HomeMy WebLinkAbout01) 1st Floor Plan 2021 02 01 - KleinEXIST POOL WALL
EXIST, RD, WIN, -
NEW F.G. RD, WIN.
(MATCH EXIST" SIZE)
AHU ON SHELF - REMOVE
EXIST. W.H. (BELOW) - ADD
TANKLESS (GAS) W.H. TO
OUTSIDE
'
¢/ 0 <<
/",'L,64E
FFIT S'
V. BUILT-IN
1
DEN
\ REMOVE EXIST.
\ FR. DR, 8 S.L. -
NEW SL. GL, DR,
9 0, \
+8 \
O,, \
M�
NEW PRE-F B. MTL,
FIREF'L E - VERIFY NEW
FINIS W/ OWNER
LIVING ROOM
FLAT GLG"
\
\
.'i NEW ROLL-DN
� SCREEN FOR OPN'G.
BELOW BM.
NEW ROLL-DN
SCREEN FOR OPN'G.
BELOW BM.
SC
Pc
GENERAL ADDITION NOTES:
*THE DETAILS CONTAINED PER THESE PLANS MAY NOT BE
EXACT AND SHALL BE VERIFIED PRIOR TO ANY CONSTRUCTION
BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR)"
-OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) SHALL NOTIFY
ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING
CONSTRUCTION.
*EXISTING CONDITIONS ON ADDITIONS/RENOVATIONS ARE TO BE
VERIFIED BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR)
EXAMPLE: EXISTING SOFFIT MATERIALS, EXTERIOR FINISHES, TRIM
MATERIALS, ROOFING MATERIALS, FASCIAS, ETC"
*OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) IS RESPONSIBLE
FOR PROVIDING AND VERIFYING DESIGN GUIDELINES AND
RESTRICTIONS PER SUBDIVISION'S ARCHITECTURAL REVIEW BOARD.
-M.A. CORSON 8 ASSOC, INC. SHALL NOT BE LIABLE FOR ANY LOSS,
DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES.
*CONTRACTOR TO HAVE CERTIFIED FLORIDA SURVEYOR
LAYOUT BUILDING ON LOT TO ASSURE THAT NO SETBACKS
OR EASEMENTS ARE ENCROACHED. (OWNER, 8 OR
CONTRACTOR, IS RESPONSIBLE FOR PROVIDING SETBACKS,
EASEMENTS, LOT COVERAGES, ETC,)
<>
\
\
0,,
+<9 ENTR"T \ \ \ \
REOOVE EXIST. \
g, O,, f CAST STONE TRIM - \
)P +/ ADD STUCCO TRIM \
Otis o \\ \\
FOYER \
/REPLACE (2) S.H.\ \
\ 3 / WIN. W/ NEW \
F.G. - VERIFY \
+8, SIZE (S PLACES)
c o,,
\ \d
\ \ w I I
\ \ x I I
\ m 2, 6„ X O„ I I
RD. CONC.
COL. 6'' I I
I I +`4-
I I O
I I �
I I
I 10
I I 0
DINING ROOM
I 14
--- I I z
1 �
� I 1
*
* I I I
I I
I I
ARCHED
— — OPN'G
T
e P' R,
'
1 oven
tower
1
EXIST, SOFFIT ABV"
_,TO REMAIN
— — — -1
REMOVE EXIST.
SUPPLY
'
REF
SUMMER KIT" i
GAS LINE
'
25' 4" (BBQ E SINK)
TO ISLAND 10 0"
° O
REMOVE EXIST, I
O ==
;
N.R. WIN. - NEW I
O
LARGER II'O"Xa'O"
;
F.G. WIN. - VERIFY I
KITCHEN
KITCHEN
r - - - -
IDALLTH
\EENED GONG, G/OLS,)
REOEE EXIST. SOFFITS
�r
I I
I
RCI}�I
I 1 I
I
I
I
I
0
AT
WALL LEGEND
F,5,C, 201-1 (roTH EDITION) FOR
EXISTING 51JILDINGS
SUMMARY:
THE ALTERATION AREA HAS BEEN
DESIGNED TO: LEVEL 2
* Chapter 5 of the FBC 201-1 Existing Building
* less than 50% of the aggreregate area
* The lateral -force -resisting system of the existing
structure is adaquate to withstand any new lateral
loads of the new addition per Section &0-1.5 of the
201Z FBC Existing Buildings,
* The existing residence has hardwired smoke alarms and
the new addition shall be hardwired and interconnected
to the exist, system where accessible Per R314,3
201-T FBC,
THE ADDITION HAS BEEN DESIGNED TO: CHAPTER S
*Chapter 5 of the FBC 201-1 Existing Building
B 2011 FBC 8 CHAPTER (o OF ASCE 1-10
HOLLOW 8 HATCHED =
EXISTING WALL TO REMAIN
SOLID = NEW WALLS
DASHED = EXISTING
L---------- WALL TO BE REMOVED
AREA CALCULATIONS
Exist, 1st Floor a/c
3,405 S,F,
Exist, 2nd Floor a/c
1,301 S,F,
NEW 2nd Floor a/c
544 S,F,
Total A/C
5,250 S,F,
Garage
1,10E S,F,
Covered Patio
518 S,F,
Total Non A/C
1,62-1 S.F.
