Loading...
HomeMy WebLinkAboutBuilding PlansC A 1iLJ 1i1 9 i 1430 CUL_VER C)RIVE NE, PALM BAY, FIL 32907 • STATE OF FLORIDA DESIGN CRITERIA: CERTIFIED BUILDING CONTRACTOR: .IrwjmA BUIIAING CODE, RESIDENTIAL, 6TH EDITION (2017) • ALL LOCAL AND STATE CODES DR HORTON HOMES _ 1430 CULVER DRIVE NE PALM BAY, FL 32907 TEL: (321) 733-7092 FAX: (321) 733-7972 • STATE OF FLORIDA PROFESSIONAL ARCHITECT: MICHAEL C. ANDERSON AR No. 17305 A.B. DESIGN GROUP, LLC 2194 HWY AM SUITE 301 INDIAN HARBOUR BEACH, FL 32937 Tel: (321) 802-3591 DRAWING / CONTRACT DOCUMENT REVIEW BY BUILDER THE BUILDER ASSUMES ALL LIABILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS. IF ANY ASPECT OF THE CONSTRUCTION (AS DESCRIBED IN THIS DRAWING SET) ARE UNCLEAR AND IN NEED OF FURTHER DETAILING OR EXPLANATION IN ORDER TO BUILD THIS PROJECT BASED ON THIS DRAWING SET, THE CORRECT PROCEDURE IS FOR THE BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR INFORMATION) TO THE ARCHITECT OR ENGINEER FOR CLARIFICATION. AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN BFI's IN WRITTEN/DRAWN FORMS IN A TIMELY MANNER. AB DESIGN GROUP TAKES NO RESPONSIBILITY FOR INTERPRETATIONS OF CONSTRUCTION BY THE BUILDER WHEN NO RFI's HAVE BEEN GENERATED FOR UNCLEAR ASPECTS OF THE CONSTRUCTION BASED ON THE DRAWING SET. *OCCUPANCY •CONSTRUCTION TYPE • MIN. INTERIOR FINISH • BASIC WIND SPEED •EXPOSURE *I -STORY RESIDENCE •2-STORY RESIDENCE - RESIDENTIAL, GROUP R3 - VB - CLASS B - Vult=160 MPH Vasd=124 MPH -C - MAX. HEIGHT AS PER LOCAL AND STATE CODES SQ.FT. CALC.'S LIVING 1828 SQ. FT. GARAGE 430 SQ. FT. ENTRY 16 SQ. FT. LANAI 88 SQ. FT. TOTAL 2362 SQ. FT. A/C VOLUME 15-120.cJ CU. FT. Tel: (321) 733-7092 Fax: (321) 733-7972 FA"so] C1DMA /:VY[IhS t4oklW[I7►f ABV. ABOVE LAV, LAVATORY DATE I DESCRIPTION 01/26/18 CD'S ISSUED AIC ADJ, AIR CONDITIONING_ ADJUSTABLE LUM. M.C. LUMINOUS MEDICINE CABINET 01/15/18 2011 FBC UPDATE ALT, ALTERNATE MFR. MANUFACTURER AMP. AMPERAGE MIN. MTNIMTTM 01/16A8 C016IE-I65UED BD. BOARD M.T. MP.TALTHRESHOLD CL CAB CENTER LINK (:ABINET MTD. MTL. MOUNTED METAL 02/21Ab SIDING ELEVATIONS ADDED CLG_ CLR. CEILING CLEAR N.T.S. QC. NOT TO SCALE ON ('ENTER 03/16Ab CD'S-ISSUED 0411548 FOOTNG REVISION PER M. BOWES CONC CPT. CONCRETE CARPET PL P.B. PROPERTY LINE PUSH BUTTON 06R148 CD'S RE -ISSUED C T CERAMIC TILE PH, PHONT, D. DRYER ?LT. PLATE; 02/19A9 ADDED CURBLESS FOOTER AT GARAGE DETAIL (FORT MYERS) DBT.. DOT JBLF PLYWD. PLYWOOD P.G. DTIAL GLAZED PR. PAIR DIA. DIAMETER P.T_ PRESSURE TREATED 02/22/19 PLAN MAINTENANCE DIM, DISP. DIMENSION DISPOSAL R. RAD. RISER RADIUS 03128A9 REVISED LINTEL SIZE AT F"T ENTRY DOOR 04/24/19 ADDED ADDITIONAL RECEPTACLE IN GARAGE PER WILL BATSON (M DP. DR. DEEP DOOR R.A.G. REF. RETURN AIR GRILL REFRIGERATOR 04/24A9 REVISED HVAC VOLUMES ON SQFT CALC SCHEDULE (MELB.) D.S. DOWNSPOUT RM. ROOM DTI.. DETAIL R.O. ROUGH OPT,NTNG 06112A9 ADDED 'EXTERIOR MONO DEEP FOOTER' DETAIL 12/51.IA (ORL) D.W. DISHWASHER S.C. SOLID CORE. T.xT DR EA FILEV. EACH FLEVATION S.D. S.H. SMOKE DETECTOR SINGLE HUNG 06/21A9 ADDED LED LIGHTS is KITCHEN 4 BATH PER MARK BOWES EQ. EXIT. AUST EXHAUST SHESHAT SHTHG. SHEATHINGEXHAT. 01ASI19 ADDED STONE OPTION ELEVATION C 4 D (TAMPA) 09A1A9 ELEVATION 'G' SIDING -ADDED LOUVER a GABLE ROOF FXT. F (iiFX. EXTERIORIGLASS FIXED GLASS Sim. SIM. SIMILAR. SIMILAR 10/25A9 ADDED OFT. 6-0' CEILING HEIGHTS ' F.G. FUEL GAS SL. SLIDING FIN. FINISH SL. CF. SLIDING GLASS 01/01/20 REPLACE USP CONNECTORS WITH SIMPSON CONNECTORS FLR. FLOOR STD, STANDARD FLUOR- TR. DR. FLUORESCENT TRENCFI DOOR SWS SHEAR WATT. SECTION 04/01/20 REVISE ENKAVENT RADON PLAN DIMENSIONS FIG. GA. GAUGE CAl1GP, TEMP. THK. TFMPEREDGLASS THICK 04/09/20 OPT 6-0' CLG. HGT: ADDED LED LIGHT IN FOYER 04/09/10 OPT. 6-0' CLG. HGT. ELEVATION 'C'- REVISED HEIGHT OF ARCHWAY GAR. DISP. G_F I GARBAGE DISPOSAL GROUND -FAULT CIRCUIT T.O.C.. T.O.P. TOP OF CURB TOP OF PLATE INTERRUPTER T.O.S. TOP OF SLAB GL GLASS TYP, TYPICAL GYP. BD. GYPSUM BOARD ITN.O_ UNLISS NOTED H.B. HOSEBTF3 OTHERWISE H.0 HOLLOW CORE VP. VAPOR PROOF HDR_ HEADER W. WASHER HGT. OR HT HEIGHT W' WITH INSUL. INSULATION WD. WOOD TNT. INTERIOR WDW. WINDOW W:H WATER HEATER W.l. WROUGHT IRON INDEX OF DRAWINGS ARCHITECTURAL SHEET # PG Cl—COVER SHEET PG GN—GENERAL NOTES PG Al —FLOOR PLAN PG A2C—ELEVATION "C" PG E1—ELECTRICAL PLAN PG P1—PLUMBING PLAN PG M1—HVAC PLAN PG D1—DETAILS PG D2—DETAILS PG WA1—WALL ASSEMBLY DETAILS PG WA2—WALL ASSEMBLY DETAILS PG WA3—WALL ASSEMBLY DETAILS PG WA6—WALL ASSEMBLY DETAILS STRUCTURAL SHEE PG S1—FOUNDATION PLAN PG S1.1A—DETAILS PG S1.2—DOWEL PLAN DESCRIPTION DESCRIPTIO [a PG S1.2A—DETAILS ty PG S2—LIFT BEAM PLAN AND NOTES PG S2.1A—DETAILS PG S3—FRAMING PLAN PG S3.1A—DETAILS PG S3.1B—DETAILS PG S3.1C—DETAILS PG SN1—DETAILS PC = PAI —PRODUCT APPROVALS I- C-51po Reviewed Tor Code Comp9ance Universal Engfneefing sclences 0 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W y U `J. ti F V W 4 F A F ti 141 r to W SUHDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: COVER SHEET 160 MPH EXP. C ARCHrrECT- STATE OF FLORIDA AUG 0 6 2020 kEL C. ANDEI AR NO 17305 rrcain JL DATE: OB 05 20 SCALE: 1/4"= V — 0" SHEET cI GENERAL NOTES 1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IIN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR) 6th EDITION, (2017) . ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED IN THESE DOCUMENTS ARE UNDER FBCR 6TH EDITION (2017) UNO. 2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE iN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.1.2. 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. 4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/OR FABRICATION OF THE WORK. 5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. 6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. 7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. 8 THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. 9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. GARAGES AND CARPORTS 1. GARAGE DOOR A. ENGINEERED FOR MIN. WIND LOAD, LISTED ON COVER SHEET B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER 2. AS PER SECTION R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1-3/8 INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS, 3. AS PER SECTION R302.5.2. DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO.26 GAGE (0.48 MM) SHEET STEEL 1" MIN. RIGID ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 4. AS PER SECTION R302.6 & TABLE R302.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN '/2 -INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 518 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN''/z-INCH GYPSUM BOARD OR EQUIVALENT. SITE WORK 1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT). 2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, SITE IMPROVEMENTS, SITE RETAINING WALLS; AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL FINISH GRADES, PLANTING AND IRRIGATION. 3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE ARCHITECT. 4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN Yz THE HORIZONTAL DISTANCE FROM THE NEAREST EDGE OF THE FOOTING. 5. ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAN GRANULAR FILL. PLACE IN 8" LAYER AND COMPACT TO 95% MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557. THE BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS. 6. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. 7. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) 8. EXCAVATIONS TO BE A MINIMUM OF T- 0" BEYOND NEW FOOTING LINE. 9. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE REQUIREMENTS. 10ECONTRACTORI IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY H COMPLIES WITH ALL LOCAL CODES HAVING JURISTICTION, INCLUDING ALL APPLICABLE STATE, CITY AND NTY BUILDING AND ZONING CODES. IF CONSTRUCTED IN A FLOOD ZONE, SOIL CONDITIONS MUST BE MODIFIED LACE THE FINISHED FLOOR ELEVATION MIN 1'-0" ABOVE THE BFE,_PER FLORIDA BUILDING CODE: 11. SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP DRAWING. 12, TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT; A'CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES, TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHPBY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES,` TIMBER 1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED HEREIN: A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) B. NATIONAL FOREST PRODUCTS ASSOCIATION: I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION C. SOUTHERN PINE INSPECTION BUREAU: I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER D. TRUSS PLATE INSTITUTE: I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI 1-2014) E. APA- THE ENGINEERED WOOD ASSOCIATION: I. ENGINEERED WOOD CONSTRUCTION GUIDE F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS S 2: ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. 3. MINIMUM NAILING PER CHAPTER 6- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS. 4. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION. 5. WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOFIWALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1. 6. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT : SQ. PLUMBING 1 SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. 2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX "A" (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. 3. CONDENSATION LINES SHALL BE MINIMUM 3W' PVC (SCHEDULE 40), INSULATED WITH%," AMAFLEX. 4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH, 5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. 6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. �I 7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO SECTION P3005.2. 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903• 9. THE PLUMBER IS TO DIVERT,ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. 10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHRILL FOLLOW PROVISIONS OF SECTION P2603.2. EXTERIOR WALL COVERINGS 1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR THE WALLS FOR COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH TABLE R301:2(2) AS MODIFIED BY TABLE R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE EXTERIOR FINISHES 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %" THICK, OVER FRAMED WALLS APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS THAN 2 COATS, 1/2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE. 2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM-C926 & ASTM-C1063-12a. 3. LATH & ACCESORIES PER ASTM-C-1063-11A & R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO ALL STUCCO CONTROL JOINTS KICK -OUT DETAILS "L" FLASHING HORIZONTAL LATH AND PAPER DETAILS PIPE PENETRATION; DETAILS VENT PENETRATION DETAILS WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS CASING BEAD DETAILS DRIP EDGE DETAILS CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS WINDOW FLASH INGIDETAILS 4. SHALL BE INSTALLED PER ASTM-C1063 -15A AND R703.7. FIRE RESISTANT CONSTRUCTION UNDER STAIR PROTECTION: 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. R302.7. EXTERIOR CEILINGS 1. EXTERIOR CEILING TO BE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING MEMBERS: THE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1 1/4" TYPE "W" DRYWALL SCREWS AT 12" O.C. (PER MANUFACTURER'S SPECIFICATIONS) . CONSTRUCTION OBSERVATION CONSTRUCTION OBSERVATION SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT A PART OF AB DESIGN GROUP'S SERVICES FOR THIS PROJECT. IT IS UNDERSTOOD AND AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW OF THE BUILDER'S / CONTRACTOR'S � PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL BE PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND FOR CONSTRUCTION OBSERVATION. r)I Reviewed For Code Compliance Universal Engineering Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 vv w. a b d es i g n gro u p. co m AA #: 0003325 E w h w U Z w F n 0. w n � Q m F cli n A e - 4; I� ^BDIV. 8e LOT- "4CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL: Ll fl 4EBB "1828-CALI" (GARAGE SWING: k{ RIGHT ..'iIAGE: 11 GENERAL NOTES �.fi0 MPH EXP. C ARCHITECT. STATE OF FLORID,." OCT 2 12020 :HAEL C. ANDEI AR NO 17305 PRINT DATE- 08 05 20 SCALE: 1/4"-1' - 0" 141 oz �OoF FIGURE Si:gn COMPONFHT AND LA DIN PRESSURE VCME _ er"yl' :\I SCALE: 1/4' = 1'-0' NOTE: -2-8 LOUV. DOOR W/ AIR HANDLER ON METAL STAND OR 2-8 SOLID DOOR W/ RETURN PLENUM AND RETURN AIR GRILLE. - VERIFY CONDENSER PAD LOCATION WITH SITE PLAN. -OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/8' (35 MM) IN THICKNESS, SOLID OR HONEYCOMB -CORE STEEL DOORS NOT LESS THAN 1 3/8" (35 MM) THICK, OR 20-MINUTE FIRE -RATED DOORS. - EGRESS NOTE: DO NOT SHUTTER FRONT DOOR FRONT ENTRY DOOR TO BE EGRESS POINT WHEN THE HOME IS SHUTTERED. - REFER TO BUCKING DETAILS FOR BUCKING AND RO NOTES. -FRAMED WALL SEPARATION BETWEEN THE UNCONDITIONED GARAGE AND CONDITIONED SPACED SHALL HAVE AN INSULATION R VALUE OF R-13. -CEILING R VALUE TO BE R-30 INSULATION ABOVE CONDITIONED SPACE. -FOR CONSISTENCY, THE VOLUME CALCULATIONS ON PLANS ARE PROVIDED BY THE HVAC CONTRACTOR AND ARE OF THEIR CLOSEST ALLOWABLE SOFTWARE TOLERANCES. -OPENING INFORMATION BELOW IS DIRECTLY FROM THE PLAN SET. U-VALUE AND SHCG ARE INFORMATION PROVIDED BY THE MANUFACTURER AS LISTED IN THE RESPECTIVE PRODUCT SPECIFICATIONS u��mm SQ.FT. CAM'S LIVING GARAGE ENTRY LANAI88 1828 SQ. FT. 430 SQ. FT. 16 SQ. FT_ SQ. FT. TOTAL 2362 SQ. FT. A/C VOLUME 15120.9 CU. FT. Mf'OMW AID CLADDNC WILD LOADS BASK WM EWWFIE FOR 3 SECOND OUSTS Om3m SQUARE ZONE 160 WH WILD MO F 914M AND TYPE FOOTAGE MIN. WINDOW 10 5 34/-45 CRITERIA EXTERIOR SWING 21 5 32/-42 DR MIN. CRITERIA S.G.D. MIN. 12 5 30/-3l CRITERIA 8010 O.H.D. 56 5 32.5/-380 16010 O.H.D. 112 5 30.9/-34A SOFFIT N/A 5 31b/-35D -68.29/ IF-5829 ROOF TILE N/A 3 APPLICABLE BASIC WIND SPEED MPH = 160 (Vult) INTERNAL PRESSURE COEFFICENT = t 0.18 BLDG. CAT.=II, EXR-C, MEAN ROOF HT. = 15'-9" PRESSURES HAVE BEEN MODIFIED PER FBCR 6TH ED. (2017) R301.2.1 TO MEET TESTED ALLOWABLE OR NOMINAL WIND LOAD VALUES FROM THE PRODUCT MANUFACTURER. COMROL DAB p0 G DBL. TOP PLATE a BAR DETAIL A SCALE= 1n'=1'-0' E ARCH DTL. B SCALE: I/2 = 1'-0" i Review,d for Code Compliance Universal Engineering Sciences 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 h w w U w 0 F 4 U r7 w Q F q ti SUBDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT* 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: FLOOR PLAN 160 MPH EXP. C ARCHITECT; STATE OF FLORIDA AUG 0 6 2020 iAEL C. ANDEI AR NO 17305 08/05/20 SCALE: 1 /4"= i SHEET riI SHINGLE ROOF DECORATIVE FOAM DRAIN EQUAL TO CONTROL JOIN TO CC 8'-8' SRCa. I-IGTr 1' -m" EQUAL EQUAL )IN TO CONTROL JOINT 0 CONTROL JOINT - +/-19'-0" E3LDCs. HCsT. 12 cAr 1 _ Q •- •A 45 1 III �11 o II-1 I_I ICI III �__ _�IIII ICI ICI III- - . SCALE: 1/4 = 1'-0' v y TEXTURED FINISH NOTE: WALL FENESTRATION FLASHING AS PER FSCR R-703.4 OFF RIDGE VENT OFF RIDGE VENT IREAIR ELEVATION SCALE: 114 = I'-& TEXTURED FINISH —_-- 8'-8" SRC -� ---- — - — - — - — - — - ------- N _ --- ------— - — - - — - — - - — - Yo''0, FIN. FLR. 11R,U HT ELEVATION SCALE: 114 = I'-0' TEXTURED FINISH RIDGE VENT OFF RIDGE VENT 1�6 SRCs. IHCsT. m'-0" FIN. IN IN o -S" FRG. HCzT. ii--1'-0" 00'-0" FIN. FLR- LEFT ELEVATION SCALE: 1/4 = P-0' TEXTURED FINISH q II 4S A II II -0" FIN. FLR. oOl MODEL 1828-CALI-4EBB AREA OF ATTIC = 2450SQ. FT. NET FREE VENTILATION AREA REQUIRED - 1/ 300' REQUIRED VENTILATION AREA _ 24SO /300 - 8,17 SQ. FT. &17 = 1176SQ, IN. MIN. REQUIRED VENT] LATION = AX 1176 IN UPPER PORTION OF ATTIC = 470.4 SQ. IN'. ('BALANCE TO BE PROVIDED IN SOFFITVENTS) OFF RIDGE VENTILATION AREA = 138 SQ, IN. PER VENT (net free area) TOTAL# OF VENTS REQUIRED = 3.41 TOTAL# OF VENTS PROVIDED = 4 SOFFIT VENTILATION AREA 7 SQ. IN. PER LINEAR FT (net free area) LINEAR FEET OF SOFFIT REQUIRI 67.20 Reviewed for Code Gompudnc8 Universal Engi Oft 91 Fuentes 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 SxmDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT* 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: ELEVATION "C" 160 MPH EXP. C ARCHITECT STATE OF FLORIDA IAUG 0 0 2020 m ICHAEL C. ANDERSONAR NO T7305 PRINT 08 05 20 DATE: SCALE: 1/4"=1'- O" SHEET A2 C ELECTRICAL LEGEND SYMBOL DEFINITION NOTES --F--1 125V OUTLET 20 AMP SINGLE POLE 110V OUTLET III OUTLET 1/2 OF OUTLET WIRED TO SWITCH GFI 110V OUTLET EOLLIPED W/GRND FAUL INTERUPTER (TAMPER RESISTANT TYPE) 220V OUTLET (4) WIRE CONNECTION � � FAULT GFIGROUN OUTLET INTERRUPTER SWITCH SWITCH 3-WAY OPER Nt4 SWITCH 4-WAY OPER I—i1 WALL MOUNTED I� LIGHT CEILING LIGHT O LED CLG LIGHT O VP LED VAPOR PROOF LIGHT O VP VAPOR PROOF LIGHT ORECESSED CAN ® VENT. FAN I CrM PER SO. FT. VENT. FAN W/LIGHT I CFM PER 60. FT. VANITY LIGHT FIXTURE (SPEC'S TBD BY BUILDER) ® FLUORESCENT LIGHT 2-EVULB WRAP AROUND (RECESSED) ® 4'X2' FLUORESCENT LIGHT 2-5UL5 WRAP AROUND (SURFACE MNT.) T FLUORESCENT *FLUORESCENT p W--�--�—� 4' TRACK LIGHT 0 PANEL METER UP SMOKE DETECTOR W1HARDWIRE WALL MOUNTED BAIT. BACK-UP S!9 SMOKE DETECTOR W/ HARDWIRE GATT. BACK-UP W/ ® S/GO CARBON MONOXIDEi SMOKE DETECTOR COMBO HARDWIRE INTER -CONNECTED SHALL EVE A DISTANCE OF NOT LESS THEN 4' FROM WALL PENDANT LIGHT LIB NATURAL GA8 Il/ CUTLET . TELEPHONE JACK LUF4 WATER HEATER IGNITION SOURCE TO BE ELEVATED DISCONNECT A/ AIR. CONDITIONING TO E 21 DISCONNECT SEE ONUS. THIS SHEET TV TELEVISION JACK CEILING BOX REQUIRED O TO BE SUPPORTED IN ACCORDANCE W/ BOX J_BOX MARKED AS SUCH FOR INSPECTION CEILING Box D TO BE SUPPORTED IN IN D CEILING FANLIGHT ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION 24' INCANDESCENT LIGHT STRIP n no 36' INCANDESCENT LIGHT STRIP nnnnnnnn 0 48'INGANpESCENT LIGHT STRIP FLOOD LIGHT OPT. SECURITY KEYPAD HE P.B. PUSH-BUTTON FOR CHIMES �-- ► U55 PORT • LOCATION OF TV JACKS 4 PHONE OUTLETS t FANS TO BE VERIFIED • HOMEOWNER PRE -CONSTRUCTION MEETING. • ALL 15 t 20 AMP BRANCH CIRCUITS TO BE ARC FAULT PROTECTED PER ELECTRICAL PROVISIONS OF FBCR 6TH EDITION (2011) E NEC 210.12 2014 EDITION. • 20 AMP DEDICATED LAUNDRY CIRCUIT. GFI ■ ISLAND (NOT ON KITCHEN CIRCUIT) ' DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL ' BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF 50 CFM INTERMITTENT PER ELECTRICAL PROVISIONS OF SECTION M15013 FBCR 6T44 EDITION (2011). • LAUNDRY ROOM RECEPTACLE SHALL BE GROUND FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL ON FEEDERS • WIRING METHOD SHALL BE NON METALLIC CABLE PER ELECTRICAL PROVISIONS OF FBCR 6TH ED (2017). • ALL WORK TO COMPLY WITH ELECTRICAL PROVISIONS OF 7HE FBCR 6TH ED (2011). ALL LAMPS SHALL BE SELECTED BY BUILDER AND 15% OF LIGHTING MUST BE ENERGY EFFICIENT TYPE PER F.B.C.ENERGY CONSERVATION (RESIDENTIAL ENERGY EFFICIENCY) 2011. roth EDITION R404.1 LANAI CEILING MTD. LIGHT �•�TO BE PRE-WIR1=D LIVING ROOM I INSTALLED, \. CLG FAN PROVIDE J-BOX FOR PRE-WIRED`i' I \ OPT. FAN I \\ I GLG FAN \\J e / DINING n ! ROOM I ;n I I — � I I SWITCH�fN' — — — — — — — —J CABINET— /sue— i — — — — — — I GFI L' �__— L CsFI oP1t I r; �F"i 1 � i . \ SINK �DW I OUTLET ---U� \ \IQ KITCHEN , ( FOR DW PAN. \ RANGE I GFI n o Fw V/ W \ \ HOOD WIRE W/ OUTLET FOR U ® FUTURE MICRO I BDRM.#3 1 \\ PRE -WIRED I CLG FAN \ I I o o I I I o L II BATH #2 I IS/co 1 BDRM•#2 i / FOYER I \ F'RE-WIRED CLG FAN /f11 1 PBMFOR I I I W.LC. � I LAUN.�---n I GF I i I. L -L BDRM.#1 i PRE -WIRED CLG FAN BATH #1 I 1 VP L BDR D 4/ _ C / \`J n. O PRE -WIRED CLG FAN 'RAI -- GFI GFI PJIH4O P.B. FOR 44'AFF. 44'AFF. WI I GARAGE \ r-----� DOOR \ BOLLARD OND \ AS REQ. — \ WALL MOUNTED PER BLDG. \ LIGHT W/SWITCH IN CODE \ ATTIC \\\ 9 �I CLG. -JM KEYLESS OUTLET Q METER FIXTURE FIELD VERIFY IRRIGATION LOC. OUTLET e 48' A.F.F. ENTRY GARAGE \\-------------------- -- OPT. COACH LIGHT ELECTRICAL PLAN SCALE: 1/4' = P-0' WPPanel MAIN A PANEL. 8116 wp ctt. breaker VOLTAGE: 120 / 240 V 1 Ph MAIN: 150 Amp M.C.B FEEDER 3-#1 CuTHWN&1-#6Cu(G)in11'12"C. OR 3-#2I0ALTHWN&'I-#6Cu(G)in11/2"C. Wire Pole Bkr Description Watts Circuit circuit watts Description Skr Pole Wire #12 1 20 :Exterior Receptacle GFI for TUG 1200. 1 2 Space #12 2 20 Irrigation Pump 1000. 3 4 Space ``' 6 1 5304 A/C C.U.-1 .35 2 #8 •! 1 PANEL: 42 crtbreaker VOLTAGE: 1201240 V -1 Ph MAIN: 150 Amp M.L:O FEEDER:3- #1 Cu THWN & 1- #6 Cu (G) in 1 1!2" C. OR 3- #2/O ALTHWN & 1 #6 Cu (G) in 1 1/2" C. Bkr Description Watts I Circuit Circuit watts: Description 20 Small Appliance 1500 1 2 8000. Range 20 Iol lrrowave / Hood GFI 1800 3 4 20 Small Appliance 1600 5 6 4500 Water Heater 15 15 #6 2 35 Load subject Refrigerator 1500 7 1 8. Dining Room Lights and Receptacles AFCl 1500 9 10 1200 Disposal GFI Bath #2 GFI Receptacles 1200 11 12 1500 Distr,dasher GFI Foyer.'Hall Bed. 02 & #3/ Bath 42 Lights AFCI 900 13 14 5000 Dryer GFI Living Roam Lanai Lights AFCI 900 15 16 Kitchen and Pantry Lights & Rcpts AFCI 900 1.7 18 1500 :Washer GFI SE', & CIO AFCI. 900 19' 20 1000 Garage Door Opener:GFI Laundry 1 Bed 94 / Den AFCI 1200 21 22 1200 Garage Lights and Receptacles GFI pace AHU 1 (ter 5 KVA at 65% and factor calculations line. 23 24 900 0-mers:Suite AFCI 25 26 900 (haner's (Bathroom AFCI 27 29 28 30 900 1000 Exterior Lights and Recept GFI Irrigation controls only - 41 31 Space N 34 Space 36 Space. 37 38 Space. 5525. 3933 40 Space 16000 First 10000 watts at 100% 10000 Remaining watts at 40% '13440 Total A/C load..... T0825 Connected Load Watts Amps (watts / 240 volts) 34269 142.8 Bkr Pale Wire 50 2 #6 25 2 #10 20 1 #12 20 1 #12 30 2 #10 20 1 #12 20 1 #12 20 1 #'12 15 1. #1:.4 15 1 #14 15 20..... 1 1 #14 #12...... 1 27600 1 Load subject to demand factor calculations I line I ABBREVIATIONS: AFCI: ARC FAULT CIRCUIT: INTERRUPTER NC: NON -COINCIDENT LOAD GFI: GROUND FAULT INTERRUPTER LOAD CALCULATION IS BASED ON A/C NON -COINCIDENT LOAD I � � o 4z � i LED LIGHTING LED LIGHTING C& DOUBLE LAV. SINGLE LAV. OWNER'S BATH ® BATH 412 Ism AMP ELECTRICAL RISER NOT TO SCALE. GENERAL NOTES: A ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 6tH EDITION (201-1 LOCAL CODES, AND ALL LOCAL POWER COMPANY REGARREMENTS. B. ALL CONDUCTORS SHALL BE TYPE THHN/THWN UNLESS NOTED OTHERWISE. POWER COMPA TRANSFORMER PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY - ELECTRICAL SERVICE. PROVIDE 3 M COPPER (CU) IN 1-1/2" DIA SCHEDULE 00 PVC CONDUIT OR PROVIDE 3 02/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC CONDUIT UNLESS SERVICE IS PROVIDED BY THE ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC COMPANY PRIOR TO BID. PROVIDE 342/0 CU, THWN + I% CU IN 2' CONDUIT ORB WO AL, THWN +PIS CU IN 2' CONDUIT OR 2/0 AL. S.E.R. (CONDUIT TO TERMINATE ABOVE SOFFIT • OVERI4ANG0 COMBINATION SERVICE ISO AMP DISCONNECT SWITCH AND 120/240 VOLT M ELECTRIC METER IN I PHASE NEMIA 3R ENCLOSURE MLO PANEL 150A/2P MGB TELEPHONE SERVICE ENTRANCE EOUIPI"ENT INTERSYSTEM BONDING TERMINAL AT LOW VOLTAGE CONNECTIONS CABLE TELEVISION SERVICE ENTRANCE EQUIPMENT 1 04 CU SI-RVICE GROUND CONNECTED TO CONCRETE ENCASED EEC„ 1FM for Code ELECTRICAL pRCVISI TH ( ice EDITION 00- issal�eEngineering 5/5" PIA X 8 FT LONG COPPER CL g Unive"ces 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F w y Q U 54 O ti U O F A ti Si78DIV. 8a LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL 4EBB "1828-CALI" GARAGE SWII�TG: RIGHT PAGE: ELECTRICAL PLAN 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA AUG 0 6 2020 HAEL C. ANDEI AR NO 17305 PRINT 08 05 20 DATE: SCALE: 1/4"=1'-0" SHEET El A A - TL T Me (LE' PLUMBING PLAN SCALE: 1/4 = 77 KITCHEN SINK W/ AUTO VENT > 1-1/2" VTR I I I f (ALTERNATE RIGHT) PLUMBING RIS ER DIAGRAM VA.A.V. 2' 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 ' F N N U W ti Cy. K rJ QQ O F A F I stmDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE SWMG: RIGHT PAGE: PLUMBING PLAN 160 MPH EXP. C ARCH fTECT STATE OF FLORIDA AUG U 6 2020 MICHAEL C. ANDERSON AR NO 17305 PRINT 2005 DATE- 08 / / SCALE: 1/4"=1'-0" Reviewed for Code compliance SHEET DA Universal Engineering sc ences R—VALUE SCHEDULE FLOOR SLA5 ON GRADE R-0 EXTERIOR WALLS CMU - INT INSUL R-4.1 FRAMED WE) - ADJACENT R-13 FRAMED WD - EXTERIOR R-13 CEILING UNDER ATTIC R-30 EQUIPMENT SCHEDULE 3.0 TONS MFG G.U. A.H.U. HEAT SEER TOTAL. CAP ELECTRIC 5RKR REF LINES HVAC PLAN SCALE: 1/4 = V-0' CARRIER 25H5C53(oA•030• FX4DW5, :)0311- 5 KW 15.5 SEER 34800 208/230/11=H C.U. 35 A.H.0 35 3/4" 4 3/5" Reviewed for Code Compliance Universal Engineering Sclenws E W D3 U W F ti U h C F A Ei ti SUBDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: HVAC PLAN 160 MPH EXP. C PEER FLR. PLAN 1/2' CLG. 1/2' DRYWALL SECURE BT. PLATE TO SLAB W/ 10d MASONRY NAIL a 32' O.C. MAX FIN. FLR nVA T/10 CI AT= 188 2X4 WOOD STUDS 624' O.C. SLAB NU 11=• O I U1.J0 IIN I PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LESS THAN 2x4, WHERE SPACED NOT MORE THAN 16' O.G. OR, NOT LESS THAN 2x6, WHERE SPACED NOT MORE THAN 24" O.C. TYP. INT. WALL (NON-BRG. SCALE: 3/4' =1' -0' FIBERGLASS SHINGLES OVER "30 FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER SECTION R905.1.1 ON �,b' O.S.B. SHEATHING OR J' CDX PLYWOOD SECURED PER FASTENER SCHEDULE PRE-ENG TRUSS MTL. DRIP EDGE 2x FASCIA PER I -OI TYP. ELEVATIONS 0.