Loading...
HomeMy WebLinkAboutGutierrez - Engineering Letter.pdfDATE: 1/27/21 ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8i50 www.floridaeugineeringandtesting.com 250 S.W.13th Avenue Pompano Beach, FL 33069 JOB ORDER M 21-1341 CLIENT: Alliance Group ADDRESS: 615 NW Enterprise Drive Port Saint Lucie, FL 34986 PROJECT: Gutierrez Residence Flat Wood Roof Deck ADDRESS: 6009 S Indian River Drive Fort Pierce, FL 2020 FBC/ASCE 7-16 DESIGN PRESSURE CALCULATIONS Proiect Information: Height = 20' Exposure: D Basic/lAtimate Wind Speed: Vwt=170 mph Length = 84' Category: II Nominal Wind Speed: Vaud=Vwt*40.6 Width = 44' Slope: < 7' (asd = allowable strength design) Parapet Wall: < 3' Residential Kz =1.08, Kzt =1.0, Kd = 0.85 For multiple deck condition, the most conservative dimensions were utilized for design talcs. Desisn Calculations: Velocity Pressure: q = 0.00256*KzKztKdKeV2 Velocity Pressure (,it): q=0.00256(1.08)(1.0)(0.85)(1.0)(170)2 = 67.92 psf Velocity Pressure (,sd): q=0.00256(1.08)(1.0)(0.85)(1.0)(170*�0.6)2 = 40.75 psf ASCE 7-16, FIGURE C30-1 "Four Possible Scenarios for Roof Zones" ❑ ® ❑ ❑ 0 J L � 1 L r I Qj -1 O O JD O IM Buildings with least horizontal Buildings with least horizontal Buildings with least horizontal Buildings with largesthorhontal dimension greater than 2.4h dimension greater than 1.2h but dimension less than 1.2h and dimension less than 1.2h less than 2.4h largest horizontal dimension greater than 1.2h Figure 3a3-2A o n o asl For calculating roof zone dimensions only. Refer to Diagrams to the Leftfor Applicable Zones for this Roof Length = 84' Width = 44' 1.2h = 24' 2.4h = 48' 0.6h =12' 0.2h = 4' Effective Wind Area: <10ft2 For parapet height three feet (3') or larger, zone three (3) shall be treated as zone two (2). V 1 `%i Quality A .4 x trance Page £,1/27/21, Job Order # 21-1341 Alliance Group Gutierrez Residence - Flat Wood Roof Deck 6009 S Indian River Drive; Fort Pierce, FL: External Pressure Coefficient: GCP 1' = -0.9 GCPl = -1.7 GCP2 = -2.3 GCP3 = -3.2 Not Applicable Design Pressures Based on Vasd: FLO A Internal Pressure Coefficient: GCPi = 0.18 1) Field (Interior) Pl' = 40.75*[(-0.9) — (0.18)] = -44.0 psf Not Applicable 1) Field (Exterior) PI = 40.75*[(-1.7) — (0.18)] = -76.6 psf 2) Perimeter P2 = 40.75* [(-2.3) — (0.18)] = -101.1 psf 3) Comers P3 = 40.75* [(-3.2) — (0.18)] = -137.7 psf Attachment Requirements Per RAS-117: Based on the requirements of Florida Product Approval # FL10264-R15, Appendix 1, pg 7 of 63, System No. W-35, with a maximum design pressure of-82.5psf; the following are our recommended fastening patterns to attach the proposed UltraPly TPO membrane bonded to UltraPly TPO InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps through the preliminarily attached thermal barrier and/or insulation to the min. 19/32" plywood deck (attached to structural supports per product approval) utilizing approved Firestone Heavy Duty Fasteners and UltraPly TPO InvisiWeld Plates (see zone diagram): Pl' Field (Interior) : 6" o.c. @ laps, in rows spaced @ a max. of 60" o.c. Not Applicable Pl Field (Exterior) : 6" o.c. @ laps, in rows spaced @ a max. of 60" o.c. P2 Perimeter : 6" o.c. @ laps, in rows spaced @ a max. of 48" o.c. P3 Comers : 6" o.c. @ laps, in rows spaced @ a max. of 35" o.c. Notes: • Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). • All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2020 Edition. • Wind load calculations based on ASCE 7-16, 2020 FBC, and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. • All work shall be inspected by our field engineer (or authorized representative) or a building department inspectpptV% gwRR iance with specifications. :��ENSf Sincerely, Z 77Zf 0 Lu Troy Bishop, P.E.; o`:. S1nrE Florida En eerin estiia P' G�' Florida Reg. No. 76i3J FS Certificate ofAuthorizafl6n 1p, bbl�3