Loading...
HomeMy WebLinkAbout02) 2nd Floor Plan 2021 02 01 - Klein7 F,PLACE NEW 42" HIGH ALUMIN, RAILING W/ TEMP, GL, PANELS - VERIFY W/ OWNER 5ALCONY I I - ------------------------------- ---------------------- n;=;=tj 5ELOW DN. BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS 4 SKYLIGHTS: PRODUCT MODEL ° MANUFACTURER ATTACHMENT METHOD BUILDING DESIGN PRESSURE EXPIR, DATE TYPE, SIZE, SPACING 4 EMBEDMENT APPROVAL# EVALUATION AGENCY PRODUCT DESIGN PRESSURE PGT 5/16" x 2 3/4" TAPCONS WINDOWS SH-5500 EVERY HOLE. ALL WINDOW +52,1 / -69,1 01/30/2025 (SINGLE HUNG) (IMPACT) SIZES SAME ATTACHMENT, +10,0 / -110,0 20-0401,03 MIAMI /DADE WORST CASE SCENARIO CALCULATED WINDOWS HR-5510 PGT 1/4" x 2 3/4" TAPCONS / 1*12 HEAD +52,1 / -69,1 09/24/2025 MIAMI / DADE (H. ROLLER) (IMPACT) +65,0 / -I10,0 20-0406,01 WINDOWS P111-5520 PGT # 1/4 x 2 3/4 TAPCONS / 12 HEAD +52,1 / -69,1 04/30/2025 MIAMI /DADE (FIXED GLJ (IMPACT) +50,0 / -I10,0 19-1126.10 SLIDING GLASS SGD-5510/2110 F'GT 1/4" x 2 3/4" TAPGONS / �12 HEAD +52,1 / -69,1 /0,-80, +60,0 -6 04/14/2021 MIAMI / DADE DOOR (IMPACT) -100 11-0420,06 FOLDING GLASS "6L-13" ALUM. NANA-WALL SYSTEMS (SEE MANUFACTURERS SPECS.) +52,1 / -69,1 N/A MIAMI /DADE DOORS (OUTSWING) (L.M.I. IMPACTS +14,5 / -14,5 FL-20101,2 FkRODUCT MODEL 0 MANUFACTURER ATTACHMENT METHOD BUILDING DESIGN PRESSURE EXPIR. DATE TYPE, SIZE, SPACING # EMBEDMENT APPROVAL # EVALUATION AGENCY PRODUCT DESIGN PRESSURE ROOFING IIBARCELONA BORAL ROOFING LLG 2 - lOd RING SHANK NAILS W/ ICP POLY- +18.1 / -14.2 04/2(o/2022 (CONCRETE yS" TILES 900 SET AH160 ROOF TILE ADHESIVE AH-160 -123,2 19-1021,11 MIAMI /DADE (54 GRAM LARGE PADDY)/ ROOF BUILT-UP '. POLYSTICK POLY GLASS USA NA 09/13/21 UNDERLAYI" LENT TILE PRO SELF -ADHERING (SEE PRODUCT SPECS) 11-0614,22 MIAMI / DADE NA +15,1 / -25,5 NA STUCCO NA STUCCO ON MTL. LATH MIAMI / DADE NA BUILDING DATA 4 1DE61GN PRESSURE SCHEDULE Pi;;�OJECT/NAME KLEIN JRESIPENCE ARCHITECT M,A, CORSON 8 ADDRESS: 12112 NW MARINER CT, ASSOCIATES, INC, ALL PRESSURE$ CALCULATED WITH THE FOLLOWING: I, WIND LOAD, BASED ON F,B,C, 2011 (6TH ED,) S, WALL ZONE (PSF): 4) +52,1 / -5(o.5 4 ASCE 1; 10', AND N.E.C. 2014 5) +52,1 / -613,1 2, BUILDING DESIGNED AS: ENCLOSED OPEN 9, GARAGE DOOR (PSF): +44,2 / -413,2 3, MEAN BUILDING HEIGHT: 24 FT, ROOF PITCH: 3,5 /12 10. LOADS: FLOOR roO PSF INTERNALS HRESSURE GOEFICIENT +/- : 0,10, ROOF/DEAD 15 PSF ROOF LIVE 30 PSF 4, WIDTH O�, END ZONE: 4' II, SHEAR WALLS CONSIDERED FOR STRUCTURE? WIND SPI$EO: ALT. I10 MPH 3 SECONO, GUST - YES X NO ` - NOMiNA,L= 132 -MPH 1 5, BUILDING` CLA55W-fC-AT VN-TA`BLE 1-I, ASCIE 1 12, CONTINUOUS LOAD PATH PROVIDED? YES X NO F,B,C, TABLE 1ioO4,5 , `, ; 13, ARE COMPONENT 4 CLADDING DETAILS PROVIDED? 