HomeMy WebLinkAboutEnergy Calculation Form & Manual J's (2) FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index,the more efficient the home. 8280 GERMANY CANAL RD, PORT ST LUCIE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1728.00 ft2 b.N/A R= ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.NIA R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=33.0 2597.00 ft2 -6. Conditioned floor area(ft2) 2597 b.N/A R= ft2 7. Windows"* Description Area c.NIA R= ft2 a. U-Factor: Dbl,U=0.30 291.33 ft2 11.Ducts R ft2 SHGC: SHGC=0.29 a.Sup:Attic,Ret:Main,AH:Main 6 519.4 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 60.0 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 60.0 HSPF:8.70 Area Weighted Average Overhang Depth: 0.963 ft. Area Weighted Average SHGC: 0.290 8. Floor Types Insulation Area 14.Hot water systems a.Crawlspace R=11.0 2597.00 ft2 a. Electric Cap:50 gallons EF:0.95 b.N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15.Credits CF,Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �zKE STAT Construction through the above energy saving features which will be installed (or exceeded) = Fo in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. o Builder Signature: Date: Address of New Home: _ -� - —,`— — City/FL Zip: WE *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient -mortgage (EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/11/2017 9:06 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Residential System Sizing Calculation Summary CROUCH Project Title: 8280 GERMANY CANAL RD CROUCH PORT ST LUCIE, FL 5/11/2017 Location for weather data: Fort Pierce, FL -Defaults: Latitude(27.48) Altitude(25 ft.) Temp Range(L) Humidity data: Interior RH 50% Outdoor wet bulb 7817 Humidity difference 62 r. Winter design temperature(TMY3 99%) 40 F Summer design temperature(TMY3 99%) 91 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 30 F Summer temperature difference 16 F Total heating load calculation 21337 Btuh Total cooling load calculation 34602 Btuh Submitted heating capacity % of caic Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 281.2 60000 Sensible (SHR= 0.75) 179.1 45000 Heat Pump + Auxiliary(O.OkW) 281.2 60000 Latent 158.3 15000 Total Electric Heat Pump) 173.4 60000 WINTER CALCULATIONS Winter Heating Load for 2597 s ft Load component Load Window total 291 sqft 2622 Btuh Wall total 1377 sqft 3918 Btuh Walls(18.4%) Ceilings(10.6%) Door total 60 sqft 630 Btuh Ceiling total 2597 sqft 2265 Btuh W4ndows(12.3°/°) Floor total 2597 sqft 4109 Btuh Infiltration 103 cfm 3389 Btuh Floors(19.3%) Duct loss 4404 Btuh Subtotal 21337 Btuh , Ducts(20.6%) Ventilation 0 cfm 0 Btuh Ooors(3.0%) TOTAL HEAT LOSS 21337 Btuh Infil.(15.9%) SUMMER CALCULATIONS Summer Cooling Load for 2597 s ft Load component Load Window total 291 sqft 6748 Btuh N Wall total 1377 sqft 3801 Btuh Door total 60 sqft 651 Btuh Ceiling total 2597 sqft 3397 Btuh ° Ceilings(9.8%) Floor total 2202 Btuh Walls(11.0/o) Infiltration 77 cfm 1356 Btuh Windows(19.5%) Internal gain 2350 Btuh Floors(6.4%} Duct gain 4625 Btuh Doors(1.9%) Sens,Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh M. Total sensible gain 25129 Btuh Infil.