HomeMy WebLinkAboutEnergy Calculation Form & Manual J's FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residenti�, '� ae�thod
p 9 ,� _M�� ,
Project Name: CROUCH Builder Name: OWNER MAY I C £011'
S(.reet: 8280 GERMANY CANAL RD Permit Office: pERfieilTTiPlG
City,State,Zip: PORT ST LUCIE,FL, Permit Number: FL
Owner: CROUCH Jurisdiction: St. Lucie Count}',
Design Location: FL, Fort Pierce County:: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1728.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1728.00 ft2
b.N/A R= ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2597.0 sqft.) Insulation Area a.Under Attic(Vented) R=33.0 2597.00 ft2
6. Conditioned floor area above grade(ft2) 2597 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(291.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 519.4
y a. U-Factor: Dbl, U=0.30 291.33 ft2
SHGC: SHGC=0.29
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 60.0 SEER:15.00
c. U-Factor: N/A ft2
SHGC: 13,Heating systems kBtu/hr Efficiency
d. U-Factor: NIA ft2 a. Electric Heat Pump 60.0 HSPF:8.70
SHGC:
Area Weighted Average Overhang Depth: 0.963 ft.
Area Weighted Average SHGC: 0.290 14.Hot water systems
8. Floor Types (2597.0 sqft.) Insulation Area a. Electric Cap:50 gallons
a.Crawlspace R=11.0 2597.00 ft2 b. Conservation features EF:0.950
b.NIA R= ft2 None
c.NIA R= ft2 15.Credits CF,Pstat
Glass/Floor Area: 0.112
Total Proposed Modified Loads: 77.24 PASS
Total Baseline Loads: 80.11
1�hereby certify that the plans and specifications covered by Review of the plans and 0 Tk1E STg1�
tWs calculation are in compliance with the Florida Energy specifications covered by this ti `_ -
Code. calculation indicates compliance
[with the Florida Energy Code. F, m,,, �.;;•`_ :;;: ;,, O
GANNON BOGGS III
PREPARED BY: .� Before construction is completed
DATE: -- 5-11-17 this building will be inspected for r
ill
compliance with Section 553.908
I N;ereby certify that this building, as designed, is in compliance. Florida Statutes.
with the Florida Energy Co G'O'D WETS
OWNER/AGENT:_-- _�__ BUILDING OFFICIAL:__ _
DATE: -------------�-1 a�� -_ DATE: �--- --------
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 111402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
5/11/2017 9:04 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
- FORM R405-2014
PROJECT
• Title: CROUCH Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2597 Lot#
Owner: CROUCH Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: OWNER Rotate Angle: 270 Street: 8280 GERMANY CANA
Permit Office: Cross Ventilation: County: St.Lucie
Jurisdiction: Whole House Fan: City,State,Zip: PORT ST LUCIE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO_BEACH_MUNI 2 39 �90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Block1 2597 20776
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Infil1D Finished Cooled Heated
1 Main 2597 20776 Yes 5 4 1 Yes Yes Yes
FLOORS
_ # Floor Type _ Space _Exposed PerlWall Ins,R-Value Area Floor Joist R^Value Tile Wood Carpet
1 Crawlspace Main 258 ft 0 2597 ft2 11 0.6 0 0.4
ROOF
J Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Composition shingles 2677 ft2 324 ft2 Medium 0.85 No 0.9 No 0 14
h
ATTIC
y V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented" 150 +2597 ft2 N N ^`
r
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 33 Blown 2597 ft2 0.11 Wood
5/11/2017 9:04 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
- FORM R405-2014
WALLS
' , / Adjacent Cavity Width Height Sheathing Framing Solar Below
V--C--Dmt______To_-_-plall-jpe_- ____ Space_R--yalue`._TEt.-tn_--F.t-In_..._._-A.rea--Et 1lalue-F-ractlon-_Absor._Grade%-
1 N=>W Exterior Frame-Wood Main 11 54 8 432.0 ft2 0 0.600000 0
-2 N=>W Exterior Frame-Wood Main 11 14 8 112.0 ft2 0 0.600000 0
3 E=>N Exterior Frame-Wood Main 11 40 8 320.0 ft2 0 0.600000 0
-4 S=>E Exterior Frame-Wood Main 11 68 8 544.0 ft2 0 0.600000 0
AI 5 W=>S Exterior Frame-Wood Main 11 40 8 320.0 ft2 0 0.600000 0
DOORS
# Omt Door Type Space Storms -U-Value Width Height Area
Ft In Ft_ In _
