Loading...
HomeMy WebLinkAboutProduct Approvals Business & Professional Regulation 8Q5 Home top In User Registration Hot Topics Submit Surcharge Stats 8 Facts Publications Contact Us SCIS site Map Unks Search b? r Product Approval RECEIVED p USER:Public User JAN 2 1 2021 Product ADOrOVai Menu>Product or Application Search>Agollcanon ust>Application Detail Permitting DEpartment FL# FL7849-R13 St. Lucie Ccunty Application Type Revision Code Version 2020 Application Status Approved e �® *Approved by DBPR.Approvals by DBPR she l e reviewed a tifled by the POC and/or the Commission if necessary. Comments fE ' �0�YY� Archived Y I E EDL FF V F Product Manufacturer Boral Roofing CODE COMPLIANCE Address/Phone/Email 7575 Irvine Center Drive STa VCIE COUNTY Suite BOCC l f?l C/1 Irvine,,C CA 92618 (801)380-6091 RobinAnderson@boral.com Authonzed Signature Anderson Robin Robi nAnderson @boral.com Technical Representative Robin Anderson Address/Phone/Email 10701 So. River Front Parkway Suite 300 So.Jordan, UT 84095 (801)380-6091 robinanderson@boral.com Quality Assurance Representative Robin Anderson Address/Phone/Email 7575 Irvine Center Dr. #100 Irvine, CA 92618 (801) 380-6091 robinanderson@boral.com Category Roofing Subcategory Roofing Tiles Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity IAPMO Uniform Evaluation Services LLC. Quality Assurance Entity QAI Laboratories Quality Assurance Contract Expiration Date 12/31/2025 Validated By Gary W. Walker Validation Checklist- Hardcopy Received Certificate of Independence FL7849 R13 COI iAPMO -niforn ES-Certificate of Independence.odf Referenced Standard and Year(of Standard) Standard Year ASTM C1492 2009 ASTM E108 2016 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option C Date Submitted 11/09/2020 Date Validated 11/10/2020 Date Pending FBC Approval Date Approved 11/18/2020 Summary of Products Go to Page ® 0 0 Page 2/2 0 0 FL all Model,Number or Name Description 7849.21 Saxony 900 Flat Profile-Okeechobee,FL Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installation.pdf Approved for use outside HVHZ: Yes FL7849 R13 II Florida Hi Wind—ile Installation Manual- Impact Resistant. N/A 6th Edition.pdf Design Pressure: N/A ( Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports j FL7849 R13 AE UES ER-412.12df 7849.22 Saxony 900- Hartford Slate,Shake, I Flat Profile-Stockton,CA Slate,Country Slate&Split Old English Thatch I Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Instalition.pdf Approved for use outside HVHZ: Yes FL7849 R13 I: Flonda High Wind_-ile Installation Manual- Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: Gary W. Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pdf 7849.23 Saxony 900-Shake&Slate Flat Profile-Lathrop,CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion.odf Approved for use outside HVHZ: Yes FL7849 R13 II Florda High Wind Tile Installation Manual- Impact Resistant: N'A 6th Edition.odf Design Pressure: N,A Verified By: Gary W.Walker 40455 Other: Created by Independent Third Party:Yes Evaluation Reports FL7849 R13 AE UES ER-412.g� 7849.24 Saxony 900-Shake,Slate&Country Flat Profile-Henderson, NV Slate Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-InstallCion.Ddf Approved for use outside HVHZ: Yes FL7849 R13 II Florida Hi Wind Tile Installation Manual- Impact Resistant: N/A 6th Edition.0 Design Pressure: N/A Verified By: Gary W.Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE I ES ER-412.pdf 7849.25 Saxony 900-Shake,Slate,Split Flat Profile- Lake Wales, FL Shake&Country Slate Limits of Use Installation Instructions Approved for use in HVHZ:No FL7849 R13 I1 EBS-Instalition.odf Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual- Impact Resistant: Ni A 6th Edition.odf Design Pressure: NiA Verified By: Gary W.Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.gd 7849.26 Saxony 900-Slate,Shake&Country Flat Profile-Rialto,CA — Shake Limits of Use I Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion.pdf Approved for use outside HVHZ:Yes FL7849 R13 II Florida High Wind Tile Installation Manual- it Impact Resistant: N/A 16th Edition.W Design Pressure: N/A Verified By: Gary W.Walker 40455 Other: I Created by Independent Third Party:Yes Evaluation Reports FL7849 R13 AE UES ER-412.Qdf 7849.2-, Telas Espana/Barcelona Hlgh Profile-Katy,TX Limits of Use Installation Instructions Approved for use in HVHZ: No I FL7849 R13 II EBS-Installation.odf Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual- Impact Resistant: ^J 16th Edition.odf Design Pressure: -a , Verified By: IAPMO Uniform Evaluation Services LLC. Other: I Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.pdf 7849.26 %il a -- Low Profile-Katy,TX — Limits of Use Installation Instructions Approved for use in HVHZ: Nu FL7849 R13 II EBS-Installation.{ Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual- Impact Resistant: `d 6th Edition.odf Design Pressure: Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.Ddf 7849.29 / _ Low Profile-Phoenix,AZ Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installation.odf Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual- Impact Resistant: Pi;.A ;6th Edition.odf Design Pressure: Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.odf 7849.30 Villa 600&900 Low Profile-Rialto,CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion.odf Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual- Impact Resistant: N/A 6th Edition.pdf Design Pressure: N/A Verified By: Gary W.Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pdf 7849.31 Villa 600&900 Low Profile-Stockton,CA Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installtion.odf Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual- Impact Resistant: N A (6th Edition.odf Design Pressure: Verified By: Gary W.Walker 40455 Other: i Created by Independent Third Party: Yes Evaluation Reports FL7849 R13 AE UES ER-412.pd 7849.32 Villa 900 Low Profile-Lake Wales,FL Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Instal lti on,pQ Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual- Impact Resistant: N/A 16th Edition.odf Design Pressure: N/A Verlfied By: Gary W.Walker 40455 Other: Created by Independent Third Party: Yes Evaluation Report FL7849 R13 AE UES ER-412.12df 7849.33 Villa 900 Low Profile-Stockton,CA Limits of Use Installation Instructions Approved for use in HVHZ:No FL7849 R13 II EBS-Installation.odf Approved for use outside HVHZ:Yes FL7849 R13 I: Florida High Wind Tile Installation Manual- Impact Resistant: N t 6th Edition.odf Design Pressure: % A Verified By: ICC Evaluation Service, LLC Other: Created by Independent Third Party: Evaluation Report FL7849 R13 AE UES ER-4:2.pdf 7849.34 Low Profile-Denver,CO Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installation odf Approved for use outside HVHZ: Yes FL7849 R13 II Florida High Wind Tile Installation Manual- Impact Resistant: N/A i 6th Edition.= Design Pressure: WA Verified By: IAPMO Uniform Evaluation Services LLC. Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.odf 7849.3S j Villa Impact Low Profile-Denver,CO Limits of Use Installation Instructions Approved for use in HVHZ: No FL7849 R13 II EBS-Installation.pdf Approved for use outside HVHZ: Yes FL7849 R13 II Flor'da High Wind Tile Installation Manual- Impact Resistant: N 6th Edition.odf i Design Pressure: Verified By: IAPMO Uniform Evaluation Services LLC. 1 Other: Created by Independent Third Party: Evaluation Reports FL7849 R13 AE UES ER-412.pd Go to Page 0 0 Page 2/2 0 Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida:s an WEED employer.Coovright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.Y you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mad.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1), Florida statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address H they have one.The emads provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made avadaole to the public.To determine if you are a licensee under Chapter 455,F,S.,please dick hers-. Product Approval Accepts: �® ALFT_;_�j0 Credit Card Safe VE • - 412 Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07/31/2021 BORAL ROOFING 3.0 PRODUCT USE 7575 Irvine Center Drive,Suite 100 Irvine,California 92618 3.1 General: Boral Roofing Concrete Roof Tiles shall be (949)756-1605 used as a roof covering in accordance with IBC Section www.boralamerica.com 1503 or IRC Section 903.as applicable. CONCRETE ROOF TILES 3.2 Installation: CST Section: 3.2.1 Installation when installed in accordance with the 07 3216 Concrete Roof Tiles requirements of the 2018 IBC or IRC: Boral Concrete Roof Tile shall be installed in accordance with 2018 IBC 1.0 RECOGNITION Section 1507.3 or 2018 IRC Section R905.3, including the Boral Roofing Concrete Roof Tiles recognized in this report attachment requirements of 2018 IBC Section 1507.3.7 or have been evaluated for use as concrete roof tiles. The 2018 IRC Section R905.3.7,as applicable. Underlayment weather resistance, wind uplift resistance and fire shall conform to 2018 IBC Section 1507.1.1 or 2018 IRC classification properties of the roof tiles comply with the Section R905.1.1 intent of the provisions of the following codes and regulations: 3.2.2 Installation when the 2015,2012,2009 or 2006 IBC or IRC is applicable: Boral Concrete Roof Tile shall be • 2018, 2015, 2012, 2009, and 2006 International fastened in accordance with The Concrete and Clay Roof Building Codes(IBC) Tile Installation Manual for Moderate Climate Regions, dated 1u1 2015 published b the Tile Roofs Institute and 2018, 2015, 2012, 2009, and 2006 International Y .P Y g Residential Code®(IRC) the Western States Roofing Contractors Association, and • 2019 California Building Code(CBC)—Supplement this report.. The TRI manual is available for download attached attached to ER-2015 from the UES website at • 2019 California Residential Code (CRC) — www.uniform-es.ore. The Concrete Roof Tile shall be Supplement attached attached to the roof structure based on the applicable code • 2020 Florida Building Code, Building (FBC, and criteria for applicability as noted in Table 1 of this Building)—Supplement attached report. • 2020 Florida Building Code, Residential (FBC, TABLE I—ATTACHMENT DESIGN Residential)—Supplement attached Design Applicable Criteria for Applicability Informati Location 2.0 LIMITATIONS Code Ultimate Design Wind 2015 or 2012 Speeds(Va„)5 130 MPH Roof Tile Use of the Boral Roofing Concrete Roof Tiles recognized in IBC and Mean Roof Height<_60 Installation this report is subject to the following limitations: feet Manual do Table 2009 or 2006 Basic Wind Speed(3 sec 1507.3.7 of the 2.1 The roof tiles shall be manufactured, identified and IBC gust)<100 mph and Mean applicable IBC installed in accordance with this report and the applicable Roof Hei t s 60 feet 2015,2012, Roof Tile code.In the event of a conflict this report governs. Mean Roof Hci lit<_40 feet installation 2009 or 2006 g Manual&Section 2.2 Boral Roofing"concrete roof tile shall be installed on IRC R905.3.7 roof slopes of 2 t/2 units vertical in 12 units horizontal(21- For SI:I foot=305 min,I mph=1.6 tn's percent slope)or greater."IBC Section 1507.3.2. 3.4 Anchoring: Boral Concrete Roof tile may be anchored 23 The supporting structure shall be designed to support the by mortar in accordance with the applicable building code loads and is beyond the scope of this report. and,where permitted,the TRI Manual or adhesively attached in accordance with the adhesive manufacturer's research 2.4 The Concrete Roof Tiles recognized in this report are report issued by an approved evaluation service agency. produced in Lake Wales,FL;Brookshire,TX;Phoenix,AZ; Henderson, NV; Okeechobee, FL, Rialto, CA; French Camp, CA; Henderson, CO and Lathrop, CA; Tables 2 A through 2 I describe the tiles produced at each location. The product described do this Uniform Evaluation Service(UES)Report has been evaluatod as an altemabve material,design or method of construction m order to satisfy and comply with the intent of the provision of the code,as noted in this report,and for at least equvalence