+4. VENTED SOFFIT 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-O' FIN. FLR 5/8' GYPSUM Bc OR 1/2' HIGH STRENGTH CLG. BOARD DIA. SLEEVE, �) NOT CUT =BAR PEA BOND BEAM SOLID GROUT W/ (I)- S (2) COURSE DO NOT GUT THE BOND BEAM REBARS 2A'�PIPE THROUGH BOND BEAM D1 SCALE: 3/4"=1'-0° SEE ENERGY CODE FORMS FORD INSULATION R-VALUES REFERENCE STRUCTURAL J PER ELEVATION '---R-4.1 INSULATION WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS REFERENCE AA STRUCTURAL Ix2 P.T. FURRING STRIPS a 24' O.G. 8' CMU 1/2' GYP. WL. BD. WOOD BASE e, a A'O d 14. A d_a v n W/ WINDOW OPENING SCALE: 3/4' =1' -O' FIBERGLASS SHINGLES OVER 030 FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER SECTION RS05.1.1 ON IS, 0.5B. SHEATHING OR #' COX PLYWOOD SECURED PER FASTENER SCHEDULE STRUCTURAL PRE-ENG TRUSS MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS VENTED SOFFIT 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-V FIN. FLR a a . e ...a e a G . d a.. e.. a' n TYP. WALL SECTION NO OPENING NOTE: PER SECTION 905.1.1 - FOR ROOF Al l)i=FS 9.12 TC) I FSS TWAN .4-19 A IS REQUIRED. FOR ROOF SLOPES OF 4:12 OR GREATER, (1) LAYER UNDERLAYMENT IS PERMITTED BUT MUST BE PER ASTM D226 TYPE II, ASTM D 4869 TYPE IV, OR ASTM D 6151 CAULK AND SEAL LIIJE I;' PVC SLEEVE FOR WA LINE .C� I!!GYP, WL. BD. WOOD BABE ' < 4 . a.- h a . 'a; 2B GAS LINE THRU BLOCK o.� SCJU.E: Im-I'-O' FIBERGLASS SHINGLES OVER 030 FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER SECTION R905.1.1 ON I.' O.S.B. SHEATHING OR J' GDX PLYWOOD SECURED PER FASTENER SCHEDULE MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS VENTED SOFFIT PRE-ENG. GABLE TRUSS WEEP SCREED 2x P.T. SECURED PER STRUCTURAL DETAILS 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0" FIN. FLR.,. 1/2' THICK, 2 COAT - PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY GALv.STEEL L TRACK BRACKETS FASTENED TO WOOD JAMB PER PRODUCT GALV. STEEL— APPROVAL REa. VERTICAL TRACK BY MAUF. FASTENED TO TRACK BRACKETS W/ PRODUCT APPROVAL REQ. 8' CMU SEE STRUCTURAL FOR REMFORCEIMENT 2xb P.T. UJD ATTACHED TO FILL CELL AS PER PRODUCT APPROVAL REa. SEALANT BACKER ROD WEATHER STRIP MOULDING ALL AROUND (BY DOOR MANUF.) OVERHEAD DOOR BY OTHERS 3 ) GARAGE DOOR JAMBS D1 SCALE: 11/2"=1'-0" --2X4 SPF 24' O.G. MAX. SECURE W/ (2) 12d NAILS a EA. END 2x BLOCKING BETWEEN TRUSSES —PER STRUCTURAL DETAILS— �-- �- - -- � �- -- . - Y CONT. 2x RAT RUN SECURED PER STRUCTURAL DETAILS SEE ENERGY CODE FORMS FOR — INSULATION R-VALUES 5/8' GYPSUM BOARD OR 1/2' HIGH STRENGTH CLG. BOARD ' a e e. a A ". e a d a 4 ti W WINDOW OPENING R-4.1 INSULATION WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS REFERENCE STRUCTURAL Ix2 P.T. FURRING STRIPS a 24' O.G. 1/2' GYP. WL. BD. WOOD BASE a a FIBERGLASS SHINGLES OVER 030 FELT PAPER OR SYNTHETIC PRODUCT, INSTALLED PER SECTION R505.1.1 ON �6' O.S.B. SHEATHING OR J' CDX PLYWOOD SECURED PER I'-0" FASTENER SCHEDULE TYP. MTL. DRIP EDGE o.N. 2x FASCIA PER ELEVATIONS VENTED SOFFIT \---PRE-ENG. GABLE TRUSS WEEP SCREED \--2x P.T. SECURED PER STRUCTURAL DETAILS B TYP. WALL SECTION NO OPENING 1-STORY GABLE BLOCK WALL SCALE: 3/4' = I' -O' 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY CMU 0'-0' FIN. FLR. Note: WALL FENESTRATION FLASHING PER FBGR 103.4 - Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply With AAMA -111. All exterior fenestration products shall be sealed at the juncture with the Rem'"d+or Cede building wall with a sealant complyingwith AAMA 800 or ASTM C920 Class 25 Gracle INS csal En in J Universal Engineering or greater for proper joint expansion and Contraction, ASTM C1281, AAMA 612, Or other sgences approved standard as appropriate for the type Of sealant. Fluid -applied membranes used as flashing In exterior walls shall comply With AAMA 114. The flashing shall extend to the surface of the exterior Wall finish. 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W W U 0 F 4 v V3 W A F A SLTBDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT* 04321.200 041R1 MODEL: 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: DETAILS 160 MPH EXP. C ARCHrrECT- STATE OF FLORIDA AUG Q 5 2323 ►EL C. ANDEI AR NO T7305 PRINT 08 05 20 DATE: SCALE: 1 /4"=1' — 0" SHEET i TOP: 2X6 P.T. a CENTER OF DOOR HEADER SECURED W/ (1) 1/25 X 8' J-BOLT W/ 4' MIN. EMBEDMENT W/ 2' X 2' X 1/00 WASHER 4 NUT OR W/ (2) 1/2' X 8' ANCHOR BOLTS W/ 4' MIN_ EMBEDMENT W/ 2' X 2' X 1/8' WASHER 4 NUTS 0 0 SECURE 2x4 ON -- FLAT TO BILK W/ MASONRY NAILS. SIDES: 2X6 GARAGE DOOR BUCK SECURED W/ (5) 1/1' X 8' J-BOLT OR ANCHOR BOLTS, W/ 4' MIN. EMBEDMENT, W/ 2' X 2' X 1/8' WASHER 4 NUT. (1) WITHIN B' OF TOP, (1) WITHIN 8' OF THE BTM, (3) EVENLY SPACED. NOTES: ALL ANCHORS SHALL BE IN ACCORDANCE TO MANUFACTURER'S INSTALLATION INSTRUCTIONS WHERE SUCH INSTRUCTIONS ARE MORE STRINGENT GARAGE DOOR (T)BUCK ATTACHMENT "QV BCAI :1/J'.r-®' 8' CMU l4' DRYWALL IVI'X4' OR I'X2' P.T. NAILER Ix4 P.T. OR %'X4' MIN. ❑fTSECURE THRU FRAME 4 EXTEND I-Y4' INTO BLOCK W/ Wif" TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1-Y4' WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING \`DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4') DOOR JAMB TO BLOCK +3/4 OR +5/4 WINDOW TO BLOCK +3/4 OR +5/4 A SCALE: N.T.S. 2X4: SECURE TO BLOCK W/ 3i{6 TAPCONS OR (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') WITHIN 8' OF EACH END 4 IS' O.G. MAX SPACING. 2X6:® SECURE TO BLOCK W/2-%' TAPCONS(MIN. SANK SIZE .145 MIN. HEAD SIZEDYbO MIN. EMBEDMENT 1)14') — WITHIN 8' OF EACH END 4 18' O.C_ MAX SPACING. 2X8: SECURE TO BLOCK W/2-3/i6' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') WITHIN 8' OF EACH ENID 18' O.G. MAX SPACING. 8' CMU ❑ 1�" DRYWALL 1'X4' OR I'X2' P.T_ NAILER rDOOR CASING DOOR JAMB OR WINDOW .ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED )4') DOOR JAMB TO BLOCK +1-1/2" %1 WINDOW TO BLOCK +1-1/2" '' SCALE: N.T.S. 2X4= SECURE TO BLOCK W/ 3(6' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') WITHIN 8' OF EACH END 4 NOTE: STRUCTURAL 2X 15" O.G. MAX SPACING. MUST BE ON OUTSIDE 4 2X6am SECURED THROUGH SECURE TO BLOCK W/2-3/(6' NON-STRUCTURAL W6 TAPCONS TAPCON MIN. 1-Y4' (MIN. SHANK SIZE .145 EMBEDMENT INTO BLOCK. MIN. HEAD SIZE .300 8" CMU MIN. EMBEDMENT I Y4') i4' DRYWALL WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 1'X4' OR 1"X2' P.T. NAILER 2x8:CE= ❑ 3� SECURE TO BLOCK W/2-(16' we O.S.B. X 4' MIN. TAPCONS (MIN. SHANK SIZE .145 IN.SHANK DOOR CASING MIN. HEAD SIZE 300 DOOR JAMB OR WINDOW MIN. EMBEDMENT 149 ATTACH TO 2X PER WITHIN 8' OF EACH END 4 MANUFACTURES DETAILS. 18' O.C_ MAX SPACING. _/4 NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED A,) DOOR JAMB TO BLOCK +1-15 18" WINDOW TO BLOCK +1-15/ 6" C SCALE: N.T.S. 2X4:® SECURE TO BLOCK W/ 3(6' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2X6tm SECURE TO BLOCK W/2-3X6' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 _ MIN. EMBEDMENT I Y49 WITHIN 8" OF EACH END 4 18' O.G. MAX SPACING. 2X8 SECURE TO BLOCK W/2-3(6' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y49 WITHIN S" OF EACH END 4 18' O.C. MAX SPACING. NOTE: STRUCTURAL 2X MUST BE ON OUTSIDE 4 SECURED THROUGH NON-STRUCTURAL 3iS6' TAPCON MIN. I-Y4' EMBEDMENT INTO BLOCK. 8' CMU ❑ Y2' DRYWALL I'X4' OR I'X2' P.T. NAILER (—DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Ya') DOOR JAMB TO BLOCK +2 1/4" WINDOW TO BLOCK +2 1/4" SCALE: N.T.S. 2X4cm SECURE TO BLOCK W/ We,' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') NOTE: STRUCTURAL 2X WITHIN 8 OF EACH END 4 MUST BE ON OUTSIDE 4 18 O.G. MAX SPACING. 2X6cm SECURED THROUGH SECURE TO BLOCK W/2-%'NON-STRUCTURAL W6' TAPCONS TAPCON MIN. I-Y4' (MIN. SHANK SIZE .145 EMBEDMENT INTO BLOCK MIN. HEAD SIZE 300 8' CMU MIN. EMBEDMENT 1 Y4')DRYWALL WITHIN 8' OF EACH END 4 1'Ir X4' OR 1'X2' P.T. NAILER 18' O.G. MAX SPACING. —1 2X8cem SECURE TO BLOCK W/2-%' TAPCONS DOOR CASING (MIN. SHANK SIZE .145 MIN. HEAD SIZE 3110 MIN. EMBEDMENT 1 Y4') DOOR JAMB OR WINDOW WITHIN 8" OF EACH END 4 ATTACH TO 2X PER 18' O.C. MAX SPACING. MANUFACTURES DETAILS. NOTE: BRIM AS NEEDED TO FWJ-p JAPO (PO NOT P CEEP NJ DOOR JAMB TO BLOCK +T WINDOW TO BLOCK +3" E SCALE: N.TS. 2X4zm SECURE TO BLOCK W/ -(6' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') WITHIN 8' OF EACH END 4 NOTE: STRUCTURAL 2X IS" O.C. MAX SPACING. MUST BE ON OUTSIDE 4 2X6:® SECURED THROUGH SECURE TO BLOCK W/2-%' NON-STRUCTURAL -%' TAPCONS(MIN. SHANK SIZE TAPCON MIN. 1-Y4" .145 EMBEDMENT INTO BLOCK. MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') S' CMU WITHIN 8' OF EACH END 4 %�° DRYWALL 15' O.G. MAX SPACING. 2X8:® ❑ 1'X4' OR 1'X2' P.T. NAILER SECURE TO BLOCK W/2-%' 2ND 2X SECURE TO TAPCONS(MIN. SHANK STRUCTURAL MEMBER .145W/(2)l2d WITHIN 8' OF EACH MIN. HEAP SIZE 300END AATTACHT02XPER 4 V TO 8' O.G. MAX MIN. EMBEDMENT 1 Y4')DOOR CASING WITHIN 8" OF EACH ENDDOOR JAMB OR WINDOW 18' O.G. MAX SPACING. MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4') DOOR JAMB TO BLOCK +T i1 WINDOW TO BLOCK +T SCALE: N.T.S. 2X4= SECURE TO BLOCK W/Y4' TAPCONS(MIN. SHANK SIZE .145 MIN. HEAD SIZE .300 MIN. EMBEDMENT 1 Y4') NOTE: STRUCTURAL 2X WITHIN 8' OF EACH END 4 MUST BE ON OUTSIDE 4 18' O.G. MAX SPACING. SECURED THROUGH 2X6:® NON-STRg�UCTURAL 7I6" SECURE TO BLOCK W/1-1/4' TAPCON MIN. 1-Y4' TAPCONS(MIN. SHANK SIZE EMBEDMENT INTO BLOCK. .145 MIN HEAD SITE 300 MIN. EMBEDMENT 1 Y4') 8' CMU JA" DRYWALL WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 1'X4' OR I'X2" P.T. NAILER ❑2X8cm SECURE TO BLOCK W/1-1/4' 3(6' OSB. X 4' MIN. TAPCONS (MIN. SHANK SIZE .145 DOOR CASING MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') DOOR JAMB OR WINDOW WITHIN 8' OF EACH END 4 ATTACH TO 2X PER IV O.G. MAX SPACING. MANUFACTURES DETAILS. NOTE: OHM AS NEEDED TO PLLM JAMB (DO NOT E)oCEEP Y 9 DOOR JAMB TO BLOCK +3-7/16' WINDOW TO BLOCK +3-7/16" G SCALE: N.T.S. 2X4:m SECURE TO BLOCK W/Y4' TAPCONS (MIN. SHANK SIZE _145 MIN. HEAD SIZE 300 MIN. EMBEDMENT I Y4') WITHIN 8 OF EACH END 4 NOTE: STRUCTURAL 2X IS" O.G. MAX SPACING. MUST BE ON OUTSIDE 4 SECURED THROUGH H/ SECURE TO BLOCK W/1-1/4' NON-STRUCTURAL 3(16" TAPCONS TAPCON MIN. 1-Y4' (MIN. SHANK SIZE .145 EMBEDMENT INTO BLOCK. MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') 8' CMU WITHIN 8' OF EACH END 4 J§' DRYWALL 18' O.G. MAX SPACING. ❑ I'X4' OR 1'X2' P.T. NAILER 2X8 SECURE TO BLOCK W/1-1/4' ' P.T. X 4' MIN. TAPCONS OOR CASING (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 Y4') POOR JAMB OR WINDOW WITHIN 8' OF EACH END 4 TTACH TO 2X PER 18' O.C. MAX SPACING. MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED Y4') DOOR JAMB TO BLOCK +3 3/4" iu1 WINDOW TO BLOCK +3 3/4" ,, SCALE: N.TA ,:d %, code 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W W V rQ 0 F 0. U w 4 F .14 SUBDIV. 8a LOT: CREEKSIDE PHASE II LOT #41 PROJECT* 04321.200 041R1 MODEL 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: DETAILS 160 MPH EXP, C ARCHrrECT; STATE OF FLOPUDA AUG 0 6 2020 IkEL C. ANDEI AR NO V305 08/05/20 SCALE: 1 /4"= i' — �:javoajay� NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES PREFORMED CONTROL JOINT FLANGE OF CONTROL JOINTS TO BE WIRED TIED TO LATH a 9' O.G. MAX (VERT.). NOTE: DO NOT FASTEN CONTROL JOINT TO WALL EVEN IF STUD EXISTS BEYOND EXCEPT STAPLES W/ %' LEG MAY BE USED TO TEMP. SECURE CONTROL JOINT DURING INSTALLATION —� FASTENERS TO BE SPACED * 1' O.C. MAX V ERTICALLY I THICK, 3 COAT CEMENT PLASTER WRB LAYER •2, FORTIFIBER BUILDING PAPER APPROVED METAL LATH FASTENED ®1' (VERT.) OC. MAX AT SUPPORTS WRB LAYER 01, STUCCO WRAP WOOD SHEATHING OR 1/16' ZIP SHEATHING SYSTEM(IINSTALLED PER n'' TO ,° LATH SHALL NOT GAP MIN' BE CONTINUOUS V TO e• m O a THROUGH CONTROL MN. JOINTS BUT SHALL MIN. BE STOPPED AND TIED AT EACH SIDE. PER ASTM CI063 PROVIDE 2X4 BLOCKING 71014 PLACED FLAT MAX. 6' TO 8' FROM CONTROL JOINT WHEN NOTE: CONTROL JOINT FALLS ON L FASTENERS FOR LATH TO BE NAILS OR STRUCTURAL STUD STAPLES IN COMPLIANCE W/ ASTM C1063 2. WIRE TIES TO BE (NO. 18) 0.0415' WIRE / 3. BLOCKING SHOWN MAY BE IN ADDITION \ TO WALL STUDS REQUIRED PER PLAN / O"M" TYPE CONTROL JOINT O1. FOLD INWARD • PT. A O1. FOLD INWARD . PT. A 2. CREASE • PT. 15 OI. FOLD INWARD • ® I. FOLD INLAID • PT. A PT. A 7. CREASE . Pi. B s. GREASE • PT. B 3. CIREABE • Pr. C 3. CREASE a PT. C 4. FOLD PT. C OVER PT. B TILL PT. C TOUCHES SIOTTOM FLANGE t >E ® ®FOLD • Tt•. „ SHINGLE ROOFING—� DRIP EDGE: OVERLAP 3'. EXTEND Ia' BELOW SHEATHING, MEGHANICALLY FASTEN 4' OG, MAX FLANGE WATER TIGHT SEAL. FOLP, QQ NGM CUT. i' THICK, 3 COAT CEMENT PLASTER (FRAME), 14' 1 COAT CEMENT PLASTER (CFAs) W4RIB LAYER 02, FOWIF15ER BUILDING PAPER(FRAME ONLY) WRB LAYER h, STUCCO WRAP (FRAM ONLY) LAP LAYERS OF BUILDING WRAP OVER NAILING FLANGE, STOP WI® APPROX 1 JP ABOVE 81414GLES (FRAME ONLY) i� FRAME OR GMU FASCIA WRAP Sx8 WALL FLASHING KICK -OUT FLASHING (SEE DETAIL) NOTE: APPROVED BUILDING: WRAP SHALL BE LAPPED A MINIMUM OF 6' s VERTICAL LAPS (ROLL ENDS) 4 6' • HORIZONTAL LAPS. ALL SEAMS NEED TO M TAPED WITH FORTIBER SHEATHING TAPE II l I" MIN. LAP Is METAL LATH 6-'MIN PAPER LAP BELOW- ONLY r / WRB LAYER 02, FORTIFIBER., BUILDING: PAPER SCALE. 