Blower Door Test
Planning & Development Services; Building & Code Regulation Division 2300 Virginia Ave, Rm 201; Fort Pierce, FL 34982 772-462-2165 Fax 772-462-6443 FBC ENERGY CONSERVATION CODE R402.4.1.2 RECEIVED House Infiltration Test (Blower Door) Certification MAR 2 9 7010 Prescriptive and Performance Method Permitting Departme, St. Lucie county Date: _ as Y2 i ko I ?, Permit #: ao?, 6147 Contractor: fv i- 0140r-\ Job Address: AS ',S �V Construction: (✓) New Construction — Complete ( ) Existing —After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) _ 1'65C, Volume = 2j 7LO ACH (50) = CFM (50) x 60 / Volume = Q5 Passing results must be & ACH (50) or less Test Date: cql �21 1Z� i YS M�hanical Ventilation required less than 3 ACH (✓) Pass ( ) Fail FBC, Energy R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Texting shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential R303.4 Mechanical ventilation. Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: ICE Address: g570 Ae5evicy& 9W ++L)IU .,j kck'iolgd�; �l I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Q;Ocp=�P'&CujyeclA License/Certification #: _ 1 y X C V8 1 -7©3 -U'aq? Florida Building Code Duct Leakage Results Builder: 06 1Aoc-4n Neighborhood: CyeLiA-s Lot #: Ck5.O 87 Address: B7 06661-fe Drive City: rOf� NCX-c�_ State Square Footage: 2605 Stage of Construction for Test CL Permit #: Rough in with Air Handler 0 Rough in no Air Handler Duct Leakage Test Results: Duct Leakage percent requirement: _ _-� % RECEIVED MAR-2 9 7010 Post ConstructiorPermlttin 9 D epartmen St. Lucie Countv System CFM25 Square Footage Duct Leakage CFM/100s ft.) Location Pass or Fail 72 -2 2605 2.8 v . ��� � Pas 2 3 4 5 111�� 11 Pass Rating Company: SkweTec® Fail Inspection Date: 03 ZI 201� Rater Name: oiC:t� ' Jye�C�. I Rater Signature: .Sjq�gTec The Energy ... Experts 9570 Regency Square Blvd. Suite 410 Jacksonville, FL 32225 Phone: 904.482.4000 1 1.866.SKYETEC www.SkyeTec.com RECEIVED tAAR` 2 9 2010 Permitting Department St. Lucie County