(13.3%) Latent int(12.7%) Latent gain(ducts) 1825 Btuh Latent gain(infiltration) 3248 Btuh Int.Gain{6.8°io} Latent gain(ventilation) 0 Btuh Ducts(18.6%) Latent gain(internal/occupants/other) 4400 Btuh Total latent gain 9473 Btuh TOTAL HEAT GAIN 34602 Btuh EnergyGauge®System Sizing 8th Edition PREPARED BY: Gp DATE: 5-11-17 EnergyGauge®/USRCZB v5.1 System Sizing Calculations - Winter Residential Load - Whole House Component Details CROUCH Project Title: 8280 GERMANY CANAL RD CROUCH PORT ST LUCIE, FL Building Type: User 5/11/2017 Reference City: Fort Pierce, FL (Defaults) Winter Temperature Difference: 30.0 F(TMY3 99%) This calculation is for Worst Case.The house has been rotated 90 degrees. Component Loads for Whole House Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 2, NFRC 0.29 Vinyl 0.30 E 17.5 9.0 158 Btuh 2 2, NFRC 0.29 Vinyl 0.30 E 60.0 9.0 540 Btuh 3 2, NFRC 0.29 Vinyl 0.30 E 15.0 9.0 135 Btuh 4 2, NFRC 0.29 Vinyl 0.30 W 87.5 9.0 788 Btuh 5 2, NFRC 0.29 Vinyl 0.30 W 40.0 9.0 360 Btuh 6 2, NFRC 0.29 Vinyl 0.30 W 15.0 9.0 135 Btuh 7 2, NFRC 0.29 Vinyl 0.30 W 15.0 9.0 135 Btuh 8 2, NFRC 0.29 Vinyl 0.30 N 30.0 9.0 270 Btuh 9 2, NFRC 0.29 Vinyl 0.30 N 7.5 9.0 68 Btuh 10 2, NFRC 0.29 Vinyl 0.30 N 3.8 9.0 34 Btuh Window Total 291.3 s ft 2622 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame-Wood - Ext (0.095) 11.0/0.0 355 2.85 1009 Btuh 2 Frame-Wood - Ext (0.095) 11.0/0.0 77 2.85 219 Btuh 3 Frame-Wood -Ext (0.095) 11.0/0.0 300 2.85 854 Btuh 4 Frame-Wood -Ext (0.095) 11.0/0.0 367 2.85 1043 Btuh 5 Frame-Wood - Ext (0.095) 11.0/0.0 279 2.85 793 Btuh Wall Total 1377 s ft 3918 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood - Exterior, n (0.350) 20 10.5 210 Btuh 2 Wood -Exterior, n (0.350) 20 10.5 210 Btuh 3 Insulated -Exterior, n (0.350) 20 10.5 210 Btuh Door Total 60 s ft 63013tuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Vented Attic/L/Shing (0.029) 33.0/0.0 2597 0.9 2265 Btuh = .Ceiling Total 2597 s ft 226513tuh Floors Type Ueff, R-Value Size X HTM= Load 1 Stem/Crawisp(Tile)(v) (0.075) 11.0/0.0 2597.0 sqft 1.6 4109 Btuh Floor Total 2597 s ft 4109 Btuh Envelope Subtotal: 13544 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.30 20776 1.00 102.8 3389 Btuh Duct load Average sealed, R6.0, Supply(Att), Return(Con) (DLM of 0.260) 4404 Btuh All Zones Sensible Subtotal All Zones 21337 Btuh EnergyGauge®/USRCZB v5.1 Page 1 Manual J Winter Calculations Residential Load - Component [details (continued) CROUCH Project Title: 8280 GERMANY CANAL RD CROUCH PORT ST LUCIE, FL Building Type: User 5/11/2017 HOLE.HOUSE TOTALS I Subtotal Sensible Heat Loss 21337 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 21337 Btuh EQUIPMENT 1. Electric Heat Pump # 60000 Btuh Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) , HTM-(ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge®/USRCZB v5.1 Page 2 System S"Min g Calculations - Summer Residential Load - Whole House Component Details CROUCH Project Title: 8280 GERMANY CANAL RD CROUCH PORT ST LUCIE, FL 5/11/2017 Reference City: Fort Pierce, FL Temperature Difference: 16.OF(TMY3 99%) Humidity difference: 62gr. This calculation Is for Worst Case,The house has been rotated 90 degrees. "s,f6r Whole,House. Type* Overhang r--Window-Area-(-s-q-ft)---"'- HT _�Load Window Panes SHGG U InSh IS Ornt Len Hgt Gross Shaded Unshade Shaded U'�ns�haded *_ -J 1 2 NFRC 0.29,0.30 B-L No E 0.5ft. 0.7ft. 17.5- 0.0 17.5 8 23 406 Btuh 2 2 NFRC 0.29,0.30 B-L No E 0.5ft. 0.7ft. 60,0 0.0 60.0 8 23 1391 Btuh 3 2 NFRC 0.29,0.30 B-L No E 9.5ft. 0.7ft. 15.0 15.0 0.0 8 23 116 Btuh 4 2 NFRC 0.29,0.30 B-L No W 0.5ft. 0.7ft. 87.5 0.0 87.5 8 23 2028 Btuh 5 2 NFRC 0.29,0.30 B-L No W 0.511. 