HomeMy WebLinkAboutENGINEERINGDIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 SAFETY LABELS PV-5.1 ATTACHMENT PLAN 5.1 PV-5.2 ATTACHMENT PLAN 5.2 PV-5.3 ATTACHMENT PLAN 5.3 PV-5.4 ATTACHMENT PLAN 5.4 PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN APPENDIXMODULE DATASHEET ARRAY WIRING BOX DATASHEET DISCONNECT DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY ADDRESS 5313 SUNSET BLVD, FORT PIERCE, FL 34982 US ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) UTILITY COMPANY FLORIDA POWER & LIGHT CO ELECTRICAL CODE 2017 NEC (NFPA 70) FIRE CODE 2018 NFPA 1 OTHER BUILDING CODES 2020 FL BUILDING CODE CONTRACTOR INFORMATION COMPANY EFFICIENT HOME SERVICES ADDRESS 9416 INTERNATIONAL CT, ST. PETTERSBURG, FL 32907 PHONE NUMBER (844) 778-8810 CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PV SYSTEM WITH NO ENERGY STORAGE DC RATING OF SYSTEM 10.23KW AC RATING OF SYSTEM 7.44KW AC OUTPUT CURRENT 31.0A INVERTER(S)31 X ENPHASE IQ7-60-2-US MODULE APTOS SOLAR DNA-120 330 ARRAY WIRING (1) BRANCH OF 16 IQ7-60-2-US MICROINVERTERS (1) BRANCH OF 15 IQ7-60-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.12(A) UTILITY SERVICE 120/240V 1Φ SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE 2% HIGH 33°C (91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) WIND SPEED 170 MPH (ASCE7-10) RISK CATEGORY II WIND EXPOSURE CATEGORY B GROUND SNOW LOAD 0 PSF P-153160 GRID-TIED SOLAR POWER SYSTEM5313 SUNSET BLVDFORT PIERCE, FL 34982PROJECT SUMMARY DOC ID:153160-188793-1 DATE:2/2/21 CREATOR: REVIEWER: REVISIONS PV-1 GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 3 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 5:12 (23°) SLOPED ROOF, 7 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 270° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 3:12 (14°) SLOPED ROOF, 9 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 90° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 5:12 (23°) SLOPED ROOF, 7 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 90° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 3:12 (14°) SLOPED ROOF, 8 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 270° AZIMUTH ROADWAY (N) TRANSITION BOX, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE (E) MAIN SERVICE PANEL (MSP), OUTDOOR (E) UTILITY METER, OUTDOOR (N) TRANSITION BOX, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE (N) VISIBLE, LOCKABLE, READILY-ACCESSIBLE AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER, OUTDOOR (N) AC COMBINER, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE P-153160 GRID-TIED SOLAR POWER SYSTEM5313 SUNSET BLVDFORT PIERCE, FL 34982SITE PLAN DOC ID:153160-188793-1 DATE:2/2/21 CREATOR: REVIEWER: REVISIONS PV-2 PV MODULE MICROINVERTER PM1-31 330W 16 IN BRANCH 15 IN BRANCH 1 2 3 4 5 6 7 JUNCTION BOX 1 2 JB1-2 AC COMBINER 3 CB1 20A CB2 20A C1 8 PV DISCONNECTF1-2 40A 4 SW1 60A AC GEC LOADS KWHR LOAD LINE KWHR LOAD LINE UTILITY METER (200A MSP W/200A MCB) 240/120V 1ɸ, 3W 9 10 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-31 31 APTOS SOLAR DNA-120 330 330W 304W 10.51A 10.02A 40.3V 32.9V -0.123V/°C (-0.31%/°C)20A INVERTERS REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-31 31 ENPHASE IQ7-60-2-US 240V NOT SOLIDLY GROUNDED 240W 1.0A 15.0A 48V 97.0% DISCONNECTS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG222NRB OR EQUIV.60A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB1-2 2 20A 240VAC F1-2 2 40A 0VAC SYSTEM SUMMARY BRANCH 1 BRANCH 2 INVERTERS PER BRANCH 16 15 MAX AC CURRENT 16A 15A MAX AC OUTPUT 3,840W 3,600W ARRAY STC POWER 10,230W ARRAY PTC POWER 9,434W MAX AC CURRENT 31A MAX AC POWER OUTPUT 7,440W DERATED AC POWER OUTPUT 7,440W NOTES THE DC AND AC CONNECTORS OF THE ENPHASE IQ7-60-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(D). MATING CONNECTORS SHALL COMPLY WITH NEC 690.33. 1 THE ENPHASE IQ7-60-2-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE. 2 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER NEC 690.12(B).3 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL3003 AND UL 9703. 4 DC PV CONDUCTORS ARE NOT SOLIDLY-GROUNDED. NO DC PV CONDUCTOR SHALL BE WHITE- OR GRAY-COLORED5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(A) AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC 250.166 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS 43.3V AT 0°C (0°C - 25°C) X -0.123V/C + 40.27V = 43.3V).7 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(2)(3)(C)8 POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, AT A LOCALLY-APPROVED CONNECTION POINT, USING LOCALLY-APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.12(A). 9 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72. GROUNDED CONDUCTOR SHALL BONDED INSIDE DISCONNECT PER NEC 250.24(B) AND NEC 250.24(C) 10 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT / CABLE OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING 1 1 12 AWG THWN-2, COPPER 0.5" DIA. PVC-40 2 20A 12 AWG THWN-2, COPPER 0.96 (33°C)1.0 16A 20A 30A 28.8A 90°C 30A 2 1 12 AWG THWN-2, COPPER 0.5" DIA. PVC-40 2 20A 12 AWG THWN-2, COPPER 0.96 (33°C)1.0 15A 18.75A 30A 28.8A 90°C 30A 3 1 6 AWG THWN-2, COPPER 0.75" DIA. PVC-40 3 40A 8 AWG THWN-2, COPPER 0.96 (33°C)1.0 31A 38.75A 75A 72A 75°C 65A 4 1 6 AWG THWN-2, COPPER 0.75" DIA. PVC-40 3 40A N/A 0.96 (33°C)1.0 31A 38.75A 75A 72A 75°C 65A REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE:GRID-TIED SOLAR POWER SYSTEMFORT PIERCE, FL 349825313 SUNSET BLVDPV-3 P-153160 02/02/21 SDT 153160 SINGLE-LINE DIAGRAM 1 PV-3 SINGLE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). C1 - AC COMBINER (ENPHASE IQ COMBINER+) SW1 - DISCONNECT (EATON DG222NRB ) MSP - MAIN SERVICE PANEL AC COMBINER PANEL (C1) ! WARNING ! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. NEC705.12(B)(2)(3)(C) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1) ! WARNING ! ELECTRIC SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC690.13(B) AC SOLAR DISCONNECT (SW1) PV SYSTEM DISCONNECT NEC690.13(B) AC DISCONNECT (SW1) MAXIMUM AC OPERATING CURRENT: 31.0A MAXIMUM AC OPERATING VOLTAGE: 240V NEC690.54 ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) ! WARNING ! DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM. NEC705.12(B)(3) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2017 NEC AND 2018 NFPA 1 WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). P-153160 GRID-TIED SOLAR POWER SYSTEM5313 SUNSET BLVDFORT PIERCE, FL 34982SAFETY LABELS DOC ID:153160-188793-1 DATE:2/2/21 CREATOR: REVIEWER: REVISIONS PV-4 ROOF PROPERTIES ROOF MATERIAL TRAPEZOIDAL METAL (1-4IN) SLOPE 5/12 (22.6°) MEAN ROOF HEIGHT 19.5FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL APTOS SOLAR DNA-120 330 DIMENSIONS (AREA)66.3IN X 39.4IN X 1.4IN (18.2 SQ FT) WEIGHT 41.9LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL S-5! SOLARFOOT, 0.75IN AIR GAP FASTENING METHOD EMBEDMENT IN ROOF DECKING WITH 4 FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1 AND 2) 24.0IN (ZONE 3) MAX. MOUNT SPACING 48.0IN (ZONES 1 AND 2) 24.0IN (ZONE 3) MAX. ALLOW. CANTILEVER 