HomeMy WebLinkAboutProject Information i PSI APPROVAL 2015-06-0216 File, COPY t?esi in Calculations far Sia&Nde Model A DCA#SSl:2220 Shed far,Suge�rioter Abak.Inc. Project Single Wide Model A DCA#SSI--2220 �x Information �" To Build On r,h..eti.oe.as.•w.u. Prepart Frank A.Cleaton r Jr. CODE REVIEW Professional Service Industries Davis&Cleaton g En ineerin ,Inc. 1748 33rd Street g Orlando,Florida 32839 260 Wekiva Springs Road,Suite 1060 Plan d Reviewer.r.William I—Neary,III Longwood,FL 32779 LA#000aas PE#35816 FL SMl-79,SMP-51 Date: May 6,2015 Structural Notes: Description: This is a skid mounted shed constructed of wood with metal Simpson connectors. The sheds are constructed to pre-determined dimensions. The pre-determined dimensions are as follows: Width Width Length Wall Height (Ft.) (Ft.) (Ft.) (Ft.) 6 6-0" 40'-0"(Max.) 5'-0"to T-0" 8 8'-0" 40'-0"(Max.) V-0"to T-0" 10 10'-0" 40'-0"(Max.) 5'4"to 7'-0" 11.667 11'-8" 40'-0"(Max.) 5'-0"to T-0" 13.667 13'-8" 40'-0"(Max.) 5'-0"to 7'-0" Scope: Provide structural calculations for an 13'-8"x40'-0"x7-0"high wall shed to be able to withstand erection,dead,live,wind and snow loading conditions. Design Criteria: Design Code: 2014 FBC-Residential,Section R101.2&Building,Chapter 16 (Note: Design loads were obtained in accordance with ASCE 7-10(American Society of Civil Engineers Minimum Design Loads for Buildings and Other Structures)). Design Parameters: Basic Wind Speed=V„lt— 180 MPH(3-Sec.Wind Speed)., Basic Wind Speed=VeSd= 140 MPH Risk Category: I BuildingCategory: I a = Building Type: Accessory Structure Construction Type: VB Wind Exposure: live � �1"V• iR�. !p A L'r ♦ '��saq'O . 0 Page 1 of 10 , 9 PSI APPROVAL 2015-06-02 DoiQttC&UM- M for Sing,�Q ode Model-A DCA9 M M Shed for-Superiar Sheds. Inc. Applicable Internal Pressure Coefficient: +/- 0.18 Code Requirements: Risk Category: I (Per Table 1604.5) �.. Shed Model: Single Wide Model-DCA#SSI-2220 Summary of Design Pressures on Shed: Walls: Design Pressure= -34.05 PSF Design Pressure= 41.95 PSF Roof: Design Pressure= -56.45 PSF Design Pressure= 14.30 PSF Design Properties of Shed: Roof Pitch= 5 :12 = 22.62 Degrees Dimensions of Shed Being Designed: Length= 40.00 Ft Width= 13.67 Ft. Height= 7.00 Ft. ; Irformabon vi oBuild 0n Awfi-4-C.-MV-*"0 Mean Roof Height= 9.85 Ft. cove REVIEW Professional Service Industries 1748 33rd Street Orlando,Florida 32839 Plan Reviewer.William E.Neary,III Determine Wind Loads on Shed: Icc#5t9W40 LA Iw00409 FL SMI-79,SMP51 Total Wind Load on Walls of Shed= -9,534.00 Lbs. Total Wind Load on Walls of Shed= 11,746.00 Lbs. Total Wind Load on Roof of Shed= -30,859.33 Lbs. Total Vertical Wind Load on Roof of Shed= -118849.98 Lbs. Total Horizontal Wind Load on Roof of Shed= -28,483.16 Lbs. Page 2 of 10 PSI APPROVAL 2015-06-02 • . Design Calculations for Single Wide Mode!-A DCA#SS1-2220 Shed for Su er�ioRr Sheds. lnc. Determine Location of 4"x 4"Runners: Distance Between Floor Joists= 2 Ft Distance Between Interior Floor Runners= 6.92 Ft. X3 6'-11" Distance Between Exterior Floor Runners= 9.92 Ft. X2 9'-11" Distance from Sides to Center of Shed= 6.83 Ft. Distance Between Interior and Exterior Floor Runners= 1.50 Ft Distance Between Exterior Floor Runners and Sides of Shed= 1.875 Ft. X, 1'-101/2" Total Width of Shed= 13.67 Determine Weight of Shed: Construction of Floor System: Floor Joists Spacing= 2 Ft The floor system consists of 2"x 6"#2 S.Y.P.floor joists spaced at 2'-0"on centers. The floor system consists of(4) Longitudinal 4"x 4"#2 S.Y.P. (P.T.)Runners. The floor system consists 3/4"plywood floor sheathing/covering. Construction of Side Wall System: Wall Stud Spacing= 2 Ft. The wall system consists of 2"x 4"#2 S.Y.P. studs spaced at 2'-0"on centers. The wall system consists of 4"x 4"#2 S.Y.P. headers. „�� Infommfion P-r oBuildOn ea.�.•e..du...w.". The wall system consists of 2"x 4"#2 S.Y.P.sills. CODE REVIEW Professional Service lndusWes Street The wall system consists of 1 x 4"#2 S.Y.P. Bridging.(2 Rows) Orflaand Florida 32839 Plan Reviewer.William E.Neary,III ICC B 518M40 The wall system consists 4"aluminum siding. FL SM10-790 SMP-51 Construction of End Wall System: Wall Stud Spacing= 2 Ft. Page 3 of 10 PSI APPROVAL 2015-06-02 ��qn Galcc►latiorts far Sinafe Wide Modef-A DCA#SSf-7770 Shed for Swerf hed fnc The wall system consists of 2"x 4"#2 S.Y.P. studs spaced at 2'-0"on centers. The wall system consists of 4"x 4"#2 S.Y.P. headers. The wall system consists of 2"x 4".#2 S.Y.P.sills. The wall system consists of 1 x 4"#2 S.Y.P. Bridging.(2 Rows) The wall system.consists 4"aluminum siding. Construction of Roof System: Roof Truss Spacing= 2 Ft. Typical Trussed Roof System with Shingles: Determine Overturninq of Shed: Overturning Moment From Wind Load= 124,630.79 Ft.-Lbs. Determine Tension Load on Ground Anchors: Y��.ToBu�Onn Total-Uplift Load on Each Side of Shed= 9,408.35 Lbs. �•-�• ••�• CODE REVIEW Professional Breaking Strength of Ground Anchor= 4,725 Lbs. 174833rd Street Service Orlando,Florida 32839 - Plan Reviewer.William F-Neary,III Safety Factor= 2 Icc a 5185040 a La auoaos FLSMI-79,SMPS7 Tension Capacity of Ground Anchor= 2,362.50 Lbs. Tension Capacity of 1/2"Bolt= 3,743.60 Lbs. Design Tension Capacity of Ground Anchor= 2,362.50 Lbs. Number of Ground Anchors Required on Each Side of Shed= 3.98 Use: 5 Anchors on Each Side of Shed Spacing of Ground Anchors= 10 Ft. Therefore,Use Ground Anchors with 2,000 Lbs.(Min.)Capacity @ 10'-0"on Center on Each Side of Shed. Determine Attachment to Concrete: Total-Uplift Load on Each Side of Shed= 9,408.35 Lbs. Page 4 of 10 • PSI APPROVAL 2015-06-02• Capacity of Wedge Anchor= 870 Lbs. Tension Capacity of 1/2"Bolt= 3,743.60 Lbs. Capacity of Simpson A-24= 870 Lbs. Design Tension Capacity Attachment to Concrete= 870 Lbs. Number of Concrete Anchors Required on Each Side of Shed= 10.81 Use: 11 Anchors on Each Side of Shed Spacing of Ground Anchors= 4 Ft. Therefore,Use Concrete Attachments with 870 Lbs.