Loading...
HomeMy WebLinkAboutCompaction TestHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:210964-1d/SH/ct PERMIT #:NUC #276 CONTRACTOR:Trefelner Construction Nuc Model:MC-DR JOB LOCATION:5040 Southwind Trail Nuc Serial #:MD40107276 Ft. Pierce, Florida ITEM TESTED:Stemwall Footers TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.W.0" - 12"38 106.9 109.2 97.9% 2. N.E."38 107.1 "98.1% 3. Center "40 108.0 "98.9% 4. S.E."39 107.6 "98.5% 5. S.W."38 106.8 "97.8% Soil Description: Gray Sand In Place Moisture: 8.3% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 109.2 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Staked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 2/5/2021 Email to: TrefelnerJ@bellsouth.net SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 February 4, 2021 2011-0344 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Proudly Serving Florida since 1990 106.0 107.0 108.0 109.0 110.0 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight