Loading...
HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online _ _ ;, Page 1 of 2 BCIS Home Log In User Registration Hot Topics E Submit Surcharge Stats & Facts i Publications FBC Staff BCIS Site Map Links Search 1 Florida ="* Product Approval P r USER: Public User E' f. P.a%7dies'�7�D5 ' Product Approval Menu > Application Detail FL # FL7561-R3 Application Type Revision Code Version 2014 Application Status Approved Comments I Archived ❑ Product Manufacturer I Elite Aluminum Corporation Address/Phone/Email 4650 Lyons Technology Parkway Coconut Creek, FL 33073 (954)949-3200 dk@dokimengineering.net Authorized Signature Do Kim dk@dokimengineering.net I Technical Representative Dan Cooke Address/Phone/Email 1801 NW 64th Street Ft. Lauderdale, FL 33309 (954)491-3700 elitealum@aol.com Quality Assurance Representative Address/Phone/Email Category Roofing .Subcategory Products Introduced as a Result of New Technology Compliance Method Evaluation Report from a Florida Registered Architect or Florida Professional Engineer R Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Do Kim, P.E. the Evaluation Report Florida License PE-49497 Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 11/30/2020 Validated By CBUCK Engineering, Inc. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL7561 R3 COI Cert of Independence.odf h4s://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDq I Licensed 5/1/2017 Florida Building Code Online A I Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code 1709.2 Product Approval Method Method 2 Option B Date Submitted 04/30/2015 Date Validated 05/01/2015 Date Pending FBC Approval 05/10/2015 Date Approved 06/23/2015 Summary of Products FL # Model, Number or Name Description 7561.1 Aluminum/Aluminum Composite 3"/4"/6"x0.024"x1lb EPS Composite Panel, i Panels 3"/4"/6"x0.032x1lb EPS Composite Panel, 3"/4"/6"x0.024"x2lb EPS Composite Panel, 3"/4"/6"x0.030"x2lb EPS Composite Panel, Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL7561 R3 II Elite FL7561-R3 2014 FBC Installation Dwg.pdf Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Do Kim, P.E. PE 49497 Design Pressure: +80/-80 Created by Independent Third Party: Yes Other: In HVHZ, not to be used in structures considered Evaluation Reports living areas per FBC Section 1616 unless impact protection FL7561 R3 AE Elite Alum FL7561-R3 2014 FBC is provided. See installation drawing for nominal allowable Evaluation.Ddf design pressures and spans. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement I Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . i Product Approval Accepts: W ® cClieck M Credit Securii.VMFTRlCr I I i h4s://www.floridabuilding. i rg/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsgJkzX72BeuCecN82vc%2bk,... 5/1/2017 --- --- --- --- - - ---- --- - - ----------------- -- - - ----- - - -- ---- --- ------ ELITE PANEL SPAN TABLES: 1. Net allowable loads are permitted to be multiplied by 1.67 to derive ultimate loads (psf). 