HomeMy WebLinkAboutEnergy Calculation Form & Manual J'sr
FORM R405-2014 V
j ,�a� �S I
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative(Performance) Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
* residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page) and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level(EPL) Display Card(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage`, then a completed
Form R405 Duct Leakage Test Report(usually one page)
FILE
EnergyGauge®-USRCZB v5.1
2/15/2017 11:33:40 AM Page 1 of 1
FORIM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Express FLORA RIGHT PSL Builder Name:
Street: Permit Office:
City,State,Zip: ST. LUCIE,FL, Permit Number.
Owner'. Express Homes Jurisdiction:
Design Location: FL,ST_LUCIE_CO_INTL County:: St.Lucie(Florida Climate Zone 2}
1. New construction or existing New(From Plans) 9. Wall Types(2467.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=13.0 1289.60 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 920.48 ft'
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 256.96 ft2
" 4. Number of Bedrooms 4 d.NIA R= ft'
10.Ceiling Types (1331.0 sgft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=38.0 1331.00 ft2
6. Conditioned floor area above grade(ft2) 2264 b.N/A R= ft'
c.NIA R= ft2
Conditioned floor area below grade(ft2) 0 11,Ducts R ft2
7, Windows(215.3 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 125
a. U-Factor: Dbl,U=0.34 174.49 ft2
SHGC: SHGC=0.35
b. U-Factor: Dbl,U=0.63 40.80 ft2 12.Cooling systems kBtu/hr Efficiency
a.Central Unit 49.0 SEER:15.50
SHGC: SHGC=0.32
c. U-Factor: NIA ft2
SHGC: 13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 45.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.420 ft.
Area Weighted Average SHGC: 0.344 14.Hot water systems
a.Electric Cap:50 gallons
8. Floor Types (2264.0 sqft.) Insulation Area EF:0.980
a.Slab-On-Grade Edge Insulation R=0.0 933.00 ft2 b. Conservation features
b.Floor Over Other Space R=13.0 895.00 ft2 None
c.other(see details) R= 436.00 ft2 15.Credits Pstat
G{ass/F{oor Area: 0.095 �7�7
Total Proposed Modified Loads: 65.55 PASS
~
Total Baseline Loads: 70.22
I hereby certify that the plarls,.and-pecifications covered by Review of the plans and _ESTD?
this calculation are in compliance with lorida Energy specifications covered by this 'ti�°°' �0
i,,
Code. I A calculation indicates compliance cge'csr,r ,n r
3 with the Florida Energy Code.
PREPARED BY: <(
Before construction is completed
DATE: this building will be inspected for .41f
compliance with Section 553.90$
rida ✓ "'L�� '
I hereby certify that"l�iis buildirig,'a"�Cl�stit ne�i§in compliance Flo Statutes.
with the Florida Energy- d � .
OWNER/AGENT:- BUILDING OFFICIAL:
DATE: DATE: _
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-seated in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 On for whole house.
2/1512017 11:33 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: Express FLORA RIGHT PSL Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2264 Lot#
Owner. Express Homes Total Stories: 2 Biock/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Rotate Angle: 135 Street:
Permit Office: Cross Ventilation: County: St.Lucie
Jurisdiction: Whole House Fan: City,State,Zip: ST. LUCIE,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,ST_LUCIE_CO_INTL FL VERO BEACH_MUNI 2 39 90 70 75 299 58 Medium
BLOCKS
Number Name Area Volume
1 Biockl 2264 18858.4
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1st Floor 933 8210.4 Yes 1 0 1 Yes Yes Yes
2 2nd Floor 1331 10648 No 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 129 ft 0 933 ft2 -- 0.7 0 0.3
2 Floor over Garage 2nd Floor _-_- — 436 ft2 0 0.7 0 0.3
3 Floor Over Other Space 2nd Floor 895 ft2 13 0.7 0 0.3
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1531 ft2 0 f12 Dark 0.9 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1369 ft2 N N
2/15/2017 11:33 AM EnergyGaugem USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 38 Blown 1331 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_ 1 N=>SE Exterior Concrete Block-Int Insul 1st Floor 4.1 39.8 0 8.8 0 350.2 ftz 0 0 0.8 0