Total Under Roof
6,077 S,F,
* Contractors to verify all
footages
* All areas are calculated to
outside dimensions.
SCOPE OF
W0RK ,4REA -
TNIS M IT\
SH 36
4' 5" x 6' 4"
SH 36
REMOVE EXIST" 4' S" x 6' 4"
QUAD.WIN. - NEW
3'O"x3'O" F.G. 6Q,
4'O"X(0,0"
F,G, W/ TRANS,
VERIFY SIZE
-----------------------;
I1
GOLF CART
W I
1 9'0" GLG, HT,
1
1
1 '
1
'17771
----------------------
Digitally signed
by Mark A
Mark A. Corson
Corson Date:
2021.02.03
16:38:29-05'00'
-----------------------,
I ;
GARAGE
I
I 9' 10" GLG" HT. 0
0'2" ABV, (O'O' ,F,F) m
I'
I
o
I
I
m I ,
I
I
I '
I
I
I'
I '
I
I
I '
I
I
I
I'
I
I'
I
I
S" '
� 24' O°
I
I'
FIN, FL. a
sue/ \VARIES GUT BAC
NEW 8 GONG, STEP
___________ _ RELOCATED BACK TO
Panel Panel NEW WALL
-- ----
---taCaTroTr-------- ,-
-----
-I'I "
FIN" FL. RELOCATE[)
—
4 6 UP 3 a
m V
O 6" M RELOCATED
2 6"
I I
I —I ^ EXIST.
I I I I STEPS D
I I I I 0'0" FINIL.
L. p
I I dl
I I I I I Oil 3' all
I I I
lot
R&S ,
-_-_-_- �� M DIFYFLATGD ,—
A V. (FL. DEPTH) D
2ND FL WALL ABV.
- - -4 O - - -�-_T - - �- EXIST" - - I I -
EXIS U
` STL. D
STL. _ L
COLS.
I4 _ _ _ _ _
9'0" GLG. HT, \ I L_I__DW_-Jm
_LIG_L-----_*I 1
\ I I
------------ --------------- I- all X 6, 0"
\ NEW ROLL-DN F.G.
SCREEN FOR OPN'G, REVEE EXIST. NON-BRG.
`� ♦ BELOW BM. WALLS
FIXED SCREEN
NEW STUCCO ON \ ENGLOS. W/
i
BLK, RETAINING — — — DOOR — — — — —
WALL - MATCH --- -------
EXIST. SEE DETAIL
ON SHT, 8
0
+
REMOVE EXIST,
FIR, DR, 8 S,L, -
NEW FOLDING GL, DR.
T' 11 5/16"
MORNING IRM.
9'0" GLG. HT.
REMOVE EXIST"
9,H, WIN. - NEW
3'o"x&'o" F.G. WIN,
VERIFY SIZE
3' 1" x 6' 4"
SH 26
5' 4"
3' 1" x 6' 4"
SH 26
51011
TANKLESS
W,H. (GAS)
NEW - VERIFY
LOCATION
6
U
Q
>
(X
IL
H
X
W
13, O"
5EDROOM 2
5'O"x5,31,
EXIST. H.R. (IMPACT)
(TO BE PAINTED WHITE)
L.T.
s`
13' O" 5' Cc)"
W' 1.C. =—
BEDROOM 3
OMIT SINK 8 ADD CAB, W/ I-/AT1"f 3
KNEE SPACE I I
I
LINE OF BALCONY COLS. / I I O
[PIERS ABV. TO BE REMOVED �
l8 PLACES)
I
I I
MIR ' - - ' MIR
5,O"x5,31,
EXIST, H.R. (IMPACT)
(TO BE PAINTED WHITE)
NEW COND.
VLOJ
I
0
xO
OW
m
O
so
XLL
0
M
O
>
W
W 5' ICl" 3-- -Sir J I — 4, 6ii
- - - —
--- :-I -r- r OELEIxp c,
`I` I I I EQUIP,I I X z
I' REMOIVE I I I
�• ', E�IST; W,�4, ; ; cn *
TANKLESS
W.H. (G4ie
U
4
lL
NEW FREE
STANDING N
TUB X
W IL
o� F
EXIST" IMPACT
F,G,
EXIST" ELK. PRIVACY WALL
RELOCATE
EXIST. VAC
ICI)
U
U
o U
Z
O >
Z
O o
M N Z
O
0 4 N
4
c 9 - Q
°�
z�
(3q)
z�
(3
��u�u)zo
o Q) NO
n� ni =
n i N
I
u '�• Q W_ 2)l
IOL
Q IY
0
V
0 0
O
.4 N
E3
U 4
6 Q) 3
DATE 10/23/20
DRAWN BY pig me
CHECKED Mc
REVISIONS
11/30/20 PER B.D
�2/1/21 WORK AREA