Loading...
HomeMy WebLinkAboutBuilding plansCONTRACTOR: Master Craft Aluminum' DESIGN CRITERIA: Applicable Codes, Regulations, and Standards 1. The 5th Edition (2014) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ARM 35 and Specifications for Aluminum Structures, Pad I -A ofthe Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition and the Guide to Aluminum Construction in high wind mess, 2010. 3. ASCE 7-10. Wind Loads 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 2. 2. Basic Wind Speed, Table 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: Vvrr=160 MP$W =124 MPH 3. Exposure Category, Paragraph 1609.4.3: Exposure B 4. Building Category for Aluminum Structures, Paragraph 2002A Category TYPE 2 - GLASS ROOM: Non -Habitable, Unconditioned Roof Type 1. Roof Type: EXISTING 2. Roof Material: EXISTING Foundation Desigo Existing concrete slab. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spalling, or other deterioration. The following specifications are applicable to this project 1. All work shall be in accordance with the 5th Edition (2014) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Seacoast Aluminum Engineering, LLC. 3. Screen Material: Design based on I8/14 or 20/20 Better View. Any other material most be approved. 4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stairess steel series "400". 5. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or #12 screws 6" from ends and 12" center to center. 6. Door location shall be determined by contractor in the field. 7. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or mom regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cemem Type 1,- ASTM C 150 it. Aggregates - Large Aggregate 3/4" max - ASTM C 33 in. Air entraining +/- 1 % - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after hatching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for reaches in compliance with the FBC - g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 8. All lumber and plywood shall have grade marks and treatment identification and Shall conform to the following: a. Framing lumber shall be minimum no. 2 southern yellow pine and have a maximum moisture content of 15%. b. Pressure treatments shall be osmosalts, carouse k-33, womansalts or celeste, as recommended for the use condition. Pressure treated lumber shall be impregnated with a cca salt treatment in accordance with f.s. tt-w-571 and bear the American Wood Preservatives Institute quality mark Ip-2. c. Wall Sheathing: APA rated Sheathing, thickness as indicated, Exposure 1. d. Aluminum members that are uncoated shall be separated from PT lumber by 30# felt paper, 10 an polyethylene sheet or equivalent material. 9. Contractor shall provide Florida Product Approval information as to the exact window being utilized for this project, including manufacturers specifications, and installation methods for anchoring the submitted windows to Aluminum members and specific sizes as indicated on A-1. 10. Contractor shall provide any additional backing and anchors as required by the window manufacturers recommended procedures. 11. All glass panels within 24" of a door opening shall be of tempered glass per FBC-R308.4 12. All flashing and weatherproofing shall be provided by the contractor. 13. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEEI 4ND EXPOSURE HAVE BEEN DETI TINED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. ALL ELECTRICAL TO BE INSTALLED PER 5TH EDITION (2014) FLORIDA BUILDING CODE 11 L EXISTIRO R90 FASTENERS OR ATTACHMENT'S 00 � ARE THE RESPONS191LIiY0FTHE OONIAACTOROFRECORD FI I lW 8'-10" 8'-11" * 3'-0" -,kL- 5'-3" -+- Tii yE PLMS AND ALL PfROPOS -D V" j9K ARE SO JECT TO ANY COMEC T ION PEQUIRED BY FIELD INSPECTORS THAT L,1AY BE NECESSARY IN ORMN TO CJMIPLYWITH ALI APPI CA&ECG'r' E& Lit J. p G r ul�• J, 7 N IN W 0 Q W O cc a U"s J � Z Oe g WLLJ � R Z V o3^.0 Z"� W a �u W K O Z J ww U U W W 0au> XUHrnv 0 3LL-1 p IL J u)LLLL TP _ 0 DATE DRAWI 03/30/17 t3T, v Its OOUNTV BUILDING DIVISION REVIEWED REVISION 1 Z ' FOR COMPLIAN Q REVIEWED AY DACC SHEET NO: MANSMN ER MUST ErOEOR NO INSPECTION WILL BE MADE A. ALUNUNUM MEMBERS DIMENSI S HOLLOW SECTIONS ��`\ 4'j ,• '�%% / 2x2: 2"x2"x0.046' \ 2 x3: 2"x3"x0.050" 2 x4: 2"x4"x0.050" 17c: W I, �- 2• �' 2 x 5: 2" x 5" x 0.050" 0_ W 0 �• OPEN BACK SECTIONS • I N'.• ) Z _ N1 N �0, O l 1 x 2: 1" x 2" x 0.040" -- Ix3: 1"x3"x 0.045" 1 /� �� SNAP SECTIONS I I I CHAIR RAIL MEMBER I I / ..... ••'•4'C7 2 x2 Snap: 2"x2"x 0.045" i I I '�., pR� 2 x3 Snap: 2"x371x 0.050" 4" 0.045" 3"x3"x 0.070'II�� POST I I t` 2 x 4 Snap: 2" x x I PROFE SIDNAL StEAL SELF MATING (SMB) 2 x4 SMB: 2"x4"x0.044"x0.100" I I 2" x 2" x 1/e" ANG I LED/ ' C 2 x 5 SMB: 2" x 5" x 0.050" X 0.100" 1 1 (4)#10x5/B"EACH SIDE 2 x6 SMB: 2"x6"x 0.050"x0. 120" I 2' x 2" x 3" x 1/8" ALUM ANGLE I UPRIGHT 0 2 x7 SMB: 2"x T'x 0.057" x 0. 120" T'z 3" RC W/1/4"CONCRETE I EACH SIDE OF UPRIGHT W 2 x8 SMB: 2"x8"x0.072"x0. 124" SCREWANCHOR6"FROM I W/3/8"DIA. x3"CONCRETE I U LJ a 9BJIMUMFASTENER N EACH SIDE UP(M OR3/40" NH2314' EMBED.) j (q)#7 SMS SCREWS I O Q z M EDGE DISTANCE: 1/2" MINIMUM FASTENER SPACING: 384" < 0. ...<". u .... >. W i N i CONCRETE SCREW ANCHOR: a. ° < Z w w Q w 0 SIMPSON TITEN HD OR EQUIVALENT -- a' ` - > W SHEET METAL SCREWS (SMS): � z _ U! FrW / BUILDEX OR EQUIVALENT ° a H 2 B 3" x 3" POST TO DECK CONNECTION DETAILS C+ CHAIR RAIL TO UPRIGHT DETAIL z A-2 SCALE: NTS A -2 f1 SCALE: NTS J J J s r Z z$om Q W wJg LU Q W h h V U y~ Q N N 7 Z Gg� 9 VI W Mii CONC. HEADER' 1/4" x 4" CONCRETE WOOD HEADER: SCREW ANCHOR @ 24" O.C. (1) 3/8" x 3" LAG SCREW INTO HEADER WOOD HEADER' WOOD SCREWS' EXISTING HEADER CONCRETE HEADER: (1)3/8"DIA. z3"CONCRETE SCREW WOOD: #10 x 3" WOOD SCREWS, 6" .0. ANCHOR INTO HEADER FROM GIRT &®12"O.C. _ — 7 CONIC: 114"x 2 3/4" CONCRETE SCREW ANCHORS, 6" '0121 H FROM GIRT&@24"O.O EXISTINGW2"x2"Oft i 2"X3"HOLLOW > I HEADER ISECTION GIRT —Z— —ON _ — — ..._ _._ — —W _ _ — _... __ .— _ y`,#10x4"WOOD W2"x2"zi/8"3' ` 2"x3"HOLLOW ' ; 2"x3W/#10x3"SM5-e" vLU W Z�aM,4XEACHSIDE LONGANGLE SECTION OF POST —� OFW/(3)#14x3/4"EACH C: S AND 24"O.C. MAX o3LL R' M FLANGE C:NLL1/4'• DIA x 4"COTE 2"xP' x 0.125" ALUM ANGLE W/ SCREWANCHOR@.C. (4)#14 x 3/4" SMS INTO UPRIGHT DRAWN BY x 3" 2" x 3" W 2" x UPRIGHT TP SECTION DATE DRAWN Ex1srlNc Hosr 03/30/17 REVISION - B-1 iX2 TO HEADER DETAIL A- C-- 2X3 TO HOST STRUCTURE DETAIL A_2 SCALE: NTS B-2 POST TO HEADER DETAIL _ A-2 SCALE: NTS A-2 SCALE: NTS SHEET NO: A-2 E EXISTING CONCRETE 2"x 3'71"x3"RC FASTEN PLYWOOD SHEATHING W1#12x VSMS@6"O.C. AT PERIMETER AND INTERIOR SUPPORTS x 3" P.B. @ 16" O.C. 1/2" COX OVERTY-VEX AND 7/6" STUCCO FINISH OVER PAPER BACKED WIRE LATH WITH LATH SCREWS 3" RC Wl (3) #14 x 3/4" SMS H SIDE Gp2 2" x 3" OR LARGER UPRIGHT TO DECK DETAILS A-J SCALE: NT$ ANGLE 5032 H.2 2116 MH C-NC SLAB I FOO ING 0 ? ?ANCHOR EM.BEOMENT SEE PLAN .4 d a' A . x, SIDE VIEW (1) 3/8" DIA. CONCRETE SCREWANCHORS (2114" CONC. EMBED) a - o I O o'• J =a c) O 'lllIIIIII\� PROFESSIONAL SEAL (3) #12 x 3!4"SMS INTO DJ V x 3" RECENING JAMB 4 1"x WRECEIVING CHANNEL ANCHORED TO CONIC W11/4" CONCRETE SCREW ANCHOR k (MIN. 11/4"EMBED) 6" MAX EACH SIDE OF POST q• AND 24" O.C. MAX FRONT VIEW DJ-1 UPRIGHT TO CONCRETE a PRE -HUNG A-3 DOOR LOCATION DETAIL SCALE: NITS ❑ ® 8 0 K O LLi - Li o: w cC r I.L. 0 zi w < i Of Lu of �> > Z zW ¢w w i i Z w _� w u~iu H-d I I Z_ 1 c (J� ' L J = ! t7 � FZz$QQm I s N � �mST .. Qwuj mi u Z V <�« Z (Dc¢CD p =) Z 9 N W ".luk'�. N H- Lu lJLl d' O z LLI Q J 0 U LU VzwW -0 0Oarn OMOLL TP DATE DRAWN 03/30/17 SHEET NO: A-3