1 1/2'.1'-0' ® KIC KO UT DETAIL WATER TIGHT REAL (BEND OR BOLDER Do NOT CUT) LATH VERTICAL LAP TO BE 1' METAL LATH WRB LAYER 01, STUCCO WRAP VERTICAL LATH & PAPER DETAIL NOTE: SIDE LAPS OF METAL PLASTER BASES SHALL BE SECURED TO FRAMING MEMBERS. THEY SHALL BE TIED BETWEEN SUPPORTS WITH 0.0415-IN. (121-MM) WIRE AT INTERVALS NOT MORE THAN W (229-MM). AS PER ASTM CIO63 FOR PAIR OF TEARS IN WRB LAYERS, TEARS MAY BE PATCHED W/WOUSE WRAP TAPE PER MANUF. SPEC. OR PEEL 4 STICK NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WOOD STUD° SHEATHING - OR 7/16' ZIP SHEATHING SYSTEM (INSTALLED PER MANUF.SPECSJ BUILDING — PAPER NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES STUCCO i' THICK, 3 COAT CEMENT PLASTER METAL LATH WRB LAYER 02, FORTIFIBER BUILDING PAPER WRB LAYER 01, STUCCO WRAP WOOD SHEATHING OR 1/16' ZIP SHEATHNG SYSTEM (INSTALLED PER m*Lr-. SPECS.) LAP LATH LAP ® PAPER HORIZONTAL LATH & PAPER DETAIL 7/16' ZIP SHEATHING SYSTEM ( INSTALLED PER MANUF. SPECS.) OR WOOD SHEATHING OR CMU WRB LATER 01, STUCCO WRAP (FRAME ONLY) e" THICK, 3 COAT CEMENT PLASTER(FRAME), 1/2" 2 COAT CEMENT PLASTER (CMU) METAL LATH (FRAME ONLY) LAP WRB 4 TAPE OVER ROOF/WALL SCREED 5'X5" "L" TYPE CONTINUOUS GALV. METAL FLASHING (NAIL TO ROOF DECK, NOT WALL SHEATHING:) CAP SHINGLE - DO NOT NAIL, INSTALL WITH ROOF CEMENT ROOF PER ELEVATIONS 5 " L" FLASHING N.T.S. 4'x4' SELF -ADHERING MEMBRANE FLASHING (COMPATIBLE W/ HOUSE WRAP MATERIAL) OVER APPROVED HOUSE WRAP. FLASHING TO EXTEND ONTO PIPE Is OR LESS PIPE PENETRATION .?}`.. situ>).... CUT AND OVERLAP ONE 51DE OF / SELF -ADHERING MEMBRANE l FLASHING .STEP 01 INSTALL FASTENERS (CLIPS, STRAPS, STAPLES) AS REQUIRED TO SECURE PIPE/ WIRE TO FRAMING SECTION NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES 6'x6' SELF -ADHERING MEMBRANE FLASHING (COMPATIBLE W/ HOUSE WRAP MATERIAL) OVER 4'x4' SELF -ADHERING MEMBRANE FLASHING OVER APPROVED HOUSE WRAP - FLASHING TO EXTEND ONTO PIPE CUT AND OVERLAP ONE SIDE OF STEP 02 SELF - ADHERING MEMBRANE NG WRB LAYER 01, STUCCO WRAP WRB LAYER V, FORTINBER BUILDING PAPER METAL LATH Wxb' SELF -ADHERING MEMBRANE FLASHING OVER 4'x4' SELF -ADHERING MEMBRANE FLASHING OVER APPROVED HOUSE WRAP. FLASHING TO EXTEND ONTO PIPE 4'x4' SELF -ADHERING MEMBRANE FLASHING OVER APPROVED HOUSE WRAP, FLASHING TO EXTEND ONTO PIPE %' CONT. BEAD OF SEALANT INSTALL APPROVED HOUSEWRAP AIR INFILTRATION BARRIER OVER SHEATHING ::_ELASTOMERIC COATING OVER STUCCO/ C.V. FINISH (SEE TYP WALL SECTION) f FENETRATf ON N.T.5. PER SECTION R703.7 Ex4xbr lad lM and t1h3e91(fq Exterior use of portland cement plaster shall comply with the application requirements of ASTM C 926-12A. Installation of exterior lathing and framing shall comply with ASTM C 1063-12A. TA L DRAINAGE PLANE (UJRB LAYER *11, STUCCO WRAF) WRE3 LAYER #2 (FOFT11=18ER 5U1LD INCH FAFER) 1'1ET)4L LATH 1`01 E ...... X X X X STUCCO :.. '<.. r; a..:. . WOOD SHEATHING OR 1/16' ZIP SHEATHING SYSTEM ( INSTALLED PER MANUR SPECS.) SELF-ADHESIVE FLASHING - - - - - - NOTE: 1`'1ETAL LATH: LATH TO 5E PER SECTION )4,57-1 C-841—OS/ 1 11N. 2.5 L 'Reviewedtor Cede PER SQ. Y,4RD (UTILITY OR NO1"1IN)4 Un versa)Englin- ^9 Sciences LATH DOES NOT 1"1EET Sfi=EC11=ICATIONS) 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F N C4111U W O ti 0. U 4 F A F ti SUBDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT* 04321.200 041R1 MODEL: 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: WALL ASSEMBLY DETAILS ARCHRECT. STATE OF FLORIDA %v 0 6 2029 MICHAEL C. ANDERSON AR NO 17305 J PRINT 206 05 DATE: 0/ / SCALE: 1/4"=1'-0" SHEET WAI NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES BACKER ROD BACKER ROD WRB LAYER 01, STUCCO WRAP VE INSTALL 6' SELF -ADHERING MEMBRANE FLASHING OVER TOP, SIDES) AND BOTTOM FLANGES OF NON -MOVABLE FRAME OF THE EXHAUST. SEQUENCE OF FLASHING TO BE: L BOTTOM. 2. SIDES, 3. TOP VENT CAP IS TO BE SET IN RED OF SEALANT AT TOP AND SIDES ONLY. SEALANT IS TO BE TOOLED SO AS TO DEFLECT WATER AWAY FROM JOINTS. E-Z BEAD ALL AROUND VENT -APPLY SEALANT ALL JOINTS AND INTERSECTIONS APPLY SEALANT AT PERIMETER OF NON -MOVABLE FRAME AND STUCCO ON ALL SIDES, Y4' CAULKING a JOINT ALL AROUND PER SECTION R703.7 Exterlor lathing and plasteHng Exterior use of portland cement plaster shall comply with the application requirements of ASTM C 926-12A. Installation of exterior lathing and framing shall comply with ASTM C 1063-12A. HOODED VENT jo THICK, 3 COAT CEMENT PLASTER METAL LATH WRB LAYER e2, FORTIFIBER BUILDING PAPER WOOD SHEATHING LEGEND { RAME DRAINACzE PLANE (WRB LATER #1, STUCCO WRAP) WRB LATER 02 (FORTIFIBER - - - - - - - - BUILDING PAPER) METAL LATH x-x-x-x STUCCO WOOD SHEATHINCz OR 7/16" ZIP SHEATHING SYSTEM ( INSTALLED PER MANUF. SPECS.) SELF-ADHESIVE FLASHING - - - - - NOTE: METAL LATH: LATH TO 5E PER SECTION R-103.7.1 / AST-1 G-047-09, MIN. 2.5 LSS. PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFIGATIONS) ELEC_ METEF VERIFY LO STUCCO FINISH 6" SELF ADHESIVE OVER TOP 4 SIDES SELF FLASHING UNIT PREMANUF. DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT TOP 4 SIDES �B DRYER VENT (BLOCK BUILDING PAPER OVER 'QUICK FLASH' PIPE THROUGH — WALL t\ 6" SELF ADHESIVE — FLASHING (INSTALL PER MANUF. SPECS.) BUILDING PAPER — UNDER 'QUICK FLASH' 1- - / NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES (N)VENT PENETRATION 1i SCALE: N.T.S. STUCCO SCRATCH COAT 4 1 COAT OF PAINT W/BACK- ROLL PRIOR TO ELEC. METER INSTALLATION -ELEC. METER FIELD VERIFY LOCATION APPLY STUCCO SCRATCH COAT AND ONE (1) LAYER OF PAINT PRIOR TO INSTALLING ELEC. METER CAVITY TO BE FILLED WITH RIGID POLYMERIC ISOCYANOTE-POLYBLEND FOAM .°�o� Ar c-ri 1171-_11 ')R SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEG. WIRE PENETRATES u.. O SCRATCH COAT LARGER THAN THE ELEC. METER CAN OR METER CAN COMBO OR METER CAN AND DISCONNECT O ELECTRICAL CONDUIT PENETRATION CUT OPENING IN APPROVED HOUSEWRAP FoR Box INSTALLATION WRB LAYER M, STUCCO WRAP WOOD SHEATHING APPROVED HOUSEWRAP BELOW CUT SUCH THA NO MEMBRANE ENTERS BOX, APPLY TO FAc EDGE APPLY E-Z OVER 60 MI GRADE '0' FELT-PROVII SEALANT AT JOINTS AND INTERSECTIC I/I6' ZIP SHEATHING SYSTEM I-LINSTALLED PER MANUF. SPECS.) OR WOOD SHEATHING WRB LAYER "I, STUCCO WRAP WRB LAYER i'2, FORTIFIBER BUILDING PAPER METAL LATH WOODFINISTEXTURED WO CONST FASTEN TO WOOD STRUCTURAL MEMBER • In OL. MAX 8' CMU Ye' TO Y2' MID -WALL WEEP SCREED EJ W WIDE STRIP SELF ADHESIVE FLASHING, CLEAN MASONRY BEFORE APPLYING V FINISH a MASONRY 7B HORIZONTAL WEEP SCREED (FRAME TO BLOCK NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES WRB LAYER "I, STUCCO WRAP CUT 'X" INTO SELF -ADHERING MEMBRANE FLASHING APPLY SELF -ADHERING MEMBRANE FLASHING OVER BOX AND OVER APPROVED WRB LAYER el STEF '*I APPLY 60 MIN - GRADE "D' FELT OVER SELF -ADHERING FLASHING OVER APROVED HOUSEWRAP 5 T E #� OV STEP *'2 WRB LAYER 01, STUCCO WRAP SELF -ADHERING MEMBRANE FLASHING WRB LAYER e2, FORTIFIBER BUILDING PAPER ST f= # ELASTOMERIC COATING OVER STUCCO/ C.V. FINISH (SEE TYPICAL WALL SECTION) METAL LATH 5 7 E 5T E f #(o ELECTRICAL R E C E P T AC Ide CE Reviewed for Co Compliance Universal Enyin ft scler,ces 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F k U w O F 0. U W A F A sysDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL: EL. "1828-CALI" GARAGE SWING: RIGHT PAGE: WALL ASSEMBLY DETAILS ARCHFFECT- STATE OF FLORIDA AUG 0 6 2020 IAEL C. ANDEI AR NO 17305 ras,aa� + DATE: 08 05 20 SCALE: 1/4"=f-0" SHEET WA2 L E G E LDN -T DRAINAGE PLANE (WR5 LATER 01, STUCCO UJRAP) ILRB LAYER 02 C�=ORTIF:IBEX' 5UILDING RAPER) METAL LATH x x x x STUCCO _ UJOOD SHEATHING OR 1/16' ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) SELF-ADHESIVE FLASHING - — — — — 2 1 /2 ° 1 Apt CORNER BEAD CORNER BEAD (FASTENER 4 SPACING a -1" O.G.) NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES CMU V THICK, 3 COAT CEMENT PLASTER APPLIED DIRECTLY TO MASONRY @) BLOCK Reviewed for Code Compliance Universal EnyeieerNq Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W U W O F a U4 4 q SVBDIV. & LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL: 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: WALL ASSEMBLY DETAILS ARCHITECT. STATE OF FLORIDA AUG'a 5 i.KO MICHAEL C. ANDERSON L AR NO 17305 i PRINT 20 08 05 DATE: / / SCALE: 1/4"=1'-0" SHEET METAL FASCIA LURAP 2XCa SU5 SAND 2x& SUB-BANID W/1 "x4" NOTCH a END, WRAPPED IN PEEL 4 STICK DRIP EDGE -1/8" TEXTURED FINISH a WOOD 1/2" TEXTURED FINISH a CMU I� I� I, I � 1 � i METAL FASCIA 1 WRAP YS" FROM STUCCO, 1" FROM WOOD WALL EXTERIOR WALL (FRAME OR CMU) \� NOTE: NOTCH FOR 2X(o REMOVED ,EYOND) OFF WALL :CO) > FINISH :TURF D W/1 "x4" NOTCH a IN PEEL 4 STICK WRAP I' OFF IB BAND 2 " L '/8' TEXTURED FINISH a WOOD, 1/2' TEXTURED FINISH a CMU METAL LATH THING, LURE LAYER 01, STUCCO LURAP (FRAME ONLY) URB LAYER *2, FORTIFI5ER 5UILDINCs PAPER (FRAME ONLY) ROOFING CEMENT DRIP EDGE METAL KICK OUT NOTE: IF ZIP SHEATHING S`I'STEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PRE-ENG'D TRUSS TO BE CUT a WALL LINE TO AVOID CONTACT W/TEXTURED FINISH 2 "x4 "x4' - O' SCABBED TO TRUSS W/126 NAILS 6'-S" O.C. MAX. 2x SUS -SAND W/lY"x4" NOTCH a END METAL FASCIA WRAP DRIP EDGE EXTERIOR WALL (FRAME OR CMU) SUB BAND DETAIL C@ WALL SUB BAND DETAIL (9WALL WW./KICK-OUT FRAME OR CMU FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/lY"x4" NOTCH a END, WRAPPED IN PEEL 4 STICK *ROOF CEMENT a ROOF EDGE OMITTED FOR CLARITY FRAME OR CMU WALL KICK -OUT FLASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND WIV2Hx4" NOTCH a END, WRAPPED IN PEEL 8 STICK *ROOF CEMENT a ROOF EDGE OMITTED FOR CLARITY Reviewed for Cade compilame Universal E.nglneerinp ID Sciences 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 ti N w U F R. DI w 4 F A x SVSDIV. 8a LOT: CREEKSIDE PHASE II LOT #41 PROJECT* 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: WALL ASSEMBLY DETAILS: SUB -BAND ARCHrrECT: STATE OF FLORlDA iAEL C. ANDS AR NO 17305 AT' D08/05/20 DATE:: SCALE: 1/4"=1'-0" SHEET WA6 39'-8" 11'_b 28 -8" 4 9,_8, 9,_6, 15,_1,0" FM-12X12 1 FM-12X18— — I� 1.1 N o N 4" CONC. o co N ao I. W LL SLAB I� a io O w u- cJn a *-3 1/2 LF-24X24 1,-D�� 1 101 D„ 10 1.1 1 FM-12X18 EXTEND 1.1 SLAB 1 1/2„ oI . I 01011 — T o / 3 \ �z �_ O a 1 1.1 I• GO t X CN LL u- I . �x N Lu- Ln oI �El ❑ 4" PVC 1 CHASE TE-1 I I N I 4" CONC. 0 SLAB . °O *51/2 4" 2'-8' 17'-8 0'-0" C TOP OF m 5 S-0" SLAB 1.1 qo 3' 6"bo I N N a I 00 I_I NI (V LU LLI C?O J N I aI I 1 EXTEND 1 ---- SLAB 1 1/2" 2 v 14" CONC 1 �1': ao FM-12X18 1.1 SLAB a wL N x 0 3 1/2 O a. I' N I 4' I Li ---- C) 2 *-71/2 1.1 L FM-12X18 — — — — — 1.1 — FMC-12X18 v — — FM-12X18 — — — — — — FMC-12X18 — 10 0 4'_4" 0 I 4 1.1 2'_8 10'_2" 3 16,_D, 4 1.1 2'-8" N. 21'_4" 14'-0„ 39'-8' "0U.N.D1,1TICON PLAN SCALE: 1/4" = T-0" FOUNDATION NOTES 1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR COMPACTING REQUIREMENTS. 2. TOP OF FINISHED SLAB SHALL BE+-0'-0". 3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 4. REFERENCE ELEVATION +4-0", SEE SURVEY PLOT FOR NAVD. 5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: PROVIDE 1/2" FELT PAPER AT THE JOINT. 7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL DRAWINGS. 8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING, 9, WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS AND WITH THE MANUFACTURES SPECIFICATIONS 10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. 11.OINDICATEb#5 BAR, MINDICATES #6 BAR,■INDICATES #7 BAR VERTICAL REINFORCINGBAR IN CELLS FILLED WITH GROUT ENDS OF REINF: BARS SHALL BE HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 90° HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS, 12. SPLICES IN; REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = 30", #6 =36"), AND REINFORCING SHALL BE CONTINUOUS. 13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS BEEN DELETED UNLESS NOTED OTHERWISE. 14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS OTHERWISE NOTED IN THE PLAN, ONE REINFORCING BAR SHALL BE: A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS 15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C:L 530-13/ASCE 5-13, BUILDING .CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5-13, USING: F'm = 1,500 PSI, TYPE "M" OR"S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN RUNNING BOND. 16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER j OF SLAB SUPPORTED T-0" O/C MAX !SEE PLAN FOR WWM SIZE. INSPECTOR NOTE: 1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING CODE, RESIDENTIAL, 6th EDITION SLAB SCHEDULE: SLAB THICKNESS REINF. REMARKS 6x6 W1.4xW1.4 OVER GENERAL 3 1/2" 6 MIL VAPOR' COMPACTED FILL BARRIER FOOTING SCHEDULE PROVIDE CORNER BARS', SAME SIZE QUANTITY AS BARS IN FOUNDATION, WITH 30" LEG EACH WAY. MARK WIDTH LENGTH THICKNESS BOTTOM REINF. TOP REINF. T.O.F. SHORT LONG TE-1 8" SEE PLAN 101, (2) # 's (+)0"_0" + p^_0" FM-12x12 12" CONTINUOUS 12" (2) #5's FM-12x18 12" CONTINUOUS 18" (2) #5's (+)0'-0" 95 RN i IJRB VARIES FM-16x18 16" CONTINUOUS 18" (2) #5's FMC-12x18 12" CONTINUOUS 18" (2) #5's F-24x24 24„ 1 24" 1 12" s s SECURE STRAP TO A/C SIMPSON WB GONG. W/ UNIT ROLL STRAP C2)- OR EQUAL o CONIS TAP --CONS EACH CORNER OP UNIT CONIC. SECURE STRAP TO SLAB UNITS W/ (2) 08A 1/4 SHT MTL SCREWS A/C CONNECTION TO PAD DETAIL Reviewed for Code Compliance Universal Engines" Sciences 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3501 www.abdesigngroup.com AA #: 0003325 F W v W 0 F 0. U W 4 F A ti SUBDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: FOUNDATION PLAN 160 MPH EXP, C ARCHrrECT-- STATE OF FLORIDA i AUG 0 6 2020 MICHAEL C. ANDERSON AR NO T7305 DATE 08/05/20 SCALE: 1/4"=1' — 0" SHEET S 1 Z STEEL REINFORCING IN GROUTED Q a CELL SEE PLAN FOR SIZE AND } SPACING REQUIREMENTS mw V J U Z 8" CMU WALL co co + 0'- . ° TOP OF.SLA ' a e a. ' SEE SLAB SCHEDULE EXT. PORCH SLAB d �. W° 4" CHAMFER (1-STORY) / 1/2" ISOLATION .., 6" CHAMFER (2-STORY) JOINT (WHERE APPLICABLE) Z ' SEE SCHEDULE FOR WxD, BAR SIZE iv AND BAR QUANTITY BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" r�EXTERIOR MONO -FOOTING BOLLARD LAP P PLATE A MIN. .OF 48" AND N W/ 16d COMMON NAILS 2- WS, 4" O!C BTM. LAP TO OC ROVER STUD 2x4 OR 2x6 WOO EARING - WALL W/ SYP Na 2 UDS SEE PLANS FOR SPACIN INGLE BTM. PLATE TO BE PT. PROVIDE DBL.TOP PLAT +_ U._U.. TOP OF SCALE: 3/4"=V-0 2" CAPPED GALVANIZED PIPE W/FLANGE @ BASE cM SECURE FLANGE TO SLAB W/(4) 1/4" X 2 114" TAPCONS I SCALE: 3/4"=1'-0" VERIFY HEIGHT OF WALL W/ PLAN PROVIDE BLOCK G RE B . PLATE TO LA ! d MASONRY NAIL TAGGERED. IONAL METAL NECTORS NOT QUIRED WHEN NO UPLIFT IS PRESENT. -SEE SLAB SCHEDULE I \10OD HEDULE ,l BAR SIZE -QUANTITY 3" 9 INT OR FOUNDWALL SCALE: 3/4"=1'-0" (NO LIFT) I _Z STEELREINFORCING IN GROUTED 4 d CELL SEE PLAN FOR SIZE AND F SPACING REQUIREMENTS m w (� a EL p ' 8" CMU WALL o Z TOP OF SLAB SEE SLAB SCHEDULE TOP OF GARAGE T EXT. PORCH SLAB 4" CHAMFER (I -STORY) W/ 1/2" ISOLATION ' 6" CHAMFER (2-STORY) JOINT (WHERE EE SCHEDULE APPLICABLE) '', Z_ NsQ' FOR WXD, BAR SIZE AND BAR QUANTITY 04 (DEXTERIOR MONO -FOOTING @ GARAGE SCALE S/4"=1'-0" w Ja o I to NEW REINF. BAR O 0- SECURED W/ 2- PART a ¢ I EPDXY. MIN. EMBED J Q 8', UNO < — � FOLLOW ALL MANF. m Q I SPECIFICATIONS FOR USE AND 00 PREPARATION OF Z w HOLE. J o p 4" CHAMFER (1STORY) 6" CHAMFER (2-STORY) ADDING AR TO MONOLIT IC FOUNDATION 6 SCALE: 3/4"=V-0" Q o }a} m Lu 00 J r o- IY In 0 STEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND SPACING REQUIREMENTS 8" CMU WF�L CD SEE SLAB SCHEDULE g 'ISOLATED COLUMN PAD oo d a• CENTERED UNDER WALL AND 00 — .4 . POURED MONOLITHICALLY WITH FOUNDATION AND SLAB SEE SCH ULE FOR WxD, BA SIZE AND BAR QUAN TY MBINED EXTERIO MONO- OOTING AND COL. P 30" MIN. EACH WAY FOOTING b P > M erg 6 . e s sv :L FM ♦ . CORNER BARS, SAME SIZE AS LARGER BAR P el. IN FOUNDATION WITH 30' LEG EACH ° WAY AT ALL CHANGES IN DIRECTIONS . I .s . � SO THAT THE STEEL REINF 1S CONTlNUOUS MATCH AMOUNT OF CONTINUOUS BARS " CONTINUOUS STEEL MONOLITHIC KFOOTING REINFORCEMENT SEE SCHEDULE ANSITIONS ARE MADE FROM FOUNDATIONS HAVING DIFFERENT NUMBER OF CONTINUOUS BARS PROVIDE THE LEAST NUMBER OF BARS (ie. 2 TO 3, PROVIDE 2 BARS), LINO MONOLITHIC FOUNDATION CORNER BARS DETAIL P TOP PLATE A MIN. OF 48 A NAIL W/ 16d COMMON NAIL 2-ROWS, 4" O/C BTM. LAP TO CCUR OVER STUD 2x4 OR 2x6 D BEARING - WALLW/SYP No 2i STUDS SEE PL S FOR SPACING. SINGLE BT PLATE TO BE PT. PROVIDE DBL: OP PLATE SIMPSON SPH4 OR SPH6 — BTM AND TOP PLATE ANCHORS W/ 10d x 1 1/2"_ COMMON NAILS FILL ALL HOLES, DO NOT USE 10d x T' +- 0 0" SCALE` 3/4"=1'-0 /W/PLAN HT PLANO NGATE TO SLAB W/ ANCHOR W/2" HIGH STRENGTH BED. MIN. 0 16" OC ESLAB SCHEDULE TOP OF SLAB 'a EQ. EQ. SEE SCH ULE FOR WxD, BA IZE AND BAR QUANT INTERIOR CURB FOUNDATION WOOD WA SCALE:3/4"=1'-9' (W/ UPLI + POURED LINTEL CONT. (TYP.) 8" CMU FILLED CELL (TYPJ SLA3 u 2X WALL FRAMING :' •; 1/2" DIA. SIMPSON STB2 BOLTS 5" MINIMUM EMBEDMENT INTO GROUTED CELL, 4" FROM ENDS AND 16" O.C. VERTICALLY MAX INTERIOR FRAME BRIG WALL TO BLOCK WALL CONNECTION SCALE: 3/4"=1'-0" RECESS AROUND GARAGE DOOR OPENING SCALE: 3/4 LAP TOP PLATE A MIN. OF 48 AND NAIL W/ 16d COMMON FOR INRY ISET EV: NAILS, 2-ROWS, 4" O/C BTM. I I VERIFY HEIGHT LAP TO OCCUR OVER STUD J OF WALL W/ PLAN 2x4 OR 2x6 WOOD BEARING PROVIDE BLOCKING WALL W SYP No 2 STUDS SEE PLANS FOR SPACING. SINGLE BTM. PLATE TO BE PT. PROVIDE DBL. TOP PLATE SECURE BT. PLATE TO +_ 0'-0" TOP OF SLAB SLAB W/10d MASONRY NAIL 16" O/C STAGGERED. ADDITIONAL METAL CONNECTORS NOT REQUIRED WHEN NO W UPLIFT IS PRESENT. � SEE SLAB SCHEDULE Q \. rd .' e 4. p�`� _mod• . d : a . • 40 ° EQ. EQ. SEE SCHEDULE FOR WxD, BAR SIZE AND BAR QUANTITY INTERIOR CURB FOUNDATION WOOD WALL SCALE:3/4"=1'-0" (NO UPLIFT) Reviewed for Code Compliance Universal Engme8ft Sciences 2194 H WY AJ A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.a bdeskk igngrow p.com AA #: 0003325 r I hi y U D 11-3 0 FF v Q F A •yLi SUBDIV. & LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: DETAILS 160 MPH EXP. C ARCHM CT STATE OF FLORIDA AUG 0 6 2020 MICHAEL C. ANDERSON AR NO 17305 J PRINT DATE: 08 05 20 SCALE: 1 /4"=1' — 0" SHEET S1. 1 A N N o— IL'JI IL•JI 2'-4" DOWEL PLAN SCALE: 1/4" = T-0" 25'-10" 18'-10" 14'-8" 3'-0" 01 El e o v m 0 b N O N El N C9 in C9 17 19'-0. c iO LO 0 N co Reviewed for Code Compliance Universe] Engmeedrp sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W h U W ti 0. h Q F A E- ti SUBDIV 8e LOOT: CREEKSIDE PHASE II' LOT #41 PROJECT# 04321.200 041R1 ]MODEL: 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: DOWEL PLAN 160 MPH EXP. C ARCHrrECT- STATE OF FLORIDA ICHAEL �6 &ERSC AR NO 17305 PRINT 08 05 20 DATE- / / SCALE: 1/4"=1' — 0" SHEET S1. 2 TIE VERTICAL REBAR TO HORIZONTAL REBAR W/ 10" HOOK - GROUTED BOND BEAM ARIES PER ELEV. e a: d d d Q. N e r- al. d d C a d J e � . Q Q co e a IIrO CLEAN OUT REQUIRED FOR INSPECTION 0'-0" FIN. FLR _ a TIE VERTICAL REBAR TO HORIZONTAL REBAR W/ 10" HOOK d' 4 Z Lu —w > O O HORIZONTALIVERTICAL REINFORCING SCALE: 314"=1'-0" EXT. PORCH SLAB W/ 1/2" ISOLATION JOINT (WHERE APPLICABLE) 6" PVC CHASE THRU FOOTING BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" / I la .1 -A_ . J Z a III III — STEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND SPACING REQUIREMENTS 8" CMU WALL \—SEE SLAB SCHEDULE 4 4" CHAMFER (1-STORY) 6" CHAMFER (2-STORY) MATCH STEEL REINFORCEMENT PER SCHEDULE —SEE SCHEDULE FOR WxD BAR SIZE BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" z w �o U AND BAR QUANTITY PVC CHASE 4 THRU FOOTING SCALE: 3/4"=1'-0" REINFORCEMENT PER SCHEDULE NG #5 BARS [E] ` CMU UNIT DIMENSIONS ARE NOMINAL SIZES (D_MMASONRY SYMBOLS SCALE: 3/4"=T-0" Lr+ Reviewed for Code Compliance Universal fln9Meenn9 Sciences 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F N U rQ �V O F 0. U W 4 F C ti SUBDIV. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL: 4EBB "1828—CALI" GARAGE SVIMG: RIGHT PAGE: DETAILS 160 MPH EXP. C ARCHrrECT. STATE OF FLORIDA AUG 0 S 2020 MICHAEL C. ANDERSON AR NO 17305 J DATE 08/05/20 SCALE: 1/4"=V-0" SHEET S10 2A FRAMING NOTES 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 11/2" HDG NAILS. CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W/ (8) 10d x 1 1/2" HDG NAILS, WOOD TO WOOD: SIMPSON H10A OR LGT2 W/ 10d x 1 1/2" HDG NAILS, FILLALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS 7. LINTELS SHALL HAVE 4' NOMINAL BEARING (4 ). 8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED*UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEWAND APPROVAL. 9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES, SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177 x 2 7/8" LONG, WITH WASHER @ 16" O.C. 10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS: 12. ALL ELEVATIONS ARE REFERENCED FROM U-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. BEAM SCHEDULE INDICATES OPENING BELOW / T.O.B. = TOP OF BEAM / B:O.L. = BOTTOM OF LINTEL / T.O.A.= TOP OF ARCH I T.O.S = TOP OF SLAB ABBREVIATIONS E.E.= EACH END, O/C = ON CENTER; F:E.S. = FROM EACH SUPPORT, T.O. = THROUGHOUT MARK DESCRIPTION f'c (psi) SIZE SIIZH' REINFORCEMENT STIRRUPS REMARKS BTM. TOP MID SIZE SPACING BB1 MASONRY 3000 8x8 — (1) #5 — N/A — GROUTED SOLID "CAST-CRETE" SAFE LOAQ TABLES SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS SAFE LATERAL 8" PRECAST & PRESTRESSED'',U-LINTELS LOADS FOR SAFE UPLIFT LOADS FOR 8' PRECAST & PRESTRESSED U-LINTELS SAFE LOAD - POUNDS PER LINEAR FOOT C SArEEL OAD SAFE LOAD - POUNDS PER LINEAR FOOT TYPE LENGTH 8U8 eFa.ae BF12-0B SPISM NPON OF240B M28-0 SOB TYPESUS LENGTH S RCMU TYPE LENGTH &S1T W124T BF164T 6F2D4T OF24-1t eRtstt ePaaTT eF67B OR246 W167B 8F10.ts aF24.1B fill NIZIB wei amiar /F1 u OF20•sr 8F24i .2r 9F/am wwu 3,4, (42� PRECAST 2231 NO 3719 6163 OW am 9502 10051 �� (42') PRECAST 1025 1024 1598 3�' (42� PRECAST 7800 2855 9624 4304 am 0132 70M Sall4m6 6113 7547 e974 10394 11e09 tree wee SB24 4984 Sae9 0182 7001 *V (48') PRECAST 1908 =I 275t 9820 4e00 am 70H ato7 4,4, (48') PRECAST 706 783 13M *W (4S� PRECAST 1383 2ao6 amU15 4670 eaw m70 2898 40M $113 7547 6e74 10894 71me 1303 21115 8111101 3815 4670 eaw em 4'41r 64 PRECAST (' 1599 1069 2110 2931 37m 415M 6400 am , 4$' (547 PRECAST 5921 591 1078 , 4$ F✓84' PRECAST 1207 2040 2707 8875 404a 4711 s819 21M 4375 6113 75470l e672 70484 time 1207 2040 2M7 8975 4043 47" Sa79 S4' (847 PRECAST 1Z77 1340 "a7Be9 25M 3129 HIN 42W Ste• (B19 PRECAST 411 411 74b OW(e49 PRECAST 1016 171$i9 22Mtq 268a 8909 3961 4622 tees a9m NO 7547M 978s1u 10127 1010 1715 2276 20e 9989 3961 41W 5-10' (70') PRECAST 10� 1105 1173 1004 2000 2540 a009 3470 5-10' (70� PRECAST 340 3� 818 5-10' (70') PRECAST we we 1587aq 2110 3407 3010 4138 " 1451 202 43M 7100M eoaepq 7181M 8=111% 1567 211e0 203 3107 30D 413E 94r (78) PRECAST we 1298 2177 34M 3031 37OF 430 587 V4r (759 PRECAST 507 721 4eD V4T• �� PRECAST an 1 2M 8261 3712" tsae 2tn am met BSeo to991y eea5aq B86 1407 ta88 2828 2790 8261 8712 T$' (907 PRECAST 743 101t . 1720 2812 2206 INS 8191 am6 T43' (W) PRECAST 424 534 883 T$' (9D`) PRECAST 727 1 1 29M w27 am 1011 1720 seal 8906 Wa467aq 0172aq 727 1224 104 20M 2W 2W 822a 9W (1121 PRECAST 554 W 1180 less WIN 8486 2876 3W 74, (112-) PRECAST 325 512 230 V4' 12� PRECAST all708 t1 1474 187 2167 sm0 7M 1246 1843 2684 OWN 47WW 699Ugq 501 eat 1318 1043 1069 2294 2010 10'4r (126') PRECAST 475 em 1247 2110 2777 2108 2MO 10'4• (1287 PRECAST 254 401 ISO IOW 28) PRECAST 6m 67apq 11118M tteepq 1481pq 17360 2011 us I= 15a8 20021 2781 a8'taeq 47844% no 6B6 1180 1472 N 7788 2066 2a46 11 (1357 PRECAST 362 6a2 go18m 1840 2429 Ili 4m6 11 (13B' PRECAST 280 462 154 11'-4' 1 PRECAST ( 474 m4 e l e00 7007 127 151 1768 6a2 946 INS INS 242a 8727 400e 404 m7 1044111 1872aq 1648 11116" 2187 17-0' (144' PRECAST 337 640 a79 1254 Is"210a 2806 8662 17-0' (144') PRECAST 244 402 187 12' 0' (144� PRECAST 470 458 724 98a 11 1 10a6 640 e79 two 1684 210 sms 470 01) 940m t302 1600M 181111 2076 IX-C 7 PRECAST ( 295 471 766 I= 142E IBM 9810 2883 17-C (150'7 PRECAST 217 324 110 ITrP" (Br PRECAST a4 411 a611 W 786 994 17 471 756 t076 1428 1886 =10 =3 4B0 w0 t159� t41 tB6$,q t88TM oij 1,V4r 1 PRECAST (� 279 474 708 1002 1928 1667 2127 2800 14'-0' (1887 PRECAST 205 283 100 14'-0' (BB') PRECAST a84 � E511M am 724 6B0 1 1220 442 70e 1002 19w 7807 2127 2e90 410 4w 717 A 1083pq 78Se1y 1 IW7 14 8' (17T3� PRESTRESSED N.R NR NR NR NR NR NR NR 14'�' (176� PIffiSTTtESBED N.R.284 91 14' 8' (178� PRESTRE88ED 29B a84 Re WD 672 646 978 1131 458 703 Ism 1002 n45 2517 2712 &B W5 as M pq 1 151 1734 16W (1847 PRESTRESSED N.R. NR NR NR NR NR NR W 15W (154' PRESTRESSED N.R. 259 83 19-C (184-) PRESTRESSED 224 319 4m 027 lee Ott 1054 412 710 12W 7799 211023w 2518 2m WIN Ina a so pq 1 14ODM 16e9 ear 1Td• (2087 PRE87RMO N.R NR NR NR NR NR NR NR 1T-4• RM � N.R. 194 64 IT-C CAA PRESTRESSED 102 7B8 406 827 88B 756 87a am 64B em 13M tm9 IM 2W 1B2 300 608 " 740 m 1006ml l7flm 4479 19' 4' (292� PRESTRESSED N R NR NR NR NR NR NR NR 78 �. C� PRESTRESSED N.R. 148 52 19'-4 (2921 PRESTRESSED 102 18a 220 aq 2B8 SUM 420 Well; 828 aq W 841 847 1 747 PA 1227 gas 420 7m 10a7 1282 1515 rns 21 �• ( ') PRESTRESSED N.R.1m NR NR NR NR NR NR NR , . 