15.8IN (ZONES 1 AND 2) 7.9IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 7 41.9 293.2 MICROINVERTERS 7 1.1 7.6 LINEAR FEET OF RAIL 48 FT 0.5 24.0 ANCHORS 18 0.1 2.3 MISC. HARDWARE 11.4 11.4 TOTAL ARRAY WEIGHT 338.4 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 7 18.2 127.4 POINT LOAD (338.4 LBS / 18 ATTACHMENTS)18.8 LBS DIST. LOAD (338.4 LBS / 127.4 SQFT)2.66 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 4.0 FT = MAX(MIN(0.4 * 19.5 FT, 0.1 * 39.6 FT), 0.04 * 39.6 FT, 3 FT) P-153160 GRID-TIED SOLAR POWER SYSTEM5313 SUNSET BLVDFORT PIERCE, FL 34982ATTACHMENT PLAN DOC ID:153160-188793-1 DATE:2/2/21 CREATOR: REVIEWER: REVISIONS PV-5.1 ROOF PROPERTIES ROOF MATERIAL TRAPEZOIDAL METAL (1-4IN) SLOPE 5/12 (22.6°) MEAN ROOF HEIGHT 19.5FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL APTOS SOLAR DNA-120 330 DIMENSIONS (AREA)66.3IN X 39.4IN X 1.4IN (18.2 SQ FT) WEIGHT 41.9LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL S-5! SOLARFOOT, 0.75IN AIR GAP FASTENING METHOD EMBEDMENT IN ROOF DECKING WITH 4 FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1 AND 2) 24.0IN (ZONE 3) MAX. MOUNT SPACING 48.0IN (ZONES 1 AND 2) 24.0IN (ZONE 3) MAX. ALLOW. CANTILEVER 15.8IN (ZONES 1 AND 2) 7.9IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 7 41.9 293.2 MICROINVERTERS 7 1.1 7.6 LINEAR FEET OF RAIL 48 FT 0.5 24.0 ANCHORS 20 0.1 2.6 MISC. HARDWARE 12.0 12.0 TOTAL ARRAY WEIGHT 339.3 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 7 18.2 127.4 POINT LOAD (339.3 LBS / 20 ATTACHMENTS)17.0 LBS DIST. LOAD (339.3 LBS / 127.4 SQFT)2.66 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 4.0 FT = MAX(MIN(0.4 * 19.5 FT, 0.1 * 39.6 FT), 0.04 * 39.6 FT, 3 FT) P-153160 GRID-TIED SOLAR POWER SYSTEM5313 SUNSET BLVDFORT PIERCE, FL 34982ATTACHMENT PLAN DOC ID:153160-188793-1 DATE:2/2/21 CREATOR: REVIEWER: REVISIONS PV-5.2 ROOF PROPERTIES ROOF MATERIAL TRAPEZOIDAL METAL (1-4IN) SLOPE 3/12 (14.0°) MEAN ROOF HEIGHT 11.1FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL APTOS SOLAR DNA-120 330 DIMENSIONS (AREA)66.3IN X 39.4IN X 1.4IN (18.2 SQ FT) WEIGHT 41.9LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL S-5! SOLARFOOT, 0.75IN AIR GAP FASTENING METHOD EMBEDMENT IN ROOF DECKING WITH 4 FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1 AND 2) 24.0IN (ZONE 3) MAX. MOUNT SPACING 48.0IN (ZONES 1 AND 2) 24.0IN (ZONE 3) MAX. ALLOW. CANTILEVER 15.8IN (ZONES 1 AND 2) 7.9IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 8 41.9 335.1 MICROINVERTERS 8 1.1 8.6 LINEAR FEET OF RAIL 54 FT 0.5 27.0 ANCHORS 16 0.1 2.1 MISC. HARDWARE 10.0 10.0 TOTAL ARRAY WEIGHT 382.8 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 8 18.2 145.6 POINT LOAD (382.8 LBS / 16 ATTACHMENTS)23.9 LBS DIST. LOAD (382.8 LBS / 145.6 SQFT)2.63 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 4.0 FT = MAX(MIN(0.4 * 11.1 FT, 0.1 * 39.6 FT), 0.04 * 39.6 FT, 3 FT) P-153160 GRID-TIED SOLAR POWER SYSTEM5313 SUNSET BLVDFORT PIERCE, FL 34982ATTACHMENT PLAN DOC ID:153160-188793-1 DATE:2/2/21 CREATOR: REVIEWER: REVISIONS PV-5.3 ROOF PROPERTIES ROOF MATERIAL TRAPEZOIDAL METAL (1-4IN) SLOPE 3/12 (14.0°) MEAN ROOF HEIGHT 11.1FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL APTOS SOLAR DNA-120 330 DIMENSIONS (AREA)66.3IN X 39.4IN X 1.4IN (18.2 SQ FT) WEIGHT 41.9LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL S-5! SOLARFOOT, 0.75IN AIR GAP FASTENING METHOD EMBEDMENT IN ROOF DECKING WITH 4 FASTENERS MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1 AND 2) 24.0IN (ZONE 3) MAX. MOUNT SPACING 48.0IN (ZONES 1 AND 2) 24.0IN (ZONE 3) MAX. ALLOW. CANTILEVER 15.8IN (ZONES 1 AND 2) 7.9IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 9 41.9 377.0 MICROINVERTERS 9 1.1 9.7 LINEAR FEET OF RAIL 61 FT 0.5 30.3 ANCHORS 17 0.1 2.2 MISC. HARDWARE 10.9 10.9 TOTAL ARRAY WEIGHT 430.1 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 9 18.2 163.8 POINT LOAD (430.1 LBS / 17 ATTACHMENTS)25.3 LBS DIST. LOAD (430.1 LBS / 163.8 SQFT)2.63 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 4.0 FT = MAX(MIN(0.4 * 11.1 FT, 0.1 * 39.6 FT), 0.04 * 39.6 FT, 3 FT) P-153160 GRID-TIED SOLAR POWER SYSTEM5313 SUNSET BLVDFORT PIERCE, FL 34982ATTACHMENT PLAN DOC ID:153160-188793-1 DATE:2/2/21 CREATOR: REVIEWER: REVISIONS PV-5.4 P-153160 GRID-TIED SOLAR POWER SYSTEM5313 SUNSET BLVDFORT PIERCE, FL 34982ATTACHMENT DETAILS DOC ID:153160-188793-1 DATE:2/2/21 CREATOR: REVIEWER: REVISIONS PV-6 GENERAL NOTES 1 ACCESS AND SPACING REQUIREMENTS SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESSION FROM THE ROOF. THE AHJ SHALL BE PERMITTED TO REDUCED OR MODIFY ROOF ACCESS BASED UPON FIRE DEPARTMENT VENTILATION PROCEDURES OR ALTNERATIVE METHODS THAT ENSURE ADEQUATE FIRE DEPARTMENT ACCESS, PATWAYS, AND SMOKE VENTILATION. (NFPA 1 11.12.2.2.1) 2 NOT LESS THAN TWO 36 IN. (914 MM) WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM GUTTER TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLAN WITH A PV ARRAY, A 36 IN. (914 MM) WIDE PATHWAY FROM GUTTER TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PV ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. (NFPA 1 11.12.2.2.2.1) 3 FOR PV ARRAYS OCCUPYING UP TO 33 PERCENT OF THE PLAN VIEW ROOF AREA, A MINIMUM 18 IN. (457 MM) PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. FOR PV ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW ROOF AREA, A MINIMUM OF 36 IN. (914 MM) PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. (NFPA 1 11.12.2.2.2.2) ROOF ACCESS POINT PV MODULES INSTALLED ON ROOF WITH QUICK MOUNT PV QRAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 5/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE APTOS SOLAR DNA-120 330 IS TYPE 1. 3.0 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.12.2.2.2.1 3.0 FT. WIDE SMOKE-VENTILATION SETBACK, PER NFPA 1 11.12.2.2.2.2 PV MODULES INSTALLED ON ROOF WITH QUICK MOUNT PV QRAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 3/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE APTOS SOLAR DNA-120 330 IS TYPE 1. ROADWAY TOTAL PLAN VIEW ARRAY AREA IS 541.0 SQ.FT, WHICH REPRESENTS 29.9% OF TOTAL PLAN VIEW ROOF AREA (1807.4 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. P-153160 GRID-TIED SOLAR POWER SYSTEM5313 SUNSET BLVDFORT PIERCE, FL 34982FIRE SAFETY PLAN DOC ID:153160-188793-1 DATE:2/2/21 CREATOR: REVIEWER: REVISIONS PV-7 DNA-120330W l 325W l 320WHigh-efficiency, Half-cut cell panelMaximize Energy ProductionResilient in extreme weather conditions 5400 Pa snow load175 mph wind load All-black design for pristine aesthetics25 year warantyExtended reliabilityAdvanced technology boosts power generationaptos solar technologyTMOur DNA Half-cut Cell Series impressively combines advanced technologies to maximize performance. Our patented DNA, Dual Nano Absorber, technology allows for panel operate at high efficiencies with excellent performance in high temperature environments. wwww.aptossolar.com l info@aptossolar.comALL-BLACK DESIGNULRLISTEDProduct CertificationsFactory Certifications9001140011800125 Year