2 W=>NE Exterior Concrete Block-Int Insul 1st Floor 4.1 27.4 0 8.8 0 241.1 ft2 0 0 0.8 0
_3 S=>NW Exterior Concrete Block-Int Insul 1st Floor 4.1 18.4 0 8.8 0 161.9 ft2 0 0 0.8 0
4 E=>SW Exterior Concrete Block-Int Insul 1st Floor 4.1 19 0 8.8 0 167.2 ft2 0 0 0.8 0
_ 5 S=>NW Garage Frame-Wood 1st Floor 13 21.4 0 8.8 0 188.3 ft2 0 0.8 0
i 6 E=>SW Garage Frame-Wood 1st Floor 13 7.8 0 8.8 0 68.6 ft2 0 0.23 0.8 0
7 N=>SE Exterior Frame-Wood 2nd Floor 13 39.8 0 8 0 318.4 ft2 0 0.23 0.8 0
8 W=>NE Exterior Frame-Wood 2nd Floor 13 40.8 0 8 0 326A ft2 0 0.8 0
9 S=>NW Exterior Frame-Wood 2nd Floor 13 39.8 0 8 0 318.4 ft2 0 0.8 0
10 E=>SW Exterior Frame-Wood 2nd Floor 13 40.8 0 8 0 326.4 ft2 0 0.23 0,8 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 S=>NW Insulated 1st Floor None .4 2.6 8 20.8 ft2
2 S=>NW Insulated 1st Floor None .4 3 6,8 20.4 ft2
WINDOWS
Orientation shown is the entered orientation(_>)changed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
i N=>SE 1 Vinyl Low-E Double Yes 0.34 0.35 46.8 ft' 1 ft 0 in 12 ft 0 in None None
2 N=>SE 1 Vinyl Low-E Double Yes 0.63 0.32 40.8 ft' 1 ft 0 in 12 ft 0 in None None
3 W=>NE 2 Vinyl Low-E Double Yes 0.34 0.35 15.6 ft2 1 ft 0 in 12 ft 0 in None None
4 S=>NW 3 Vinyl Low-E Double Yes 0.34 0.35 2.5 ft2 6 ft 0 in 1 ft 0 in None None
5 S=>NW 3 Vinyl Low-E Double Yes 0.34 0.35 15.6 ft' 6 ft 0 in 2 ft 0 in None None
6 N=>SE 7 Vinyl Low-E Double Yes 0.34 0.35 46.8 ft' 1 ft 0 in 0 ft 0 in None None
7 S=>NW 9 Vinyl Low-E Double Yes 0.34 0.35 16.0 ft' 1 ft 0 in 3 ft 0 in None None
8 S=>NW 9 Vinyl Low-E Double Yes 0.34 0.35 31.2 ft' 1 ft 0 in 3 ft 0 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 506 ft2 506 ft2 64 It 8.8 ft 13
2/15/2017 11:33 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000265 1571.5 86.28 162.25 .2444 5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 45 kBtulhr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15.5 49 kBtu/hr 1471 ofm 0.73 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.98 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ ---Supply-- — Return- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 125 ft2 Attic 50.2 W Prop.Leak Free 2nd Floor —cfm 67.9 cfm 0.03 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cool in ]Jan ]Feb Mar A r Ma Jun X Jul Au rj Se Oct NovDecHeating f X]Jan �X]Feb Mar f Apr f May Jun 4 Jul Aug Sep f Oct Nov Dec
Ventin [ ]Jan [ ]Feb X Mar (X A r [ Ma Jun ( Jul Au Se [X Oct Nov Dec
2/15/2017 11:33 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
f
2/15/2017 11:33 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM, R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the EnergyPerformance Index, the more efficient the home.
ST. LUCIE, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 1289.60 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 920.48 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13.0 256.96 ft2
~ 4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
S. Is this a worst case? Yes a. Under Attic(Vented) R=38.0 1331.00 ft2
6. Conditioned floor area(ft2) 2264 b.N/A R= ft2
7. Windows- Description Area c.N/A R= ft2
a. U-Factor. Dbl,U=0.34 174.49 ft2 11.Ducts R ft2
SHGC: SHGC=0.35
a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 125
b. U-Factor: Dbl, U=0.63 40.80 ft2
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 49.0 SEER:15.50
SHGC:
d. U-Factor. N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 1.420 ft.
a.Electric Heat Pump 45.0 HSPF:8.50
Area Weighted Average SHGC: 0.344
8. Floor Types Insulation Area 14.Hot water systems
2 a. Electric Cap:SO gallons
a.Slab-On-Grade Edge Insulation R=0.0 933.00 ft EF:0.98
b.Floor Over Other Space R=13.0 895.00 ft2
c.other(see details) R= 436.00 ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building �ftEST
Construction through the above energy saving features which will be installed (or exceeded) ti4T 3. ?C?o
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant atures.