21 (2587 PRESTRESSED N.R. 125 42 , , (M PRESTRESSSED 21 r{ 142 Wit 507 898 480 a'1 608 6% 340 690 646 1114 130 140 142 � 873 al 697 am 721 m6 1048 2Z4r I PRESTRESSED N.R. NR NR NR NR NR NIR NR MR NR NR NR NR NR 27-V (M7 PREST1�SSED N.R. 116 40 22-V W7 PRESTRESSED 137 197aq 295 370 402 646 am 7MR 187 22a 35B 518 Bm ap BB8 =I 000 am No (288•) PRESTRESSED N.R NR NR NR NR NR NR NR , 24 O W PRESTRESSED N.R. 91 -WW-W Wn PRESTRESSED 124 124 179 aq 202 287 819 ml 342 466 aq 418 011lam-7b7ml 402 W7 111171111 an 12O ss0 4m Willm4 toes I= (#) THE NUMBERS IN PARENTHESIS REDUCTIONS FOR GRADE 40 FIELD ARE ADDED PERCENT REBAR. (#) THE REDUCTIONS NUMBERS IN FOR GRADE PARENTHESIS 40 ARE FIELD ADDED PERCENT REBAR. -ALL VALUES TAKEN FROM "SAFE LOAD TABLES' SY CASTCRETE MAY 201S EDITION . PRECAST PRODUCTS - ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS - PROVIDE MINI Ml BY OTHERS TO MEET OR EXCEED VALUES STATED ABOVE 4' OF BEARING PAST EACH SIDE OF WINDOW OPENING 1 ♦ 8F16-1T/0M/0B 8F16-1T/0M/0B 8F16-1T/0M/0B lei 0 to ♦ � ` 1� ell 1 GT 8F24-1T/0M/OB 1 � ♦ 1 ♦ I ', 1 I 1 ♦♦ I 1 1 ♦♦ � 1 1 1 ♦ , 1 ♦ I 1 1 �F 1 ' 1 I 1 e ca � 1 o 10 0 2 21 �1 LL 0� ) UNO, PROVIDE BB1 WHERE i ROOF TRUSSES BEAR, TOP -------- OF WALL EL. 8'-8", UNO. 1 � zti � 1 P a �� �♦ i 1 � 1 i 1 � 1 A 8RF6- 1 T/OM/0B r�♦ 1 8RF6-1 1 8F16-1T/0M/0B III♦M 1111111 11111111 M M 1111111 1111111 M 11111111111111A�l & r# e F . W'.Gd I. ".. R , ftfl 1. LIFT SCALE: 1/4" _ Reviewed for Code Compliance E AM PLAN Universal Enginee,Fq Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www abdesigngroup,com AA #: 0003325' F Mail W y U W 0 F F 64 SXMDIV. & LOT: CREEKSIDE PHASE II LOT #41, PROJECT# 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: LIFT BEAM PLAN AND NOTES 160 MPH EXP. C ARCHfTECT STATE OF FLORIDA AUG 0 6 2020 kEL C. ANDEI AR NO 17305 ""'q E: ` DAT08 05 20 I SCALE: 1/4"=1'-0" 1 SHEET S 2 PRODUCT CONTROL NOTICE OF ACCEPTANCE F.E.C.P CORPORATION-CASTE-CRETE DIVISION ACCEP ANCE #' 19-0130 Ti3 #5 CORNER BAR W/ 30" LAP FOR EACH COURSE OF BOND BEAM VERTICAL REBAR W/ 10" HOOK 30' TYPICAL #5 BAR IN BOND BEAM — CORNER REINFORCING OF BOND BEAM SCALE: 3/4"=V-0" NOTES TO THE INSPECTOR/CONTRACTOR 1. PLACE LINTEL ACROSS TOP OF OPENING. 2. IF BOTTOM STEEL IS REQUIRED PLACE #5 BAR IN LINTEL. (�G\ 3. PLACE MASONRY UNITS AS REQUIRED TO ACHIEVE THE REQUIRED BEARING PLACE STEEL HEIGHT �O REINFORCING (1-2) 4. THE LAST COURSE WILL BE A BOND BEAM WITH (1) #5 BAR CONTINUOUSAROUND ENG� AS DEPICTED HEREIN STRUCTURE. A DOUBLE BOND BEAM MAY BE SPECIFIED SO THAT THEN THE LAST \ \ TWO COURSES ARE BOND BEAMS WITH A #5 BAR IN EACH COURSE. 5. SHOULD THE DOUBLE BOND BEAM COINCIDE WITH A LINTEL THE BOTTOM COURSE OF BOND BEAM IS OMITTED AND A LINTEL IS PLACED. THE STEEL /REINFORCING FOR THE BOTTOM BOND BEAM IS TO BE CONTINUOUS THROUGH THE / TOP OF THE LINTEL. 6. UNO COMPOSITE MASONRY BEAM IS TO BE NOT LESS THAN 16" DEEP. 8x16 DBL. BON BEAM W! 1 #5 EACH COURSE • G 8x8 BOND BEAM TOP OF • OQ�G�\N W/ (1) #5 BAR4ND OND BEAM F = FILLED W/ GROUT U = UNFILLED GROUT SOLID FROM NOMINAL LINTEL TO TOP OF BO # OF #5'S, IN 2ND BOND WIDTHBEAMCOURSE BEAM, IF FILLED LINT 1 6_ 1 T/1 M/ R 8x8 PRE -CAST CONCR PQS F�� NOMINAL- -�� v LINTEL W/ (1) #5 BAR ( P�y�G HEIGHT LENGTH OF BAR =WI#OF #5'S, TOP OPENING -2IT IS THIS ENGINEER'S INTENT BOND BEAM COURSE OR2THAT XFXX-1T/1M/OB INDICATES A DOUBLE BOND BEAM #OF#5'S, BOTTOM 8X8PRE-CAST CONCRAND XFXX - 1T/oM/oB INDICATESA SINGLE BOND BEAM PLACED IN LINTEL LINTEL, W/O STEEL (LIT ISTHIS ENGINEER'S INTENT AND XUXX - 1T/1M/0B INDICATES A DOUBLE BOND BEAM ABOVE UNFILLED TO PLAN FOR LOCATITQP LINTEL OF OPENING 10 AND XUXX - 1T/0M10B INDICATES A SINGLE BOND BEAM ABOVE UNFILLED LINTEL BONDBONBEAM D BEE AM TYP.8"x16" io BOND BEAM r MASONRY BEAM DESIGNATION SCALE: 3/4"=V-0" PRECAST HE 2x4 (MIN 2 X'3) 1-3/16 TAPCON OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD WINDOW SIZE .300 MIN EMBEDMENT 1 1/4") 8" FROM' EACH END AND 18" O.C. MAX'. MIN 1-114" EMBEDMENT 2x6 (MIN 2 X 3) 2-3/16 TAPCON PRE -CAST as OR DRIVE PIN (MIN SHANK WINDOW SIZE.145 MIN HEAD SIZE :300 SILL MIN EMBEDMENT 1 114") 8" SLOPE FROM EACH END AND 18" O.C. MAX. MIN 1-1/4" EMBEDMENT 2x8 (MIN 2 X'3.3) 2-3/16 TAPCON OR DRIVE PIN (MIN SHANK SIZE.,145 MIN HEAD SIZE .300 MIN, EMBEDMENT 1 1/4") 8" FROM! EACH END AND TYPICAL MASONRY WINDOW CII I r0KICTRIII'_TI(lN 18" O.C. MAX';, MIN 1-114" EMBEDMENT', SINGLE #5 CORNER BAR, 30x30 TURNED UP OR TURNED DOWN INTO FILLED CELL V2X4 SOLID BLOCKING SECURE TO SHEATHING W/ MIN. 2-12d PER BLK. EA. END 7/16" OSB SHEATHING CMU WALL ARCHWAY FRAMING DETAIL SCALE: 3/4"=V-0" ` STEEL REINF. OF BOND. BEAM PROVIDE #5 BAR EACH SIDE STEEL REINF. OF 0 LEVATION BOND. BEAM CHA E CHANGEIN ELEVATION OF BOND BEAM 7 SCALE: 3/4"= Reviewed C,n, Id Universal Engln Sciences W w x" 0 x sVBwv. & LOT: CREEKSIDE PHASE II' LOT #41 PROJECT# 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: DETAILS 160 MPH EXP. C ARCHrrECT- STATE OF FLORIDA AUG 0 0 2020` MICHAEL C. ANDERSON L AR NO 17305 J PRINT DATE- 08 05 20 SCALE: 1/4"=1' - 0" SHEET ///^9®� 2 e I L g FRAMING NOTES 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W/ (8) 10d x 1 1/2" HDG NAILS, WOOD TO WOOD: SIMPSON H10A OR LGT2 W/ 10d x 1 1/2" HDG NAILS, FILL ALL HOLES. 2, ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS, 7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL, 9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177" ` x 2 7/8" LONG, WITH WASHER @ 16" O.C. 10 TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT, 11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 12, ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. 13. BOTTOM CHORD BRACING, DIAGONAL BRACING AND GABLE END BRACING SHOWN ON THE FRAMING PLANS AND DETAIL ARE DRAWN AS A DIAGRAMMATIC PURPOSES FOR MINIMUM SPANS AND MAXIMUM SPACING. THESE DRAWINGS ARE INTENDED AS A GUIDELINE FOR CONSTRUCTION AND DO NOT NECESSARILY REFLECT ALL ACTUAL CONDITIONS THAT MAY ARISE IN THE FIELD FIELD CONSTRUCTION SHOULD CLOSELY PARALLEL THE BRACING DIAGRAMS WITHIN THESE MINIMUM AND MAXIMUM TOLERANCES. ADJUSTMENTS IN THE FIELD ARE ACCEPTABLE FOR FIELD CONDITIONS SUCH AS INTERFERENCES WITH TRUSS WEBBING, SHEETING ETC. IN SITUATIONS WHERE THE DIAGRAMS LOCATION AND ACTUAL TRUSS WEBBING CONDITIONS CONFLICT, THE CONTRACTOR SHALL PLACE THE DIAGONAL BRAE ADJACENT TO THE TRUSS WEB AS CONDITIONS ALLOW. TRUSS MANUFACTURER / ENGINEER NOTES: 1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2.500 LBS SHALL BE FABRICATED W/ A 2x6 BTM. CHORD (MIN.) 2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES. 3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO TRUSS CONNECTIONS. 4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN. MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. GIRDER/TRUSS W12x6 BOTTOM CHORD END JACK TRUSS BOTTOM CHORD W/MIN (4) 10d INHERE APPLICABLE NAILS FOR EACH CHORD CONNECTION TRUSSES W/2X4 BOTTOM CHORD DIAGONAL BRACING/BOTTOM CHORD BRACING DISSIMILAR BOTTOM CHORD BRACING ® END TRUSSES W/2X4 BOTTOM CHORD G I RDER/TRUSS W/2X6 BOTTOM CHORD BRACING/BOTTOMDIAGONAL —/ 2x4 SCAB NAILED TO CHORD BRA NG I/ I)N//I W MSN BOTTOM NAILS Y I Y' I FOR EACH CHORD CONNECTION DISSIMILAR BOTTOM CHORD BRACING @ MID RUN TRUSSES W/2X4 BOTTOM. CHORD BRACI NGIBOTTOM CHORD BRACING CONNECTOR SCHEDULE CONTROL DATE. 01/27/2020 M ITeh LISP SIMPSON M[Tok USE SIMPSON DES. UPLIFT GRAVITY DES, UPLIFT GRAVITY FASTENER FASTENER HTA 16-18 1625 MET16 145C (S) 10d X 11/2" 1-PLY, (7)16d 2-PLY, EMBED 4" (8) 10d x 11/2" 1-PLY, (6) 16d 2-PLY, EMBED 4" (2)HTA 16-18 2430 (2)MITA-16 19855 (12)10d x 11/2"'1-PLY, IMBED 4" (10)10d x 11/2"1-PLY, EMBED4" HTA 16 1870 HERA-16 1810 I10) 10d X 11/2', (3) 16d 2-PLY, EMBED 4" (9) 10d %1112' 1-PLY, 8) 16d 2-PLY, EMBED 4" HTA 20 1870 EFTA 20 1810 (10) 10d x 11/2', (8) 16d 2-PLY, EMBED 4" (9) lOd x 11/2" 1-PLV. (a) 16d 2-PLY, EMBED 4' 12{HTA-20 2430 i2j IT-,", 2C 2035 (12) 10d x 1112",1-PLY. EMBED 4" (10) tOd x 1 112" 1-PLY, EMBED A" 250C I10) 16d 2-PLY, EMBED 4" (12) 15d 2-PLY, EMBED 4" LUGT-2 1655 LGT2 1885 PER (5) 1/4"x 3" Wedge-Bolt+Anchors, WOOD (16)10d (7) 1/4" x 21/4" TITEN, WOOD (16) 16d I UGT-3 33W LGT3-SOS? 5 3480 CONC ILL 3/8" X 5" Wedge-BoR+Anchors, WOOD (12) W525 112) SDS 1/4'x3' TO GIRDER, (4) 3/8' x 5" TITER! HD TO WALL DHTA-20 2430 DETAL-20 248C (16)-10dx1112, 1 PLY ALTERNATE USEOF(2(HTA -20ACCEPTABLE ITS) -l0dxl1/2, 1 PLVALTERNATFUSEOF(2)HETA-20ACCEPTABLE NIUGTiS+ 3945 MGT+ 3965 (1)5/8"A.T.R. IN HIGH STRENGTH EPDXY (MIN, 12" EMBED),(22110d TOWOOD) (1)5/8"A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED),(Z2I10d TO WOOD "HbT2. 9575 FGT-2 + 10690 WOOD (8j 10d, MASONRY (2j 3':" r\.T.I (2) 314" A.T.R. IN HIGH STEEN GTH EPDXY (MIN. 12" EM BEDi, (16j 10d TO WOOD IIUGT3+ 986C HGT-3+ 10690 WOOD (8) 10d, MASONRY (2) 3/4'AS.R (2) 3/4" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12' EMBED), (16) lOdTO WOOD LPTA 1.510 PARALLEL TO WALL 1470 PERPENDICULAR TO WALL LTA2 1210 PARALLELTO 1210 PERPENDICULAR WALL WALL TO (10)Hod x 11/2' (10)10dx 1-1/2' MUGT IS 3945 VGT 4940 (1) 5/8' I N HIGH STRENGTH EPDXY )MIN.12"EMBED),(4)1Dd TOP/(6)10d FACF/(12) Tod BACK OF TRUSS (1)5/8"A.T.B. IN HIGH STRENGTH EPDXY (MIN 12" EMBED), (16) SDS 1/4'x3' HUGT 1 9575 (21 VGT 7185 (21S/8"A.T.R. IN HIGH STRENGTH EPDXY (MIN, 12"EMIBEDE I8)10d (2) 5/8" A. I . R. I N HI GH S TR EN GTH EPDXY (MIN. 12" EM BE D), 134 SD51/4"x3" MTW 12 %5 MTS-12 990 (14)10d x 11/2",(14)10d (14)10d X 11/2" H IW 16 1355 H'r-16 1310 (16)10d X 1 1/2", (16) 10d (16! 10d X 1112" HTW 2D 1355 H'TS-20 1310 (24)10d X 11/2",(20)10d (24)10d X 11/2' H TA' 24 1355 HTS-24 1310 (24)10d X 1. 112",(20)10d (24)10d x 11/2" ESTa 12 +* 930 LST412 +- 925 (10) 10d 110) lod LSTI.. !a At 1235 LSTA-18 ++ 1235 (14)10d (14)10d NISTA-18++ 1310 MSTA-18 +* 1315 (14) 10d H1 ) 10d MSTA 24++ 1640 MSTA 24 t- F40 (18)10d (18)10d MSTA-30++ 2065 MSTA-30++ 2050 (22)10d (22)Wd MSTA 36++ 2065 MSTA-31,+- 2050 (26) 10d (26) TOY! KSTI235 2765 MST)-36 3300 (36)ludX 1112" (36310d X 11/2' KT51248 5105 MST)-48 5070 (48) 10d X 12/2" (48)10d X 11/2" UP TA6 980 H6 CC55 (16) Ad x 11/2'. (16) ad) (8) ad TO PU%TES,(8) ad TO STUDS SPT4 875 SP4 825 (6) lid TO STUDY (6)10d TO PLATE (6) 10d x 1112" TO STUDS MP34 5251N F1 GT 160% A34 430 (4; ad 11/2' TO BEAM, (4) 8d x 11/2" TO POST, T4)adx 11/2" TO BEAM, (4) ad x 11/2"TO POST. HIICP2 680 HCP2 590 (10)10d x 2 2/2" TO TRUSS, (10) 10d X 11/2"10 PLATE (12) 10dX 11/2" kT]6A 1020 H10A 1040 (9} 10d x 11/2" TO TRUSS, (8)10d X 11/2' TO PLATE (18)'10d X 11,/2" NI UG15&PHD4A 4175 V H VGT DU4 4940 2810d TO TRUSS 10 WS3 WOOD SCREWS TO POST SS" ( ) ,( ) W/ / THREADED ROD (16)�SDS lf4"x3"TO WOO D,(10)-SUS 1/4"x2't/2"W/THREADED RDD, (2)NW 5/WASHER/2 PLY ' MIIGTI5&PHD4A 1 4175 VISIT &HIM 4940 (28)10d TO TRUSS,1'10) WS3 WOOD SCREWSTO POST W/ 5/8 ' THREADED ROD (16)3D51/4"0"TO WOOD, 13)-3/4"STUD BOLTS W/THREADED ROD, (2) NUTS/WASHER/2PLY PAU44 2535 67/S ABU 44Z 2300 7i SC (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONIC.. (12) i6d TO WOOD (1) S/8" A.1R IN HIGH STRENGTH EPDXY, (MIN. T' EMBFOL IN CONC, (12)16d TO WOOD PAU65 2455 16005 ABU 66Z 2190 18205 (1)5/8"A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONC,(12)i5d TO WOOD (1)5/8"ItT.R. IN HIGH STRENGTH EPDXY. (MIN. 7" EMBED.) IN CONC., H2)16d TO WOOL) LTS19 ++, 1205 LTT19-++ 1330 (1)3/4"A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7' EMBED) IN CONC.