Linear Performance Warranty 1 year10 years25 years93.1%84.8%90.7%80.2%Aptos WarrantyStandard Warranty98%97%ELECTRICAL SPECIFICATIONS (+3%/-0%)STCrated output Pmpp(W)Open Circuit Voltage Vvoc(V)Short Circuit Current lsc(A)Rated Voltage Vmmp(V)Rated Current lmmp(A)32540.1010.4332.719.9333040.2710.5132.9110.02Standard Test Conditions for front-face of panel:1000 W/m , 25 C, measurement uncertainty <3%2TEMPERATURE COEFFICIENTSTEST OPERATING CONDITIONSMECHANICAL PROPERTIESTemperature Coefficients Pmpp-0.40%/ CTemperature Coefficients lsc+0.046%/ CTemperature Coefficients Voc-0.306%/ CNormal Operating Cell Temperature (NOCT)45 CCell TypeGlassFrameJunction BoxDimensionOutput CableWeightMonocrystallineLow Iron, TemperedAnodized Aluminum AlloyIP671684 x 1002 x 35mm4mm (EU)12AWG, 39.37in(1000mm)41.9lbs.(19kg)I-V CURVEMaximum Series FuseMaximum System VoltageMaximum Load Capacity (Per UL1703)Fire Performance Class20A1,500 VDC (UL&IEC)5,400PA Snow Load175mph Wind RatingClass C/Type 11360mm32039.9210.3532.519.8421684mm1002mmCable Length1200mm860mm952mmaptos solar technologyTMDNA-120BLACK FRAME, BLACK BACKSHEETHIGH EFFICIENCY, HALF-CUT CELL PANELMODULE DIMENSIONS3140 De La Cruz Blvd., Ste. 200 Santa Clara, CA 95054www.aptossolar.com l info@aptossolar.comDNA-120-MF23-XXXWRESIDENTIAL l COMMERCIALDNA-120-MF23-320W DNA-120-MF23-325WDNA-120-MF23-330WNumber of Modules per Pallet30Pallet Dimensions (mm)1720X 1140 X 1140 Pallet weight (kg)PACKAGING CONFIGURATIONNumber of Pallets per 40ft HQ Container26620Container weight (kg)1612035mmAptos Solar Technology reserves the right to make specification changes without noticeULRLISTEDPRODUCT CERTIFICATIONSModule Efficiency18.96%19.25%19.54% The Enphase IQ Combiner™ with Enphase IQ Envoy™ consolidates interconnection equipment into a single enclosure and streamlines PV installations by providing a consistent, pre-wired solution for residential applications.Enphase IQ Combiner(X-IQ-AM1-240-B)To learn more about Enphase offerings, visit enphase.comData SheetEnphase NetworkingSmart• Includes IQ Envoy for communication and control• Flexible networking supports Wi-Fi, Ethernet, or cellularSimple• Three pre-installed 20 A / 240 VAC circuit breakers• Provides production metering and optional consumption monitoring.Reliable• Durable NRTL-certified NEMA type 3R enclosure• Five-year warrantyTo learn more about Enphase offerings, visit enphase.com© 2017 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. 2017-08-17MODEL NUMBERIQ Combiner X-IQ-AM1-240-BIQ Combiner with Enphase IQ Envoy™ for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional consumption monitoring (+/- 2.5%).ACCESSORIES (order separately)Enphase Mobile Connect™CELLMODEM-03 (4G / 12-year data plan)CELLMODEM-01 (3G / 5-year data plan)Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.)Consumption Monitoring CTCT-200-SPLITSplit core current transformers enable whole home consumption metering (+/- 2.5%).ELECTRICAL SPECIFICATIONSRatingContinuous dutySolar branch circuit breakersThree 2-pole 20 A/240 VAC DIN rail-mounted breakersMaximum system voltage240 VACRated output current48 ARated input current, each input16 AMaximum fuse/circuit breaker rating (output)60 AProduction Metering CT200 A solid core pre-installed and wired to IQ EnvoyMECHANICAL DATADimensions (WxHxD)38.0 x 38.7 x 20.3 cm (15.0” x 15.3” x 8.0”)Weight5.1 kg (11.2 lbs)Ambient temperature range-40º C to +46º C (-40º to 115º F)CoolingVented, natural convection, plus heat shieldEnclosure environmental ratingOutdoor, NRTL-certified, NEMA