3' x 0,024 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 16.17 15.76 15A3 14A0 20 13.44 13.44 1222 10.35 30 10.78 10.78 9.41 6.60 40 9.22 9.22 6.60 235 50 8.17 8.17 3.79 60 7.40 6.39 0.98 - 70 6.81 4.51 - BO 6.33 2.64 - - 4' x 0.024 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET MAX. ALLOWABLE SPAN (FT) ALLOWABLE LOAD (PSF)1 1 L/80 I L/120 I L/180 I L/240 6' x 0.024 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET MAX. ALLOWABLE SPAN (FT) ALLOWABLE LOAD (PSF)1 L/80 I L/120 I L/180 L/240 3' x 0.032 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 17.50 17.50 16.91 15.96 20 16.64 15.96 14.06 12.16 30 15.17 14.06 11.21 8.36 40 13.69 12.16 8.36 4.56 50 12.22 10.26 5.51 0.76 60 10.75 8.36 2.66 70 9.27 6.46 60 7.60 4' x 0.032 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/l20 L/180 L/240 10 20.50 1 20.50 20.11 19.24 20 19.61 19.24 17.49 15.74 30 18117 17.49 14.67 40 16.72 15.74 12.24 50 15.28 13,99 9.62 60 13184 12,24 7,00 g175 70 12,40 WAS 4.3880 10.95 8.74 6' x 0.032 x 1 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 24.00 1 24,00 24.00 2342 20 23,34 23.21 21.82 2022 30 22.10 2L63 19.42 20.86 20A5 17,02 50 1942 18.47 14.62 60 18.38 1689 12.22 g7O2240 70 17,14 1530 9.82 80 1591 1372 7.42 3' x 0,024 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)l MAX. ALLOWABLE SPAN (FT) L/80 I L/120 I L/180 L/240 10 19.33 18.95 18.31 17.66 20 18.11 17.66 16.36 15a6 30 16.80 16.36 14.41 12.46 15,49 IS06 12.46 9.86 14.18 13.76 10,51 7.26 JOEF.1.17 12.87 12.46 8.57 4.67 11.16 662 2.07 80 ID.26 9.86 4.67 4' x 0.024 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 21.97 21.97 21.52 20.97 20 20.77 20.77 19.86 18.76 30 19157 1957 1821 16.55 40 18.36 18.36 16.55 14.34 50 17.16 17.16 14.89 12J3 60 15.96 15.96 13.24 9.93 70 14.75 14.75 I1.58 7.72 80 13.55 1355 9.93 5.51 6' x 0,024 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX, ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 l0 23.93 23.93 23.88 23.60 20 23.20 23.20 23,03 22.46 30 22.47 22.47 22.18 21.33 40 2L75 21175 21.33 2020 50 21102 21.02 20.49 19,17 60 20.29 20.29 19.64 17.9q 70 19.57 19.57 18.79 16,B1 80 18.84 18.94 17.94 15.68 GENERAL NOTES 1. Composite panels shall be constructed using type 3003-14154 aluminum facings, I or 2 PCF ASTM C-578 carpenter brand EPS adhere to aluminum facings with Ashland Chemical 2020D ISO grip. Fabrication to be by Elite panel products only in accordance with approved fabrication methods. 2. Elite roof panels maintain a UL 1715 (inl) class 'B' (ext) rating and arc NER-501 approved. 3. This specification has been designed and shall be fabricated in accordance with the requirements of the Florida Building Code 511 Edition (FBC), composite panels comply with Chapter 7 Section 720, Chapter 8 Section 803, Class A interior finish, and Chapter 26 Section 2603, All local building code amendments shall be adhered to as required. 4. The designer shall determine by accepted engineering practice the allowable loads for site specific load conditions (including load combinations) using the data from the allowable loads tables and spans in this approval. 