Loading...
HomeMy WebLinkAboutSite planI t$�4-r - 1g.���I1fCStLGt ' "✓�C.ra1=1a�X eJa. TYPICAL SECTION SCALE %" 0�wsr- --,.fo4::6.' .AL -��T-�-%�✓z�fi�-.ram, Product Review Affidavit Product _ Opening Design Product Rated Manufacturer Model Number Product Approval Glass vrr _ press es Deli n Proseuco _. Number Tin SW/N t3_4G .•tSS viatc 60$7.3 DdOJPS' - `�8.6 i 2zw , 1 - _ WINDOW INFILL DETAIL SCALE ''/<" REAR ELEVATION _ _ - SCALE''/a" I`:d�Yt tL_G tt.&rt%' FLOOR PLAN SCALE %" Method of Attachment iN %rrRE3�r r�> r .r �� •v Cz - 101-w z ., s vo 'C 2..r GENERAL NOTES: 1. THE OWNER WOULD LIKE TO REPAIR WATER DAMAGED 2 x 4 FRAMED EXTERIOR WALL. 2. WATER DAMAGED FRAMING TO BE REPLACED, 3. NEW STRAPPING TO BE INSTALLED AS INDICATED. 4. REMOVE EXISTING WINDOW & INFILL OPENING, 5. REMOVE EXISTING SLIDING GLASS DOOR AND INSTALL 6068 (GLAZED) FRENCH DOORS IN THE OPENING. 6. THE ROOM WAS PERMITTED AS AN ENCLOSED PORCH. 7. EXTERIOR & INTERIOR SIDING TO BE T-111. 8. NO ELECTRICAL, HVAC, OR PLUMBING WORK TO BE DONE, 9. ALL WORK TO BE DONE IN ACCORDANCE WITH THE 2014 FBC (5th EDITION) CONTRACTOR TO VERIFY ALL DIMENSIONS AND STRUCTURAL CONDITIONS AS SHOWN ON THE PLANS. ANY DISCREPENCY BETWEEN THE PLANS AND EXISTING CONDITIONS SHOULD BE REPORTED TO THE ENGINEER. NNCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSISIM OF THE CORTRACTOROF RECORD LJ��fGL.F Y4 - f�Qh C.K 4 LEGEND. EXISTING — — — — NEW File COPY ALL MANUFACTURES LABLES U FACTORS AND SHGC COM WITH FBC ENERGY CODE REMAIN ON ALL DOORS AND % SITE PLAN UNTILINSPECTIONSAREAPI SCALE 1 "=20' 7 HCSE PLANS AND A.L PROPOSED''iiORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT %cAY BE NECESSARY IN ORDER TO ST. LI'CT' t'r3f TV 1T nnr DIVISION CQMPLYWITH tLL tiPPLICABL@' E CODES: RIN ill0 2'R 'rNIPLIAACE ......... - DATE PLANS AND ERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. RECEIVE APR 18 2017 Certification for Desian Load Compliance DE_GGN PARAIMUM,AM ASSUIMPn0NS USED: (complete all that apply) 1. DESIGN CODE: Za/4 FBC C5!FFJ"OJL/J )jsingASCE7-10 2. Structure Designed as (check one): I�Enclosed _Partially Enclosed _Open 3. Risk Category: _I ✓ 11 _Ill _ IV Exposure Category: `B �C _D 4. Design Wind Velocity ��2$ mph v' ASD _LRFD . End Zone Width: ✓0 It . 5. Mean Roof Height Roof Pitch: ..-.4 :12 Parapet: 4IA ft 6. Components & Cladding Design Pressures used: (PSF, based on 10sgft @ WMRH, cleadyfabe):on all plan openings): Zone 1: '37 Zone 2: t . z Zone 3: Zone 4: Zone 5:_ Garage: 7. Design Loads: Floor: PSF Roof/Dead: - 'AO PSF Roof/Uve: .ilci Balcony: ,Jrrr PSF Dock: PSF Deck: = PSF Stairs: v PSF Fence: SF Railings:. — PSF 8. Were Shear Walls Considered For Structure? -ZYes _Not Applicable „ Explain Why Not: 9. Is A Continuous Load Path Provided? _✓Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 25 4 0 PSF Soil Test Reports Submitted? ye DESIGN PROFESSIONAL CERTIFICATION STA3EMFNT I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Design by: RICHARD A. JEMISON P.O. Box 5616 Ft. Pierce, Fl. 34954 (772)215-5623 6, & C� ` •.....F� DD. N\\\SHAFFER ESS( P.E.. #26694 THE SHAFFER GROUP, INC 2440 FEDERAL HIGHWAY (SUITE 110) STUART, FLORIDA 34994 (772) 220-4990 04/13/' REPAIR EXISTING WALL SHEE & INSTALL NEW DOORS SHEILA CRAAN RESIDENCE 5116 MYRTLE DRIVE FT. PIERCE, FLORIDA OF