(Min.)Capacity @ 4'-0"on Center on Each Side of Shed. Determine Design Loads: Design Loads: Floor Loads: Dead Load= 8 PSF Live Load= 75 PSF Roof Loads: Dead Load= 5 PSF Live Load= 20 PSF Wind Loads: Positive= 14.30 PSF Negative= -56.45 PSF CODE REVIEW Professional Service Industries 1748 33rd Street Wall Loads: Orlando,Florida 32839 Plan Reviewer.William E.Neary,III - ICC f15165040 Dead Load= 7 PSF LA ttu0 4 FL SM1-79,SMPS7 Wind Loads: Positive= 41.95 PSF Negative= -34.05 PSF Page 5 of 10 PSI APPROVAL 2015-06-02 • End Wall Loads: Dead Load= 7 PSF Wind Loads: Positive= 41.95 PSF Negative= -34.05 PSF Determine Lifting Load: Total: 6,560.00 Lbs. Summary of Design Loads: Total Lifting Load= 6,560.00 Lbs. Floor Load(DL+LL)= 83 PSF Roof Load (DL+LL)= 25 PSF Roof Load(DL+(+WL))= 19 PSF Roof Load(DL+(-WL))= -51 PSF Wall Load: Lateral= 41.95 PSF (Positive) Lateral= -34.05 PSF (Negative) Check Member Caoacity: ,+ Info ldO n �' lM'�'j oBuildOn CODE REVIEW Floor System: Professional ServiceIndustries 1748 33rd Street Orlando,Florida 32839 Size Floor Joists: 2"x 6"#2 S.Y.P.(P.T.) IC x 5185040 William E.Neary,111 C La uuoo4a9 FL SMI-79,SMP-51 Spacing= 2 Ft. Design Load= 166 Lbs./Ft. Span= 6.92 Ft. Capacity of Floor Joists&Floor Sheathing= 170 Lbs./Ft. Capacity of Floor Joists= . 170 Lbs./Ft. > 166.0 Lbs./Ft. O.K. Page 6 of 10 PSI APPROVAL 2015-06-02 • or Single Wide Mo&(A QO#SS1.M Shedd-qc Sunerfor�$b�ds, lnc Check Deflection: Defl. =5wL4/384EI= 0.257 In. < 0.346 In. O.K. Allow. Defl.=U240= 0.346 In. Determine Attachment of Floor Joists to Runner: Type Connector: Strap Connector: Simpson HS-24 Spacing= At each connection of floor joist to runner Load= 587.23 Lbs. Capacity= 605 Lbs. > 587.23 Lbs. O.K. Therefore,Simpson HS-24 are Acceptable. Wall System: Size Wall Studs: 2"x 4"#2 S.Y.P. Spacing= 2 Ft Infomlotion ToBuiirlOn •ae,rar•warp Applied Loads: CODE REVIEW Professional Service Industries 1748 33rd Street Vertical= 135 Lbs./Ft, Oriando,Florida 32839 Plan Reviewer.William E.Neary,III ICC#5185040 Lateral= -34.05 PSF FLSMII-79,SMP-51 Design Loads: Vertical(Axial)= 270 Lbs. Lateral(Bending)= -68.10 Lbs./Ft. Capacity of Stud Wall: Vertical(Axial)= 3,707.81 Lbs. > 270 Lbs. O.K. Lateral(Bending)= 1,853.91 Lbs./Ft. > -68.10 Lbs./Ft. O.K. Determine Attachment of Will Studs to Floor Joists: Type Connector: Strap Page 7 of 10 ' PSI APPROVAL 2015-06-02 _estm Calculations for Sina&1llI&M.0de1:A DCA#SSl--.2220 Shed far Superior Sheds, tnc. Connector: Simpson LSTA-18 Spacing= At each wall stud. Load= 771.48 Lbs. " Capacity= 1,235 Lbs. > 771.48 Lbs. O.K. Therefore,Simpson LSTA-18 are Acceptable. Roof System: Size Roof Members: 2"x 4"#2 S.Y.P. Spacing= 2 Ft. Number of Roof Trusses= 21 Dead Load+Live Load= 50 Lbs./Ft. Wind Load= -112.90 Lbs./Ft. _} Max. Span= 6.83 Ft. Allow. Bending Stress= 1,500.00 PSI Section Modulus= 3.06 In.3 Allow. Moment= 382.875 Ft.-Lbs. Capacity of Roof Trusses= 65.60 Lbs./Ft. > 50 Lbs./Ft. O.K. Check Deflection: Defl. =5wL4/384EI= 0.286 In. < 0.342 In. O.K. Allow. Defl.