Builder.Signature: Date: -2 . ..CA,11
� c
Address of New Home: 11lo G."
6 3� b S4VVLQ,, iD9- City/FL ZIP old
*Note: This is not a Building Energy Rating. if your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/15/2017 11:33 AM EnergyGauge&USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Permit Number.
ST. LUCIE,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy_Florida law
[Section 553.9085,Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains Information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
-0 R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 installation. The components of the building thermal envelope as listed in Table R4D2.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures:
2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures:
3.Interior doors, if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5. Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers, if installed at the time of the test,shall be fully open.
0 R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
0 R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1,5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Uslm2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
0 R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7,2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
2/15/2017 11:33 AM EnergyGauge(b USA-FlaRes2014 -Section R405.4.1 Corn Page 1 of 3
FORMA405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105•F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
• R403.4.4.1 Storage water heater temperature controls
• R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140'F(38°C to 60°C).
• R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in'installed solar water
heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal,and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturers product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
211 5/201 7 1 1:33 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Corn Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment_This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2, When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
0 R403.6.1.2 Heating equipment capacity
R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling toad.
R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2_ A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
0 R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
0 R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps-
0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
0 R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space,R-10 is allowed.
2/15/2017 11:33 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Express FLORA RIGHT PSL Builder Name:
Street: Permit Office:
City, State,Zip: ST. LUCIE,FL, Permit Number:
Owner: Express Homes Jurisdiction:
Design Location: FL,ST LUCIE_CO_INTL
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Comers and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
2/15/2017 11:33 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page i of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Express FLORA RIGHT PSL Builder Name:
Street: Permit Office:
City,State,Zip: ST. LUCIE,FL, Permit Number:
Design Location: FL,ST LUCIE_CO_INTL Jurisdiction:
Cond.Floor Area:: 2264 sq.ft. Cond.Volume: 18858 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
Single or Multi Point Test Data CFM(50):
l HOUSE PRESSURE J FLOW: I ELA.
EgLA:
ACH:
ACH(50):
SLA:
R412.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour
in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers, if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage Where required by the code official, OE Sr
f 0 rfi
performance results demonstrate compliance testing shall be conducted by an tiy _. 0
with Florida Energy Code requirements in approved third party. A written
accordance with Section R402.4.1.2. report of the results of the test shall fit,
be a- o
be signed by the third party
conducting the test and provided to
SIGNATURE: the code official. ..
PRINTED NAME:
ab wE't�`
DATE: BUILDING OFFICIAL:
DATE:
211512017 1 1:33 AM EnergyGaugeG USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Report
i
Form R405 Duct Leakage Test Re p
Performance Method
Project Name: Express FLORA RIGHT PSL Builder Name:
Street: Permit Office:
City,State,Zip: ST. LUCIE,FL, Permit Number.
Design Location: FL,ST_LUCIE_CO_INTL Jurisdiction:
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
1 System 1 cfm25(Out)
2 System 2 1 cfm25(Out)
3 System 3 cfm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines 1-4
Duct System Divide by
Leakage
(Total Conditioned Floor Area)
(Qn,Out)
l certify the tested duct leakage to outside, Qn, is
'� T�T�
not greater than the proposed duct leakage Qn Duct tightness shall be verified by Q{
testing to Section 803 of the RESNET
specified on Form R405-2014. Standards by an energy rater certified in
accordance with Section 553.99,
Florida Statutes,
SIGNATURE: fit. r
PRINTED NAME:
DATE: BUILDING OFFICIAL:
DATE:
2/15/2017 11:33 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1
Express Flora Right
HVAC Load Calculations
for
Express Homes
KS109 il'M.I.,
KIIVACHVAC LoAD9
Prepared By:
Kristin Kelly
Florida Breeze
6928 Vickie Circle Suite B
West Melbourne, FI 32904
321-951-8767
Wednesday, February 15,2017
Rhvac is an ACCA approved Manual J and Manual D computer program. FILE
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. COF
A yEliteSoftware,.Develo ment;lnc.
