c. in three, equally spaced, staggered rows in the field of the sheet (Optional) BP-AA, SBS- AA, SBS-TA, or APP-TA SBS-AA, SBS- TA, or APP- TA -52.5 LWC-59 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 B2 or B11 Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, equally spaced, staggered rows in the field of the sheet BP-AA or SBS-AA SBS-AA, SBS- TA, SBS-SA, APP-TA or APP-SA -60.0 LWC-60 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 B2 (with poly- film top surface) Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, equally spaced, staggered rows in the field of the sheet SBS-TA or APP-TA SBS-TA or APP-TA -60.0 SELF-ADHERING BASE PLY: LWC-61 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II B2 (with poly- film top surface) Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -45.0 LWC-62 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 B2 (with poly- film top surface) Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -60.0 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: LWC-63 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Elastizell Range II B2 (with poly- film top surface) Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 3-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet APP-SA-H APP-TA -45.0 LWC-64 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 B2 (with poly- film top surface) Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. in a 4-inch lap and 6-inch o.c. in three, equally spaced, staggered rows in the field of the sheet APP-SA-H APP-TA -60.0 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 68 of 83 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. ‡Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet (Note A below) Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply LWC-65 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 200 psi, min. 2-inch thick Range II Elastizell Lightweight Insulating Concrete B2 (with poly- film top surface) Trufast FM-90 or OMG CR BPF 7-inch o.c. at a min. 3-inch lap and 7-inch o.c. at two, equally spaced, staggered rows in the field of the sheet SBS-SA-H SBS-TA -45.0 LWC-66 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 350 psi, min. 2-inch thick Elastizell with Zell-Crete Fibers, supplemental attached with Roofgrip #21 and 3-inch plates at 1 per 8 ft2 B2 (with poly- film top surface) Trufast Twin Loc-Nails (min. 1.8-inch) 6-inch o.c. at a min. 4-inch lap and 6-inch o.c. at three, equally spaced, staggered rows in the field of the sheet SBS-SA-H SBS-TA -60.0 MEARLCRETE (NOA 13-1007.09): ASPHALT OR TORCH APPLIED BASE PLY: LWC-67 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete B1, B2, B3, B7 or B11 Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet BP-AA, SBS- AA, SBS-TA, or APP-TA SBS-AA, SBS- TA, or APP- TA -52.5 LWC-68 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete B2 (with poly- film top surface) Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-TA or APP-TA SBS-TA or APP-TA -52.5 SELF-ADHERING BASE PLY: LWC-69 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete B2 (with poly- film top surface) Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet SBS-SA SBS-SA, APP- SA, SBS-TA or APP-TA -52.5 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: LWC-70 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete B2 (with poly- film top surface) Trufast FM-90 or OMG CR BPF 7-inch o.c. in a 4-inch lap and 7-inch o.c. in two, equally spaced, staggered rows in the field of the sheet APP-SA-H APP-TA -52.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: LWC-71 Min. 22 ga., type B steel at max 5 ft spans or structural concrete Min. 300 psi, min. 2-inch thick Mearlcrete B2 (with poly- film top surface) Trufast FM-90 or OMG CR BPF 7-inch o.c. at a min. 4-inch lap and 7-inch o.c. at two, equally spaced, staggered rows in the field of the sheet SBS-SA-H SBS-TA -52.5 ‡ NOTE: For steel deck application where specific deck attachment is not referenced, tested attachment was 5/8” puddle welds with weld-washers or Tek/5 screws spaced 6” o.c. See Note 1. A. Base Sheets options in Table 4C are coded as follows: ➢ B1: Polyglass G2 Base; B2: Elastobase or Elastobase P; B3: GAFGLAS #75; B4: GAFGLAS Stratavent Nailable Venting Base Sheet; B5: GAFGLAS Ply 4; B6: GAFGLAS FlexPly 6; B7: JM Perma Ply No. 28; B8: JM Vensulation; B9: JM GlasPly IV; B10: JM GlasPly Premier; B11: Elastovent NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 69 of 83 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT OR TORCH APPLIED BASE PLY: CWF-1 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 D-IS or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation D-IS or OB500 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -45.0 CWF-2 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 D-IS or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 SBS-TA or APP- TA (Optional) SBS- TA or APP-TA SBS-TA, APP- TA -45.0 CWF-3 Existing Min. 2-inch Tectum Plank or Tectum LS Plank; 2 ft span; three (3) evenly spaced #15 screws with 2” diameter plates per joist Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation CR-20 BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA, APP-TA -52.5 CWF-4 Existing Min. 2-inch Tectum Plank or Tectum LS Plank; 2 ft span; three (3) evenly spaced #15 screws with 2” diameter plates per joist Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-TA or APP- TA (Optional) SBS- TA or APP-TA SBS-TA, APP- TA -52.5 SELF-ADHERING BASE PLY: CWF-5 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 D-IS or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -45.0 CWF-6 Existing Min. 2-inch Tectum Plank or Tectum LS Plank; 2 ft span; three (3) evenly spaced #15 screws with 2” diameter plates per joist Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS- SA, SBS-TA or APP-TA SBS-SA, APP- SA, SBS-TA, APP-TA -52.5 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: CWF-7 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 D-IS or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 APP-SA- H (Optional) APP- TA APP-TA -45.0 CWF-8 Existing Min. 2-inch Tectum Plank or Tectum LS Plank; 2 ft span; three (3) evenly spaced #15 screws with 2” diameter plates per joist Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board CR-20 APP-SA- H (Optional) APP- TA APP-TA -52.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 70 of 83 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-9 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 D-IS or OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board D-IS or OB500 SBS-SA- H (Optional) SBS- TA SBS-TA -45.0 CWF-10 Existing Min. 2-inch Tectum Plank or Tectum LS Plank; 2 ft span; three (3) evenly spaced #15 screws with 2” diameter plates per joist Min. 1.5-inch Polytherm, ACFoam II, ISO 95+GL, Polytherm H, H-Shield, ENRGY-3 CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA- H (Optional) SBS- TA SBS-TA -52.5 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT OR TORCH APPLIED BASE PLY: CWF-11 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase, Elastobase P, Elastovent or Polyglass G2 Base Trufast Twin Loc-Nail 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ISO95+GL, Polytherm H, H-Shield, ENRGY 3 or Multi-Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board, Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5- inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS- AA, SBS-TA, APP-TA -45.0* CWF-12 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase, Elastobase P, Elastovent or Polyglass G2 Base Trufast Twin Loc-Nail 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ISO95+GL, Polytherm H, H-Shield, ENRGY 3 or Multi-Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-TA or APP- TA (Optional) SBS-TA, SBS-SA or APP-TA SBS-TA, SBS-SA, APP- TA, APP-SA -45.0* SELF-ADHERING BASE PLY: CWF-13 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase, Elastobase P, Elastovent or Polyglass G2 Base Trufast Twin Loc-Nail 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ISO95+GL, Polytherm H, H-Shield, ENRGY 3 or Multi-Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA (Optional) SBS-TA, SBS-SA or APP-TA SBS-TA, SBS-SA, APP- TA, APP-SA -45.0* HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 71 of 83 TABLE 5B: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-14 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase, Elastobase P, Elastovent or Polyglass G2 Base Trufast Twin Loc-Nail 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ISO95+GL, Polytherm H, H-Shield, ENRGY 3 or Multi-Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt APP-SA- H (Optional) APP-TA APP-TA -45.0* HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: CWF-15 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase, Elastobase P, Elastovent or Polyglass G2 Base Trufast Twin Loc-Nail 9-inch o.c. at min. 4- inch lap and 18-inch o.c. at two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ISO95+GL, Polytherm H, H-Shield, ENRGY 3 or Multi-Max FA3, Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Hot asphalt SBS-SA- H (Optional) SBS-TA SBS-TA -45.0* TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CWF-16 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Min. 2-inch H- Shield or Polytherm H OMG Polymer GypTec Plate with Polymer GypTec or Trufast TL 3 in. Plate with TL Fastener 1 per 4.0 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 72 of 83 TABLE 5D: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply CWF-17 Existing Min. 2.5- inch Tectum Plank or Tectum LS Plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5- inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc- Nails (min. 1-inch embedment) 1 per 2.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* TABLE 5E: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply CWF-18 Existing Min. 2.5-inch Tectum Plank or Tectum LS Plank Elastobase, Elastobase P, Polyglass G2 Base Trufast Twin Loc-Nails 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 73 of 83 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT- OR TORCH-APPLIED BASE PLY: G-1 Existing, sound poured gypsum or gypsum plank deck Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board CR-20 None N/A (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -245.0 SELF-ADHERING BASE PLY: G-2 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 G-3 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch min. 2.0 pcf, Insulfoam OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -112.5 G-4 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -112.5 G-5 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -112.5 G-6 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 G-7 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation and/or min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -202.5 G-8 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch, min. 2.0 pcf Insulfoam, Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 74 of 83 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-9 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA -240.0 G-10 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -240.0 G-11 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H- Shield CG or Multi-Max FA3 CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -257.5 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: G-12 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base insulation OB500 APP-SA-H (Optional) APP-TA APP-TA -112.5 G-13 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 APP-SA-H (Optional) APP-TA APP-TA -112.5 G-14 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation and/or min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board M-OSFA APP-SA-H (Optional) APP-TA APP-TA -202.5 G-15 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board CR-20 APP-SA-H (Optional) APP-TA APP-TA -240.0 G-16 Existing, sound poured gypsum or gypsum plank deck Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H- Shield CG or Multi-Max FA3 CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-SA-H (Optional) APP-TA APP-TA -257.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: G-17 Existing, sound poured gypsum or gypsum plank Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 G-18 Existing, sound poured gypsum or gypsum plank Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -112.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 75 of 83 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-19 Existing, sound poured gypsum or gypsum plank Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -112.5 G-20 Existing, sound poured gypsum or gypsum plank Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 G-21 Existing, sound poured gypsum or gypsum plank Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H- Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation and/or min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -202.5 G-22 Existing, sound poured gypsum or gypsum plank Min. 1.5-inch, min. 2.0 pcf EPS insulation board, Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H-Shield CG or Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 G-23 Existing, sound poured gypsum or gypsum plank Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 G-24 Existing, sound poured gypsum or gypsum plank Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield, H- Shield CG or Multi-Max FA3 CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -257.5 COLD APPLIED BASE PLY: G-25 Existing, sound poured gypsum or gypsum plank deck Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -120.0 G-26 Existing, sound poured gypsum or gypsum plank deck Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA SBS-CA1 None SBS-CA1, SBS-CA2, APP-CA1 -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 76 of 83 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-27 Existing, sound poured gypsum or gypsum plank deck Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board M-OSFA SBS-CA1, SBS-CA2 None SBS-CA1, SBS-CA2, APP-CA1 -127.5 G-28 Existing, sound poured gypsum or gypsum plank deck Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA SBS-CA1, SBS-CA2 None SBS-CA1, SBS-CA2 -202.5 G-29 Existing, sound poured gypsum or gypsum plank deck Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -112.5 G-30 Existing, sound poured gypsum or gypsum plank deck Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS-CA2, APP-CA1 -120.0 G-31 Existing, sound poured gypsum or gypsum plank deck Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board CR-20 SBS-CA1 None SBS-CA1, SBS-CA2, APP-CA1 -127.5 G-32 Existing, sound poured gypsum or gypsum plank deck Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 CR-20 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board CR-20 SBS-CA1, SBS-CA2 None SBS-CA1, SBS-CA2, APP-CA1 -127.5 G-33 Existing, sound poured gypsum or gypsum plank deck Min. 1-inch ENRGY 3, Polytherm H, H-Shield, Multi- Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS-CA2 None SBS-CA1, SBS-CA2 -232.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 77 of 83 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-34 Existing, sound poured gypsum or gypsum plank deck Elastobase, Elastobase P, Elastovent or Polyglass G2 Base Trufast FM-75 or FM-90 or Twin Loc-Nails 9-inch o.c. in 4- inch lap and 18- inch o.c. in two, equally spaced, staggered center rows Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ISO95+GL, Polytherm H, H-Shield, ENRGY 3, Polytherm or Multi-Max FA3 Hot asphalt Min. 0.25-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum- Fiber Roof Board, Min. 0.75-inch Fesco Board (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Hot asphalt BP-AA, SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer (Note 13) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply G-35 Existing sound poured gypsum or gypsum plank deck (Optional) One or more layers, any combination, loose laid Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5- inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc- Nails (min. 1-inch embedment) 1 per 2.0 ft2 (Optional if using AA Ply) BP-AA, SBS-AA (Optional if using AA Base) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Cap Ply G-36 Existing sound poured gypsum or gypsum plank deck Elastobase, Elastobase P, Elastovent or Polyglass G2 Base Trufast FM-75 or FM- 90 or Twin Loc-Nails 9-inch o.c. in 4-inch lap and 18-inch o.c. in two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 78 of 83 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply ASPHALT OR TORCH APPLIED BASE PLY: R-1 Existing asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board D-IS BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -67.5 R-2 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II or ENRGY 3 or min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board D-IS BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA, or APP-TA -90.0 R-3 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or ISO 95+GL OB500 Min. 0.25-inch Dens Deck, Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA, or APP-TA -127.5 R-4 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA BP-AA, SBS- AA, SBS-TA, APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA, or APP-TA -157.5 R-5 Existing asphaltic roof Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 BP-AA, SBS- AA (Optional) BP-AA, SBS- AA SBS-AA -225.0 R-6 Existing asphaltic roof Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 or min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-TA (Optional) APP-TA APP-TA -232.5 SELF-ADHERING BASE PLY: R-7 Existing asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck Prime D-IS SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -67.5 R-8 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3 or Multi-Max FA3 or min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 R-9 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS (Optional) additional layers(s) of base insulation D-IS SBS-SA (Optional) SBS-SA SBS-SA -90.0 R-10 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 79 of 83 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-11 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II or ENRGY 3 D-IS (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -90.0 R-12 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield or min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 R-13 Existing asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 (Optional) additional layers of base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-14 Existing asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -120.0 R-15 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -127.5 R-16 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 R-17 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -157.5 R-18 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam, Min. 2-inch Polytherm, ACFoam II, min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -72.5 R-19 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers(s) of base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA -240.0 R-20 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -240.0 R-21 Existing asphaltic roof (Optional if Top Layer Insulation installed) Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0- inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 CR-20 (Optional if Base Layer Insulation installed) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 80 of 83 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-22 Existing asphaltic roof (Optional if Top Layer Insulation installed) Min. 2-inch Polytherm, ACFoam II, ENRGY-3, Polytherm H or H- Shield CR-20 (Optional if Base Layer Insulation installed) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -247.5 HYBRID SYSTEMS WITH SELF-ADHERING APP BASE PLY: R-23 Existing asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck Prime D-IS APP-SA-H (Optional) APP-TA APP-TA -67.5 R-24 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS APP-SA-H (Optional) APP-TA APP-TA -90.0 R-25 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II or ENRGY 3 D-IS (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS APP-SA-H (Optional) APP-TA APP-TA -90.0 R-26 Existing asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 APP-SA-H (Optional) APP-TA APP-TA -120.0 R-27 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 APP-SA-H (Optional) APP-TA APP-TA -127.5 R-28 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA APP-SA-H (Optional) APP-TA APP-TA -157.5 R-29 Existing asphaltic roof Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-SA-H (Optional) APP-TA APP-TA -240.0 R-30 Existing asphaltic roof Min. 2-inch Polytherm, ACFoam II, ENRGY-3, Polytherm H or H-Shield CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 APP-SA-H (Optional) APP-TA APP-TA -247.5 HYBRID SYSTEMS WITH SELF-ADHERING SBS BASE PLY: R-31 Existing asphaltic roof Min. 1.5-inch Multi-Max FA3 D-IS (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or Dens Deck Prime D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 81 of 83 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-32 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3 or Multi-Max FA3 or min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch Dens Deck Prime D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 R-33 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -90.0 R-34 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II or ENRGY 3 D-IS (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -90.0 R-35 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield or min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch Dens Deck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 R-36 Existing asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -120.0 R-37 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Polytherm H or H-Shield OB500 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -127.5 R-38 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA Min. 0.25-inch Dens Deck Prime M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 R-39 Existing asphaltic roof Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H-Shield or Multi-Max FA3 M-OSFA (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -157.5 R-40 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam, Min. 2-inch Polytherm, ACFoam II, min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 CR-20 Min. 0.25-inch Dens Deck Prime CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 R-41 Existing asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 R-42 Existing asphaltic roof Min. 1.5-inch Ultra-Max or Multi-Max FA-3, min. 1.3-inch Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 82 of 83 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-43 Existing asphaltic roof Min. 2-inch Polytherm, ACFoam II, ENRGY-3, Polytherm H or H-Shield CR-20 (Optional) additional layers(s) of base insulation and/or min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 COLD APPLIED BASE PLY: R-44 Existing asphaltic roof (Optional) Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H or H-Shield D-IS Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board D-IS SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -90.0 R-45 Existing asphaltic roof (Optional) Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA, M-PG1 Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA or M-PG1 SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 R-46 Existing asphaltic roof (Optional) Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA, M-PG1 Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA, M- PG1 SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-47 Existing asphaltic roof (Optional) Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA, M-PG1 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board M-OSFA, M- PG1 SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-48 Existing asphaltic roof (Optional) Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Polyiso Insulation, ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, Multi-Max FA3, RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA M-OSFA, M-PG1 Min. 0.25-inch Dens Deck, Dens Deck Prime, DEXcell FA Glass Mat Roof Board, SECUROCK Gypsum-Fiber Roof Board or SECUROCK Glass-Mat Roof Board, min. 7/16-inch DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board M-OSFA, M- PG1 SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2 -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report P40690.12.13-1-R11 for FL16717-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION Revision 11: 10/01/2020 ©2018, NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 83 of 83 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) *MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-49 Existing asphaltic roof (Optional) Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime, DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 R-50 Existing asphaltic roof (Optional) Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 OB500 Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board OB500 SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-51 Existing asphaltic roof (Optional) Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-52 Existing asphaltic roof (Optional) Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS-CA2 (Optional) SBS-CA1, SBS-CA2 SBS-CA1, SBS- CA2, APP-CA1 -120.0 R-53 Existing asphaltic roof (Optional) Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or DEXcell FA Glass Mat Roof Board CR-20 SBS-CA1 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-54 Existing asphaltic roof (Optional) Min. 1-inch Polytherm, ACFoam II, Polytherm G, ACFoam III, ENRGY 3, Polytherm H, H-Shield or Multi-Max FA3 CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2, APP-CA1 -127.5 R-55 Existing asphaltic roof (Optional) Min. 1-inch ENRGY 3, Polytherm H, H-Shield, Multi-Max FA3 CR-20 Min. 0.25-inch Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board CR-20 SBS-CA1, SBS-CA2 None SBS-CA1, SBS- CA2 -232.5 TABLE 7B: RECOVER APPLICATIONS SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply R-56 Existing fully-adhered, granule- surfaced modified bitumen None Polyflex, torch-applied (Optional) Polyflex, torch-applied APP-TA -362.5 R-57 Existing fully-adhered, granule- surfaced modified bitumen PG100 Polyflex, torch-applied (Optional) Polyflex, torch-applied APP-TA -445.0