0.7ft. 40.0 0.0 40.0 8 23 927 Btuh 6 12 NFRC 0.29,0.30 B-L No W 0.5ft. 0.7ft. 15.0 0.0 15.0 8 23 348 Btuh 7 2 NFRC 0.29.0.30 B-L No W 0.5ft. 0.7ft. 15.0 0.0 15.0 8 23 348 Btuh 8 2 NFRC 0.29,0.30 B-L No N 0.5ft. 3.Oft. 30.0 0.0 30.0 8 8 231 Btuh 9 2 NFRC 0.29,0.30 B-L No N 0.5ft. 3.Oft. 7.5 0.0 7.5 8 8 58 Btuh 10 2 NFRC 0.29,0.30 B-L No N 0.5ft. 2.Oft. 3.8 0.0 3.8 8 8 30 Btuh Excursion 867 Btuh Window Total 29�1 (sqft)_ 6748 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath I Frame-Wood-Ext 0.09 11.0/0.0 354.5 2.8 979 Btuh 2 Frame-Wood-Ext 0.09 11.0/0.0 77.0 2.8 213 Btuh 3 Frame-Wood-Ext 0.09 11.0/0.0 300.0 2.8 828 Btuh 4 Frame-Wood-Ext 0.09 11.0/0.0 366.5 2.8 1012 Btuh 5 Frame-Wood-Ext 0.09 11.0/0.0 278.7 2.8 769 Btuh Wall Total 1377 (sqft) 3801 Btuh Doors Type T Area (sqft) HTM Load I Wood-Exterior 20.0 10.8 217 Btuh 2 Wood-Exterior 20.0 10.8 217 Btuh 3 Insulated-Exterior 20.0 10.8 217 Btuh sq ____ Door Total 60 (sl ft) 651 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM V Load I Vented Attic/Light/Shingle 0.029 33.0/0.0 2597.0 1.31 3397 Btuh Ceiling Total 2597 (sqft) 3397 Btuh Floors Type R-Value Size HTM Load I Stem/Crawlsp(v) 11.0 2597(sqft) 0.8 2202 Btuh Floor Total 2597.0 (sqft) 2202 Btuh Envelope Subtotal: 16799 Btuh Infiltration Type y Average ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.22 20776 1 77.1 1356 Btuh Internal Occupants Btuh/occupant Appliance Load -gain 5 X 230 + 1200 2350 Btuh Sensible Envelope Load: 20504 Btuh EnergyGauge@/USRCZB v5.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) CROUCH Project Title: Climate:FL VERO_BEACH_MUNICIPAL_A 8280 GERMANY CANAL RD CROUCH PORT ST LUCIE, FL 5/11/2017 Duct load Average sealed,Supply(R6.0_Attic),Retum(R6.0-Condi) -_ (DGM of 0.226) 4625 StUh Sensible Load All Zones 25129 Btuh a EnergyGauge®/USRCZB v5.1 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) CROUCH Project Title: Climate:FL VERO_BEACH_MUNICIPAL A 8280 GERMANY CANAL RD CROUCH PORT ST LUCIE, FL 5/11/2017 ` WHOLE HOUSE TOTALS - - Sensible Envelope Load All Zones 20504 Btuh Sensible Duct Load 4625 Btuh Total Sensible Zone Loads 25129 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 25129 Btuh Totals for Cooling Latent infiltration gain (for 62 gr. humidity difference) 3248 Btuh Latent ventilation gain 0 Btuh Latent duct gain 1825 Btuh Latent occupant gain(5.0 people @ 200 Btuh per person) 1000 Btuh Latent other gain 3400 Btuh Latent total gain 9473 Btuh TOTAL GAIN 34602 Btuh EQUIPMENT 1. Central Unit # 60000 Btuh 'Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device:none(No),Blinds(B),Draperies(D)or Roller Shades(R)) - For Blinds:Assume medium color,half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed ,: w (IS-Insect screen:none(N),Full(F)or Half(%)) " (Omt-compass orientation) Version 8 EnergyGaugeO/USRCZB v5.1 Page 3 System Sizing Calculations - Winter Residential Load - Room by Room Component Details CROUCH Project Title: 8280 GERMANY CANAL RD CROUCH PORT ST LUCIE, FL Building Type: User 5/11/2017 Reference City: Fort Pierce, FL (Defaults) Winter Temperature Difference: 30.0 F (TMY3 99%) This calculation is for Worst Case.The house has been rotated 90 degrees. Component Loads f®r Room#1 ;Main j �: f _ Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load 1 2, NFRC 0.29 Vinyl 0.30 E 17.5 9.0 158 Btuh 2 2, NFRC 0.29 Vinyl 0.30 E 60.0 9.0 540 Btuh 3 2, NFRC 0.29 Vinyl 0.30 E 15.0 9.0 135 Btuh 4 2, NFRC 0.29 Vinyl 0.30 W 87.5 9.0 788 Btuh 5 2, NFRC 0.29 Vinyl 0.30 W 40.0 9.0 360 Btuh 6 2, NFRC 0.29 Vinyl 0.30 W 15.0 9.0 135 Btuh 7 