Loading...
HomeMy WebLinkAboutHealth Dept Inspection ReportSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Jimmy Hardison AGENT: Brian Davis (Brian Davis Septic) PROPERTY ADDRESS: 12445 Lear PI Port Saint Lucie, FL 34987 LOT BLOCK: APPLICATION #:AP1465606 PERMIT #:56-SF-2035849 DOCUMENT #: F11567988 DATE PAID:02/04/2020 FEE PAID:430.00 RECEIPT #:56-PID-4286771 SUBDIVISION: Treasure Coast Air Park ID#: 4224-501-0086-000-4 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION [ ] (01] TANK SIZE [11 1090.00 [2] 483.00 [ ] [021 TANK MATERIAL Polypropylene [ ] [031 OUTLET DEVICE [ ] [041 MULTI -CHAMBERED LLZJ N ] [ ] [05] OUTLET FILTER Polylok PL-68 [ ] [06] LEGEND 1. 70-143-11SC4 2. 70-143-54SC4 [ ] [07] WATERTIGHT [ ] [081 LEVEL [ ] [09] DEPTH TO LID DRAINFIELD INSTALLATION [ ] [101 AREA [11 667.8 [21 SQFT [ ] [111 DISTRIBUTION BOX HEADER X [ ] [12] NUMBER OF DRAINLINES 1. 6.00 2. [ ] [131 DRAINLINE SEPARATION [ ] [141 DRAINLINE SLOPE [ ) 1151 DEPTH OF COVER [ ] [16) ELEVATION [ ABOVE / BELOW ]BM 23.00 [ ] [17] SYSTEM LOCATION [ ] [181 DOSING PUMPS [ ] (191 AGGREGATE SIZE [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [211 AGGREGATE DEPTH FILL / EXCAVATION MATERIAL [ ] [221 FILL AMOUNT [ ) [23] FILL TEXTURE [ ) [24] EXCAVATION DEPTH [ ] [25] AREA REPLACED [ ] [261 REPLACEMENT MATERIAL Comments: Comments are on page 2. SETBACKS [ ] [271 SURFACE WATER FT [ ] [281 DITCHES FT [ ] [291 PRIVATE WELLS 80 FT [ ] (30] PUBLIC WELLS FT [ ] [31] IRRIGATION WELLS FT [ ] [32] POTABLE WATER 67 FT [ ] [33] BUILDING FOUNDATIONS 7 FT [ ] [341 PROPERTY LINES 100 FT [ ] [351 OTHER FT FILLED / MOUND SYSTEM [ ] [361 DRAINFIELD COVER [ ] [371 SHOULDERS [ ] (38] SLOPES [ ] [39] STABILIZATION 02/03/2021 ADDITIONAL INFORMATION [ ] [40] UNOBSTRUCTED AREA [ ] [41] STORMWATER RUNOFF [ ] [421 ALARMS [ ] (431 MAINTENANCE AGREEMENT [ ] [441 BUILDING AREA [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [461 FINAL SITE GRADING [ ] [471 CONTRACTOR Brian Davis (Brian Davis Sept [ ] [481 OTHER INFILTRATOR Quick4 Plus EQ36 LP ABANDONMENT [ ] [49] TANK PUMPED [ ] [501 TANK CRUSHED & FILLED CONSTRUCTION [ APPROVED / St. Lucie CHD DISAPPROVED ] ' Environ ntal Specialist II i Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: i St. Lucie CHD Environmental Specialist rian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1465606 EID2035849 DATE: 11 /16/2020 DATE: 02/03/2021 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION # : AP 1465606 PERMIT #:56-SF-2035849 DOCUMENT #:F11567988 DATE PAID:02/04/2020 FEE PAID:430.00 RECEIPT #:56-PID-4286771 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. System inspected by Jamie Sabins FDOH Okeechobee County. New 1090 and 483 STs in series with new filter and 5x10+1x9 long BED DF installed. No violations. System ok to cover. Contractor notified by email. Needs final inspection for mound system and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1465606 EID2035849