HomeMy WebLinkAboutEvaluation Report; 70 Series or V1 Series or (2127) Single-Hung WindowsBUILDING DROPS 398 East Dania Beach Blvd;
A Perfect Solution in Every Drop! Suite 338
Certificate of Authorization: 29578 Dania Beach, FL 33004
954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
Product Evaluation Report
of
American Craftsman Windows
Silver Line Windows and Doors
70 Series / V1 Series / (2127) Single -Hung Windows
(HVHZ) (NON -IMPACT)
for
Florida Product Approval
FL# FL14911
.= ;. ' ;. .
Current Florida Building Code
Method: 1— D (Engineering Evaluation)
Category: Windows
Sub — Category: Single Hung
Product: 70 Series / V1 Series / (2127) Single -Hung
Windows
Material: PVC
Product Dimensions: See Installation Instructions, SWD049
Prepared for:
Silvrer Line Windows and Doors
One Sliverline Dr.
North Brunswick, NJ 08902
Prepared by:
Hermes F. Norero, P.E.
Florida Professional Engineer # 73778
Date:10/14/2020
Contents:
Evaluation Report Pages 1— 3
Digitally signed by Hermes F Norero
Reason: I am approving this document
Date: 2020.10.22 02:29:06 +02'00'
Hermes F. Norero, P.E.
Florida P.E. No. 73778
µ BUILDING DROPS
A Perfect Solution In Every Drop!
Certificate of Authorization: 29578
Manufacturer Silver Line Windows and Doors
Product Category: Windows
Product Sub -Category: Single Hung
FL#: FL14911
Date: 10/14/20
Report No: 7262
Compliance Method: State Product Approval Method (1)(d)
Product Name: 70 Series / V1 Series / (2127) Single -Hung Windows
(HVHZ)(NON-IMPACT)
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line
Windows and Doors based on Method id of the State of Florida Product Approval, Florida
Department of Business and Professional Regulation - Florida Building Commission.
Limits of Use:
Hermes F. Norero, P.E. does not have nor will -acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the Current Florida Building
Code.
See Installation Instructions SWD049, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for
specific use parameters.
1. This product has been evaluated and is in compliance with the Current Florida Building Code,
includine the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Chapter 16 of the Current Florida Building Code and does require an impact resistant
covering.
4. Site conditions that deviate from the details of Installation Instructions SWD049 require
further engineering analysis by a licensed engineer or registered architect.
S. See Installation Instructions SWD049 for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida P.E. No. 73778
Page 2 of 3
BUILDING DROPS
A Perfect Solution in Every Dropl
Certificate of Authorization: 29578
FL#. FL14911
Date: 10/14/20
Report No: 7262
QualityAssurance Entity. The manufacturer has, demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a Quality Assurance Entity through
Window and Door Manufacturers Association (FBC Organization #QUA2515).
Performance Standards: The product described herein has been evaluated per:
Referenced Data:
Installation:
• TAS 202-94
• ASTM E330-02
• AAMA/WDMAJCSA 101/I.S.2/A440-08/11
1. Product Testing performed by Testing Evaluation Laboratories, Inc.
(FBC Organization # TST4317)
Report: Dated:
TEL01410311 12/15/2010
Signed and Sealed by: Lyndon F. Schmidt, FL P.E. No 43409,
Report: Dated:
G6367.01-109-47 12/19/2016
2. Quality Assurance
Window and Door Manufacturers Association
(FBC Organization #: QUA2515)
3. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance
with AAMA 303
Refer to Installation Instructions (SWD049) for anchor spacing and more details of the installation
requirements.
Design Pressure:
Refer to Installation Instructions (SWD049) for anchor spacing and more details of the installation
requirements.
Hermes F. Norero, P.E.
Florida P.E. No. 73778
Page 3 of 3
t O v i.�V Y Y R.i V Vt1.
I,�,u��,cTssc�IAIO
,ne
Hallmark®
Certificate of
•"
AIMS INC.
WDMAConformance
and License
(CCL) s�w,rn.
Silver Line Building Products
Mfr ID:
440
One Silver Line Drive
For more Information visit www.amscert.com
North Brunswick, NJ 08902
Website: https://www.andersenwindows.com/products/series/silver-line/
TEL:
800-234-4228 ext 4644
Product No. Product Name
Standard
Rating
Wide
High
Test Report #
CertDate
ExpDate
440-H-012.12
V1 Series Picture Window/2251-2351 IG
101/I.S.2/A440-11
Class R-PG60; Size Tested
965 mm
1346 mm
G8443.01-201-47
7/21/2017
3/2/2027
38.0 in x 53.0 in*; DP +60/-60
psf
440-H-012.18
V1 Series Picture Window/2251-2351
101/I.S.2/A440-11
Class R-PG60; Size Tested
1346 mm
1600 mm
G8442.01-201-47
7/21/2017
3/2/2027
53.0 x 63.0 in; DP +60/-60 psf
440-H-015.15
2200-2300/2251-2351 Picture Window
101/I.S.2/A440-11
Class R-PG50; Size Tested
2438mm
1372mm
G1001.01-109-47
8/22/2016
9/6/2026
2438mm x 1372mm (96 x 54)
Type-FW; DP +50/-50 psf
440-H-015.16
2200-2300/2253-2353 Triple Fixed Window
101/I.S.2/A440-11
Class R-PG20; Size Tested
2743mm
2134mm
G0999.01-109-47
9/6/2016
9/5/2026
2743mm x 2134mm (108 x 84)
Type-FW; DP +20/-20 psf;
Water Test Press 150Pa
(3.13psf)
440-H-015.17
V1-2200-2300/2251-2351 Picture Window
101/I.S.2/A440-11
Class CW-PG50; Size Tested
1524mm
1880mm
G1494.01-109-47
4/24/2017
12/20/2026
1524mm x 1880mm (60 x 74)
Type-FW; DP +50/-50 psf;
Water Test Press 360Pa
(7.52psf)
440-H-015.18
V1-2200-2300/2252-2352 Twin Picture Window
101/I.S.2/A440-11
Class R-PG25; Size Tested
2426mm
1880mm
G4541.01-109-47
4/24/2017
12/20/2026
2426mm x 1880mm (96 x 74)
Type-FW; DP +25/-25 psf;
Water Test Press 290Pa
(6.06psf)
440-H-015.19
V1 Series Picture Window - Twin (2252)
101/I.S.2/A440-11
Class R-PG35; Size Tested
1816mm
1524mm
G4541.01-109-47
4/24/2017
12/20/2026
72.0 in x 60.0 in; DP +40/40
psf
440-H-015.22
V1 Series Fixed Window - Triple (2253)
101/I.S.2/A440-11
Class R-PG35; Size Tested
2743 mm
1219 mm
D8518.03-109-47
4/10/2018
6/2/2024
108.0 in x 48.0 in; DP +50/-50
psf
440-H-016.06
V1 Series Picture Window - Twin (2252)
101/I.S.2/A440-11
Class R-PG15; Size Tested
2171 mm
2133 mm
H1571.01-201-47
1/5/2018
6/24/2027
2171 mm x 2133mm (85.5in x
84.01n); DP +15/-15psf
ND-20 5/26/2016 JGK Wednesday, December 2, 2020 Page 1
�. +
�. + ifl F� i # S IA'NON
Hallmark@ Certificate of
' �.
AMs, INC,
WDMA(
),$�,
Conformance and License CCL+
Silver Line Building Products Mfr ID: 440
One Silver Line Drive For more Information visit www.amscert.com
North Brunswick, NJ 08902 Website: https://www.andersenwindows.com/products/series/silver-line/
TEL: 800-234-4228 ext 4644
Product No. Product Name Standard Rating Wide High Test Report # CertDate ExpDate
WDMA and AMS HEREBY CERTIFY that the aforesaid Company ("Licensee"),
at its participating manufacturing plant(s), is licensed to use the WDMA
Registered Hallmark on product lines that have been manufactured in
accordance with the indicated standards. It is further certified that the plant(s),
facilities, quality control procedures, methods, and processes of Licensee have
been inspected, and are subject to regular follow-up inspection and test. It is
further certified that samples of the product set forth above were tested and
found to comply with the standards.