(8)l0d TO WOOD (1)3/4"A.T.R. IN HIGH STRENGTH EPDXY, (MIN 7" EMBFDT IN CONC RH10d TO WOOD LT52CR+-. lIDC LTT2013«+ 1500 1 1 (1j3/4"A.T.9. IN HIGH S TRENGTH EPDXY, IMIN. 7'EMBED) IN CONC.,(10j10d x 1-ij2 ED WOOD 11) 112" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. T' EM BED.) IN CONC., (10) 10d TO WOOD HTT45 4160 HTT4 4155 (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. T' EMBED) IN COW., (19)'i6d X 21/2" (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 7" EMBED,) IN CONC., (26)16d X 212" HT745 5C05 HTT5 5090 (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 7" EMBED) IN CONC_ 26116d X 21/2" (1) 5/8" A.T.R IN HIGH STRENGTH EPDXY (MIN. T' EMBED.) IN CONC- (26j 16d X 2 D2' UPHDll+ 1439S HHDQ1'1-SDS ] 23- 11810 (11 V A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 10' EMBED) IN COLIC, (24) WS3 WOOD SCREWS (1)1" A.T.R. IN HIGH STRENGTH EPDXY, (MIIN. 10" EMBED.) IN CONC, 124) SDS %" x 2%" WOOD SCREWS PHUSA 6525 HD7B 6645 (1) 5/8" A.B. IN HIGH STRENGTH EPDXY, (MIN 7' EMBED) IN CONC ;14) WS3 WOOD SCRFWS (1) 7/8" A.B. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED.) IN CONC'., (3I3/4' STUDSOLTSTO W003 TDXB 7870 (1;. 7/8" A.B. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONC. (3) 7/8" STUD BOLTS 1O WOOD NTMI35%12U 2580 7130 NIBHA 3.55/11.25 3475 5330 (1) 112'' 1-EDIT W MIN 6" EMBED & NOT LESS THAN 4" FROM EDGE OF CONC W/3/4" CIA ITW RAMSFT/REDHEAD DYNA BOLT SLEEVE ANCHOR OR EQ'N/MIN 5"EMBED INSTALLED IN FACE.(14)10d AT106T (1) 3/4" A.T. R. IN HIGH STRENGTH EPDXY, (MIN. (iJ5" EMBEDMENT) IN C.MAL TOP, (1) 3/4' A.T.P. IN HIGH STRENGTH EPDXY, (MEN. 6,75'EMBEDMENT) IN C.M,U. FACE,(18) lUd TO BEAM HII54121F 3615 2710(100%) HUSC412 (WOOD) 3435 2635 pOC"S; LTD) 16d TO HEADER, (10) 16d TO WOOD (10) 16d TO HEADER, (10)16d TO WOOD 3325 (125%) 3220(125%) HU--10IF(CMUI 1950 3080 FI UC410 (CMUj ism 4500 (18) 1/4"" x 3"" WS3 SCREWS, (10) IOd TO W000. LISP (20) 3f16"" TAPPER.. (10) 10d TO W000 (18) 1f4 x 2-3/4.. TITEN (9 PER FLANGE) TO CMU. (10) 10d TO \NOOD- HU210-21F (CMUj 1950 3080 (CMU) HUC210 2 ISO()4501'1 (18)1/4""x3"" WS3 SCREWS,(1Oj 10d TO WOOD. USE (20) 0/16 TAPPER+, (10) 10d TO WOOD "" (1S)1 4" x 22-3/4 -3/4" TITEN ( PER FLANGE) TO CMU, (10) lUd TO WOOD. HU210-3IF;CMU) 2795 5015 HUC210 3 (CMU) 1800 4500 118I 1/4"" x 3"" WS3 SCREWS, (10) lOd TO WOOD. USE (20) 3/16"" TAPPER+, (10) 10d TO WOOD 18) 1/4 x 2TITEN (9 PER FLANGE) TO CMU, (10) 10d TO WOOD'. LGUM26-2 2125 6065 LGUM26-2-SO 1430 5595 (4) 3/8" X 4" Wedge Bolt+ Anchors, WOOD (4) WS3 WOOD SCREWS (4) 3/8 x 4 TITEN HD ANCHORS (2 PER FLANGE) TO CMU, (4) 1/4 X 2-1/2 SDS SCREWS TO WOOD M CJ, CA CA 2X4 BLOCKING BETWEEN TRUSSES 24" O.C. TOE NAILED TO ADJACENT TRUSSES W/ (2) 16d COMMON NAILS & SECURE TO BM. W/ SIMPSON LTA2 USED TO BRACE TOP OF WALL. II n u if n u u u u n u n11 1II = II ATTACHII4'-0" LOI NG 1111 SCAB IITO II II II II II II TRUSS W/ 10d NAILS @6"O.C. If II II II II --- II (4" FROM EA. END) II II II II II 1 A,4G —r--r r �1 I I I 6 I I 102 N Z - _ _ _ — _ — PREfABRICA ROOF v TRUSSES 6 24.0 MAX. r= a=—___--____ n �i A,A I I I I I I 22"x544" _ 1 ATTIC I I a ACCESS_ _ ^s p W m I I I I I I w z 0 V All Lu _ J V Al 1A — --- 1A --- --- --__' ,A 1 1 3.1 3.1 I I I A,6 7 V 8 \ / 7 V 8 FRAMING PLAN SCALE: 1/4" = V-0" Reviewed for Code Compliance Universal EnglneelW $cwmes 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W U W O 0. W G F A ti SUE13DIV. & LOT: CREEKSIDE PHASE II LOT #41 PROJECT* 04321.200 041R1 MODEL: 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: FRAMING PLAN 160 MPH EXP. C ARCHrTECT: STATE OF FLORIDA AUG 0 5 2029 MICHAEL C. ANDERSON AR NO 17305 J DAATTE: 08/05/20 SCALE: 1/4"=1' - O" SHEET S 3 A-(1) SIMPSON HETA16 TRUSS ANCHOR WITH (9) 10d x 1 z" NAILS TO TRUSS PLYWOOD SHEATHING, SEE 3-(2) SIMPSON HETA16 TRUSS ANCHOR WITH "ROOF/WALL/FLOOR (12) 16d x 1 2" NAILS TO TRUSS SHEATHING FASTENER SCHEDULE" DBL STRAP, 1 EACH SIDE WRAPS UP AND OVER TRUSS (NOT SHOWN) -(1) SIMPSON LGT2 GIRDER TIEDOWN WITH NOTE: A PT SYP #2 2" x 4", (16) 10d x 3 4' NAILS TO GIRDER AND 6", 8" x 4'-0" MAY BE ADDED (2)SIMPSON HETA16 TRUSS ANCHORS W/ 10d NAILS, 2 ROWS, 3" WITH (12) 16d x 3 Z" NAILS TO GIRDER O/C TO FACILITATE ONE ADDITIONAL PLY MAX. TO 1x2, 2x WOOD FASCIA ACCOMMODATE TRUSS SEE ARCHITECTURAL ANCHOR REQUIREMENTS. 2x SECURED W/ (3) 16d GALV. COMMON NAILS. ENGINEERED WOOD 1x2 SECURED W/ 10d TRUSSES @24" O/C, GALV. COMMON NAILS ; SUBMIT SHOP DRAWINGS 12" O/C FOR REVIEW AND APPROVAL \SONRY BOND BEAM E SCHEDULE AALLOWABLE UPLIFT = U:1810 LBS, L:770. LBS (1 PLY).. B ALLOWABLE UPLIFT = U:2365 LBS L1430 LBS (2 OR 3 PLY) C ALLOWABLE UPLIFT = U:2705. LBS (2 PLY) TYPICAL TRUSS/ 1a 1b 1c GIRDER CONNECTORS) SCALE:3/4"=1'-0" 4 NOT USED Rm OUTER 113OF SPAN ONLY BTM. — PLATE —NOTCH DEPTH 1/4*D HOLE EDGE >518" HOLE DIAMETER < 2/5*D SGL. STUD HOLE EDGE>5/8" HOLE DIAMETER < 3/6*D DBL. STUD STUD NOTCHING AND BORING LIMITS 0 SCALE:. 1 1/2"=1'-0" ENGINEERED WOOD TRUSSES PLYWOOD SHEATHING, SEE @ 24" O/C, SUBMIT SHOP "ROOF/WALUFLOOR' DRAWINGS FOR REVIEW SHEATHING AND APPROVAL FASTENER SCHEDULE", (1) SIMPSON HETA16 TRUSS ANCHOR WITH T NOTE. A PT SYP #2 2" x 4", (9) 1Ad x 1 Z" NAILS TO 6", 8" x 4'-0" MAY BE ADDED GIRDER. PROVIDE 5" W/ 10d NAILS, 2 ROWS, 3" MINIMUM CONCRETE O/C TO FACILITATE ONE EMBEDMENT. USED IN ADDITIONAL PLY MAX. TO CONJUNCTION WITH ACCOMMODATE GIRDER HEAVY UPLIFT TIEDOWN REQUIREMENTS. CONNECTOR A-(1) SIMPSON LGT3-SDS2.5 GIRDER TIEDOWN WITH (4) e" x 5" TITEN HD TO CMU AND (12) SDS ' 4"x22"TO GIRDER B-(1) SIMPSON FGTR GIRDER TIEDOWN WITH 1x2, 2x WOdD FASCIA (2) z" x 5" TITEN HD TO CMU AND (18)SDS 4" -x EARCHITECTURAL SEE ARCHITECTURAL 3" TO GIRDER 2x SECURED W/ (3) 16d C-(2) SIMPSON FGTR GIRDER TIEDOWNS WITH GALV. COMMON NAILS. (2) z" x 5"TITEN HD TO CMU AND (18) SDS 4" x 3" 1x2 SECURED W/ 10d MASO RY BOND SCREWS TO GIRDER (EACH TIEDOWN) GALV. COMMON NAILS BEAM ENSURE THAT CELLS ARE GROUTED 12" O/C SEE SC HEDULE SOLID', 8" EACH WAY OF BOLTS A ALLOWAE LE UPLIFT = 3285 LBS (2 OR 3 PLY) B ALLOWAE LE UPLIFT = 4725 LBS (2 PLY MIN.) C ALLOWAE LE UPLIFT = 8885 LBS (2 PLY MIN.) TYPICAL ROOF 2a 2b 2c GIRDER CONNECTOR(S) SCALE 3/4"=1'-0" NOT USED 9 NOT USED 6'-0" MAX (W/1X4) OR 10'-0" MAX (W/2X4) c i` # 1100 UPLIFT SIMPSON HTSM20 W/10 10d TO. TRUSS AND (4)1 1/4" x 2 1/4" TITEN 2 ANCHORS TO CONT POURED LINTEL # 1900 UPLIFT (2) SIMPSON HTSM20 INSTALLED ON OPPOSITE FACES OF BLOCK WALL W/10 10d TO TRUSS AND (4) 1/4" x 2 1/4" TITEN 2 ANCHORS TO CONT POURED LINTEL PRE-ENG TRUSS CONTINUOUS BOND BEAM A I _j TITEN 2 ANCHORS MIN. 2" COVER & 2" APART REPAIR OF MULTIPLE MISPLACED EMBEDDED TRUSS ANCHOR 1x4 DIAGONAL BTM. CHORD BRACING, SEE PLAN FOR LOCATION MAY NOT BE REQUIRED BTM. CHORD OF WOOD ROOF TRUSSES 1x4 BTM, CHORD BRACING 6-0" O/C END WALL OR OTHER MAX., OR 2x4 BTM. CHORD BRACING END TYPE CONDITION, IF 10'-0" O/C MAXSECURED W/ (2) 10d DEPICTEb SEE PLAN COMMON NAILS AT EACH CHORD INTERSEQTIDNTYP. c BTM. CHORD BRACING 6 SCALE: 3/4"=1'-0" S_NPOLUSED SCALE: 3/4"=1'-0" (2) 2X4 No.2 SYP DIAG, 2x4 BLOCKING BETWEEN BRACE W/ (3) 12d @ EA TRUSSESWHERE TRUSS (DIAG. BRACE TO X-BRACING IS PRESENT AT COVER 5 TRUSSES) 4'-0" O.C. (AT SHEATHING 0'-0" TO 30'-0" (1) "X" BRACE SEAMS) 30'-l"TO 60'-0 (3) "X" BRACE SECURE 2x8 PT. PLATE (1) "X" BRACE @ CENTER TO BLK W/ 1/2" DIA. (2) "X" BRACE DIVIDED EQUALLY ANCHOR BOLT W/ 2" FROM CENTER TO END. WASHER SET IN HIGH 2x WOOD FASCIA, STRENGTH EPDXY 6" SEE ARCHITECTURAL MIN. EMBED. AT 32" OC MAX. PRE-ENG GABLE TRUSS SECURE GABLE TO 2x8 P.T. PLATE W/ 12d's 8" STIFFBACK (AS PER O.C. MAX TRUSS ENG) CONT. 2X4 SECURED W/ (2) 10d's @ EACH TRUSS TO BE INSTALLED @ 10'-D" O.C. MAX. SEE SCHEDULE FOR BOND BEAM REQ. BLOCK WALL W/ GABLE END PRE-ENG'D TRUSS SCA` THE USE OF ALTERNATE MATERIALS MAY BE USED SO LONG AS THEY CONFORM TO THE FOLLOWING 1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS EQUIVALENT OR GREATER UPLIFT AND LATERAL (F1 AND F2) LOAD CAPACITIES AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2 FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE SUBJECT TO F1 AND F2 FORCES. ALTERNATE MATERIALS SCALE:, 3/4"=V-0" ID Revie Compliance r Code COnipliance Universal Englneeriq Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 ti W U W O F a W 4 F A ti W u 0 W suBDiv. 8e LOT: CREEKSIDE PHASE II LOT #41 PROJECT* 04321.200 041R1 MODEL: 4EBB (' "1828-CALI" GARAGE SVnNGu RIGHT PAGE: DETAILS 1,.160 MPH EXP. I ARCHrrECT- STATE OF FLORIDA AUG 0 6 2020 IICHAEL C. ANDERSOI AR NO 17305 PRINT DATE: 08 05 20 SCALE:1/4 90=11- 0" SHEET S3. 1 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www. a b d esigngroup.com AA #: 0003325 F rq W cli U M4 O F 0. U h W 4 F A E-4 ti SUBDIV. & LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL: 4EBB "1828-CALI" GARAGE S VnXG: RIGHT PAGE: DETAILS 160 MPH EXP. C ARCHrrECT. STATE OF FLORIDA h r Frl r d3S HAEL C. ANDEI AR NO 17305 PRINT 08 05 20 DATE - SCALE: 1/4"=1' - 0" SHEET . 1B ppppppppV ppppppppA VTCR SPACING (1) AT EACH END ppppppppG p 2x4 BLOCKING BETWEEN TRUSSES VTCR- AND 6-0" O.C. MAX. ppppp p (2) 2X4 No.2 SYP DIAG. WHERE X-BRACING IS PRESENT AT BRACE W/ (3) 12d @ EA. 4'-0" O.C_ (AT SHEATHING SEAMS) TRUSS (DIAG. BRACE TO COVER 5 TRUSSES) 0'-0" TO 3&-0" (1) X' BRACE �"\, ppppppGp[ 30'-l" TO 60'-0 (3) "X" BRACE PRE-ENG GABLE TRUSS Gpppppppp (1) "X" BRACE @ CENTER "X" �� ppGlppppp pIIlGpppp (2) BRACE DIVIDED EQUALLY STIFFBACK AT ALL 2x SUB -BAND FROM CENTER TO END. UPRIGHTS OVER 4'-10"HIGH \' o (AS PER TRUSS ENG) PLYWOOD SHEATHING, SEE �\ �- "ROOF/WALL/FLOOR �` SHEATHING FASTENER SCHEDULE" - SEE TYP TRUSS CONNECTOR ---- DETAIL FOR STRAPPING INFO. DQ SIDE VIEW 1 x2, 2x WOOD FASCIA — -_- CONNECTION PER SEE ARCHITECTURAL TRUSS MFG. 2x SECURED W/ (3) 16d ENGINEERED WOOD GALV. COMMON NAILS_ TRUSSES @ 24" O/C, 1 x2 SECURED W/ 10d SUBMIT SHOP DRAWINGS GALV_ COMMON NAILS FOR REVIEW CONT. 2x4 RAT RUN 12"O/C ANDAPPROVAL SECUREDW/(2)12d's@ PRE—ENGINEERED MASONRY BOND BEAM SEE SCHEDULE EACH TRUSS VALLEY TRUSS CONNECTION GABLE END PRE-ENG'D TRUSS 2 SCALE NTS. W/ HI P RETURN SCALE 3/4"=V-0" Reviowed for Cods Compliance Universal EngmeoVft Sciences 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W U W 0 F 0. V W 4 F SUBDIV. & LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: DETAILS 160 MPH EXP. C ARCHrrECT- STATE OF FLORIDA AUG 0 6 2020 ►EL C. ANDEI AR NO T7305 PRINT DATE: 08 05 20 SCALE: 1/4"=1'-0" SHEET Sae 1C A. A. GABLE - END IK • • i • • • 41 1 • • I • w w w • Ij HIP ROOF ROOF WIND DESIGN PRESSURES NET (GROSS) ASCE 7-10 ZONE 1 = 23.79 PSF (33.79) ZONE 2 = 39.48 PSF (49.48) ZONE 3 = 67.16 PSF (77.16) "A"= 4'-0" END ZONE DISTANCE BASIC WIND SPEED: 160 MPH WIND EXPOSURE: "C" RISK CATAGORY: II APPLICABLE INTERNAL PRESSURE COEFFICIENT +- 0.18 ROOF DIAPHRAGM FOR ASPHALT SHINGLE ROOF, USE MIN7116" O.S.B. OR 1/2" CDX EXT PLYWOOD, FOR CEMENTITIOUS TILE AND METAL ROOFING, USE MIN. 5/8 CDX EXT. PLYWOOD, WITH Bd RING SHANK GUN NAILS AT 4" O.C. AT SUPPORTED PANEL EDGES AND 8d RING SHANK GUN NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS. SEE DETAIL. ROOF SHEATHING TO GABLE END FRAME USE 8d GUN NAILS @ 4" O.C. EDGEWISE 2x4 BLOCKING ALL PANEL JOINTS W/ IN 4' OF GABLE END. ROOF/ WALL/ FLOOR SHEATHING FASTENER SCHEDULE NAIL SCHEDULE SIZE TYPE MIN. LENGTH MIN. DIA. SHANK TENSILE STIR. SHANK 8d RING SHANK, 21/2" 0.120" 170,000 RING (16-20 RINGS SCREW SHANK PER INCH) 8d SCREWSHANK 21/2" 0.120" PNEUMATIC SCREW -NAILS 1. NAIL SIZE PER ASTM F1664 TOP CORD BLOCKING AT 4' 2. INTERNATIONAL STAPE, NAIL & TOOL O.C. MAX. IN FIRST 2 FRAMING ASSOCIATION (ISANTA) ESR-1539 SPACES AT EACH END. RAFTER OR TRUSS ROOF SHEATHING EXTERIOR SHEATHING USE 1/2" CDX OR 7116" O.S.B. PLY WITH 8d RING SHANK GUN NAILS AT 4' O.C. AT PANEL SIDES AND 8d RING SHANK GUN NAILS 4" O.C. TOP BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS OR 7/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUR SPECS.) SEE DETAIL. 8d RING SHANK GUN NAILS @ 4" O.C. TOP & BOTTOM EDGES @ J • J Z 1 Z D (D OJ LU S - `L Z Q U) Z - U O .. z Z z m � Y [Y Z x (q 0 Z . . ...... EE 00 ZUJ U) Z (D o W Y @_) z 2 L) � b V Z 2f 13 0 BUILDING LENGTH ROOF SHEATHING LAYOUT AND ENDWALL BRACING FOR GABLE END FRAMING 8d RING SHANK GUN NAILS �a 6" O.C. IN FIELI5 4FIEATHINf; ATTARHMPMT Fnp R(V1F CHF. ... A,�.k_ GENERAL NOTES: ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33, MAXIMUM AGGREGATE SIZE SHALL BE 34". STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND I'� WOOD: '.. ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT PROVIDE 6%AIR ENTRAINED CONCRETE EXPOSED: TO EARTH OR WEATHER NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF. ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS; AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBC-R 2017, 6th EDITION ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 314". ' ALL WOOD FOR BEAMS, BEARING WALLS, SOLE. PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING, ACI 318-14BUILDING CODE REQUIREMENTS CRIPPLERS, SILLS, ETC., SHALL BE SOUTHERN PINE NO. 2 OR BETTER Fb = 1100 PSI AND A MODULUS OF FOR STRUC RAL CONCRETE, ACI 530-13/ASCE 5-13 AISI SPECIFICATION FOR THE DESIGN OF PROVIDE6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON 0 ER MEMB ELASTICITY = 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE COLD -FORMED STEEL STRUCTURAL MEMBERS 2011, ASCE 7-10 AND AISC SPECIFICATIONS DRAWINGS. SEAMS LAPPED 6INCHES AND .SEALED WITH ADHESIVE TAPE PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES FORM SHALL BE RATED TO RETENTION LEVELS OF 0.25 PCF OF BORATE PRESERVATIVE TREATMENT: DISODIUM ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TORE TYPICAL AND -WORK: CORROBORATE TETRAHEDRAL(DOT). WOOD FOR STRUCTURALUSE THAT SHALL BE TREATED FOR ANY SHALL BE CONSTRUED O TO APPLY TO ANY SI MILAR SITUATION ELSEWHERE ON THE PROJECT, FORM -WORK, SHORING, AND BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, REASON SHALL BE RATED TO. RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED EXCEPT WHE RE A.DIFFERENT DETAIL IS SHOWN. AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347,', W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID. BUYING TREATED LUMBER THAT "RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK. CONTAINS MORE THAN %" OF HEARTWOOD. ALL DIMENSI NS AND CONDITIONS MUST BE VERIFIED, IN THE FIELD. DO NOTSCALE THE - DRAWINGS FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT EXCLUSIONS FROM THESE PLANS: j MINIMUM NAILING PER FBCR 2017, 6th EDITION. SEE NAILING SCHEDULE ON PLANS. TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART. WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS OF THE WOR ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL. DEPENDING PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUTARE BY OTHERS:, SYP#2. '. THE STRUCT RE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THEBUILDING IS COMPLETE. IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE. SEAT PLATES SHALL BE PROVIDED SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS WELDED WIRE MESH: AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS. OR TIE -DOWNS. WELDED WIRE MESH, SHALL BE ASTM A185, GRADE 65 AND BE PLACED IN ACCORDANCE NTH THE ACI WOOD TRUSSES: TYPICAL DETAILS. MINIMUM LAP. SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL BE G (O.S.B TO BE STRUCTURAL GRADE) J a L Z ¢w w C9 LU '.. w U C 8d RING SHANK GUN NAILS' IN U ~ U @ 12" O.C. FIELD or 8d x 2 1/2" SCREW SHANK fn O PNEUMATIC SCREW -NAILS@ 12" O 6�IN � W ifl FIELD J\ d TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION SUPPORTED WITH 2" CHAIRS SPACED T-0" OC, EACH WAY. TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR STRESS -GRADE LUMBER AND ITS FASTENINGS" BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN FLORIDA. SEE NOTED FOR SHOP DRAWINGS. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR REINFORCING STEEL: CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036"AND BE MANUFACTURED FROM STEEL TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. REBAR SHALL BE ASTM A615GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A615 MEETING THE REQUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE DESIGN GADS: W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. DESIGN, FABRICATE; AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14, "DESIGN NATIONAL CONTRACTOR SHALL. SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL STANDARDS FOR METAL -PLATE -CONNECTED -WOOD TRUSS CONSTRUCTION:, AND "TPI/WTCA BCSI 1" ROOF: UVE LOAD FLOOR: LIVE LOAD 40 psf - AND VERTICAL BARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEERS, COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED 20 psf -P REVIEW.. TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36" ' WOOD TRUSSES. 10 psf BTM CHORD -non-concurrent #5 BAR - 30" #7 BAR - 42" I TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF PROVIDE 36" x 36" CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR DEAD LOAD DEAD. LOAD FOR ADDITIONAL INFORMATION. INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI A58.1-1982. 15 psf TOP CHORD 20 psf TOP CHORD (7 psf wl ASPHALT SHINGLES (10 psf w/ No GYPCRETE) ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS:. 10 psf BTM CHORD 5 psf BTM CHORD THICKENED SLAB BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH EAD LOAD TO RESIST WIND UPLIFT: 10psf MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE. CONNECTION DETAILS AT BALCONY LIVE LOAD 60 psf WALL I, TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. WIND: ' DEAD LOAD SPEED =160 MPH 3-SECOND GUST STAIRS LIVE LOAD 40 psf RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING ' (ASCE 7-10 (FBC R2017) EXPOSURE: C, RISK CATEGORY II) INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. 1 DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL LIVE LOADS. UNINHABITABLE ATTIC WITHOUT STORAGE: 10psf, UNINHABITABLE ATTIC NTH LIMITED LAYOUT, SPANS& ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT STORAGE. 2 psf., HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30psf, BALCONIES EXTERIOR (EXTERIOR) DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED'', ITEMS AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON. THESE PLANS SHALL BE NOTIFIED TO THE DECKS Opsf, ,OUAsf, AND HANDRAILS: psf; GUARD IN-FILLOM:4 COMPONENTS: SOO PASSENGER WITHOUT THE APPROVAL OF THE ENGINEER. ' STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OF TRUSSES. THE TRUSS FABRICATOR SHALL VEHIAND N AGES: 50psf, ROOMS OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30psf, STAIRS: PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION 40psfEGA aopRf MASONRY: PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH. ALL REQUIREMENTS OF THE , LICENSED PROFESSIONAL ENGINEER. SHOP DRAWING REVIEW; "SPECIFICATION MASONRY STRUCTURES" (ACI 530/ ASCE 5/TMS402, BUILDING CODE REQUIREMENTS FOR SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE. WITH THE DESIGNING INTENT MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS OF THE CONTRACT DOCUMENTS ONLY. 9T SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE PROVIDED BY THE TRUSS ENGINEER_ COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS ,ETC. ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT. MANUFACTURED IN. CONFORMANCE WITH ASTM C-90, GRADE fm = 1500 PSI. BLOCK SHALL 6E PLACED USING - OF THE DELEGATED TRUSS ENGINEER. WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-10 COMPONENT AND CLADDING WIND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR DRAWINGS S EMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. SHOP DRAWINGS. IN THE FORM "RUNNING BOND UNLESS OTHERWISE LAY-UP' MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE ALL TRUSS TO TRUSS CONNECTIONS. OF OF REPROD CIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL A MAXIMUM DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWISE SPECIFIED IN HAVE 31p" WRITING BY rHE ARCHITECT. - COURSE AGGREGATE, AND SHALL BE PLACED W/ A SLUMP OF 8" TO 10". USE ONLY MECHANICAL VIBRATION - TO CONSOLIDATE GROUT. FOUNDA IOW SITE PREPARATION: TYPE 'M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE FOOTINGS W RE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf, FOOTING PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTALANDVERTICAL MORTAR JOINTS - EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95% OF. THE SHALL BE 318" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO - MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D-1557. TREAT. ALL CELLS TO BE FILLED. SOIL FOR TERMITE PROTECTION, FILL CMU CELLS SOLID WITH GROUT ATALLCELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL THE OWNER HALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL.ENGINEER TO VERIFY'... REINFORCING. SUCCESSFUL. COMPLETION OF SITE PREPARATION EFFORTS.. LOCATIONS FAILING TO.MEET THE - GEO-TECHNI AL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE .LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O.' CONTRACTO 'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE I i" MINIMUM DEc IGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL STRUCTURAL STEEL: BE MADE BY HE.GEO-TECH. ENGINEER, '. - THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE CONCR SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, 9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS. AS FOLLOWS A36, Fy = 36 ksi FOR ANGLES, PLATES, AND W-SHAPES, STRUCTURAL TUBING SHALL BE ASTMA-500, GRADE B, Fy = 46 ksi. STRUCTURAL PIPE SHALL BE ASTM-53, GRADE B, TYPE E OR S',, Fy = 35 ksi. TUBE AND PIPE 2,500 P REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. 3,000. P 31 REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB, ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL CONTRACTOR SHALL'SUBMIT PROPOSED MIX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO OTHER BOLTS SHALL BE ASTM A325-N BOLTS WITH WASHERS UNDER: THE TURNED ELEMENT. BOLTS SHALL CONCRETE PLAEMENT. CONCRETE SLUMP SHALL NOT EXCEED 5"+!-PRIOR TO THE ADDITION OF PLASTICIZER. BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD. '.. CONCRETE SH L COMPLY WITH ALL THE REQUIREMENTS OF ACI 301 AND ASTM C-94 OR MEASURING, MIXING, TRANSPORTING, ETC. ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J-BOLTS ARE TO BE STEEL. CONCRETE TIC ETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWEDFROMWHEN WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FOR ANY REASON THERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE RESPONSIBILIT OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY NON COMPLIANCE W TH THE ABOVE. REQUIRED CON RETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS: A. 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS)'. B. FOR CONCRETE EXPOSEDTOEARTHAND/OR WEATHER', _ 1-1/T FOR #5 AND SMALLER 2'F #6 AND LARGER C. FOR COI ICRETE NOT EXPOSED TO WEATHER 3/4" FOR SLABS, WALLS AND JOISTS 1-112" FC RR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS I FASTENER SCHEDULE WINDOW AND DOOR BUCK FASTENERS FASTENER APPLICATION SIZE. TYPE SPACING REMARKS APPLICATIONS SIZE TYPE SPACING REMARKS 1.2 PT FURRING TO CASE HARDENED COIL S,� O/C GARAGE DOOR BUCK 114" DIA TAPCON MASONRY 1 12" EMBED., 4" END DIST., MASONRY! CONC. NAIL 1 12" LONG. ' TO MASONRYICONC. NO WASHER FASTENER 8 O/C1 1/2" EDGE DIST SGC ALS CASE HARDENED COIL WqRJ FASTENED GARAGE DOOR BUCK 112" DIA WI 4' EMBED., 4" END DIST. . SEE NOTE 6 STAGGERED INTO M/ASO !GONG. TO MASONRY/GONG. WASHER EXPANSION BOLT 24" O/C 3" EDGE DIST. WINDOW BUCK CASE HARDENED COIL 9"O/C WINDOWIDOOR/FASTENE METAL STRAP TO �+ /� CONTACT THIS IIS ENGINEER FOR SPACING 1x PT, SEE NOTE NAIL 1112"LONG, STAGGERED INTO MASONRY/CONC. MASONRY/CONC. REQUIREMENTS REQUIREMENTS J EXT. SWING DOOR (2) 3l16"DIA "TAPOON 1112 EMBED: B" END. NON -BEARING WOOD 12 ° EXPANSION 4" EMBED. 4" END BUCK 2x PT, SEE NOTE 6 NO WASHER PARTNER 18" O/C DIST., 1 12" E GE DIST WALL TO CONGSLAB W/ WASHER BOLT 24„ O!C DIST, 3" EDGE DIST. 2x PT WINDOW BUCK B.13B° PAF x 21l8" 9" O!C 4" END. DIST:, 1 12" PT TO STEEL COL., SEE W/ WASHER STAGGERED EDGE DIST NOTE 6 NOTES 1. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS 2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKSISHALL BE AS PER MANUFACTURER'S SPECS AND / OR NOA 3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED - 4. PAF SHALL BE HI.LTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN 5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE 6. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. lx MEMBERS ARE NAILED AND 2x MEMBERS ARE SECURED W/ TAPCONS OR PAF TO THE SUBSTRATE. for Go,* peviewed xr�s WiaOt Eno I E 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesli8,.ngroup.com AA 0: 0003325 F W PA rr7 V W O I. 0. V O F I q II ti SUBDIV. 8a LOT: CREEKSIDE PHASE II LOT #41 PROJECT# 04321.200 041R1 MODEL: 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: DETAILS 160 MPH EXP. C ARCHrrECT STATE OF FLORIDA MICHAEL C. ANDERSON AR NO 17305 JrZ%A9M-a DATE: 08 05 20 i SCALE: 1/4"=1'-O" 1 SHEET S 1 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www. abdesigngroup.com AA #: 0003325 w 7 x IVHDIV. & ''LO' ST LUCIE COUNTY MASTER 'PA PROn=T# MODEL: EXPRESS SHINGLE GARAGE BWMG-,- f PAGE: J60 MPH EXP. ARCHfTECT. STATE OF FLORIDA [MCHAAsJG 0 6 2020 EL C. ANDEASON AR NO 17305 PRINT 8.3.20 DATE: MICALE: 1/4"=1' - 0" 8IMET PI