HomeMy WebLinkAbout02) 2nd Floor Plan 2021 02 01 - Klein7 F,PLACE
NEW 42" HIGH
ALUMIN, RAILING
W/ TEMP, GL,
PANELS - VERIFY
W/ OWNER
5ALCONY
I I
- -------------------------------
----------------------
n;=;=tj
5ELOW
DN.
BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS 4 SKYLIGHTS:
PRODUCT
MODEL °
MANUFACTURER
ATTACHMENT METHOD
BUILDING DESIGN
PRESSURE
EXPIR, DATE
TYPE, SIZE, SPACING 4 EMBEDMENT
APPROVAL#
EVALUATION AGENCY
PRODUCT DESIGN
PRESSURE
PGT
5/16" x 2 3/4" TAPCONS
WINDOWS
SH-5500
EVERY HOLE. ALL WINDOW
+52,1 / -69,1
01/30/2025
(SINGLE HUNG)
(IMPACT)
SIZES SAME ATTACHMENT,
+10,0 / -110,0
20-0401,03
MIAMI /DADE
WORST CASE SCENARIO CALCULATED
WINDOWS
HR-5510
PGT
1/4" x 2 3/4" TAPCONS / 1*12 HEAD
+52,1 / -69,1
09/24/2025
MIAMI / DADE
(H. ROLLER)
(IMPACT)
+65,0 / -I10,0
20-0406,01
WINDOWS
P111-5520
PGT
#
1/4 x 2 3/4 TAPCONS / 12 HEAD
+52,1 / -69,1
04/30/2025
MIAMI /DADE
(FIXED GLJ
(IMPACT)
+50,0 / -I10,0
19-1126.10
SLIDING GLASS
SGD-5510/2110
F'GT
1/4" x 2 3/4" TAPGONS / �12 HEAD
+52,1 / -69,1
/0,-80, +60,0 -6
04/14/2021
MIAMI / DADE
DOOR
(IMPACT)
-100
11-0420,06
FOLDING GLASS
"6L-13" ALUM.
NANA-WALL SYSTEMS
(SEE MANUFACTURERS SPECS.)
+52,1 / -69,1
N/A
MIAMI /DADE
DOORS (OUTSWING)
(L.M.I. IMPACTS
+14,5 / -14,5
FL-20101,2
FkRODUCT
MODEL 0
MANUFACTURER
ATTACHMENT METHOD
BUILDING DESIGN
PRESSURE
EXPIR. DATE
TYPE, SIZE, SPACING # EMBEDMENT
APPROVAL #
EVALUATION AGENCY
PRODUCT DESIGN
PRESSURE
ROOFING
IIBARCELONA
BORAL ROOFING LLG
2 - lOd RING SHANK NAILS W/ ICP POLY-
+18.1 / -14.2
04/2(o/2022
(CONCRETE yS" TILES
900
SET AH160 ROOF TILE ADHESIVE AH-160
-123,2
19-1021,11
MIAMI /DADE
(54 GRAM LARGE PADDY)/
ROOF BUILT-UP '.
POLYSTICK
POLY GLASS USA
NA
09/13/21
UNDERLAYI" LENT
TILE PRO
SELF -ADHERING (SEE PRODUCT SPECS)
11-0614,22
MIAMI / DADE
NA
+15,1 / -25,5
NA
STUCCO
NA
STUCCO ON MTL. LATH
MIAMI / DADE
NA
BUILDING DATA 4 1DE61GN PRESSURE SCHEDULE
Pi;;�OJECT/NAME
KLEIN JRESIPENCE
ARCHITECT
M,A, CORSON 8
ADDRESS:
12112 NW MARINER CT,
ASSOCIATES, INC,
ALL PRESSURE$ CALCULATED WITH THE FOLLOWING:
I, WIND LOAD, BASED ON F,B,C, 2011 (6TH ED,)
S, WALL ZONE (PSF): 4) +52,1 / -5(o.5
4 ASCE 1; 10', AND N.E.C. 2014
5) +52,1 / -613,1
2, BUILDING DESIGNED AS: ENCLOSED OPEN
9, GARAGE DOOR (PSF): +44,2 / -413,2
3, MEAN BUILDING HEIGHT: 24 FT, ROOF PITCH: 3,5 /12
10. LOADS: FLOOR roO PSF
INTERNALS HRESSURE GOEFICIENT +/- : 0,10,
ROOF/DEAD 15 PSF ROOF LIVE 30 PSF
4, WIDTH O�, END ZONE: 4'
II, SHEAR WALLS CONSIDERED FOR STRUCTURE?
WIND SPI$EO: ALT. I10 MPH 3 SECONO, GUST -
YES X NO
` - NOMiNA,L= 132 -MPH 1
5, BUILDING` CLA55W-fC-AT VN-TA`BLE 1-I, ASCIE 1
12, CONTINUOUS LOAD PATH PROVIDED?
YES X NO
F,B,C, TABLE 1ioO4,5 , `, ;
13, ARE COMPONENT 4 CLADDING DETAILS PROVIDED?
6. EXPOSURE CATEGORY: D 4DJUSTMONT FACTOR: I,10
YES X NO
1, COMPONENTS 4 CLADDING WING PRESSURE ON:
14. SOIL BEARING CAPACITY: 2500 PSF
ROOF ZONE (PSF): U +30.1 / -4113 ;
PRESUMPTIVE: BY TEST: X
2) +30,1 / -53.3 3) / -123,2
15. TYPE CONSTRUCTION (TABLE 601) IIB
-ALL ZONES CALCULATED FOR WORST CASE SCENARIO, (10 S,F, EFFECTIVE WIND
5' 4"
1' 411
AHU - - - - - -
1
I
I ,
I '
UJ, I,C, '
9'8" FLAT CLG, �1
1 ,11
I ,
i0 -- - -
12'0 3/4" F.F.
N
w
N I
IL lL
w
>
O Q 1 N
� � O
- -----------------------------------------
N z X
z (Y� MA8TER
5EDROOM
OATH. CLG.
4' 011
REPLACE EXIST.
I 2 CLOSET PKT, DRS, '
, ;EXIST
2 '.'AHU A
h41 011 •-----
F
I
0
I I
Ili/ o l II
II � II
I I
0- 1- JJ
I I
L---JI I
I I
• • • I I
I I
I I
I
F----1I
NOTE:
CLOSET BUILD -IN '
DESIGN BY OTHERS - I
VERIFY W/ OWNER
I
I li I
L - - -J
I �
�I
I I
3' 1" x 6' 4" I 13' 1" x 6' 4'
SH 26 SH 26
- I
Digitally signed
by Mark A
' Mark A. Corson
I I I I I I
Corson Date:
2021.02.03
I I I I
I I I I
I I I I
16:39:06-05'00'
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I
I I I I I I
I I I I
I I I I
I I I I
I I I
I I I I
NOTE:(MOO (000)
I I I I
* WINDOWS 4 DOORS TO NAVE
GREY TINT
I I I I
* WHITE FRAMES
WO KI , I
;
I I I
I I I I
I I I I
0 1 I I 1
W
m � I
YJ I
J
I
I
I I I I
T 15 E MIT
� I I I
I I
f=>
U-
GARAGE BELOW
I I I I
I I I I
I I I I
I I I I
STAIR NOTE:
23 EQ, RISERS m 1,25" = 13'10 3/4"
ftm 0- RAILING 210" ABV, EDGE OF TR, In
I" NOSING TYP. 3 - 2 x 12 STRINGERS J
I J
(2) 1,25" RISERS + (1)10" TREAD = 24,5" -q
20' 0"
2' 4" I I
I �01I I F
I i 3 I
SH
I I
O 2211x4'
I I I
ww
Im
I I I I
LL f N N
I I r -
Ql
T II I
I I I I I I I 2 8 I I
------------ -, IST, FL. WALL BELOW ----------- - ..
`---------------- i-----------' `--------- i------i---------' `-------1---' ; {------ ------ 3' 8ll
5' 10 3' S
i-j- - - - - ---------- - - - - -' J-------'------'-------------- ----- ------ --� -- 0 ��
Im x J( H -
CV �
I I
U% J In I I
N (ii w
20' roll 41 411 14' 2V2" 1' 5'h"
I I
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - , - - - - - - - - - - - - - - - - -
-------, ----------------------- TEMP. GL. ON 42"
-------------
REMOVE EXIST, 5Tg4M UNIT 4 `,WALL 4 TEMP. GL.
W.H. ADD NEW STACK W/D 21 2" x 4' 2"
- I � I1�OR 7' 2' x 4' 2'
4 GAS TANKLESS W.1H, ON EXT. SH H34 SH H34 x =
WALL tLOWDN I � CV Chi - I I
•- --^' o o o o M �ojl� m 3, 011 N N
I I '
p ' ® ,
4o 'SPACE �%
KNEE -- - - -
----•' N WALL -- ,�. ." tJ� - �t
' I REMOVE ., 11-"f m
'/4
RECESS 11�
EXIST, DR. ASTER � � I' . 1, ,",
- AE5^i. &'0" CLG. / TILE x N
%� t J� 21 81 61 0" L - 1
----- �7""t 11-f _ -`- ------------------- ---- �r
--- ----
i- nTu / i 2'�"xG 's3" - - - - - - -IST. FL. WALL BELO
,
p= ,
w0 ,
UX F - - - - - - - - - - - -
0 ,
XT MP. GL. FROM
w (Y FL. TO S' FRO
-
44" WALL HT, VE IFY W/ OWNER11
- OMIT l ; �.','
BIDET
2 �
,
,
,
,
,
,
,
1
i
m
p - 9' 4°
c3 5' SPRING HT, ua 0
r
Q ACCESS DOOR
Q _x ' ABV, FOR AHU
•-------- ---------d�-• �•--- ----------- ------------------------------------------------------------------- -
w W
(Y N C° m
0 REMOVE EXIST 67 t
DR, 4
WINDOWS MASTER SITTING
m
FRAME IN - OATH. CLG. - 13'0" SPRING HT.
MATCH
EXIST, TILE FL.
RAIN
®NERD ABV.
&1 0" 2' 4" x 41 2" 2' 4" x 4' 2" 2'
2" x 41 2" 2' 2" x 4' 2"
F,G, SH SH SH H34 SH H34
EXIST, BALCONY
11
PIERS / COLS, 1' O 11 1' 8
TO BE REMOVED
20 (o" (S PLACES) 30' 211
REMOVE EXIST, SHWR. VALVES 4 SPRAYERS
REPLGE W/ NEW - PER OWNER'S SELECTIONS
a
a MARBLE WALL SLAB 4 LINEAR
a RAIN AT FL, A
I I
I I
21 211
x 41 211
SH H34
1' all 1 11011
41 1011
U
6 '
0 6
z
°6>
z
6o
7� N z
D1�c5 6
0 4 N
4
c 9 6 Q
O w
,
rn
°'
z�
z�
�Q)u�u)zo
'n
OU
OU
0 0 U
WO J
a
m Q S Q m
U 4
t 6 3 3
DATE 10/23/20
DRAWN BY pie Inc
CHECKED Mc
REVISIONS
11/30/20 PER 5-D