Loading...
HomeMy WebLinkAboutEngineer Drawings 2BOX COLUMN ATTACHMENT 5"2" 2X22"2" .044" .044" .116" .05" 2X5 2"1".046" .044" 1X2 2X44"2" .044" .10" 3X33"3" .090"8"2" .224" .072" 2X86"2" .12" .05" 2X6 7"2" .12" .055" 2X7 2X3 SNAP3"2" .05" .040" 1"1"1" SQ. PICKET 2X33"2" .05" .050"2X2 SNAP 2" .046"2"3X23"2" .05" .050" 4X44"4" .090" 1/3SHEET :REVISIONSBYDATE:APPROVED BY: M.H1-1-2021P.E.# 62565MYOUNG - HO KIM P.E.2653 BACCARAT DRCOOPER CITY, FL. 33026TEL: (954) 559-72474" TO 8"2" LB CONNECTION USE #12 SMS @ 24"O.C./ TOP & BOT.FOR 2X7 OR SMALLER AND #14 SMS @ 24"O.C./ TOP & BOT. FOR2X8 ENGINEER SEAL: ALUMINUM LAP COLUMNS DIMENSIONS 2X2 "C" CHANNEL 2 1/8"2 1/8".064" 2X4X.125"4"2" .125" 2X5X.125"5"2" .125"S C R E E N E D B A L C O N Y R A I L I N G1X2/1X3 ATTACHED W/ 14"x3" STAINLESS STEELTAPCON @ 24" O.C. MAX. 2X2X2X18" ANGLE W/(3) #14 TEK & (1) 14"X3" STAINLESS STEEL TAPCON(2" MIN. EMBEDMENT) COLUMN ATTACHMENT TO CONCRETE FOR 2X5 OR GREATER COLUMN, ADD ANOTHER 2X2X2X18" ANGLE W/(3) #14 TEK & (1) 14"x3" STAINLESS STEEL TAPCON EACH SIDE(MIN 2" EMBEDMENT INTO CONC.) COLUMN ATTACHMENT TO CONRETE (4) #10 S.M.S. FROMINSIDE FACE OF COLUMN INTO SCREW SPLINES OF2x2 or 2X3 (1-12: EMBEDMENT MIN.) CHAIR RAIL CONNECTION 2X2/2X3 SNAP RAILING CHAIR RAIL CONNECTION (OPTIONAL) COLUMN "C" CHANNEL W/ (3) #10STAINLESS SMS EA. SIDE OF CHANNEL 2X2/2X3 SNAP RAILING COLUMN GENEREAL NOTES 1. All details provided comply with FBC 2020 7th Edition & ASCE 7-10.2. Ultimate Design Wind Speed :170 mph, Exposure C, & Category I.3. All concrete (existing & new) shall have a min. compressive strength of 2500 psi. 4. All concrete anchors supporting columns shall have min. 212" embedment regardless of Spec details.5. Interpolation is allowed when using beam and column tables.6. Existing footers may be used if they are in satisfactory structural condition. If incorporating in exist. slab dowel to new footers with #5 12" rebar dowels @ 24" O.C. epoxyed into the existing footers with min emb. of 6", with Simpson Strong-Tie epoxy or equivalent.7. All conc. anchors shall be Simpson Strong-Tie Wedge, Tapcon w/ min ultimate ten. strength of 60ksi8. Contractor must insulate aluminum members from dissimilar metals to prevent electrolysis.9. All Aluminum structural components shall be of 6005-T5 or 6061-T6 alloy and be certified to comply with all applicable alloy specifications. Maximum house overhang cantilever shall be 2ft. 10. Fasteners must have min 12" head or be provided with 12" dia. washers min.11. Calculations based on using 18/14 screen mesh, if 20/20 mesh is used, tables shall be revised.12. Bolts and all fasteners shall be non-magnetic coated stainless for corrosion resistance. 3X3X 1 8" 1X2/1X3 1X2/1X3 2X2X18 CLIP ANGLESW/ (1) 14"X3" TAPCON& (3) #10 STAINLESS TEK SCREWS CORNER COLUMN (OPTION 1) 1X2 / 1X3 42"2X2 OR 2X3 SNAP RAIL COLUMN TYPICAL SCREENED BALCONY SECTION 14"X3" STAINLESS TAPCONS @ 24"O.C. FOR CONCRETE OR 14"X 3" LAGS @ 18" O.C. FOR WOOD 1X2 OR 1X3 EXIST. HOUSE CBS/WOOD FRAME WALL OR COLUMN(4) #10 S.M.S. FROM INSIDE FACE OF1X2/1X3 INTO SCREW SPLINES OF2X2/2X3 (112" EMBEDMENT MIN.) EXIST. WOOD/CONC.HOUSE ROOF (2) #10 SMS 14"X3" STAINLESS TAPCON @ 24 O.C. 2X2/3X3 SNAP SCREENED BALCONY ATTACHMENT 3" (MIN.) 3X3X.125 OR 4X4X.125 COL. 2X2X2X18" CLIP ANGLEW/(3) #14 SMS EA. SIDE OR(2) 14" STAINLESS STEEL THRUBOLTS (1) 14"X3" STAINLESS STEEL TAPCON(2" MIN. EMBEDMENT) 4X4X1 8"OR 1X2 OR 1X3 3"1".046" .044" 1X3 OUTSIDE 14"X3" STAINLESS STEEL TAPCON @ 24 O.C. 3 7/8" MAX SPACING 14"X3" STAINLESS STEEL TAPCON 14"X3" STAINLESS STEEL TAPCONS @ 24 O.C. 2X2X18" CLIPANGLES W/ (2)#14 STAINLESSSMS EA. ANGLE. 1" SQUARE PICKET COLUMN 1X2/1X3 COLUMN ATTACHMENT TO CONCRETE SLAB 14"X3" STAINLESS STEEL TAPCONS @ 24 O.C. TO CONCRETE OR 14"X3" LAGS TO WOOD 2X2X1/8" CLIP ANGLEW/(2) #14 STAINLESS SMS TO COL.&(1)14"X3" STAINLESS STEEL TAPCON EA. ANGLECOLUMN1X2/1X3 1X2/1X3 ATTACHED W/ 14"X3" STAINLESS STEEL TAPCON @ 24" O.C. MAX. COLUMN ATTACHMENT TO CONCRETE 2X2X2X18" CLIP ANGLEW/(3) #14 STAINLESS SMS EA. SIDE OR(2) 14" STAINLESS STEEL THRUBOLTS USE 2X2X18" ANGLE W/4#12 TEK SCREWS TO COL.AND W/4 #12 TEK SCREWSTO BACK OF RAILING 1 3/4" SQ. INSERT 1 3/4"1 3/4"3/16" .040" 3/4"3/4"3/4" SQ. PICKET 2X33"2" .0357" .09" 1X2 OR 1X3 42"2X2 OR 2X3 CHAIR RAIL COLUMN REINFORCED SCREENED BALCONY SECTION OUTSIDE 14"X3" STAINLESS STEEL TAPCON @ 24 O.C. USE 2x2x18" ANGLE W/4#12 TEK SCREWS TO COL.AND W/4 #12 TEK SCREWSTO BACK OF RAILING 1X2 OR 1X3 W/ #10 SMS TO EACH PICKET AND 8" O.C. TO CHAIR RAIL 1X2 2X5 OR GREATER COLUMN 2X2X2X18" ANGLESW/(3) #14 TEKEACH SIDE (1) 14"x3" STAINLESS STEEL TAPCON EACH SIDE(MIN 2" EMBEDMENT INTO CONC.)4" THICK CONCRETE SLAB (MINIMUM) SEE FOUND. DETAIL/SPECIFIC DRAWING FOR 2X5 AND GREATER COLUMN, ADDANOTHER ANGLE W/(3) #14 TEK AND (1) 14"X212" STAINLESS STEEL TAPCON EACH SIDE (4) #10 S.M.S. FROMINSIDE FACE OF COLUMN INTO SCREW SPLINES OF2x2 or 2X3 (1-12: EMBEDMENTMIN.) (1) 14"X3" STAINLESS STEEL TAPCON(2" MIN. EMBEDMENT) (4) #10 S.M.S. FROMINSIDE FACE OF COLUMN INTO SCREW SPLINES OF2x2 or 2X3 (1-12: EMBEDMENTMIN.) 2X2 1X2 1X2 2X2X18 CLIP ANGLESW/ (1) 3 8"X 4" TAPCON& (3) #10 TEK SCREWS CORNER COLUMN (OPTION 2)F. B. C. 2020 ASCE 7-10 170 MPH EXPOSURE "C" CATEGORY I