=U240= 0.342 In. Determine Reaction @ Each End from Wind Pressure: R= 771.48 Lbs. Plate Type: Mll-20 p f T Romd n ..p.�.,e.,.,..e.. Size Plate: 3"x 5" CODE REVIEW Professional Servicelndustries -' 1748 33rd Street Type of Wood Used for Trusses= #2 S.Y.P. °an RR Aewer Will amBE..Neary,III Icc a 51 BS040 LA auoo4as FL SMI-79,SMP-51 Page 8 of 10, PSI APPROVAL 2015-06-02 s gat=9afc09=for Single Wide ISI:22Y0'Shed ter.Smodd Sheds: lnc. Design Lateral Resistance of Pressed Plates= 184 PSI Design Shear Capacity of Pressed Plate= 2,760.00 Lbs. Design Shear Load= 771.48 Lbs. < 2,760.00 Lbs. O.K. Therefore Trusses @ 2'-0"on center is Acceptable with Collar Ties Attached with 3"x5"(Min.) MII-20 Plates @ Each End. Design Connection Cad Junction of Wall and Roof: �e�����.'�Information All of the connectors for the roof trusses are pressed plates: i�1.7oBufldOn CODE REVIEW Plate Type: MII-20 PmfessionalService Industries 1748 33rd Street Orlando,Florida 32839 Plan Reviewer. Size Plate: 3"X 5" CC#5185040 William E.Neary,III LA tw9o405 FL SMI-79,SMP-51 Area= 15 In.Z Type of Wood Used for Trusses= #2 S.Y.P. Design Lateral Resistance of Pressed Plates= 184 PSI Design Shear Capacity of Pressed Plate= 2,760.00 Lbs. Shear from Wind Load= 385.74 Lbs. Shear from Dead Load= 170.83 Lbs. Design Shear Load= 556.58 Lbs. < 2,760.00 Lbs. O.K. Therefore 3"x 5"MII-20 Pressed Plate is Acceptable. Resign Connection OD Ridge of Roof: Shear from Wind Load= 1356.34 Lbs. Design Shear Load= 1356.34 Lbs. < 2,760.00 Lbs. OX Therefore 3"x 5"MII-20 Pressed Plate is Acceptable. jQesign Connection Ca)_Each End of Truss of Roof: Shear from Wind Load= 678.17 Lbs. Design Shear Load= 678.17 Lbs. < 2,760.00 Lbs. O.K. Page 9 of 10 L PSI APPROVAL 2015-06-02 , r r Q%W= Calculations for sin le Wide Medel-A DCa#SS1-2220 Shed for.Suaerior Sheds. lnc. F Therefore 3"x 5"MII-20 Pressed Plate is Acceptable. Design Attachment for Exterior Wall Siding: �5r: /nfvrnwtion le., - o�y.nev Design Pressure= 41.95 PSF CODE REVIEW g Professional Service industries 1748 33rd Street Orlando Florida 32939 Tributary Width= 2.00 Ft. Plan Reviewer.William E.Neary,III [CC#5185040 LA#000406 FL SMI-79,SMPS1 { Design Load on Wall= 587.30 Lbs. Size Fastener: #9-15 x 1" Screws Ultimate Pull Out= 571 Lbs. Considering 1"thread penetration into 2'V4' Design Capacity of Screw= 142.75 Lbs. Fastener Spacing= 0.69 Screws/Lin. Ft.of Wall Height Therefore#9-15 x 1"Screws Spaced 6"on center(Max.)with 1"(Min.)Thread Penetration Into 2"x4". Desian Attachment for Roof Siding: Design Pressure= 56.45 PSF Tributary Width= 2.00 Ft. Design Load on Wall= 112.90 Lbs./Ft. Size Fastener: #9-15 x 1" Screws Ultimate Pull Out= 571 Lbs. Considering 1"thread penetration into 2"x4" Design Capacity of Screw= 142.75 Lbs. Fastener Spacing= 0.79 Screws/Lin. Ft. of Wall Height Therefore#945 x 1"Screws Spaced 4"on center(Max.)with 1"(Min.)Thread Penetration Into 2"x4". Page 10 of 10