Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Meth&&ED C 2 1011 ProjectName: BOWMAN ADDITION BuilderName: Street: 6505 FORT WALTON RD. PermitOfrice: ST. LUCIE COUNTY Permitting Dapartm City, State, Zip: FT. PIERCE, FL, PermitNumber: St. Lucia Ccu rty Owner: DUANE & ALLISON BOWMAN Jurisdiction: 6611000 DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 16. Wall Types(1152.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Frame -Wood, Exterior R=11.0 1152.00ft' b. N/A R= ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms (Be' drms In Addition) 3(1) d. N/A R= ft' 11. Ceiling Types (1175.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1175.00 ft7 6. Conditioned floor area above grade (ft') 1175 b. N/A R= ft' Conditioned floorarea belowgrade (ft� 0 c. N/A R= ft' 7. Windows(138.5 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: EXISTING R ft' 6 35 a. U-Factor: Sgl, U=0.79 81.00 ft' � SHGC: SHGC=0.50 b. U-Factor: ; Sgl, U=0.30 48.00 ft' 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 23.0 SEER:14.00 c. U-Factor: Sgl, U=0.29 9.50 ft' SHGC: SHGC=0.24 Area Weighted Average Overhang Depth: 2.000 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.389 a. Electric Strip Heat 17.0 COP:1.00 8. Skylights ' Area c. U-Factor:(AVG) N/A ft' 15. Hot water systems -Replacementequipment SHGC(AVG): N/A a. Electric Cap:40 gallons 9. Floor Types (1175.0 sgft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 1175.00 ft' b. Conservation features b. N/A R= ft' None c. N/A R= ft' 16. Credits CF, Pstat Glass/Floor Area: 0.118 Total, Proposed Modified Loads: 34.41 PASS Total Baseline Loads. 34.6 i I hereby certify that the plans and specifications covered by Review of the plans and'f.5�'q. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPAR 2 Y' 2 DATE. �0 Before construction is completed this building will be inspected for compliance with Section 553.908 G ... . ., . I hereby certify that this building, as designed, its in compliance Florida Statutes. y - with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: i - Compliance requires certification by the aIir handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requiresian Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). I 2/23/2021 10:40 AM 7.0.00 FlaRes202O FBC 7th Edition (2020) Compliant Softw PY4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BOWMAN ADDITION Bedrooms: 3 Address Type: StreetAddress Building Type: User I ConditionedArea: 1175 Lot# OwnerName: DUANE & ALLISON BOWMA Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 6505 FORT WALTON R Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: 66110,60 Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Detached FL, New/Existing: Addition Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V DesignLocation TMY Site 97.5 % 2.5 % Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL VERO_BEAICH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume I 1 Entire House 11751 9400 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 EXISTING 875 7000 No 0 2 1 Yes Yes Yes 2 NEW MASTER 180 1 1440 No 2 1 1 Yes Yes Yes 3 WIC 25 200 No 0 1 No Yes Yes 4 LAUNDRY 35 280 No 0 1 Yes Yes Yes 5 NEW BATH 60 480 I No 0 1 Yes Yes Yes FLOORS # Flooi,4.e Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation EX I95 ft 0 875 ft' ---- 0 1 0 2 Slab -On -Grade Edgelnsulation NEW, MASTER 27 ft 0 180 ft' ---- 0 1 0 3Slab-On-Grade Edge Insulation WIC 1 ft 0 25ft' ---- 0 1 0 4 Slab -On -Grade Edge Insulation LAUNDRY 7 ft 0 35 ft' _--- 0 1 0 5 Slab -On -Grade Edge Insulation NEW BATH 15 ft 0 60 ft' ---- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) I 1 Hip Compositionshirjgles 1239 ft' 0 ft' Light N 0.5 No 0.7 No 20 18.43 ATTIC V # Type VenI ilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1175 ft' N N i 2/23/2021 10:40 AM 7.0.00 FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 ; INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Unvented) EXISTING 0 Blown 875ft2 0.1 Wood 2 UnderAttic(Unvented) NEW MASTER 0 Blown 180ft2 0.1 Wood 3 Under Attic(Unvented) WIC 0 Blown 25ft2 0.1 Wood 4 UnderAttic(Unvented) LAUNDRY 0 Blown 35 ft2 0.1 Wood 5 UnderAttic(Unvented) NEW BATH 0 Blown 60ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Frame -Wood EXISTING 11 35 0 8 0 280.0ft2 0 0.25 0.5 0 2 S Exterior Frame -Wood EXISTING 11 35 0 8 0 280.0ft2 0 0.25 0.5 0 3 W Exterior Frame -Wood EXISTING 11 25 0 8 0 200.0ft2 0 0.25 0.6 0 4 E Exterior Frame -Wood NEW MASTE 11 15 0 8 0 120.0ft2 0 0.25 0.5 0 5 S Exterior Frame -Wood NEW MASTE 11 12 0 8 0 96.0ft2 0 0.25 0.5 0 6 N Exterior Frame -Wood LAUNDRY 11 7 0 8 0 56.0ft2 0 0.25 0.5 0 7 N Exterio,r Frame -Wood NEW BATH 11 5 0 8 0 40.0ft2 0 0.25 0.5 0 _ 8 E Exterior Frame -Wood NEW BATH I 11 10 0 8 0 80.0f? 0 0.25 0.5 0 DOORS # Omt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated EXISTING None .32 3 6 8 20 ft2 2 S. Insulated NEW MASTE None .32 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall: Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 N 1 Metal Single(Clear) Yes 0.79 0.5 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 2 N 1 Metal Low ESingle Yes 0.29 0.24 N 4.8 ft2 2 ft 0 in 1 ft 4 in None None 3 S 2 Metal Single(Clear) Yes 0.79 0.5 N 48.0 ft2 2 ft 0 in 1 ft 4 in None None 4 S 2 Metal Low-ESingle Yes 0.3 0.23 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 5 W 3 Metal Single(Clear) Yes 0.79 0.5 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 6 S 5 j Metal Low-ESingle Yes 0.3 0.23 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 7 N 7 Metal Low-ESingle I Yes 0.29 0.24 N 4.8 ft2 2 ft 0 in 1 ft 4 in None None ' I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 783.3 42.98 80.68 .0902 5 2/23/2021 10:40 AM 7.0.001- FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 ElectricStrip Heat/None (Base[ None COPA 17kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/None(Baseline as Split Single SEER:14 23 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electr c None LAUNDRY 0.95 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# CollectorModel# Area Volume FEF None None I I ft2 DUCTS — Supply-- -- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area I Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 35 ft2 Attic 5 ft2 DefaultLeakage EXISTING (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat:i Y Ceiling Fans: CoolingJan [�] Feb Mar HeatinH Jan N Feb Hx Mar Apr M Apr [[ j May j Jun [X] Jul [ ]May n Jun [ ] Jul X AugX] 4 � Aug Se i Sep Oct Nov E Oct f � Nov HDe c DecVentin Jan [[ 11 Feb Mar Apr [[ ] Ma ] Jun [ ] Jul [ Au E ] Se [X] Oct [X Nov Dec ThermostatSchedule: HERS2006Reference Hours ScheduleType 1 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 j 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 6B 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ft2 Oft 0.3 EXISTING Default(8lbs/sq.ft. ft2 ft 0.3 NEW MASTER Default(8lbs/sq.ft. I ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default 8lbs/s .ft. it, ft 0.3 NEW BATH I 2/23/2021 10:40 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4 RECEIVED 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA . MAR 2 2 1011 Permitting Lapartment St. Lucia Ccurat? Project Name: 'BOWMAN ADDITION Builder Name: Street: i 6505 FORT WALTON RD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE , FL , Permit Number: x Owner: : DUANE & ALLISON BOWMAN Jurisdiction: 6611000 w Design Location: AFL, Fort Pierce i v COMPONENT AIR (BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the airi barrier shall be sealed. not be used as a sealingmaterial. The air barrier in any dropped ceiling/soffit shall be aligned with Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls be Cavities within comers and headers of frame walls be insulated shall shall by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors !The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls lExposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation Ja Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations "Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring ' and plumbing in exterior walls, or insulation that on I installation readily conforms to available space shall =end behind p6pong and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return relgister boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. .� Ir....1.diH.... i.r.�.....i,....ci Caulking or other adhesives sealants shall not be used to fill voids 6etween fire 1__ Osprinkler --``J late and walls or ceilings. ...�— •-- o. lu PYYI\IVI1, 1"3136ldIUI I WI Gg walls slldll Ou 111 duCuluGnce with the provisions or IUU-4uu. 2/23/2021 10:41 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 I ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows' Description a. U-Factor. Sgl, U=0.79 SHGC: SHGC=0.50 b. U-Factor: Sgl, U=0.30 SHGC: SHGC=0.23 c. U-Factor: Sgl, U=0.29 SHGC: SHGC=0.24 d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 9. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 6505 FORT WALTON RD., FT. PIERCE, FL, Addition 10. Wall Type and Insulation Detached a. Frame - Wood, Exterior b. N/A 1 c. N/A 3(1) d. N/A No 11. Ceiling Type and insulation level a. Roof Deck (Unvented) 1175 b. N/A c. N/A Area 12. Ducts, location & insulation level 81.00 ft2 a. Sup: Attic, Ret: Attic, AH: EXISTING i i Insulation R=0.0 R= R= I RECEIVED MAR 2 2 2021 Permitting D-apartment St. Lucie --oust/ Insulation Area R=11.0 1152.00 ft2 R= ft2 R= ft2 R= ft2 Insulation Area R=20.0 1175.00 ft2 R= ft2 R= ft2 R ft2 6 35 48.00 ft2 13. Cooling systems kBtu/hr Efficiency 9.50 ft2 a. Central Unit 23.0 SEER:14.00 ft2 14. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 17.0 COP:1.00 2.000 ft. 0.389 Area 15. Hot water systems - Replacement equipment 2 ft2 a. Electric Cap: 40 gallons EF: 0.95 b. Conservation features Area None 1175.00 ft2 Credits (Performance method) CF, Pstat ft2 ft2 I certify that this home Ihas complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 If the Florida Building Code, Energy Conservation, if not DEFAULT. 2/23/2021 10:40 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1