Rhvac Res10Wia!-&°L'+ght;Commerc al HVAC Loads.: 4 P T� j
A/C Service Masters,•.LL_G `Express Flora Righ#
I, Ralm Ba ,FL 32909 ;x ; Page 2 I
Pract Reo - --- _.�---.�_�_^'
__ . ?
j u al�Project�lnfci anon �m ' °° "`� 57,
. �"` � ."• �
Project Title: Express Flora Right
i Designed By: Kristin Kelly
Project Date: January 10, 2016
Client Name: Express Homes
Company Name: Florida Breeze
Company Representative: Kristin Kelly
Company Address: 6928 Vickie Circle Suite B
Company City: West Melbourne, Ft 32904
Company Phone: 321-951-8767
Deli•n Data � ' �; �
! Reference City: Fort Pierce, Florida
Building Orientation: Front door faces South
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft. I
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
I Winter: 42 39.4 n/a n/a 70 n/a
Summer: 90 78 59% 50% 75 61
Check Fr iafes .. ,,
Total Building Supply CFM: 1,589 CFM Per Square ft.-. 0.702
Square ft, of Room Area: 2,264 Square ft. Per Ton: 623
j Volume(ft3)of Cond. Space: 18,858
Total Heating Required Including Ventilation Air. 34,044 Btuh 34.044 MBH ..
Total Sensible Gain: 34,919 Btuh 80 %
Total Latent Gain: 8,706 Btuh 20 % 1
Total Cooling Required Including Ventilation Air: 43,625 Btuh 3.64 Tons(Based On Sensible+ Latent)
;Notes �`, �` •. , ,� a ,,r . ;, „ ..;
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
j All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
i
I
i
I
i
E:1...\EXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
Rti�Pac Residential&Light.6ommercial HVAC Loads Etite Software Development,Inc, 1
� �A/C Service Masters,�LLG �' .Express:Fiora Righf 1
i Pa(cn Ba_y FL 329D9 _ PBga 3
� S ste �p1 rW�ole 1=1t�u'se � ` " Qutetaor ��:$®t'atc#oot� "' ts3�tdaar indoo ' i"nciaor .y Grains �
Winter: 42 39.4 80% Na 70 n/a
Summer: 90 78 59% 50% 75 61.09
Duet�t2in :In UtBy-R .N, .<,� '`'' k� +�s ,.r �•. � .`r 'Y"s� �� � =n,�.. "e"i
h Main Trunk Runouts
Calculate: Yes Yes i
Use Schedule: Yes Yes
Roughness Factor: 0.01000 0.01000
Pressure Drop: 0.1000 in.wg./l00 ft. 0,1000 in,wg./100 ft.
Minimum Velocity: 550 ft./min 450 ft./min I
Maximum Velocity: 600 ft./min 750 ft./min i
Minimum Height: 0 in. 0 in,
Maximum Height: 0 in. 0 in.
I OUt5ltle�f'll'Data•" �� ;: �, 4 .�. ,, , � ,� - - -. .. �
Winter ,.. Summer
Infiltration Specified: 0.430 AC/hr 0.220 AC/hr
135 CFM 69 CFM
Infiltration Actual: 0.430 AC/hr 0.220 AC/hr
Above Grade Volume: X 18,858 Cu.ft. X 18,858 Cu.ft.