5. Deflection limits and allowable spans have been listed to meet FBC including the HVHZ. In HVHZ, this product shall be used in structures "not to be considered living areas" per Section 1616 unless impact resistance in accordance to the HVHZ requirements are met. 6. Safety factor of 2.0 has been use to develop allowable loads and spans from testing in accordance to the Guidelines for Aluminum Structures Part I and conforms to the FBC Chapter 16 and 20. 7. Testing has been conducted in accordance to ASTM E72-05: Strength Test of Panels for Building Construction, S. Reference test reports: HETI-05-1988, HETI-06-2104, HETI.06-2066, HETI-06-2105, HETI-06-2067, HETI-05-1002, HETI- 06-2107, HETI-05-1987, HETI-06-2069, HETI-06-2070, FIETI-06-2071, FIETI-05-1994, ITETI-05-1991, HETI-06.2072, HETI-06-2073, HETI-06-2074, HETI-05-1996, HETI-05-1989, HETI-05-1993, FIETI-05-1985, HETI-05-1995, HETI-05- 1990, HETI-05-1997, HETI-05-2037, HETI-05-2029, HETI-05-2039, HETI-05-2030, HETI-05-2041, FIETI-05-2048, HETI- 05-2036, HETI-05-2031, HETI-05-2038, FIETI-05-2065, HETI-05-2040, FIETI-05-2042. 9. Linear interpolation shall be allowed for figures within the tables shown. 10. Panels with fan beams shall be considered equivalent to similar panels without fan beams. Design professionals may include 611 3' x 0.030 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/160 L/240 10 20J1 20.03 19.42 Fe-e 20 19.02 18.81 17.58 16.35 30 17.93 17.58 15.73 13.89 40 1&83 1&35 13.89 11.43 50 15.74 15.12 12.05 8.97 60 14.64 13.89 10421 6.52 70 13.55 12.66 8.36 4.06 80 12.46 11.43 6.52 1.60 4' x 0.030 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 I L/240 10 24.17 24.17 24.17 24.17 20 23.64 2364 23.41 23,11 30 22.57 22.57 21.90 21.01 40 21.51 21.51 2039 18.91 50 20.45 20.45 18.88 1620 60 19.39 19.39 17.37 14.70 70 18.33 18.33 15.86 12.59 80 17.26 17.26 14.35 10.49 6' x 0,030 x 2 - LB EPS PANELS (ALLOWABLE CLEAR SPAN CHARTS) NET ALLOWABLE LOAD (PSF)I MAX. ALLOWABLE SPAN (FT) L/80 L/120 L/180 L/240 10 24.00 1 24.00 24.00 23.84 2D 23,65 23,65 23.34 22.84 30 22.94 22,94 22459 2LB5 40 22.23 22.23 21.85 20.85 50 2tS3 21.53 ELIO 19.86 60 20.82 20.82 2036 18.87 70 20.11 20.11 19.61 17.87 80 19.40 19AD 18.87 16.88 SEAL JOINT WITH CONTINUOUS CAULKING (-T 0000 000000 za ) 0 C10C1000000� nC> BOTTOM FACINGS INTERLOCKING CROSS SECTION OPTIONAL GUTTER I DRIP CA; SLOPE 4' MAX WIDTH INTERLOCKING F PANEL (1/4'/FT MIN SLOPE) 0 00 00 00 W � °OO°Oo°oz a EPS CORE 1LH OR 213 O°O°O°o o°o°o°o°o°o° aA 0°0°0°0 0 0 i ALUMINUM BOTTOM u 00 FACINGS 000 0 Imo --CLEAR SPAN (L) INSIDE TO INSIDE 00 OH.. •oO o ENGINEER OF RECORD TO PROVI➢E °O 36• MAX IN FRONT 4 25%4 FOR ROOF CONNECTIONS 4 ADD THICKNESS OF 00 OF PANEL VIDTH 8 SIDES SUPPORTING STRUCTURE DETAIL BY WALL FOR TOTAL ° ° THIS OR ANY OTHER ENGINEER. PANEL SPAN, 00 (12' MAX AT SI➢ES) EPS ROOF PANEL/ SPAN DESCRIPTION DO KIM & ASSOCIATES, LL CONSULTING STRUCTURAL ENGINEERS PO BOX 10039 Tempe, FL 33879 Tel: (813)857.9955 NI ISSUED FOR PRODUCT 2M APPROVAL 6Q0 ISSUED FOR 2007 2006 PRODUCT APPROVAL 212o I59U"FOR" FBC 8 2002 PRODUCTAPPROVAL E OR C6N Qj p16 "PRODUCT 5ROVAL m C 3 ro 0tir�i OlJ1 U oY rc � U 0) �� U N 0 C WW CD No. STATETOPP0, FL J (n i W O O.' ¢ZCL uj ujtoU Z 13 pia UQW UU O C) O o Z F 0 LL Q 0 IL W 0 J I.I. Drawing No. - FLA 001 SHEET 10F1