Loading...
HomeMy WebLinkAboutProject Information (2) FI00 A ENGINEERING & TESTING., INC. 11 Phone: (866)781-6889 •Fax: (866) 784-8550 www.floridaenginecringandtesting.com 250 S.W.13t.'A<<enue Pompano Beach,FL 33069 RECEIb'�D '. " . � 17 April 27,2017 Job Order No.: 17-1434 Permit No.: Florida Foundation Systems 2030 N.W.22°d Court Pompano Beach,Florida 33069 t RE: PILING INSPECTION Underpinning Existing Foundation 4715 Myrtle Drive Fort Pierce,Florida Dear Sir or Madam: Pursuant to your request, Florida Engineering & Testing, Inc., has performed a site inspection on April 17, 18 and 20, 2017, at the above referenced project. The purpose of our inspection was to monitor pile installation operations. Twelve (12) helical piles, consisting of 2-7/8 inch shaft diameter with two (2) helices of 10 and 12 inches were drilled to the indicated resistance to achieve a minimum allowable capacity in compression of five (5) tons per pile and an ultimate capacity in compression of ten(10)tons per pile. Two (2) helical piles, consisting of 2-7/8 inch shaft diameter with two (2) helices of 10 and 12 inches were drilled to the indicated resistance to achieve a minimum allowable capacity in compression of two (2) tons per pile and an ultimate capacity in compression of four (4)tons per pile. Please refer to the attached Report of Helical Pier/Pile Installation for details. If you have any questions or comments, please give us a call. We would be glad to help any way we can. It has been a pleasure working with you and we look forward to hearing from you in the near future. Sincerely, i NLAIV y ®®NNN�I S F . 7 f No.482p2 Mark A. Mesiano,P.G-u ' � o Florida Engineering 6Ee&ingSMTe OF Florida Reg.No. 48202�,, Certificate of Authorizatr °6 �P''��� ji��eA L Attachments: Report of Helical Pier/Pile Installation Field Sketch Quality`4+ N .$ssurance w 3� FLO A ENGINEERING & TESTING, INC. Phone: (866)781-6889*Fax: (866)78 4-8550 Tnvw.floridaengineei-ingandtesting.com 250 S.W.13"'Avenue Pompano Beach,FL 33069 REPORT OF HELICAL PIER/PILE INSTALLATION CLIENT: Florida Foundation Systems DATE: 4/17/17 PROJECT: Underpinning Existing Foundation ORDER NO: 17-1434 ADDRESS: 4715 Myrtle Drive Fort Pierce,Florida DIAMETER: 2-7/8" Shaft Diameter&Helices (2) of 10" and 12" GEAR MOTOR SERIAL: 104-1561-006 Helical Elevation Allowable Ultimate Relative to Differential Indicated Pile# Pier/Pile Existing Pressure Torque Capacity in Capacity in Depth Driven Ground (psi) (ft-lbs) Compression Compression (ft) Level(ft) (Tons) (Tons) 7 21 0 1150 2222.2+ 5 10 6 20 0 1150 2222.2+ 5 10 8 23 0 1200 2222.2+ 5 10 Remarks: Field Rep.: J.R. Respectfully SubmNlfi�e/%/ *N-N \L' E IV N�28' 2® T a {" � Mark A. MesiAo P.E. * = Florida Engin �& T i&Inc:Z Florida Reg. NaG�4S,JQ2 %4� �- t N-A Certificate of Au Qicalify izi,�`��i4y.assurance c FLO A ENGINEERING & TESTING, INC. Phone:(866)781-6889*Fax: (866)784-8550 www.floridaengineei-ingandttsting.COM 250 S.W.13`h Avenue Pompano Beach,FL 33069 REPORT OF HELICAL PIER/PILE INSTALLATION CLIENT: Florida Foundation Systems DATE: 4/18/17 PROJECT: Underpinning Existing Foundation ORDER NO: 17-1434 ADDRESS: 4715 Myrtle Drive Fort Pierce,Florida DIAMETER: 2-7/8" Shaft Diameter&Helices (2) of 10" and 12" GEAR MOTOR SERIAL: 104-1561-006 Elevation Helical Allowable Ultimate Relative to Differential Indicated Pile# Pier/Pile Existing Pressure Torque Capacity in Capacity in Depth Driven Ground (psi) (ftqu Compression Compression (ft) Level(ft) (Tons) (Tons) 4 32 0 1120 2222.2 5 10 3 30 0 1120 2222.2 5 10 2 20 0 1150 2222.2+ 5 10 1 20 0 1300 2222.2+ 5 10 9 24 0 1350 2222.2+ 5 10 10 25 0 1250 2222.2+ 5 10 Remarks: Respectfully S ed d Field Rep.: M.W. fio.48202 �e 5 Z y 7 STATE OF ; w Mark A. Mesiai?a. � P.'R COl� • � � Florida Engineerifr ��'�` ,�� ®�� Florida Reg. No. 8 62?1' Certificate of Authorization No. 6923 Qualffij ,ASV w1ssnrance PILO A ENGINEERING & TESTING, INC. Phone: (866)781-6889•Fax: (866)78=4-8550 wivw.floridaengineeringandtesting.com 2.50 S.W.13""Avenue Pompano Beach,FL 33069 REPORT OF HELICAL PIERMILE INSTALLATION CLIENT: Florida Foundation Systems DATE: 4/20/17 PROJECT: Underpinning Existing Foundation ORDER NO: 17-1434 ADDRESS: 4715 Myrtle Drive Fort Pierce,Florida DIAMETER: 2-7/8" Shaft Diameter&Helices (2) of loll and 12" GEAR MOTOR SERIAL: 37309-28424 Helical Elevation Allowable Ultimate Relative to Differential Indicated Pile# Pier/Pile Existing Pressure Torque Capacity in Capacity in Depth Driven Ground (psi) (ft-lbs) Compression Compression (ft) Level(ft) (Tons) (Tons) 13 16 0 1500 800+ 2 4 14 16 0 1500 800+ 2 4 Remarks: NLA P ' Respectfully Sub ` � s Field Rep.: M.W. m� Ns�,psi .g82 � 1Vo 02 O .S'l/ � � - Mark A.Mesiano� Sg7gr Op 11 ii� 'Florida Engineer Tsting,Inc;4 Florida Reg. No. 482( +�' ORIDF�.�' N Certificate of Authorizh i► i' ' QrcaZiZrJ�'IV, j � 1�.las:crance f1 A A ' 1 I 2 COVERED PATIO in 3 �13 �14 1 12 Y° Poly Void fill and stab raisa 0 4 _ s s° s. s. 5 6 7 8 9 Field Sketch Not to Scale 4715 Myrtle Drive Fort Pierce, Florida