1 N=>W Wood Main _ ^^ None ^�.35 3 ~6 8 20 ft2
2 E=>N Wood Main None .35 3 6 8 20 ft2
3 S=>E Insulated Main None .35 3 6 8 20 ft
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
{ Wall Overhang
# Omt ID Frame Panes NFRC _ U-Factor SHGC _ Area Depth Separation �Int Shade Screening
1 N=>W 1 Vinyl Low-E Double Yes 0.3 0.29 17.5 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
2 N=>W 1 Vinyl Low-E Double Yes 0.3 0.29 60.0 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
3 N=>W 2 Vinyl Low-E Double Yes 0.3 0.29 15.0 ft2 9 ft 6 in 0 ft 8 in Drapes/blinds None
4 S=>E 4 Vinyl Low-E Double Yes 0.3 0.29 87.5 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
5 S=>E 4 Vinyl Low-E Double Yes 0.3 0.29 40.0 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
6 S=>E 4 Vinyl Low-E Double Yes 0.3 0.29 15.0 ft2 0 ft 6 in 0 ft 8 in. Drapes/blinds None
7 S=>E 4 Vinyl Low-E Double Yes 0.3 0.29 15.0 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
8 W=>S 5 Vinyl Low-E Double Yes 0.3 0.29 30.0 ft2 0 ft 6 in 3 ft 0 in Drapes/blinds None
9 W=>S 5 Vinyl Low-E Double Yes 0.3 0.29 7.5 ft2 0 ft 6 in 3 ft 0 in Drapes/blinds None
10 W=>S 5 Vinyl Low-E Double Yes 0.3 0.29 3.8 ft2 0 ft 6 in 2 ft 0 in Drapes/blinds None
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000254" 1731.3 95.05 +178.75 .1855 5
w HEATING SYSTEM
# System Type Subtype Efficiency r Capacity Block y Ducts
1 Electric Heat Pump None HSPF:8.7 60 kBtu/hr 1 sys#1
L
5/11/2017 9:04 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
COOLING SYSTEM
# System Type Subtype w �_- _ Efficiency Capacity _^ Air Flow SHR Block` Ducts
�I 1 Central Unit None SEER: 15 60 kBtu/hr 1800 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF V Cap Use SetPnt Conservationy�!
1 Electric None Main 0.95 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cart # Company Name �- _ System Model#` _Collector Model# _ Area —_ Volume V FEF
None None ft'
DUCTS
K / ----Supply-- ---Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 519.4 ft Main 129.85 Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar r May Jun r Jul Au r Se Oct Nov Dec
Heatin Jan Pq Feb Mar AprMayjXj
Jun [ Jul f AuE Sep Oct NNov Dec
Ventin Jan Feb Mar r Ma Jun [[[ ]]]Jul [ Aug Se Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD)~ AM 78 78 78 V�78 ^`78 78! �78 ----78` 80^ 80 80 80
PM T
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
v
w
5/11/2017 9:04 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
Building Input Summary Report
PROJECT
Title: CROUCH Bedrooms: 4 Address Type: Street Address
Building Type: User Bathrooms: 0 Lot#
Owner: CROUCH Conditioned Area: 2597 sq.ft. Block/SubDivision:
#of Units: 1 Total Stories: 1 P1atBook:
a Builder Name: OWNER Worst Case:. Yes Street: 8280 GERMANY CANA
Permit Office: Rotate Angle: 270 County: St.Lucie
Jurisdiction: Cross Ventilation: City,State,Zip: PORT ST LUCIE,
Family Type: Single-family Whole House Fan: FL,
New/Existing: New(From Plans) Terrain: Suburban
Year Construct: Shielding: Suburban
Comment:
CLIMATE
Design Design Temp Int Design Temp Heating Design Daily Temp
Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL VERO BEACH MUNICIPAL A 39 90 70 75 299 62 Low
UTILITY RATES
Fuel Unit Utility Name Monthly Fixed Cost $/Unit
Electricity -- kWh EnergyGauge Default — 0 0.1188- —
Natural Gas Therm EnergyGauge Default 0 1.72
Fuel Oil Gallon EnergyGauge Default 0 1.1
Propane Gallon EnergyGauge Default 0 1.4
SURROUNDINGS
Shade Trees Adjacent Buildings
Omt Type Height Width Distance Exist Height Width Distance
N None` — Oft Oft Oft Oft Oft Oft —
NE None Oft Oft Oft Oft Oft Oft
E None Oft Oft Oft 0ft Oft Oft
SE None Oft Oft Oft Oft Oft Oft
S None Oft Oft Oft Oft Oft Oft
SW None Oft Oft Oft Oft Oft Oft-
;� W None Oft Oft Oft Oft Oft Oft
NW None Oft Oft Oft Oft Oft Oft
v
BLOCKS
Number. Name Area Volume
1 Block1 2597 20776
SPACES
Number --- Name - Area Volume Kitchen Occupants Bedrooms — Finished Cooled Heated
1 Main 2597 20776 Yes 5 4 Yes Yes Yes
FLOORS (Total Exposed Area= 2597 sq.ft.)
# Floor Type Space Exposed Pad Wall Ins.R-Value Area Floor Joist R-Value Tile Wood Carpet
1 Crawlspace Main 258 ft 0 2597 ft' 11 0.6 0 0.4
5/11/2017 9:05 AM EnergyGauge@/USRCZB v5.1 Page 1 of 6
Building Input Summary Report
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
III # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Composition shingles 2677 ft2 324 ft2 Medium 0.85 No 0.9 No 0 14
ATTIC
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic` Vented �V 150 2597 ft2 N N
CEILING (Total Exposed Area= 2597 sq.ft.)
# Ceiling Type Space ` R-Value _Ins.Type , Area ,Framing Fraction Truss Type
1 Under Attic() Main 33 Blown 2597 ft2 0.11 Wood
WALLS (Total Exposed Area= 1728 sq.ft.)
Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in"Project"section above.
Adlja eight
cent Space Cavity Width H Sheathing Framing Solar Below
# Omt _To Wall Type_ _ R-Value Ft In Ft In Area R-Value Fraction Absor. Grade%
1 N=>W Exterior Frame-Wood Main 11 54 8 432.0 ft2 0 0.600000 0
2 N=>W Exterior Frame-Wood Main 11 14 8 112.0 ft2 0 0.600000 0
3 E=>N Exterior Frame-Wood Main 11 40 8 320.0 ft2 0 0.600000 0
4 S=>E Exterior Frame-Wood Main 11 68 8 544.0 ft2 0 0.600000 0
5 W=>S Exterior Frame-Wood _ Main 11 40 8 _320.0_ft2 _0 0.600000 0
Total Exposed Gross Wall Area: 1728 sq.ft. Total Window Area: 291 sq.ft. Total Door Area: 60 sq.ft. Net Wall Area: 1377 sq.ft.
DOORS (Total Exposed Area= 60 sq.ft.)
Width Height
# Omt Adjacent to Door Type _ Space Storms U-Value Ft In Ft_ In Area
1 N=>W Exterior Wood Main ~' None .35 !� 3 6 ~8 20 ft2
2 E=>N Exterior Wood Main None .35 3 6 8 20 ft2
3 S=>E Exterior Insulated Main None .35 3 6 8 20 ft2
WINDOWS (Total Exposed Area= 291 sq.ft.)
Wall Overhang
# Omt ID Frame Panes �yNFRC U-Factor SHGC Storm Area Depth Separation Interior Shade Screening
1� N=>W 1 Vinyl Low-E Double Yes 0.3 0.29 N 17.5 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
2 N=>W 1 Vinyl Low-E Double Yes 0.3 0.29 N 60.0 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
.3 N=>W 2 Vinyl Low-E Double Yes 0.3 0.29 N 15.0 ft2 9 ft 6 in 0 ft 81n Drapes/blinds None
4 'S=>E 4 Vinyl Low-E Double Yes 0.3 0.29 N 87.5 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
5 S=>E 4 Vinyl Low-E Double Yes 0.3 0.29 N 40.0 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
6 S=>E 4 Vinyl Low-E Double Yes 0.3 0.29 N 15.0 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
7 S=>E 4 Vinyl Low-E Double Yes 0.3 0.29 N 15.0 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None
8 W=>S 5 Vinyl Low-E Double Yes 0.3 0.29 N 30.0 ft2 0 ft 6 In 3 ft 0 in Drapes/blinds None
9 W=>S 5 Vinyl Low-E Double Yes 0.3 0.29 N 7.5 ft2 0 ft 6 in 3 ft 0 in Drapes/blinds None
10 W=>S 5 Vinyl Low-E Double Yes 0.3 0.29 N 3.8 ft2 0 ft 6 in 2 ft 0 in Drapes/blinds None
5/11/2017 9:05 AM EnergyGauge®/USRCZB v5.1 Page 2 of 6
Building Input Summary Report
INFILTRATION
# Scope Method SLA CFM 50 ELA E LA ACH ACH 50 Space(s)
P q
1 Wholehouse^ Proposed ACH(50) .000254 1731.3 95.05 �178.75 .1855 5 All
MASS
Mass Type Area Thickness Furniture Fraction Space
No Added Mass 0 ft2 0 ft 0.3 Main
HEATING SYSTEM
# System Type Subtype Efficiency Capacity ------Geothermal HeatPump------- Ducts Block
Entry Power Volt. Curr
1 Electric Heat Pump None HSPF:8.7 60 kBtu/hr 0 0 0 s s#1 1
COOLING SYSTEM
# System Type _ _ Subtype Efficiency _ Capacity_ Air Flow SHR Ducts Block
1 Central Unit i None SEER:15 60 kBtu/hr 1800 cfm 0.75 s s#1 1
HOT WATER SYSTEM
# System Type SubType ^„ Location — _ EF _Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length
1 Electric None Main 0.95 50 gal 70 gal 120 deg Standard None 111.92163844992
Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
System Type length length power Connected Flow Eff
No NA NA NA NA No NA NA NA None
SOLAR HOT WATER
Collector Surface Absorp. Trans Tank Tank Tank Heat PV Pump
Collector Type Tilt Azimuth Area Loss Coef. Prod. Corr. Volume U-Value Surf Area Exch Eff Pumped Energy
DUCTS
DUCT --------Supply-------- -------Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 519.4 ft2 Main 6 129.85 ft2 Default Leakage Main Default Default 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans: N
Cooling Jan
Feb Mar Apr may Jun Jul Aug Sep Oct Nov Dec
Heating Jan 3 Feb Mar Apr
May Jun Jul Aug Sep Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
5/11/2017 9:05 AM EnergyGauge®/USRCZB v5.1 Page 3 of 6
Building Input Summary Report
APPLIANCES&LIGHTING
Appliance Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Ceiling Fans(Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33
.,%Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0,9 0.9 0.65
Annual Use: 0 kWhNr Peak Value: 0 Watts
Clothes Washer AM 0.105 0.081 0.046 0.046 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872
_%Released: 60 PM 0.779 0.698 0.605 0.57 0.581 0.57 0.57 0.57 0.57 0.488 0.43 0.198
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Dishwasher AM 0,139 0.06 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443
%Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Dryer AM 0.2 0.1 0.05 0,05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1
%Released: 10 PM 0,875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Lighting AM 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.12 0.11
%Released: 90 PM 0.16 0.17 0.25 027 0.34 0.55 0.55 0.88 1 0.86 0.51 0.28
Annual Use: 2533 kWh/Yr Peak Value: 827 Watts
Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53
%Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1
%Released: 0 PM 1 1 1 1 0 0 0 0 0 0 0 0
Annual Use: 0 kWhfYr Peak Value: 0 Watts
Range AM 0.057 0.057 0.057 0.057 0,057 0.114 0.171 0.286 0.343 0.343 0.343 0.4
%Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
I
Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 0.8 0.8 0.8 0.8
%Released: 100 PM 0,88 0.85 0.85 0.83 0.88 0.95 1 0.98 0,95 0.93 0.9 0.85
Annual Use: 775 kWh/Yr Peak Value: 140 Watts
Well Pump AM 0.05 0.05 0.05 0.05 . 0.05 0.05 0.1 0.1 0.1 0.1 0.1 011
%Released: 0 PM 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0,1
Annual Use: 0 kWh/Yr Peak Value: 0 Watts
REFRIGERATORS
ID Type Screen _ Location - Quantity Vol FrZ.Vol -Make --Model Schedule kWhPerYr
1 Refrigerat Default New Main 1 25.6 5 HERS2011 691
CLOTHES WASHERS
ID Type Screen Location Capacity Make Model Schedule LoadsPerYr
1_1 Cl.washe Default New 1 st Floor 2.874 HERS2011 378
CLOTHES DRYERS
ID - Type _ Screen _ -_ Location Capacity Fuel Type Make --Model - Schedule LoadsPerYr
1 Dryer Default New 1st Floor 2.874 Propane HERS2011 378
5/11/2017 9:05 AM EnergyGauge®/USRCZl3 v5.1 Page 4 of 6
Building Input Summary report
RANGE OVEN
ID^ Type Screen Location Type _ _ Fueltype Make_ , Model Cooktop Oven
1 RangeOv Default New 1st Floor CooktopOven C Propane Electric fl Not Conv
HARD WIRED LIGHTING
ID Type _ Screen ^` Location Total# Qualify# Comp Fl All Other FL txtBulbtype Schedule Watts per bulb
1 Hard-Wir Default Main 20 2 0 2 incandes HERS201 60
2 Hard-Wir Default Exterior 20 2 0 2 Incandes HERS201 60
MISC ELECTRICAL LOADS
ID ^� Type Screen Item—.--- Quantity Catagory Operating _ Location Y_Schedule_ Off Standby
1 Misc Elec Simple Default 1 1 Main HERS2011 1
CEILING FANS
ID ,Type Screen _ Default New cfmperWatt,
1 CeilingFa Default New Standard 70.5
I
5/11/2017 9:05 AM EnergyGauge®/USRCZB v5.1 Page 5 of 6
.IF
Building Input Summary Report
APPLIANCES&LIGHTING SCHEDULES
Appliance Schedule: HERS2014 Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Occupancy peak: 400 Btu AM 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.98 0.46 0.27 0.27 0.27
., %Released: 100% PM 0.27 0.27 0.27 0.27 0.33 0.61 1 1 0.93 0.93 0.93 0.93
refrig peak: 97 W AM 0.824 0.804 0.784 0.764 0.744 0.734 0.744 0.754 0.764 0.794 0.814 0.854
%Released: 100% PM 0,854 0.864 0.884 0.904 0.925 0.945 0,925 0.915 0.904 0.894 0.874 0.854
cWash peak: 0 W AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0,8 0.95 1
%Released: 30% PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375
E-cDry peak: 0 W AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1
%Released: 15% PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375
dWash peak: 0 W AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443
%Released: 60% PM 0.376 0.396 0.334 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281
E-rOven peak: 0 W AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4
%Released: 80% PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114
TVs peak: 252 W AM 0.1 0.05 0.05 0.05 0.1 0.2 0.4 0.45 0.4 0.2 0.1 0.1
%Released: 100% PM 0.05 0.05 0.15 0.45 0.85 1 0.95 0.8 0.5 0.25 0.15 0.1
cFan peak: 213 W AM 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.25 0.25 0.25 0.26 0.25
%Released: 100% PM 0.25 0.25 0.25 0.25 0.25 0.25 0.55 0.6 0.6 0.6 0.6 0.6
Igts-in peak: 818 W AM 0.16 0.15 0.16 0.18 0,23 0.45 0.42 0.26 0.19 0.16 0.12 0.11
%Released: 100% PM 0.16 0.17 0.25 0.27 0.34 0.55 0.6 0.88 1 0.88 0.51 0.28
Igts-out peak: 61 W AM 1 1 1 1 1 0.75 0.75 0 0 0 0 0
%Released: 0% PM 0 0 0 0 0 0 0 0.5 0.75 0.75 0.75 1
Igts-gar peak: 0 W AM 0 0 0 0 0 0.5 0.75 1 0.75 0.5 0 0
%Released: 0% PM 0 0 0.5 0.5 0.75 1 0.75 0.5 0 0 0 0
MEL peak: 0 W AM 0.5 0.5 0.5 0.75 0.76 0.85 1 1 1 1 0.9 0.9
To Released: 90% PM 0.9 0.9 1 1 1 1 1 1 1 0.85 0.75 0.75
y
5/11/2017 9:05 AM EnergyGauge®!USRCZB v5.1 Page 6 of 6
Florida Code 2014 Summary Report
CROUCH Title:CROUCH TMY City: FL_VERO_BEACH_
8280 GERMANY CANAL RD FLProp2014 Elec Util: EnergyGauge Default
PORT ST LUCIE, FL, Gas Util: EnergyGauge Default
Registration#: Run Date:
Energy_Uses _______._Reference Home _ Proposed Home _ _ a-Ratio
Heating 1.23 MBtu 0.91 MBtu 0.74
Cooling 20.56 MBtu 19.96 MBtu 0.97
Hot Water 8.80 MBtu 8.74 MBtu 0.99
Total 30.59 MBtu 29.61 MBtu 0.97
Building Loads Reference Home _^ Proposed Home _ _ e-Ratio
Heating 3.17 MBtu 2.36 MBtu* 0.74
Cooling 68.35 MBtu 66.35 MBtu* 0.97
Hot Water 8.59 MBtu 8.53 MBtu* 0.99
Total 80.11 MBtu 77.24 MBtu 0.96
*normalized modified loads
Glass/Floor Area: 0.112 Total Proposed Modified Loads: 77.24 PASS
Total Reference Loads: 80.11
M.
r
5/11/2017 9:05 AM EnergyGauge®USA-RaRes2014/ Page 1 of 1
FFORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CROUCH Builder Name: OWNER
Street: 8280 GERMANY CANAL RD Permit Office:
City,State,Zip: PORT ST LUCIE,FL, Permit Number:
Owner: CROUCH Jurisdiction:
Design Location: FL,Fort Pierce
COMPONENT CRITERIA CHECK
9 e.
A continuous air barrier shall be installed in the building envelope.
Air barrier and thermal barrier P
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
r Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior wails,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
5/11/2017 9:05 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1