By.
By:
John McFee, VP of Certification Prog7wm WDMAa. m ,
Program Sponsor:
Window and Door Manufacturers Assoc
330 N. Wabash Avenue, Suite 2000
Chicago, IL 60611
TEL (312)673-4828 www.wdma.com
Program Administrator:
Administrative Management Systems, Inc.
PO Box 730, 205 West Main
Sackets Harbor, NY 13685
TEL (315)646-2234 staff@amscert.com
AID-20 5/26/2016 JGK Wednesday, December 2, 2020 Page 2
mil! `dZ(d
AMERICAN CRAFTSMAN WINDOWS
SILVER LINE WINDOWS AND DOORS,
GENERAL NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND
MANUFACTURED TO COMPLY WITH THE CURRENT EDITION
FLORIDA BUILDING CODE (FBC1, INCLUDING HVHZ AND HAS
BEEN EVALUATED ACCORDING TO THE FOLLOWING:
• TAS 202-94
• ASTM E330-02
AAMA/WDMA/CSA 101A.S.2/A440.OB/11
2. ADEQUACY OF THE EXISTING STRUCTURAL
CONCRETIE/MASONRY, 2X FRAMING, AND METAL FRAMING
AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF
WITHSTANDING AND TRANSFERRING APPLIED PRODUCT
LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE
ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF
INSTALLATION.
3. 1X AND ZX BUCKS (WHEN USED1 SHALL BE DESIGNED AND
ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE
STRUCTURE BUCK DESIGN AND INSTALLATION IS THE
RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF
RECORD FOR THE PROJECT OF INSTALLATION.
4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE
GENERIC AND MAY NOT REPLECT,ACFUAL CONDITIONS FOR
A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION
TO DEVIATE FROM THE REQUIRE14ENTS DETAILED HEREIN,
A LICENSED ENGINEERQR ARCHITECTSHALL PREPARE SITE
SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN
NON-HVHZ AREAS. IN HVHZ AREAS, ONE TIME PRODUCT
APPROVAL TO BE OBTAINED FROM MIAMI-DADE FIER OR
AHJ.
S. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON
THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE
6. WINDOW FRAME MATERLAL• PVC
7. IN ACCORDANCE WITH THE CURRENT EDITION FBC, WOOD
COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED
OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN
CHAPTER 23.
B. GLASS SHALL MEETTHE REQUIREMENTS OF ASTM E 1300
11 GLASS CHARTS. SEE SHEET i FOR GLAZING DETAILS.
70 SERIES / V1 SERIES / (2127)
SINGLE HUNG WINDOWS
(HVHZ)(NON—IMPACT)
MAX OVERALL SIZE
CONFIG.
DESIGN
PRESSURE
'
MISSILE
IMPACTRATING
WIDTH
HEIGHT
52"
6250"
O/X
+62.B/-65PSF
NONIMPACT
sr73"
O/X
+SS/-60PSF
NON IMPACT
TABLE OF CONTENTS
SHEET
REVISION
SHEET DESCRIPTION
1
-
GENERAL NOTES & GLAZING DETAIL
2
-
ELEVATION & ANCHOR LAYOUTS
3
-
VERTICAL SECTIONS
4
HORIZONTALSECTIONS
5
INSTALLATION NOTES & REINFORCEMENT DETAILS
IIERICAN CRAFTSMAN WINDOV
.VER LINE WINDOWS AND DOQ
ONE SILVER LINE DRIVE
NORTH BRUNSWICK, NJ 0890Z
PH: (888)741.0354
�
z
N3 F
0yY
10,
�Za
N C72
"'
�a
�_�
z
CD
Z 3 0
o
>
>�
N
m
�
Q alW
a
REMARKS
BY
DATE
7TH FBC EDITION
NLIS
M/14/N
n: I ep Oft dowmen
5/8" O.A. I.G. GLASS
Z
EXTERIOR / INTERIOR
OF Ir
nn
MELS12ACER
MIN. GLASS
1/8" OR 3/32" BITE 7/16"
30 a 0A1°" 01,' ®� y°
� RTM
SETTING -BLOCK
rape GF ft MM
FL #:
FL14911
GLAZING DETAIL
DATE: 01.23.18
DWG. BY:
CHK. BY:
NOTE:
HR
HFN
SCALE: NTS
ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH
SAFETY GLAZING REQUIREMENTS OUTLINED IN
CURRENT FBC AND ASTM E 1300 GLASS LOAD
DWG. #: SW D049
RESISTANCE.