6. EXPOSURE CATEGORY: D 4DJUSTMONT FACTOR: I,10 YES X NO 1, COMPONENTS 4 CLADDING WING PRESSURE ON: 14. SOIL BEARING CAPACITY: 2500 PSF ROOF ZONE (PSF): U +30.1 / -4113 ; PRESUMPTIVE: BY TEST: X 2) +30,1 / -53.3 3) / -123,2 15. TYPE CONSTRUCTION (TABLE 601) IIB -ALL ZONES CALCULATED FOR WORST CASE SCENARIO, (10 S,F, EFFECTIVE WIND 5' 4" 1' 411 AHU - - - - - - 1 I I , I ' UJ, I,C, ' 9'8" FLAT CLG, �1 1 ,11 I , i0 -- - - 12'0 3/4" F.F. N w N I IL lL w > O Q 1 N � � O - ----------------------------------------- N z X z (Y� MA8TER 5EDROOM OATH. CLG. 4' 011 REPLACE EXIST. I 2 CLOSET PKT, DRS, ' , ;EXIST 2 '.'AHU A h41 011 •----- F I 0 I I Ili/ o l II II � II I I 0- 1- JJ I I L---JI I I I • • • I I I I I I I F----1I NOTE: CLOSET BUILD -IN ' DESIGN BY OTHERS - I VERIFY W/ OWNER I I li I L - - -J I � �I I I 3' 1" x 6' 4" I 13' 1" x 6' 4' SH 26 SH 26 - I Digitally signed by Mark A ' Mark A. Corson I I I I I I Corson Date: 2021.02.03 I I I I I I I I I I I I 16:39:06-05'00' I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I NOTE:(MOO (000) I I I I * WINDOWS 4 DOORS TO NAVE GREY TINT I I I I * WHITE FRAMES WO KI , I ; I I I I I I I I I I I 0 1 I I 1 W m � I YJ I J I I I I I I T 15 E MIT � I I I I I f=> U- GARAGE BELOW I I I I I I I I I I I I I I I I STAIR NOTE: 23 EQ, RISERS m 1,25" = 13'10 3/4" ftm 0- RAILING 210" ABV, EDGE OF TR, In I" NOSING TYP. 3 - 2 x 12 STRINGERS J I J (2) 1,25" RISERS + (1)10" TREAD = 24,5" -q 20' 0" 2' 4" I I I �01I I F I i 3 I SH I I O 2211x4' I I I ww Im I I I I LL f N N I I r - Ql T II I I I I I I I I 2 8 I I ------------ -, IST, FL. WALL BELOW ----------- - .. `---------------- i-----------' `--------- i------i---------' `-------1---' ; {------ ------ 3' 8ll 5' 10 3' S i-j- - - - - ---------- - - - - -' J-------'------'-------------- ----- ------ --� -- 0 �� Im x J( H - CV � I I U% J In I I N (ii w 20' roll 41 411 14' 2V2" 1' 5'h" I I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - , - - - - - - - - - - - - - - - - - -------, ----------------------- TEMP. GL. ON 42" ------------- REMOVE EXIST, 5Tg4M UNIT 4 `,WALL 4 TEMP. GL. W.H. ADD NEW STACK W/D 21 2" x 4' 2" - I � I1�OR 7' 2' x 4' 2' 4 GAS TANKLESS W.1H, ON EXT. SH H34 SH H34 x = WALL tLOWDN I � CV Chi - I I •- --^' o o o o M �ojl� m 3, 011 N N I I ' p ' ® , 4o 'SPACE �% KNEE -- - - - ----•' N WALL -- ,�. ." tJ� - �t ' I REMOVE ., 11-"f m '/4 RECESS 11� EXIST, DR. ASTER � � I' . 1, ,", - AE5^i. &'0" CLG. / TILE x N %� t J� 21 81 61 0" L - 1 ----- �7""t 11-f _ -`- ------------------- ---- �r --- ---- i- nTu / i 2'�"xG 's3" - - - - - - -IST. FL. WALL BELO , p= , w0 , UX F - - - - - - - - - - - - 0 , XT MP. GL. FROM w (Y FL. TO S' FRO - 44" WALL HT, VE IFY W/ OWNER11 - OMIT l ; �.',' BIDET 2 � , , , , , , , 1 i m p - 9' 4° c3 5' SPRING HT, ua 0 r Q ACCESS DOOR Q _x ' ABV, FOR AHU •-------- ---------d�-• �•--- ----------- ------------------------------------------------------------------- - w W (Y N C° m 0 REMOVE EXIST 67 t DR, 4 WINDOWS MASTER SITTING m FRAME IN - OATH. CLG. - 13'0" SPRING HT. MATCH EXIST, TILE FL. RAIN ®NERD ABV. &1 0" 2' 4" x 41 2" 2' 4" x 4' 2" 2' 2" x 41 2" 2' 2" x 4' 2" F,G, SH SH SH H34 SH H34 EXIST, BALCONY 11 PIERS / COLS, 1' O 11 1' 8 TO BE REMOVED 20 (o" (S PLACES) 30' 211 REMOVE EXIST, SHWR. VALVES 4 SPRAYERS REPLGE W/ NEW - PER OWNER'S SELECTIONS a a MARBLE WALL SLAB 4 LINEAR a RAIN AT FL, A I I I I 21 211 x 41 211 SH H34 1' all 1 11011 41 1011 U 6 ' 0 6 z °6> z 6o 7� N z D1�c5 6 0 4 N 4 c 9 6 Q O w , rn °' z� z� �Q)u�u)zo 'n OU OU 0 0 U WO J a m Q S Q m U 4 t 6 3 3 DATE 10/23/20 DRAWN BY pie Inc CHECKED Mc REVISIONS 11/30/20 PER 5-D \2/1/21 WORK AREA