HomeMy WebLinkAboutEnergy Calcs - KleinEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 410/20/2020 10:01 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
Quick Calcs, Inc.
Klein Residence
Klein Residence
Street:
City, State, Zip: Palm City , FL , 34990
12772 NW Mariner Circle
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
544
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 114.14 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Raised Floor
b. N/A
c. N/A
R=19.0 544.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Frame - Wood, Exterior R=19.0 1047.00 ft²
b. N/A R=f t ²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=20.0 544.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 40 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:1.583 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits CF, Pstat
0
(114.1 sqft.)
(1047.0 sqft.)
(544.0 sqft.)
(544.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
18.8 SEER:16.00
Efficiency
k B t u / h r Efficiency
17.0 COP:1.00
f t ² R
6 60
EF: 0.950
Glass/Floor Area: 0.210
Total Proposed Modified Loads:
Total Baseline Loads:
25.14
27.78 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
10-20-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie County
Quick Calcs, Inc.
1
Klein Residence
Klein Residence
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
544
0
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34990
Palm City ,
St. Lucie
12772 NW Mariner Circl
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 544 4842
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 Bath 54 432 No 1 Yes Yes1 Yes
2 Master Sitting 308 2772 No 5 Yes Yes1 Yes
3 Storage 16 144 No 0 Yes Yes1 Yes
4 Elevator 25 225 No 1 Yes Yes1 No
5 Stairwell 141 1269 No 1 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 54 ft² 1 0 0______ 19Raised Floor 19 - - - - - - - -Bath
2 308 ft² 1 0 0______ 19Raised Floor 19 - - - - - - - -Master Sitting
3 16 ft² 1 0 0______ 19Raised Floor 19 - - - - - - - -Storage
4 25 ft² 1 0 0______ 19Raised Floor 19 - - - - - - - -Elevator
5 141 ft² 1 0 0______ 19Raised Floor 19 - - - - - - - -Stairwell
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Flat tile/slate 561 ft² Medium 0.6 20 14______ No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 544 ft² N N0
10/20/2020 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented) 0 54 ft² 0.1 Wood______ Bath Blown
2 Under Attic (Unvented) 0 308 ft² 0.1 Wood______ Master Sitting Blown
3 Under Attic (Unvented) 0 16 ft² 0.1 Wood______ Storage Blown
4 Under Attic (Unvented) 0 25 ft² 0.1 Wood______ Elevator Blown
5 Under Attic (Unvented) 0 141 ft² 0.1 Wood______ Stairwell Blown
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 19 0Bath 0006 8N Frame - Wood 0.60.25Exterior 48.0 ft² ____
2 19 0Bath 0009 8E Frame - Wood 0.60.25Exterior 72.0 ft² ____
3 19 0Master Sitting 00010 9N Frame - Wood 0.60.25Exterior 90.0 ft² ____
4 19 0Master Sitting 0009 9E Frame - Wood 0.60.25Exterior 81.0 ft² ____
5 19 0Master Sitting 00014 9S Frame - Wood 0.60.25Exterior 126.0 ft² ____
6 19 0Master Sitting 00025 9W Frame - Wood 0.60.25Exterior 225.0 ft² ____
7 19 0Storage 0004 9N Frame - Wood 0.60.25Exterior 36.0 ft² ____
8 19 0Storage 0004 9E Frame - Wood 0.60.25Exterior 36.0 ft² ____
9 19 0Stairwell 0007 9N Frame - Wood 0.60.25Exterior 63.0 ft² ____
10 19 0Stairwell 00010 9E Frame - Wood 0.60.25Exterior 90.0 ft² ____
11 19 0Stairwell 00013 9S Frame - Wood 0.60.25Exterior 117.0 ft² ____
12 19 0Stairwell 0007 9W Frame - Wood 0.60.25Exterior 63.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 E Low-E Single 0.65 0.25 9.0 ft² 1 ft 7 in 1 ft 4 in NoneMetal None______ Yes2 Y
2 E Low-E Single 0.65 0.25 9.0 ft² 1 ft 7 in 1 ft 4 in NoneMetal None______ Yes4 Y
3 S Low-E Single 0.65 0.25 32.9 ft² 1 ft 7 in 1 ft 4 in NoneMetal None______ Yes5 Y
4 W Low-E Single 0.65 0.25 27.1 ft² 1 ft 7 in 1 ft 4 in NoneMetal None______ Yes6 Y
5 N Low-E Single 0.65 0.25 9.0 ft² 1 ft 7 in 1 ft 4 in NoneMetal None______ Yes9 Y
6 E Low-E Single 0.65 0.25 9.0 ft² 1 ft 7 in 1 ft 4 in NoneMetal None______ Yes10 Y
7 S Low-E Single 0.65 0.25 18.1 ft² 1 ft 7 in 1 ft 4 in NoneMetal None______ Yes11 Y
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
564.9 731.01.000396Wholehouse .143258.32Proposed ACH(50)1
10/20/2020 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 17 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 16 18.8 kBtu/hr c f m 0.7______ sys#1Split 1 Singl
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.95 40 gal 60.9 gal 120 deg None______ None Attic
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 60 ft² Attic 15 ft² Default Leakage Attic ( D e f a u l t ) ______ 1 1 ( D e f a u l t )
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Bath
Default(8 lbs/sq.ft. f t ² f t 0.3 Master Sitting
Default(8 lbs/sq.ft. f t ² f t 0.3 Storage
Default(8 lbs/sq.ft. f t ² f t 0.3 Elevator
Default(8 lbs/sq.ft. f t ² f t 0.3 Stairwell
10/20/2020 10:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT