Loading...
HomeMy WebLinkAboutInspection Docs Planning Development Services Building&Code Regulation Division ® 2300 Virginia Ave IMM"IM; D Fort Pierce,FL 34982 772-462-2112 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT CONSTRUCTION SGRL TREATMENT PERMIT #:�70q' (--Z,6D JOB ADD ESS: -Pj&K'IW-ron L BUILDER/CONTRACTOR: a -rAl PEST CONTROL CONTRACTOR: EVICT-A-BUG TERMITE&PEST CONTROL INC. PEST- CONTROL LICENSE #: JBI75775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: 3 Chemicals used: BASELINE Percentage of solution: •05% Total gallons used: , b Date of Treatment: Time of Treatment: Footing Slab 1st Treatment 1st Treatment Re-Treat Re-Treat DrivewayPools 1st Treatment _ist Treatment Re-Treat Re-Treat Other Perimeter for Final pection 15t Treatment �` J Re-Treat �9 /7' Signature of Exterminator Date Note. There must be a completed rnrm for each requlred treatment or re-treatment and this form must be on the fob site to be picked up by the inspector at time of each Inspectlon or the scheduled Inspection will fall and a re-Inspection fee charged, Fj3(Cj04.2.G Cerffr7cate of Protective Treatment for prevention of termites A weather resistant jobsite posting board shall be provided to receive dupllcate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is Issued to and another copy for the bullding permit Arles The Treatment Certlflcate shall provide the product used, Identity of the appllcator, time and date of the treatment,site location, area treated,chemical used,percent concentration and number of gallons used, to establish a verltlable record of protective treatment if the soil chemical barrier method for termite prevention Is used, final exterior treatment shall be completed prior to final bullding approval. St Lucia County requires for the final inspection for CO,a Permanent Stocker to be placed on the e0ectdcall panel box cover, listing alli the treatments and dates of apPliications. Revised 7/24/2014 I. i Soil Nuclear Gauge Client: Project: ---Report Date:513.1/2017 American Pools&Spas 14-2337.00 Test Method:ASTM D 6938 7320 Narcoossee Rd American Pools-Various Projects �fRNAT��P Part St.Lucia Orlando, FL FBPE CA#4930 - 521 NW Enterprise Drive Port St.Lucie,FL 34986 Phone:772-924-3575 1 Fax:772-924-3580 Test Results Optimum Maximum In Place In Place Probe Min/Max Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Comp. Test# Of Date Proctor ID Method Classification N (pef) N (pcf) (in) Compaction N Remark • 384 5/31/17 P-8 N/A 12.3 106.1 9.2 107.6 12 101 98/105 Pass 385 5131/17 P-8 N/A 12.3 106.1 9.7 106.8 12 101. 98/105 Pass 386 5/31/17 1 P-8 N/A 12.3 106.1 9.6 107.2 12 101 1 98/105 Pass 387 5/31/17 1 P-8 NIA 12.3 106.1 9.8 106.8 12 101 1 98/105 Pass Test Information Gauge Test# Test Location Elevation Reference Make I Model/SN Field Technician 384 Pool Deck:6799 Dickinson Terrace,Port St Lucie,West side of pool deck(PERMIT NO. 0-1 Troxler 3430 24039 Grimes,John 1704-0260 385 Pool Deck:6799 Dickinson Terrace,Port St Lucie,East side of pool deck(PERMIT NO. 0-1 Troxler 3430 24039 Grimes,John • 1704-0260) 386 Pool Deck:6799 Dickinson Terrace,Port St Lucie,North side of pool deck(PERMIT NO. 0-1 Troxler 3430 24039 Grimes,John 1704-0260) fi 387 Pool Deck:6799 Dickinson Terrace,Port St Lucie,South side of pool deck(PERMIT NO. 0-1 Troxler 3430 24039 Grimes,John 1704-0260 Remarks Comments Pass:Tests results comply with specifications Tests are"Direct Transmission"(Method A)unless probe depth is noted as "Backscatter".Gauge calibration data on file with the testing agency. 0 C • , �„ - �r'1 ,7 ;,—� a 05/3 f/26.fJ E'E�l �;��' I f4 0l Donald W. Moler,P;E. : LU JUN 19 '20117 Professio 1�4glneer 5 °RSfate of Florida ;` �_ Lucie CouI- ea`~ °pa�rs�t�at'1�t I 1�� O ztn( ) Test Reports shall not be reproduced,except in full,without the written approval of GFA International Inc. Page 1 of 1 Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verged on any electronic copies.