HomeMy WebLinkAboutEngineering 806 Delaware Ave. (772) 267-1399
Fort Pierce, FL 34950 benchmarkengineeringtc@gmail.com
December 28, 2020
Re: Single Family Residence
5417 Cassia Dr
Fort Pierce, FL
Permit#2005-0468
To Whom It May Concern:
Please be advised of the revisions to the above referenced project as follows:
1) 'Revise window and door bucks to allow for 5/8"continuous plywood or(2 layers)
of 1/4" continuous plywood to be applied to top of buck(same width), in lieu of
buck size as indicated on plans. Bucks shall cover entire width of jambs.
2) Window and door attachment shall allow for longer tapcons so that the attachment
ensures minimum embedment length as per product approval.
Thank you for your attention to this matter.
IIIIIl1I111111f//
Su O� cykv`j:C,,,,,;
=m �0 70878 0'
i*o � S1,
BowdoI 'Q"IiIU't'chinson
Reg.No 70878