SHEET:
FEB 2 2021
ST. Lucie County, Permitting
MAX.
MAX. 0.A FRAME
HEIGHT73'
D
MAX. D.L.O. 4
HEIGHT133.50"
MAX. CIA FRAME
WIDTH 52"
MAX. D.L.O.
WIDTH 47.69"
3 3
NY
"X"
ELEVATION
SINGLE HUNG WINDOW
3" MAX.
FROM
CORNERS
6" MAX.
O.C.
3" MAX.
FROM
CbRNERS�
ANCHOR LAYOUT
NAIL FIN -SINGLE HUNG WINDOW
6" MAX. 6.25" MAX.
O.C.FROM Fes —
CORNERS I
NOTE:
ALL FASTENERS ABOVE
THE MEETING RAIL IN
THE INTERIORJAMB
TRACK MUST BE FLATHEADS.
12.50" MAX.
O.C.
6.25" MAX.
FROM
CUNERS L
t
ANCHOR LAYOUT
THROUGH FRAME -SINGLE HUNG WINDOW
AMERICAN CRAFTSMAN WINDOW
SILVER LINE WINDOWS AND DOOP
ONE SILVER LINE DRIVE
NORTH BRUNSWICK, NJ 08902
PH: (888) 741=0354
nFn
Z�
N-
W Z C N
wz
a¢ $$
cc �a
x
dg
p
Tc�
W
oz�
>°°
m
Vl
t
r
"a'
n
off �v Q_'
S A QF:
I 3" E BANA BEACH W 333 I
DAM BEAM FL
WE UK BE AB711pIwrm ft ma7B
FL #;
FL14911
DATE: n1.7; 1 R
SCALE: NTS
DWG. tr: .W nnaai
I
W
EXTERIOR
i
SEE GLAZING
DETAIL, SHEET 1
INTERIOR
_ SEE GLAZING
DETAIL, SHEET 1
VERTICAL SECTION
' NAIL FIN
SEE GLAZING ,
DETAIL, SHEET 1
INTERIOR
_ SEE GLAZING
DETAII,'SHEET 1
B� VERTICAL SECTION
3 THRU FRAME
VIERICAN CRAFTSMAN WINDOI
VER LINE WINDOWS AND DOa
ONE SILVER LINE DRIVE
NORTH BRUNSWICK, N108902
PH: (888) 741-MS4
VI
No
?GWm
tWiI ID ZZ
=Z
SN
W >
F
;
0'
_ W
R
V
VI Z
�
m
W
~
W
a
FBC
V
I $ AM OF IF a-
ue U ti W 3M
nw -W. W NDNOOLIIIW N. 211
FL N:
FL14911
DATE: ni 7Z 1'Q
SCALE: .
DWG. #:
I
SECTION FOR
BLOCK &TACKLE
BALANCERS
INTERIOR
GLAZING
SECTIOiN FOR
SEE GLAZING f-C ONSTANT FORCE
DETAIL SHEET 1 BALANCERS
EXTERIOR
r D.L.O.
MAX. FRAME WIDTH
C HORIZONTAL SECTION_
4 UPPERSASH
SEE GLAZING INTERIOR SEE GLAZING
DETAIL SHEET 1 DETAIL SHEET 1
i7! \
EXTERIOR
- D.L.O.
MAX. FRAME WIDTH
p HORIZONTAL SECTION
4 LOWER SASH
IIERICAN CRAFTSMAN WIND01
VER LINE WINDOWS AND DOC
ONE SILVER LINE DRIVE
NORTH BRUNSWICK, NJ 0899E
PH: (888) 741-0354
you
Z
� 3 CL
E
cc
VI l7Z
rI Z 0
¢
6
Ul
g3
a
�
N
C)
_
1 >
-O
Nj
1
oz=
=
smm
r '
m
o -0
a
F
n
REMARKS
BY DATE.
7TH FBC EDITION
mammna!„
a SIAX pF ;
L R =
ago
RPE CM 6 MI7XCPo7A77CH N. ]A77E
FL #:
FL14911
DATE: 01-23-1 R
SCALE:
DWG. #:
SHEET:
4
MIN. -SUBSTRATE
EDGE DISTANCE / BY OTHERS
j MIN.
EMBEDMENT
PERIMETER SEALANT —� 1/4" MAX.
I OTHERS SHIM SPACE .
EXTERIOR N INTERIOR
5 VERTICAL SECTION
THROUGH FRAME (HEAD)
1/4" MAX.
SHIM SPACE I-- SUBSTRATE
-
MIN. EMBEDMENT
INTERIOR BY OTHERS
SUBSTRATE
SCREW IN THE INTERIOR
BY OTHERS
_ CHANNEL
MIN.
EDGE DISTANCE
SCREW IN THE EXTERIOR
W W
to "
CHANNEL
z
PERIMETER SEALANT
BY OTHERS
EXTERIOR MIN.
1/4" MAX.
SHIM SPACE
EMBEDMENT-
EXTERIOR
INTERIOR .
Q HORIZONTAL SECTION
rt'�
HORIZONTAL SECTION
5 THROUGH FRAME (JAMB)
NAILFIN(HEAD)
SUBSTRAT
�+- 1/4' MAX.
BY OTHERS
I SHIM SPACE
INTERIOR
83°
w
m
EXTERIOR
0.77"�� D 9„
W T
t
1
INTERIOR
°LTEwC
%, LOCK RAIL TOP O
MIN. EDGE
v ALUMINUM
DISTANCE
5 HORIZONTAL SECTION JE`\ VERTICAL SECTION
NAIL FIN (JAMB) S MEETING STILE
INSTALLATION NOTES:
I. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN.
2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OF..THE
MAXIMUM SIZE LISTED.
3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF 31/2 INCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR LAYOUT
DETAILS (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT.
4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 3/81NCH. SHIM
WHERE SPACE OF 1/16'INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.
5. FOR MASONRY OR 06NCRETE OPENINGS, 1X WOOD BUCK MAY BE USED (OPTIONAL AS LONG AS THE MINIMUM EMBEDMENT AND EDGE
DISTANCE REQUIREMENTS ARE STILL METWITHIN THE CORRESPONDING
INFORMATION. ION. HOSTSUBSIAATE. SEE GENERAL NOTE #3 ON SHEET.1 FOR MORE
6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND
SIDING.
7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT
COATING.
S. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED
FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK.
9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS
SHALL NOT BE USED IIN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER.
10. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK, USE FLAT HEAD ANCHORS.
REINFORCEMENT DETAILS
�0.87°
0.34"
j--0.13"
�- �
T 0.06" 1 -:i f - 0.46°
0.45" 0.87"
LOCK MEETING RAIL 3 BOTTOM LIFT RAIL & SASH
ALUMINUM O ALUMINUM
ILVER LINE WINDOWS AND D001
ONE SILVER LINE DRIVE ,
NORTH BRUNSWICK, NI08902
PH: (888) 741-03S4
'oE
Z#
o
ce
Wag0
cc
Zig
Mz F�
W
W
�
a
W
F
d I
FBC
lOat
S A OF D^
�0 E I
MIE af. of �m N.
FL #:
FL14911
DATE: (11 55 1 4
SCALE
DWG. #:
I