HomeMy WebLinkAbout09) 1st Floor Electric Plan 2021 02 01 - KleinME `V 7 F,PLACE I I I I I \ I I I I I I I I I I I I I I I I I I I I I� I I it Florida Building Code roth Edition (2017) Energy Conservation C402,5,5 Recessed lighting, Recessed luminaires installed in the building thermal envelope shall be all of the following: I, IG-rated, 2,La1c)eled as having an air leakage rate of not more 2,0 cfm (0,S44 L/s) when tested in accordance with ASTM E253 at a 1,5-T psf (15 Pa) pressure differential, 3,5ealed with a gasket or caulk between the housing and Interior wall or ceiling covering. (See Section C402,5.(B applicable Building cavities) C402,5.5,1 Vented dropped ceiling cavities, C402,5,S,2 Unvented dropped ceiling cavities, C402,5,5,3 Separate tenancies, C402,5,5.4 Air distribution system components, oven tower LOAD GALCULATiON5 EXIST. SERVICE FEEDER: 250 AMP EXIST, PANEL SIZE: (1) 42 CIRCUIT (VERIFY) EXISTING LOADS 3113 SQ. FT, x 3 WATT = 9,33C3 Watts 2 SMALL APPLI, a 1500 3000 Watts 1 LAUNDRY 1500 Watts 1 RANGE 5,000 Watts 1 DISHWASHER 1500 Watts 1 DISPOSAL 1500 Watts 1 MICROWAVE 2000 Watts 1 WATER HEATER 4500 Watts 1 DRYER 5000 Watts OTHER OTHER OTHER SUB TOTAL: 36,339 Watts NEW LOADS 149 SQ. FT. x 3 WATT = 441 Watts 16(o SQ. FT, x 3 WATT = 495 Watts OTHER _ OTHER OTHER TOTAL WATTS: 3-1,254 Watts 1ST 10 KW 6 1009. (x2) 1-1,500 Watts REMAINDER @ 40% TeI3 Watts A/C HEAT a 10051. 10,000 Watts TOTAL WATTS 35,413 Watts DIVIDED BY 240 VOLTS = NEW 14-1,5 Amps EXISTING 250 AMP POWER SUPPLY SUFFICIENT. 2014 NEC 210,12 (A) Arc -Fault Circuit -Interrupter Protection, Dwelling Units, All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets installed or devices in 671 unit kitchens, family rooms, dining rooms, living rooms, par r , libraries, dens, sun rooms, recreation rooms, closets, hallw laundy areas or similar rooms or areas shall be protected any of the means described in the NEC 2011 210,12 (A)(1) through (6) 2014 NEC, 406,12 Tamper -resistant receptacles in are required in dwelling I nits all areas as specified in 2014 NEC 406,12(A) through All 125-volt, 15- and 20-ampere receptacles, I ELECTRICAL LEGEND ELECTRICAL SYMBOL Can Light 0 Disconnect disc Pendant Light Push Button PB 4 outlet 0 outlet 220v 6 outlet gfi & switch $ switch 3 way $3 wall light exterior Qj SCOPE Of= WO K A E A T 16 PERMIT I I I I I I II MIRQ (0 TANKLESS W,H, (CAS) NEW - VERIFY LOCATION D -----------------------, I I I I I I I I Tb exist, garage light circut. N I I , \I omw ,\ ' \ NEW PANELS 8 NEW PANEL LOCATION - ------- ____�_ ____ VERIFY ON THE JOB a Panel Panel It QL 1 � 1 � 1 � I � 0 0 TANKLESS W,H, (GAii Digitally signed by Mark A Mark A. Corson Corson Date: 2021.02.03 16:41:50-05'00' U U I 0 U z p z) �tu `9 Qd) O„ W 4 Q) „,s Q� Q13 m 9 �z oN zD1� o- 7) Q) Qz o O c0 lX MC cp a :� Q) iy u c N Q � U 4 6 T T 3 N • U Z � V V a (VIA � OUP dN 3 4.6 Oo III, ` U� •� O W � DATE : 10/23/20 DRAWN BY: p,jg me CHECKED ric REVISIONS 11/30/20 PER B.D 11\2/1/21 WORK AREA