2, NFRC 0.29 Vinyl 0.30 W 15.0 9.0 135 Btuh 8 2, NFRC 0.29 Vinyl 0.30 N 30.0 9.0 270 Btuh 9 2, NFRC 0.29 Vinyl 0.30 N 7.5 9.0 68 Btuh 10 2, NFRC 0.29 Vinyl 0.30 N 3.8 9.0 34 Btuh Window Total 291.3(sqft) 2622 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) I Frame-Wood -Ext (0.095) 11.0/0.0 355 2.85 1009 Btuh 2 Frame-Wood -Ext (0.095) 11.0/0.0 77 2.85 219 Btuh 3 Frame-Wood -Ext (0.095) 11.0/0.0 300 2.85 854 Btuh 4 Frame-Wood -Ext (0.095) 11.0/0.0 367 2.85 1043 Btuh 5 Frame-Wood -Ext (0.096) 11.010.0 279 2.85 793 Btuh Wall Total 1377(sqft) 3918 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood- Exterior, n (0.350) 20 10.5 210 Btuh 2 Wood -Exterior, n (0.350) 20 10.5 210 Btuh 3 Insulated-Exterior, n (0.350) 20 10.5 210 Btuh Door Total 60(sqft) 63013tuh Callings Type/Color/Surface Ueff. R-Value Area X HTM= Load I Vented Aftic/L/Shlng (0.029) 33.0/0.0 2597 0.9 2265 Btuh CeilingTotal 2597(sqft) 226513tuh Floors Type Ueff. R-Value Size X HTM= Load 1 Stem/Crawisp(Tile)(v) (0.075) 11.0/0.0 2597.0 sqft 1.6 4109 Btuh Floor Total 2597 sqft 4109 Btuh Room Envelope Subtotal: 13544 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.30 20776 1.00 102.8 3389 Btuh Duct load Average sealed,Supply(RU-Attic),Retum(RU-Cond.) (DLM of 0.260) 4404 Btuh Room#1 Sensible Room Subtotal 21337 Btuh EnergyGauge@ USRCZB v5.1 Pagel V Manual J Summer Calculations Residential Load - Component Details (continued) CROUCH Project Title: Climate:FL_VERO_BEACH_MUNICIPAL A 8280 GERMANY CANAL RD CROUCH PORT ST LUCIE, FL 5/11/2017 w .WHOLE.HOUSE TOTALS Sensible Envelope Load All Zones 20504 Btuh Sensible Duct Load 4625 Btuh Total Sensible Zone Loads 25129 Btuh Sensible ventilation 0 Btuh y Blower 0 Btuh Whole House Total sensible gain 25129 Btuh Totals for Cooling Latent infiltration gain (for 62 gr. humidity difference) 3248 Btuh Latent ventilation gain 0 Btuh Latent duct gain 1825 Btuh Latent occupant gain(5.0 people @ 200 Btuh per person) 1000 Btuh Latent other gain 3400 Btuh Latent total gain 9473 Btuh TOTAL GAIN 34602 Btuh EQUIPMENT 1. Central Unit # 60000 Btuh *Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (lnSh-Interior shading device:none(No),Blinds(B),Drapedes(D)or Roller Shades(R)) - For Blinds:Assume medium color,half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed (IS-Insect screen:none(N),Full(F)or Half(%)) (Omt-compass orientation) Version 8 EnergyGauge®/USRCZB v5.1 Page 3 Residential Window Diversity MidSummer CROUCH Project Title: 8280 GERMANY CANAL RD CROUCH PORT ST LUCIE, FL 5/11/2017 W Summer design temperature 91 F Average window load for July 2837 Btuh Cooling setpoint 75 F Peak window load for July 4556 Btuh Summer temperature difference 16 F Excusion limit(130%of Ave.) 3689 Btuh Latitude 27.48 North Window excursion (July) 867 Btuh WINDOW Average and Peak Loads 4,500 4,000 ----------------------- ------------ ----------- 3,500 IT 3,000 2,500 2,000 All 1,500 8 10 12 14 16 18 20 Window Load (Btull) Limit for excursion 12 Hour Average Total July Window Load(Radiation and conduction) This application has glass areas that produce large heat gains for part of the day. Variable air volume devices are required to overcome spikes in solar gain for one or more rooms. Install a zoned system or provide zone control for problem rooms. Single speed equipment may not be suitable for the application. EnergyGauge@ System Sizing for Florida residences only PREPARED BY: GANNON BQGGS III DATE: 5-11-17 EnergyGauge@/USRCZ13 v5.1