to that prescribed in the code in quality.strength.effectiveness.fire resistance.durabAty and safety,as applicable.in accordance with IBC Section 104 11 This docanent shall only be reproduced in its entirety t Copyright C 2020 by international Association of Plumbing and Mechanical Officials.All rights reserved Printed in the United States, Phi 1-877-41ESRPT•Fax 909.472.4171 web:www.0 rlorm-es.org•4755 East Philadelphia Street,Ontario,Cakfomia 91761-2616-USA �e•1w Page 1 of 7 " �E8EVALUATION REPORT Number: 12 Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07/31/2021 4.0 PRODUCT DESCRIPTION 7.0 STATEMENT OF RECOGNITION Boral Roofing Concrete Roof Tiles comply with ASTM This evaluation report describes the results of research C1492 as required by Section 1507.3.5 of the IBC.The roof carried out by IAPMO Uniform Evaluation Service on Floral tiles are described by model, weight, dimensions, and tile Roofing Concrete Roof Tiles to assess conformance to the factor in Tables 2 A through 2 1, for each of the production codes shown in Section 1.0 of this report and serves as locations listed in Section 2.4 of this report. When installed documentation of the product certification. Products are in accordance with this report on minimum 15/32 inch thick manufactured at locations noted in Section 2.4 of this report (12 mm)plywood solid sheathing or non-combustible decks, under a quality control program with periodic inspection the assembly incorporating the roof tiles achieve an ASTM under the supervision of IAPMO UES. E 108 Class A rating per Section 1505.2 of the IBC and Section R902.1 of the 1RC, as applicable. Roof classifications for adhesively attached systems shall be in accordance with the adhesive manufacturer's approved research report. 5.0 IDENTIFICATION Brian Gerber,P.E.,S.E. Vice President,Technical Operations Shipping pallets are identified with the report holder's Uniform Evaluation Service name (Boral Roofing), manufacturing address, product name, installed weight, inspection agency, and evaluation ' }t� report number(ER412). The Cedarlite 600, Madera 700 Richard Beck,PE,CBO,MCP and Madera 900 tiles are imprinted on the top side of each Vice President,Uniform Evaluation Service tile with an"M",all other filed tiles are imprinted with the name "Boral", 'Boral Lifetile", "Monierlifetile", or the Boral Roofing,or MonierLifetile or"Vostile"or logo.The GP Russ Chaniy identification includes the IAPMO Uniform Evaluation CEO,The IAPMO Group Service Mark of Conformity. Either Mark of Conformity For additional information about this evaluation report please visit may be used as shown below: NNw.uniform-cs.or_or email us at info auniform-es.ore �ApMO or UES ES IAPMO UES ER412 6.0 SUBSTANTIATING DATA Data in accordance with ICC-ES AC 180, dated February 2012 (editorially revised March 2018), manufacturer's descriptive literature and installation instructions. Test reports are from laboratories in compliance with ISO/IEC 17025. Page 2 of 7 UE8EVALUATION REPORT Number: 412 " Originally Issued: 07/31/2015 Revised: 0812112020 Valid Through: 07/31/2021 Table 2 A-Tiles Manufactured at Denver(Henderson),CO Ditnemsions2 Tile Factor Installed Dry inch W 1 ) Tile eight (psf) Length X Width TF(RI) Ratio Saxony-Shake,Slate,Country Slate Split Old English Thatch 9.6 17 X 13 1.568 I.l 15 on ' Impact 10.5 17 X 13 1 1.568 1.115 9.0 17 X 13 1.503 1.068 V a- act 10.1 17 X 13 1.503 1.068 For SI: I inch=25.4 nun.1 psf=4.88 kglm2 Table 2 B-Tiles Manufactured at Henderson,NV Installed D Ditnemsions2 Dry Tile Factor Tile Weight' inch (psf) Length X Width TF(ft`) Ratio' Es afia r Barcelona 9.0 17 X I23'8 1.470 1.045 Saxony 900-Shake,Slate, 9.1 17 X 13 1.533 1.090 Country Slate For SL I inch=25.4 mm.I psf=4.88 kgW Table 2 C-Tiles Manufactured at Katy(Brookshire),TX Installed D Dimemsions2 n' Tile Factor Tile Weight' inch (psf) Length X Width TF(ft') Ratio ' Barcelona-Impact 10.3 16'/z X 13 1.444 1.027 Saxony-Country Shake,Country Slate,Country Split Shake,English 10.3 16%:X 13 1.392 0.989 Thatch Saxony-Impact 10.5 16'h X 13 1.392 0.989 Saxony-Shake,Slate 10.3 16'/2 X 13 1.392 0.989 Teas Es afia, Barcelona 9.0 16'/2 X 13 1 A07 1.000 Villa 9.0 16'/z X 13 1.407 For SL• I inch-25.4 mm,t psf=4.88 kg-m= NOTES TO TABLES: I. Used on a 3-inch head-lap. 2. Nominal dimension. Page 3 of 7 DESEVALUATION REPORT Number: 12 Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07/31/2021 Table 2 D-Tiles:Manufactured at Lake Wales,FL Installed Dry DimemsionsZ Tile Factor Tile Weight' (inch) (psf) Length X Width TF(ft;) Ratio Barcelona 900 9.5 17 X 13 1.525 1.084 Saxony 900-Shake,Slate,Split 9.5 17 X 13 1.545 1.098 Shake.Country Slate Spanish"S"Nuevo 9.9 17 X 93/, 1.144 1 0.813 Villa 900 9.2 17 X 13 1.533 1.090 For SI: I inch=25.4 mm. I psf=4.88 kgim= Table 2 E-Tiles Manufactured at Lathrop.CA Installed Dry Dimemsions'- Tile Factor Tile Weight' (inch) (pst) Length X Width TF(ft') Ratio' Barcelona 900 9.3 17 X 13 1.509 1.073 Saxon 900-Shake,Slate 9.1 17 X 13 1.533 1.090 For SL 1 inch-25.4 ram.l psf-4.88 kg'mz Table 2 F-Tiles Manufactured at Phoenix,AZ Installed D DimemsionsZ �'� Tile Factor Tile Weight' inch) (psf) Length X Width TF(113) Ratio' Mission S Barcelona 10.3 161/2 X 13 1.494 1.062 Saxony-Shake.Slate 9.5 16%z X 13 1.494 1.062 Villa 9.0 16'hX 13 1.407 1.000 For SL I inch-25.4 nun. 1 psf-4.88 kg'm' Table 2 G-Tiles Manufactured at Okeechobee,FL Installed Dry I DimemsionsZ Tile Factor Tile Weight' inch (psi Length X Width TF(ft3) Ratio Bermuda 12.44 16'/8 X 10'/8 1.036 0.736 Estate"S" 7.9 161/2 X 13 1.417 1.007 Galena Spanish"S" 9.3 17 X 10 1.144 0.831 Plantation 10.4 16'/z X 13 1.426 1.014 Saxony 900 9.3 17 X 13 1.533 1.090 For SL I inch=25.4 mm. I psf=4.88 kg'mz NOTES TO TABLES: 1. Used on a 3-inch head-lap. 2. Nominal dimension. Page 4 of 7 gEVALUATION REPORT Number: 412 Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07/31/2021 Table 2 H-Tiles Manufactured at Rialto,CA Installed D DimemsionsZ tT � Tile Factor ( Tile Weights inch (psf) Length X Width TF(ft') Ratio Es aria Barcelona 9.0 17 X 123's 1.454 1.033 Espana 600/Barcelona 600 5.9 17 X 123i8 1.454 1.033 Saxony 600-Slate,Shake,Split 5.9 17 X 13 L533 1.090 Shake Saxony 700-Slate.Shake,Split 7.1 17 X 13 1.533 1.090 Shake Saxony 900-Slate.Shake,Country 9.3 17 X 13 1.533 1.090 Shake Villa 600 5.8 17 X 13 1.494 1.061 Villa 900 9.0 17 X 13 1.494 1.061 For Sl: I inch=25.4 mm, I psf=4.88 kg/m2 Table 2 1-Tiles Manufactured at Stockton(French Camp),CA Installed Dry DimemsionsZ Tile Factor Tile Weight' (inch) (psf) Length X Nidth TF(tt') Ratio' Cedarlite 600 5.9 13'/z X 13 0.942 0.673 Madera 700 7.2 131G X 13 0.947 0.673 Madera 900 9.5 131/2 X 13 0.947 0.673 Saxony 600-Slate.Shake.Split Shake 5.7 17 X 13 1.525 1.084 Saxonv 700-Slate,Shake,Split Shake 7.2 17 X 13 1.525 1.084 Saxonv 900-Hartford Slate.Shake. 9.1 17 X 13 1.533 1.090 Slate,Country Slate Saxon 900-Split Old English Thatch 9.8 17 X 13 1.525 1.084 Villa 600 6.0 17 X 13 1 494 1.115 Villa 900 1 9.3 1 17 X 13 1.494 1.115 For SI: I inch-25.4 mm.I psf=4.88 kg m` NOTES TO TABLES: I. Used on a 3-inch head-lap. 2. Nominal dimension. Page 5 of 7 �E8EvALUATION REPORT Number: 412 Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07/31/2021 CALIFORNIA SUPPLEMENT 2.4 Boral Roofing concrete roof tiles used on structures regulated by the Division of the State Architect or the Officc BORAL ROOFING of Statewide Planning and Development are subject to 7575 Irvine Center Drive,Suite 100 installation provisions in CBC Section 1513. Irvine,California 92618 For additional information about this evaluation report please visit (949) 756-1605 svisis.unifonn-rs.oru or email us at info a uniform-es.ore N'N Ns.boralaniericaxonl CONCRETE ROOF TILES CST Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION The Boral Concrete Roof Tiles evaluated in [APMO UES ER-412 is a satisfactory alternative to the following codes and regulations: • 2019 California Building Code(CBC) • 2019 California Residential Code(CRC) 2.0 PRODUCT USE 2.1 The Boral Roofing concrete roof tiles may be used as a Class A, B, or C roof covering systems complying with Sections 1505.1.1 of the CBC or R902.1.1 of the CRC; Sections 1505.1.2 of the CBC or R902.1.2 of the CRC; or Sections 1505.1.3 of the CBC or R902.1.3 of the CRC, respectively. The design and installation of the Boral Roofing concrete roof tiles shall be in accordance with Sections 1507.3.10 and 1513 CBC or Section 905.3 of the CRC,as applicable,and ER-412. 