Planning & Development Services; Building & Code Regulation Division
2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982
772-462-2165 Fax 772-462-6443
FBC ENERGY CONSERVATION CODE R402.4.1.2
House Infiltration Test (Blower Door) Certification
Prescriptive, and Performance Method
Date: Q3 ! 8 6 (? Permit #: 1703 6 6LI G
Contractor: Off► Mori nn
Job Address:
Construction: (\/) New Construction — Complete ( ) Existing — After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (50) = M7 Test Date: C73 A �7 aR
Volume = 23777
ACH (50) = CFM (50) x 60 / Volume = yo7 I Me anical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less ( ) Pass ( ) Fail
FBC, Energy
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting,
shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105
(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party
conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
FBC, Residential
R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when
tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402:4.1.2 of the Florida
Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in
accordance with Section M1507.3.
Testing Company �" %70 nCY 5 Harz 61YA *41()
Company Name: Sky�Te[ Address: 6ony11j
IP.A
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: New ,�ma
License/Certification #:
MAR o 8 2018
•�
0 -
Florida Building Code Duct Leakage Results
Builder: 0A
Neighborhood: cmeksi� Lot #: M' ; 9 o C)
Address: gs-!�6 C.bL64he orm
City: CKA Pieyice State: CL Permit #: r7o3 06,46
Square Footage: ZZ64
Stage of Construction for Test
Rough in with Air Handler F Rough in no Air Handler Post Construction
Duct Leakage Test Results:
Duct Leakage percent requirement: -_ %
System
CFM25
Square
Footage
Duct Leakage
(CFM/100s ft.
Location '
Pass or Fail
1
6&7-
370
2
3
4
5
Pass
Rating Company: SkyeTec°
Fail
Inspection Date: OS
Rater Name: _Q,ecp n2 uhpda
Rater Signature:
MAR o 8 2019
0
The Energy Code Experts
9570 Regency Square Blvd. Suite 410 Jacksonville, FL 32225
Phone: 904.482.4000 1 1.866.SKYETEC
www.SkyeTec.com