type 3R, polycarbonate constructionWire size14 to 6 AWG copper conductors for branch inputs.14 to 4 AWG copper conductors for combined output.Follow local code requirements for conductor sizing.AltitudeTo 2000 meters (6,560 feet)INTERNET CONNECTION OPTIONSIntegrated Wi-Fi802.11b/g/nEthernet802.3, Cat5E (or Cat 6) UTP Ethernet cable - not included CellularOptional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) - not includedCOMPLIANCECompliance, CombinerUL 1741 Compliance, IQ EnvoyUL 916CAN/CSA C22.2 No. 61010-1 47 CFR, Part 15, Class B, ICES 003IEC/EN 61010-1:2010,EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2Metering: ANSI C12.20 accuracy class 0.5Enphase IQ Combiner The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency.Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software.IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+MicroinvertersTo learn more about Enphase offerings, visit enphase.comData SheetEnphase MicroinvertersRegion: AMERICASEasy to Install• Lightweight and simple• Faster installation with improved, lighter two-wire cabling• Built-in rapid shutdown compliant (NEC 2014 & 2017)Productive and Reliable• Optimized for high powered 60-cell and 72-cell* modules• More than a million hours of testing• Class II double-insulated enclosure• UL listedSmart Grid Ready• Complies with advanced grid support, voltage and frequency ride-through requirements• Remotely updates to respond to changing grid requirements• Configurable for varying grid profiles• Meets CA Rule 21 (UL 1741-SA)* The IQ 7+ Micro is required to support 72-cell modules.1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.To learn more about Enphase offerings, visit enphase.com© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-USIQ7PLUS-72-2-US / IQ7PLUS-72-B-USCommonly used module pairings¹235 W - 350 W +235 W - 440 W +Module compatibility60-cell PV modules only60-cell and 72-cell PV modulesMaximum input DC voltage48 V60 VPeak power tracking voltage27 V - 37 V27 V - 45 VOperating range16 V - 48 V16 V - 60 VMin/Max start voltage22 V / 48 V22 V / 60 VMax DC short circuit current (module Isc)15 A15 AOvervoltage class DC portIIIIDC port backfeed current0 A0 APV array configuration1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ 7 MicroinverterIQ 7+ MicroinverterPeak output power250 VA295 VAMaximum continuous output power240 VA290 VANominal (L-L) voltage/range²240 V / 211-264 V208 V / 183-229 V240 V / 211-264 V208 V / 183-229 VMaximum continuous output current1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V)Nominal frequency60 Hz60 HzExtended frequency range47 - 68 Hz47 - 68 HzAC short circuit fault current over 3 cycles5.8 Arms5.8 ArmsMaximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC)Overvoltage class AC portIIIIIIAC port backfeed current0 A0 APower factor setting1.01.0Power factor (adjustable)0.85 leading ... 0.85 lagging0.85 leading ... 0.85 laggingEFFICIENCY@240 V@208 V@240 V@208 VPeak efficiency97.6 %97.6 %97.5 %97.3 %CEC weighted efficiency97.0 %97.0 %97.0 %97.0 %MECHANICAL DATAAmbient temperature range-40ºC to +65ºCRelative humidity range4% to 100% (condensing)Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter)Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US)Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors:- PV2 to MC4: order ECA-S20-S22- PV2 to UTX: order ECA-S20-S25Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket)Weight1.08 kg (2.38 lbs)CoolingNatural convection - No fansApproved for wet locationsYesPollution degreePD3EnclosureClass II double-insulated, corrosion resistant polymeric enclosureEnvironmental category / UV exposure ratingNEMA Type 6 / outdoorFEATURESCommunicationPower Line Communication (PLC)MonitoringEnlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy.Disconnecting meansThe AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.ComplianceCA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions.Enphase IQ 7 and IQ 7+ Microinverters QRail — Fully Integrated Mounting and Racking SystemThe QRail Series is a strong and versatile solar array mounting system that provides unrivaled benefits to solar designers and installers. Combined with Quick Mount PV’s industry-leading waterproof mounts, QRail offers a complete racking solution for mounting solar modules on any roof. QRail, together with Quick Mount PV’s waterproof mounting products, provides the benefit of a single-sourced, seamlessly integrated rooftop installation that works with all roof types — composition/asphalt shingles, flat or curved tile, metal shingle, shake, slate and low slope roofs. The QRail system also works with any roof attachment system for maximum flexibility.Comprehensive, One-Source SolutionFast, Simple Installation: It Just ClicksThe QRail system provides an integrated electrical bonding path, ensuring that all exposed metal parts and the solar module frames are electrically connected. All electrical bonds are created when the components are installed and tightened down.Fully Integrated Electrical BondingQClick TechnologyThe universal mid and end clamps use patented QClick technology to simply “click” into the rail channel and remain upright, ready to accept the module. The pre-assembled clamps fit virtually all module frames and require no extra hardware, eliminating pre-loading and reducing installation time.Superior Strength and VersatilityQRail is engineered for optimal structural performance. The system is certified to UL 2703, fully code compliant and backed by a 25-year warranty. QRail is available in Light, Standard and Heavy versions to match all geographic locations. QRail is compatible with virtually all modules and works on a wide range of pitched roof surfaces. Modules can be mounted in portrait or landscape orientation in standard or shared-rail configurations.STANDARDLIGHT123click!click!2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL END CLAMP2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL BONDED MID CLAMPQRail’s innovative internal QSplice installs in seconds, requiring no tools or screws. Simply insert QSplice into the rail and slide the other rail on to create a fully structural, bonded splice. An external splice is also available.QSplice TechnologyQSPLICEHEAVYQRails come in two lengths —168 inches (14 ft) and 208 inches (17.3 ft)™™231Mill and Black FinishInstalls in seconds — no tools or hardware requiredInstalling is as easy as 1-2-3Easily design array configurations with the QDesign software application. Generate complete engineering reports and calculate a precise bill of materials for all the mounting, racking and accessories needed for a complete solar array.™ The right way to attach almost anything to metal roofs! SolarFoot Features:Manufactured in the U.S.A. from certified raw materialFabricated in our own ISO 9001:2015 certified factoryAll aluminum and stainless components 25yr limited warrantyCompatible with all commercial L-Foot products on the marketFactory applied 40-year isobutylene/isoprene crosslink polymer sealant for reliable weathertightness Sealant reservoir to prevent over-compression of sealantLoad-to-failure tested Normal to Seam by a nationally accredited laboratory on numerous metal roof materials and substratesFour points of attachment into structure or deck with tested holding strength for engineered applicationsIntegrated M8-1.25x17mm stud and M8-1.25 stainless steel hex flange nut included888-825-3432 | www.S-5.com | Introducing the new SolarFoot™ for exposed fastener metal roofing with the strength, testing, quality, and time-proven integrity you expect from S-5!. The SolarFoot provides an ideal mounting platform to attach the L-Foot (not included) of a rail-mounted PV system to the roof. This solution is The Right Way to secure rail-mounted solar systems to exposed fastener metal such as AG-Panel or R-Panel. NEW PRODUCTSolarFoot™SolarFootTM Mounting for Exposed Fastener RoofingFastener SelectionTo source fasteners for your projects, contact S-5!When other brands claim to be “just as good as S-5!”, tell them to PROVE IT.The SolarFoot is a simple, cost-effective pedestal for L-Foot (not included) attachment of rail-mounted solar PV. The unique design is compatible with all rail producer L-Foot components. The new SolarFoot assembly ensures a durable weathertight solution for the life of the roof. Special factory applied butyl co-polymeric sealant contained in a reservoir is The Right Way, allowing a water-tested seal. Stainless integrated stud and hex flange lock-nut secure the L-Foot into position. A low center of gravity reduces the moment arm commonly associated with L-Foot attachments. Direct attachment of the SolarFoot to the structural member or deck provides unparalleled holding strength.*Fasteners sold separately. Fastener type varies with substrate. Contact S-5! on how to purchase fasteners and obtain our test results. L-Foot also sold separately.Distributed by:SolarFoot Advantages:Exposed fastener mounting platform for solar arrays attached via L-Foot and RailsWeatherproof attachment to exposed fastener roofingButyl sealant reservoir provides long-term waterproof sealM8-1.25x17mm stud with M8 hex flange nut for attachment of all popular L-Foot/rail combinationsTool: 13 mm Hex Socket or ½” Hex SocketTool Required: Electric screw gun with hex drive socket for self-tapping screws. Low Center of Gravity reduces moment arm commonly associated with L-Foot/Rail solar mounting scenariosAttaches directly to structure or deck for optimal holding strengthS-5! Recommended substrate-specific (e.g. steel purlin, wood 2x4, OSB, etc.) fasteners provide excellent waterproofing and pull- out strength Fastener through-hole locations comply with NDS (National Design Specification)for Wood ConstructionS-5!® Warning! Please use this product responsibly!The independent lab test data found at www.S-5.com can be used for load-critical designs and applications. Products are protected by multiple U.S. and foreign patents. For published data regarding holding strength, fastener torque, patents, and trademarks, visit the S-5! website at www.S-5.com. Copyright 2017, Metal Roof Innovations, Ltd. S-5! products are patent protected. Copyright 2017, Metal Roof Innovations, Ltd. Version 102017 .50in 1.00in 1.50in .50in 1.83in 3.17in 2.00in 3.67in (4x)8mm.315in .66in 17mm.67in 1.32in 1.39in .32in Factory AppliedButyl SealantM8-1.25 Stainless Steel Threaded StudMetal to Metal: 1/4-14 Self Drilling Screw 1-1/2" to 2-1/2"Metal to Wood: 1/4-14 Type 17 AB Milled Point 1-1/2" to 2-1/2"