Loading...
HomeMy WebLinkAboutBlower Door Test•! Planning & Development Services; Building & Code Regulation Division 2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC ENERGY CONSERVATION CODE R402.4.1.2 House Infiltration Test (Blower Door) Certification Prescriptive, and Performance Method Date: Q3 ! 8 6 (? Permit #: 1703 6 6LI G Contractor: Off► Mori nn Job Address: Construction: (\/) New Construction — Complete ( ) Existing — After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) = M7 Test Date: C73 A �7 aR Volume = 23777 ACH (50) = CFM (50) x 60 / Volume = yo7 I Me anical Ventilation required less than 3 ACH Passing results must be & ACH (50) or less ( ) Pass ( ) Fail FBC, Energy R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting, shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402:4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company �" %70 nCY 5 Harz 61YA *41() Company Name: Sky�Te[ Address: 6ony11j IP.A I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: New ,�ma License/Certification #: MAR o 8 2018 •� 0 - Florida Building Code Duct Leakage Results Builder: 0A Neighborhood: cmeksi� Lot #: M' ; 9 o C) Address: gs-!�6 C.bL64he orm City: CKA Pieyice State: CL Permit #: r7o3 06,46 Square Footage: ZZ64 Stage of Construction for Test Rough in with Air Handler F Rough in no Air Handler Post Construction Duct Leakage Test Results: Duct Leakage percent requirement: -_ % System CFM25 Square Footage Duct Leakage (CFM/100s ft. Location ' Pass or Fail 1 6&7- 370 2 3 4 5 Pass Rating Company: SkyeTec° Fail Inspection Date: OS Rater Name: _Q,ecp n2 uhpda Rater Signature: MAR o 8 2019 0 The Energy Code Experts 9570 Regency Square Blvd. Suite 410 Jacksonville, FL 32225 Phone: 904.482.4000 1 1.866.SKYETEC www.SkyeTec.com