8,109 Cu.ft./hr 4,149 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 135 CFM 69 CFM
Total Building Ventilation: 0 CFM 0 CFM
---System 1---
Infiltration &Ventilation Sensible Gain Multiplier 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration &Ventilation Latent Gain Multiplier. 41.50 = (0.68 X 0.999 X 61.09 Grains Difference)
Infiltration &Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference)
Winter infiltration Specified: 0.430 AC/hr(135 CFM)
Summer Infiltration Specified: 0.220 AC/hr(69 CFM)
i
Duct LoadrFactor Scs'narios"forS stern'1 afi�
Atfic €}ue Duet Surfe From`
No.;..Tipe :_Desch tion Location: , z Ceiling Leakaefe Insulatioq Area
1 Supply Attic 166 -0.12 - 6 _-"754 No
1 Return Attic 16B 0.12 6 690 No
i
I
i
E:1...\EXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
Rhvacr Residential"&Light Commerctat H1/AC,Loads `` iElite'Softwaie Developments I
[[ 3 , - -Y ,r �
IY YCaService Masters,LLC�
�' ` ,. E cPress Flora, Right
P:al .Bay.F4t 32909i. Pa e4';
rLoad Preview Report
I Net ft 2 � Sen Lat� Net Sen Hts Ci Acctt Duct
Scope Ton !Tool Area, Gain GainIII Gain Lass CFM CFM CFM Size
Building 3.64 32,264 34,919 86 43,625 34,044 443 1,589 1,589 j
System 1 3.64 623 '2,264 34,919 8,706, 43,625 34;044: 443 t 58�3 r 1.589 i7
IDuct Latent 3.
3.61 3,361
- _
x20Zone1 2,264 34,919' 5,345. 40,264, 34,044: 443 1-689r 1,589 20
1-Post Floor 933 18,498 2,218 20,711 22,531: 293 842a 842; 5,5,5,5,55,
2-Second Floor 1,331 16,421 3,132i 19,553 11,613. 150, 74V 747: 5,5,5,5,5,
5,S
i
! I
1
i I
i
i
f 1
i I
V i
1 I
i
I
t
I �
I
• f I
f I
}
i
i
I
i
i
i
i
i
i
i
i
i
I
j
f
i
E:1...tEXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
Rhvac Residential&Light Commercial HVAC Loads Elite Software Qevelopmeni,,tnc] i
AIC`Servlce Allasters,:LLG, a,Ekpress Flora`Right j
Palm�,FL,329Q9 - -._"_ Page 511
-_- ---.w._ ---"-----_ '
i Total Building Summa`j''v Loads _
Component. 4 r� � � � � - Ar$a � Sefr s Lati iG Sen �} Total. f
M a Gain Gain,
Descrlpfion � Quan� Loss .,. Gain
2A-v-o: Glazing-Double pane low-e (e=0.60), operable 171.6 1,639 0 2,555 2,555
window, vinyl frame, u-value 0.34, SHGC 0.35
2A-v-d: Glazing-Double pane.low-e (e=0.60), sliding 40.8 720 0 660 660 1
glass door,vinyl frame, u-value 0.63, SHGC 0.32
2B-v-d: Glazing-Double pane low-e (e=0.60), fixed sash, 2.5 24 0 31 31
vinyl frame, u-value 0.34, SHGC 0.35
11J: Door-Metal- Fiberglass Core 41.2 692 0 642 642 I
13AB-Ofcs:Wall-Block, no blanket or board insulation, 778.8 3,991 0 2,479 2,479
filled core, siding finish
12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 1432.2 3,650 0 2,802 2,802
cavity, no board insulation, siding finish,wood studs
16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 2264 1,648 0 2,943 2,943
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-38 insulation
22A-pm: Floor-Slab on grade, No edge insulation, no 134 4,427 0 0 0
insulation below floor, any floor cover, passive, heavy
dry or light wet soil
Subtotals for structure: 16,791 0 12,112 12,112 i
People: 6 1,200 1,380 2,580 '
Equipment: 1,275 6,501 7,776
Lighting: 0 0 0
Ductwork: 13,094 3,361 13,786 17,147
Infiltration: Winter CFM: 135, Summer CFM: 69 4,159 2,870 1,140 4,010
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
Total Building Load Totals: 34,044 8,706 34,919 43,625
Glick ures =
Total Building Supply CFM: 1,589 CFM Per Square ft.: 0.702
Square ft. of Room Area: 2,264 Square ft. Per Ton: 623
Volume (ft')of Cond. Space: 18,858
Bui9clrng;lgads, ' :: < ,. ,
Total Heating Required Including Ventilation Air: 34,044 Btuh 34.044 MBH
Total Sensible Gain: 34,919 Btuh 80 %
Total Latent Gain: 8,706 Btuh 20 %
Total Cooling Required,Including Ventilation Air: 43,625 Btuh 3.64 Tons (Based On Sensible+ Latent)
i
Rhvac is an ACCA approved Manual J and Manual D computer program. 1
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
i
i
f
E:\ ,..\EXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
Rhuac Reside ntial&LrghtCamniercia)HVAC Loads, Elite_Software°Developmaoi,,lnc.!
s A/C Service,Masters,LLC, Express Flora Right
Palm Ba FL 32909 �- ^-__ ,Page 66 j
System 1 Whole House Summary Loads
Component��
Descriptions nY ,Quan, Loss"= .: Gain•.. Gain .._.- Gain
2A-v-o: Glazing-Double pane low-e(e=0�60), operable 171.E 1,639 0 2,555 2,555
window, vinyl frame;u-value 0,34, SHGC 0.35 i
2A-v-d: Glazing-Double pane low-e (e=0.60), sliding 40.8 720 0 660 660
glass door,vinyl frame, u-value 0.63, SHGC 0.32
2B-v-d: Glazing-Double pane low-e (e=0.60), fixed sash, 2.5 24 0 31 31 i
vinyl frame, u-value 0.34, SHGC 0.35
11 J: Door-Metal- Fiberglass Core 41.2 692 0 642 642 j
13AB-Ofcs: Wall-Block, no blanket or board insulation, 778.8 3,991 0 2,479 2,479
filled core, siding finish
12C-Osw:Wall-Frame, R-13 insulation in 2 x 4 stud 1432.2 3,650 0 2,802 2,802
cavity, no board insulation, siding finish, wood studs
16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 2264 1,648 0 2,943 2,943 j
Floor(also use for Knee Walls and Partition
' Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal,Tar and Gravel or
Membrane, R-38 insulation
22A-pm: Floor-Slab on grade, No edge insulation, no 134 4,427 0 0 0
insulation below floor, any floor cover, passive, heavy
dry or light wet soil
Subtotals for structure: 16,791 0 12,112 12,112 i
People: 6 1,200 1,380 2,580
Equipment: 1,275 6,501 7,776
Lighting: 0 0 0 j
1 Ductwork: 13,094 3,361 13,786 17,147 I
Infiltration: Winter CFM: 135, Summer CFM:69 4,159 2,870 1,140 4,010 i
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
System 1 Whole House Load Totals: 34,044 8,706 34,919 43,625
CheckFI ures � f; "-�
Supply CFM. 1,589 CFM Per Square ft.: 0.702
Square ft. of Room Area: 2,264 Square ft. Per Ton: 623
Volume(W)of Cond. Space: 18,856
Total Heating Required Including Ventilation Air: 34,044 Btuh 34.044 MBH I
Total Sensible Gain: 34,919 Btuh 80 %
Total Latent Gain: 8,706 Btuh 20 %
Total Cooling Required Including Ventilation Air: 43,625 Btuh 3.64 Tons (Based On Sensible+ Latent)
vas",( ✓u-, aaa. ,� 'A�S, a.K. �°
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
E:\...\EXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
Rhvac-Residential&Light Commercial HVAC Loads- Elrte Software Development„hc:
A!C Service Masters LI;C � ' 'Fxpress_Flora Right
Paling,FL.32909, " ' .� P,Bge 7 j
Equipment b6fi - System I/V iole Hoes
Cooling
j System Type: Air Source Heat Pump
I Outdoor Model: 25HBC548A**30
i Indoor Model: FV4CNB006
Tradename: CARRIER AIR CONDITIONING
i Outdoor Manufacturer: CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
AHRI Reference No.: 3646316
Capacity: 49400 i
i
Efficiency: 15.5 SEER
Heating
System Type: Air Source Heat Pump
Model: 25HBC548A**30
Tradename: CARRIER AIR CONDITIONING I
Manufacturer. CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
Capacity: 45000
{ Efficiency: 8.5 HSPF
I
I
This system's equipment was selected in accordance with ACCA Manual S.
Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB:42F, S B: 75F, SIRH: 50%,WIDB: 70F, Sen. gain:
34,919 Btuh, Lat. gain: 8,706 Btuh, Sen. loss: 34,044 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB. 62.5F, i
Entering htg, coil DB:70F, Clg. coil TD: 20F, Htg.coil TD: 70F, Req.clg. airflow: 1589 CFM, Req. htg. airflow:443 CFM
i
I
I
j
i
i
f
I 1
I
i
! I
I
i
i
i
I
1
I
E:1...\EXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
Rhyac.-Residential B-Light Commercial HVAC Loads Elite Soffware`Development,Inc-
I A/C Service Masters,LLC:; Express Flora Right
l Palm,B4j;FL 32909
wmr ----
System I Room Load Summary
--Zone 1-
1 First Floor 933 22,531 293 5,55,5, - 18,498 2,213 842 842
5,5,5,5,
5,5,5
2 Second Floor 1,331 11.513 150 5,5,5,5, - 16,421 3,132 747 747
5,5,5,5,
5555
Duct Latent 3,361
System 1 total 2,264 34,044 443 34,919 8,706 1,589 1,589
System 1 Main Trunk Size: 17 in.
Velocity: 1,009 ft./min j
Loss per 100 ft.: 0.080 in.wg
Duct size results above are from Manual D Ductsize.
Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room.
See the Manual D Ductsize report for duct velocities and other data.
'Cocain ern Summa .,
Ca hng* SensibfelLatent` en le
[c p {,
Y 4 rac ,�ryw7 �t.rx6'.:dk"w,w ,� t` ,..13tuh, ��"'*h....: E3tuh Btuft: !
. Tans_ .- �- ... ;
Net Required: 3.64 80%/20% 34,919 8,706 ' 43,625
Actual: 4.12 87%/ 13% 42,943 6,457 U 49.,400
Equroment'Data
Heating System Coolin4 System
Type: Air Source Heat Pump Air Source Heat Pump
Model: 25HBC548A**30 25HBC548A**30
Indoor Model: FV4CNB006
Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING
Description: Air Source Heat Pump Air Source Heat Pump j
Efficiency: 8.5 HSPF 15.5 SEER
Sound: 0 0 {
Capacity: 45,000 Btuh 49,400 Stuh I
Sensible Capacity: n/a 42,943 Stuh
Latent Capacity: n/a 6,457 Btuh
AHRI Reference No.: n/a 3646316
This system's equipment was selected in accordance with ACCA Manual
Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: I
34,919 Btuh, Lat. gain: 8,706 Btuh, Sen. loss: 34,044 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB:62.5F,
Entering htg. coil DB: 70F, Clg. coil TD:20F, Htg. coil TD: 70F, Req. clg. airflow: 1589 CFM, Req. htg. airflow:443 CFM
,
E:\...\EXPRESS 2263 FLORA PSL RIGHT NEW.rh9 Wednesday, February 15, 2017, 11:19 AM
i
'Residential Form
Plans Examiner Review Form
ACC-k- for HVAC System Deslan (Loads, Equipment, Du
RPER 1.01
Air0.6b,";CUrY.xi dkI,-a
County, Town, Municipality, Jurisdiction
Header Information
Contractor Florida Breeze REQUIRED ATTACHMENTS' ATTACHED
Manual J1 Form(and supporting worksheets): Yes❑X No❑
Mechanical License# CAC1814113 or MJ1AE Form=(and supporting worksheets): Yes❑ No QX
OEM performance data(heating,cooling,blower): Yes QX No❑
Building Plan# Manual D Friction Rate Worksheet: Yes❑ No QX
Duct distribution system sketch: Yes❑ No QX
Home Address(Street or Lot#, Block, Subdivision)
• .D . , • 41
Design Conditions Building Construction Information
Winter Design Conditions Building
Outdoor temperature 42 OF Orientation(Front door faces) South
Indoor temperature 70 OF worth,East,west, South,Northeast,Northwest,Southeast,Southwest
Btu/h
Total heat loss
34044 Number of bedrooms 5
Summer Design Conditions Conditioned floor area 2263 Sq Ft
Outdoor temperature 90 OF Number of occupants 6
Indoor temperature p 75 OF Windows Roof
Grains difference 61 L Gr @ 50 % Rh Eave overhang depth 2.4 Ft
Sensible heat gain 34919 Btu/h Internal shade <
Eave
Latent heat gain 8706 Btu/h Blinds,drapes,etc Depth Window
Total heat gain 43625 Btu/h Number of skylights 0
iViVAC EQU1PMENT SELECTION41
-Heating Equipment Data Cooling Equipment Data Blower Data
Equipment type Heat pump Equipment type Heat pump Furnace,Heat pump,Boller,etc. Air Conditioner,Heat pump,etc Heating CFM 1 671 CFM
Model 25HBC548A**30 Model 25HBC548A**30
Cooling CFM 1671 CFM
Heating output capacity 45000 Btu/h Sensible cooling capacity 42943 Btu/h
Heat pumps-capactry at winter design outdoor conditions 64 5 7
Latent cooling capacity Btu/h
Auxiliary heat output capacity . Btu/h Total cooling capacity 49400 Btu/h
,HVIAC DUCT DISTRIBUTION SYSTEM 1 •/
Design airflow 1501 CFM Longest supply duct: 60 Ft Duct Materials Used(circle)
Trunk Duct: Duct board Flex,Sheet metal,
External Static Pressure(ESP) 0.33 IWC Longest return duct: 30 Ft Lined sheet metal, Other (specify)
Component Pressure Losses(CPL) 0.25 IWC Total Effective Length(TEL) 90 Ft
Branch Duct: Duct board,flexSheet metal,
Available Static Pressure(ASP) 0.077 IWC Friction Rate: 0,09 IWC Lined sheet metal, Other(specify)
ASP=ESP•CPL Friction Rate=(ASP x 100)-TEL
declare the load calculation,equipment selection,and duct system design were ngorously performed based on - building plan listed
above, I understand the clairns made on these forms will be subject to review and verification.
