HomeMy WebLinkAboutProject Information Vol - O(Z Cks FLO A V1 d3, d 6 a 5 ENGINEERING & TESTING., INC. Phone: (866)781-6889*Fax: (866) 784-8550 www.flolidaenginceringandtesting.com 250 S.W.13"'Avenue Pompano Beach,FL 33069 April 27,2017 RECEIVED .',;` Q ?.0�7 Job Order No.: 17-1434 Permit No.: Florida Foundation Systems 2030 N.W. 22nd Court Pompano Beach,Florida 33069 RE: PILING INSPECTION Underpinning Existing Foundation 4715 Myrtle Drive Fort Pierce,Florida Dear Sir or Madam: Pursuant to your request, Florida Engineering & Testing, Inc., has performed a site inspection on April 17, 18 and 20, 2017, at the above referenced project. The purpose of our inspection was to monitor pile installation operations. Twelve (12) helical piles, consisting of 2-7/8 inch shaft diameter with two (2) helices of 10 and 12 inches were drilled to the indicated resistance to achieve a minimum allowable capacity in compression of five (5)tons per pile and an ultimate capacity in compression of ten(10)tons per pile. Two (2) helical piles, consisting of 2-7/8 inch shaft diameter with two (2) helices of 10 and 12 inches were drilled to the indicated resistance to achieve a minimum allowable capacity in compression of two (2) tons per pile and an ultimate capacity in compression of four (4) tons per pile. Please refer to the attached Report of Helical Pier/Pile Installation for details. If you have any questions or comments, please give us a call. We would be glad to help any way we can. It has been a pleasure working with you and we look forward to hearing from you in the near future. ��` 0l I I III///® N` pLAN ,.ec-iy. ��, Sincerely, 'N sF',, ®* 8202 A = Mark A. Mesianosl . 4 STATE OF Florida Engineerir5'g,-v Florida Reg. No. 482'� 3'jo E�o�e� Certificate of Authorizatfdn, t,69Q"� Attachments: Report of Helical Pier/Pile Installation n ElPY Field Sketch L Quality 'y�LIL4s.,,mce r ' a 0 FLQ I A ENGINEERING & TESTING, INC. Phone: (866)781-6889•Fax: (866)784-8550 w-*,nv.floridaenginceringandtesting.com 250 S:W.13' Avenue Pompano Beach,FL 33069 REPORT OF HELICAL PIERIPILE INSTALLATION CLIENT: Florida Foundation Systems DATE: 4/17/17 PROJECT: Underpinning Existing Foundation ORDER NO: 17-1434 ADDRESS: 4715 Myrtle Drive Fort Pierce,Florida DIAMETER: 2-7/8" Shaft Diameter& Helices (2) of loll and 12" GEAR MOTOR SERIAL: 104-1561-006 Helical Elevation Allowable Ultimate Relative to Differential Indicated Pile# Pier/Pile Existing Pressure Torque Capacity in Capacity in Depth Driven Ground (psi) (ft-lbs) Compression Compression (ft) Level(ft) (Tons) (Tons) 7 21 0 1150 2222.2+ 5 10 6 20 0 1150 2222.2+ 5 10 8 23 0 1200 2222.2+ 5 10 Remarks: Field Rep.: J.R. Respectfully Subn ,NL A! �i r-a-i * �o.48202 o Mark A. Mesiiftl k.E. Florida Engin ,& { ,In���` Florida Reg. No!� CORIDP.-'������ je' Certificate of Ant p Qualiftj QA SL4=trance ! 11 PILOA ENGINEERING & TESTING, INC. Phone: (866)781-6889•Fax: (866)784-8550 vv ww.floridaengineeringandtesting.com 250 S.W.EP'Avenue Pompano Beach,FL 33069 REPORT OF HELICAL PIERMILE INSTALLATION CLIENT: Florida Foundation Systems DATE: 4/18/17 PROJECT: Underpinning Existing Foundation ORDER NO: 17-1434 ADDRESS: 4715 Myrtle Drive Fort Pierce,Florida DIAMETER: 2-7/8" Shaft Diameter& Helices (2) of 10" and 12" GEAR MOTOR SERIAL: 104-1561-006 Elevation Helical Allowable Ultimate Relative to Differential Indicated Pier/Pile Capacity in Capacity in Pile# Existing Pressure Torque Depth Driven Compression Compression Ground (psi) (ft-lbs) (ft) (Tons) (Tons) Level ft 4 32 0 1120 2222.2 5 10 3 30 0 1120 2222.2 5 10 2 20 0 1150 2222.2+ 5 10 1 20 0 1300 2222.2+ 5 10 9 24 0 1350 2222.2+ 5 10 10 25 0 1250 2222.2+ 5 10 IF- Remarks: Respectfully Sub � �i 0 iField Rep.: M.W. 1��;p{�-q'�� �/s/� Mark A. Me&boj P.E. ' �k Florida En Zed Florida Reg. � ZjW2 APf �, Certificate of A� , ia6�Ce f`Q V �l�� 0NAL���e���a Qrcaliiiy ��,,Ali,,✓lssrcrance FUO A ENGINEERING & TESTING, INC. Phone: (866)781-6889•Fax: (866)78 4-8550 wiviT.floridaengineeringandtesting.com 250 S.W.1:0 Avenue Pompano Beach,FL 33069 REPORT OF HELICAL PIERMILE INSTALLATION CLIENT: Florida Foundation Systems DATE: 4/20/17 PROJECT: Underpinning Existing Foundation ORDER NO: 17-1434 ADDRESS: 4715 Myrtle Drive Fort Pierce,Florida DIAMETER: 2-7/8" Shaft Diameter& Helices (2) of 10" and 12" GEAR MOTOR SERIAL: 37309-28424 Elevation Helical Allowable Ultimate Relative to Differential Indicated Pile# Pier/Pile Existing Pressure To Capacity in Capacity in Torque Depth Driven Ground (psi) (ftrqu Compression Compression (ft) (Tons) (Tons) Level ft 13 16 0 1500 800+ 2 4 14 16 0 1500 800+ 2 4 Remarks: Field Rep.: M.W. Respectfully SubmitA N I4f ��%N --eye-FdS�VX -2-ASk No.482 ® r Mark A.Mesia& �E. Florida Engine6F' �& W1nc�'4 Florida Reg.No •'OCO P. N Certificate of Aut9q, Qrcalitr/ 4 QA �.lss:crarece �/®'i 1,fll A 1 i \X� \� ee .f • A A ib ' 1 2 COVERED PATIO i `� 3 �13 �14 11 12 Poly Void fill and stab raise o 4 s s° s . . 5 6 7 8 9 Field Sketch Not to Scale 4715 )fyrtle Drive Fort Pierce, Florida