2.2 Roof Tiles shall be installed in accordance with Sections 3.0 and 4.0 of ER412 except, where the building official requires conformance to the CBC or CRC,the following shall be substituted: 2.2.1 Underlayment shall conform with CBC Section 1507.1.1 or CRC Section 905.1.1. 2.2.2 Attachment of the concrete roof tiles shall be designed to resist wind loads according to CBC Sections 1507.3.7 and 1609.5 or CRC Section 905.3.as applicable. 2.3 Boral Roofing concrete roof tiles may be used in"new buildings located in any Fire Hazard Severity Zone or any Wildland-Urban Interface Fire Area designated by the enforcing agency constructed after the application date shall comply with the provisions" in accordance with Sections 701A.3 and 705A of the CBC, or Sections R337.1.3.1 and R337.5 of the CRC, as applicable, and with the IBC as presented in ER412. Page 6 of 7 9EVALUATION REPORT Number: 412 ao Originally Issued: 07/31/2015 Revised: 08/21/2020 Valid Through: 07/31/2021 FLORIDA SUPPLEMENT loads shall be in accordance with Section 1609.5 of the FBC, Building or Section R301.2.1 of the FBC, Residential, as BORAL ROOFING applicable. 7575 Irvine Center Drive, Suite 100 Irvine,California 92618 For additional information about this esaluation report please kisit (949)756-1605 NNµ.umlorm- s.ore or email us at into o uniform-e..ore ww .boralamerica.com CONCRETE ROOF TILES CSI Section: 07 32 16 Concrete Roof Tiles 1.0 RECOGNITION The Boral Roofing concrete roof tiles evaluated in IAPMO UES ER-412 is a satisfactory alternative to the following codes and regulations: • 2020 Florida Building Code. Building (FBC, Building) • 2020 Florida Building Code. Residential (FBC, Residential) 2.0 LIMITATIONS 2.1 Verification shall be provided that a quality assurance agency audits the manufacturers quality assurance program and audits the production quality of products, in accordance with Section(5)(d)of Florida Rule 61G20-3.008.The quality assurance agency shall be approved by the Commission (or the building official when the report holder does not possess an approval by the Commission). 2.2 Evaluation to the high-velocity hurricane zone provisions in Section 1512 of the FBC, Building and Chapter 44 of the FBC, Residential is beyond the scope of this report. 3.0 PRODUCT USE The design and installation of the Boral Roofing concrete roof tiles shall be in accordance with the 2018 International Building Code and the 2018 International Residential Code, as applicable, as noted in ER412. From FBC, Building Section 1507.3 and FBC,Residential Section R905.3 states that the installation of the Boral Roofing concrete roof tiles -shall be in accordance with the requirements of the FRSAlTRI Florida High Wind Concrete and Clay Rooj*Tile Installation Manual, Sixth Edition where the Vw is determined in accordance with" FBC, Building Section 1609.3.1, FBC-Residential Section R301.2.13, or the recommendations of RAS 118, 119 or 120. Load combinations shall be in accordance with Sections 1605.2 or 1605.3 of the FBC. Building.as applicable. Design wind Page 7 of 7 BORAL . CONCRETE ROOF TILE i A -f y4 l a tl4 i �_� _.ram _ _--_. •��1..�—�-• - ,._.. �—.. yy IT € i I 1 ' li •� ,3 - SKU: 1 MPCS6493 Villa 900 - Mar m ciiade www.BoralRoof.com y RECEIVED JAN 2 1 2021 Permitting Dfaartment MIAMI-DADE COUNTY St. Lucie Cou P DUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) rile UolfW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION �-" �� Miami Florida 33175-2474 l//►Y 86)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) R IEW D miamidade¢ov/economy Boral Roofing LLC. CODE COMPLIANCE 7575 Irvine Center Drive,Suite 100 ST. LUCIE COUNTY Irvine,CA 92618 QiQCC SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal and BORAL MetalSeal HT LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 18-0502.03 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 19-0109.08 MIAMFDr4�eCOUNTY Expiration Date: 08/02/23 Approval Date: 02/07/19 Page l of 4 ROOFING COMPONENT APPROVAL Catel!orv: Roofing Sub-Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description BORAL TileSeal 36"x 36' rolls TAS 103 SBS self-adhering asphalt sheet material with a 36"x 72' rolls ASTM D1970 white glass re-enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. BORAL MetalSeal HT 36"x 36' rolls TAS 103 SBS self-adhering asphalt sheet material with a 36"x 72' rolls ASTM D1970 white glass re-enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. Boral Citadel Plus 36"x 72' rolls ASTM D1970 SBS self-adhering asphalt sheet material with a poly film-facer;for use as a mid-ply underlayment in sloped roof assemblies. MANUFACTURIGN LOCATION: 1. Brentwood,NH. 2. Houston,TX. EVIDENCE SUBMITTED: Test Aeencv Test Identifier Test Name/Report Date PRI Construction Materials OCF-356-02-04 ASTM D1623 07/25/18 Technologies,LLC. OCF-356-02-02 TAS 103 07/24/18 OCF-356-02-01 ASTM D1970 07/26/18 OCF424-02-04 ASTM D1623 07/25/18 OCF424-02-01 ASTM D1970 07/25/18 OCF424-02-03 TAS 103 07/25/18 Trinity ERD BRLRF-SC16810.11.17 ASTM D 1876 11/28/17 NOA No.: 19-0109.08 Expiration Date: 08/02/23 Approval Date: 02/07/19 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood,non-insulated Deck Description: 15/32"or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck,membrane adhered. Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4"head lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6" o.c.at the laps and two staggered rows 12" o.c.the field of the roll. Ply Sheet Apply one layer of Boral Citadel Plus over Base sheet as per current approval. (Optional): Membrane: One or more plies of BORAL TileSeal or BORAL MetalSeal HT Underlayment with a minimum 3"head lap and minimum 6"end lap.Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal or BORAL MetalSeal HT Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal or BORAL MetalSeal HT Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12"o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160,Mechanically Fastened Roof Tile,Metal Roofing, Wood Shake&Shingles,and Asphaltic Shingle assemblies. NOA No.: 19-0109.08 MAMMI COUNTY Expiration Date: 08/02/23 Approval Date: 02/07/19 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code.BORAL TileSeal and BORAL MetalSeal HT underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal and BORAL MetalSeal HT underlayment shall be applied to a smooth,clean and dry surface with deck free of irregularities. 4. BORAL TileSeal and BORAL MetalSeal HT underlayment shall not be applied over an existing roof membrane as a recover,but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal and BORAL MetalSeal HT underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal and BORAL MetalSeal HT underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal or BORAL MetalSeal HT underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal and BORAL MetalSeal HT underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal or BORAL MetalSeal HT underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal or BORAL MetalSeal HT underlayment is not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. For ridge applications,center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to overlap areas. 13. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6"piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal or BORAL MetalSeal HT underlayment shall be applied over the underlayment,and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility,and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below MIAMFWIDE COUNTY �FJM,WNPJ END OF THIS ACCEPTANCE MM NOA No.: 19-0109.08 MIAMFQADECouNTY Expiration Date: 08/02/23 Approval Date: 02/07/19 Page 4 of 4