Contractor's Printed Name Kristin Kelly Date 1/10/2016
Contractor's Signature
1
Reserved
for use by • Town, •. or Authority having jurisdiction.
The AHJ shall have the discretion to accep t Required Attachments printed from approved ACCA software vendors,see l st on page 2 of instructions.
' If abridged version of Manual J is used for load calculation,then verify residence meets requirements,see Abridged Edition Checklist on page 13 of instructions.
Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program.
• FEATURES
Environmentally Sound Refrigerant Technology
• PuronD,chlorine-free non-ozone depleting refrigerant
• Thermostatic Expansion Valve(TXV)designed to maximize performance with Puron®refrigerant
Energy Efficient Operation
• Electronically Commutating Motor(ECM)operates efficiently at all speeds
• Maximizes efficiency of heating and cooling systems
• Ultra low power consumption during fan only operation
Indoor Weather Control
• Warm,comfortable heating air temperatures
• Unmatched humidity control,especially with Carrier's Thermidistat`" Control
Airflow and Sound Technology
• Diffuser air discharge section for high airflow efficiency and quiet,smooth operation
• High duct static capability
• r! Jnique catitnet pie.`siga;thni_titeeisnewstiingent regujanons for ail 1e;11,ag ..Mets iequiremenb.of a?�i'o,`c_att►ne;t¢ai,age.fate�t hii eatzi3._aii
z1�O;iuches.ofisi�Sic:pressiiri:l
Condensate Control and Disposal Technology
• Minimal standing waterless microbial growth-for improved IAQ and reduced condensate line clogging and related condensate leakage
• Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance
• Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary
line conditions
•Tested for condensate disposal at conditions much more severe than those required by AHRI
• Primary and secondary drain connections to comply with HUD
• All pans constructed of an injection molded glass-filled polycarbonate engineered resin material,with brass drain connections.
• High density,super thick cabinetry insulation with vapor barrier
• Pre-painted galvanized sheet metal cabinet
Heat Transfer Technology
• Grooved copper tubing
• Lanced sine wave aluminum fins
• Discreet refined counter-flow refrigerant circuitry
r • Bi-flow hard shut-off TXV metering device
• ArmorCoat M coil protection available
Quality Assisting,Ease of Installation and Service Features
• All units multipoise
• Provision made for suspending from roof or ceiling joints
• Modular cabinet on 003 thru 006 units
• Sweat connections for leak free service
• Multiple electrical entry for application flexibility(high and low voltage)
• Low voltage terminal strip,to safely hold connections within the cabinet
• Inspection plate on A-coil models for quick coil cleanliness inspection
• Cabinet construction features innovations designed to prevent cabinet sweating
Controls and Electrical Features
• Easv Select' Board to maximize comfort,efficienev,and safe heater airflow operation
• Easy plug connection provided for quick installation of accessory heater packages
• 40VA 208/230v transformer
• Replaceable 5-amp blade-type auto fuse protects against transformer secondary short
Filter Features
• Factory supplied filter
• Cleanable polyester filter media
• Filter"springs"out for easy access-no tools required
• Newly improved filter rack area-filter door insulation added for an improved air seal
2