Loading...
HomeMy WebLinkAboutCompaction TestHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:204330-2d/CH/ct PERMIT #:NUC #417 CONTRACTOR:Grande Construction Nuc Model:3500 JOB LOCATION:465 SE Verada Avenue Nuc Serial #:3417 Port St Lucie, Florida ITEM TESTED:Compacted Foundation Fill - 1st & 2nd Lift TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.W.12" - 24"45+109.2 110.5 98.8% 2. N.E.""109.0 "98.6% 3. Center 24" - 36""108.9 "98.6% 4. S.E.""109.3 "98.9% Soil Description: Brown Sand In Place Moisture: 9.0% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 110.5 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 2/5/2021 Email to: greg@grandefl.com SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 February 4, 2021 2012-0552 Proudly Serving Florida since 1990 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. 107.0 108.0 109.0 110.0 111.0 112.0 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight