Loading...
HomeMy WebLinkAboutProduct Approval (2) UL Evaluation Report UL ER2919-01 Issued: May 21, 2013 Revised: November 18, 2020 Visit UL, LLC's Product iQTm database for the status of this Rep UL Category Code: ULEZ CSI MasterFormat® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTIO Sub-level 2: 07 30 00—Steep Slope Roofing Sub-level 3: 07 31 00—Shingles and Shakes Sub-level 4: 07 31 13—Asphalt Shingles COMPANY: TAMKO BUILDING PRODUCTS LLC 198 FOUR STATES DRIVE GALENA, KANSAS 66739 F�IA_ (417) 624-6644 RECEIVED www.tamko.com JAN 2 1 1011 1. SUBJECT: Asphalt Shingles Permitting Department ELITE GLASS-SEAL, St. Lucie County HERITAGE, HERITAGE IR, HERITAGE PREMIUM, HERITAGE WOODGATE, HERITAGE VINTAGE, AND HERITAGE PROLINE TITAN XT HERITAGE VINTAGE 12 X 12 HIP AND RIDGE, 12-'/,X 12 HIP AND RIDGE,AND 12'/<X 12 HERITAGE HIP AND RIDGE IR HERITAGE VINTAGE STARTER 2. SCOPE OF EVALUATION ■2018, 2015, 2012, and 2009 International Building Code O(IBC) ■2018, 2015, 2012, and 2009 International Residential Code 0 (IRC) ■2020 Florida Building Code— Building ■2020 Florida Building Code— Residential ■ICC ES Acceptance Criteria for Quality Documentation (AC10) Physical Properties: TAMKO asphalt shingles covered under this Report have been tested for physical properties in accordance with ASTM D3462. Shingles tested in accordance with ASTM D3462 qualify for use under Section 1507.2.4 of the 2018 IBC, Section 1507.2.5 of the 2015, 2012, and 2009 IBC, Section 1507.2.5 of the 2020 Florida Building Code - Building, or Section R905.2.4 of the IRC and 2020 Florida Building Code - Residential. When installed on new construction in accordance with this report and the TAMKO Building Products LLC installation instructions, the shingles are a Class A roof covering. When the shingles are installed over existing roof coverings, the Class A fire classification is maintained. 5.1 Three-Tab Shingles— Elite Glass-Seal: Elite Glass-Seal shingles are three-tab shingles manufactured with a single fiberglass mat, coated on both sides with asphalt, and surfaced on the weather-exposed side with mineral granules. The shingles are self-sealing and have beads of thermal-tab sealing adhesive above the shingle butt on the weather side. See Table 2 for product dimensions and manufacturing locations. 5.2 Laminated Shingles—Heritage, Heritage IR, Heritage Premium, Heritage Woodgate, Heritage Vintage, and Heritage Proline Titan XT: Heritage, Heritage IR, Heritage Premium, Heritage Woodgate, Heritage Vintage, and Heritage Proline Titan XT shingles are laminated shingles manufactured with a double layer of fiberglass mats coated with asphalt on all sides, and surfaced on the weather-exposed side with mineral granules. See Table 3, Table 4, Table 5, Table 6, Table 7, Table 10, and Table 13 for product dimensions and manufacturing locations. 5.3 Hip & Ridge Shingles — 12'/4 X 12 Hip and Ridge, Heritage Vintage 12 X 12 Hip and Ridge, 12=/4 X 12 Heritage Hip and Ridge IR: Hip and Ridge are prefabricated hip and ridge shingles available as 12-'/4 X 12 Hip and Ridge and 12-'/4 x 12 Heritage Hip and Ridge IR. Heritage Vintage Hip and Ridge are prefabricated hip and ridge shingles available as 12 X 12 Hip and Ridge. As an alternative, Elite Glass-Seal shingles are cut into three 12-'/4 inch by 12-inch (305 mm by 305 mm) hip and ridge shingles. See Table 8, Table 9, and Table 11 for product dimensions and manufacturing locations. 6. INSTALLATION TAMKO asphalt shingles must be installed in accordance with the applicable code, this report and the manufacturer's published installation instructions. The shingles must be installed in accordance with Section 1507.2 of the IBC and 2020 Florida Building Code - Building, or Section R905.2 of the IRC and 2020 Florida Building Code - Residential, as applicable, except as noted in this report. The manufacturer's published installation instructions must be available at all times on the jobsite during installation. Minimum roof slopes must be 2:12 (16.67% slope) for the three-tab shingles described under 5.1 of this Report and for the laminated shingles described under 5.2 of this Report. Page 3 of 19 6.3.2 Laminated Shingles — Heritage, Heritage IR, Heritage Premium, Heritage Woodgate, and Heritage Proline XT: For roof slopes 2:12 up to but less than 21:12 (16.67% to 175% slope), each shingle must be fastened to the roof deck using a minimum of four fasteners, spaced as shown in Tables 3, 4, 5, 6, 10, and 13. For roof slopes equal to or greater than 21:12 (175% slope), six fasteners must be used, spaced as shown in Tables 3, 5, 6, 10, and Table 13. Maximum exposure to the weather must be 5-% inches (143 mm). In colder climates or wind regions where it is questionable whether the thermal-sealing adhesive will activate to seal the shingles, the shingles can be hand-sealed. Four evenly spaced 1-inch diameter(25.4 mm)spots of cement should be placed under the exposed portion of the shingle, approximately 1 inch (76 mm) above the butt edge. 6.3 3Laminated Shingles— Heritage Vintage: For roof slopes 2:12 up to but less than 21:12 (16.67% to 175% slope), each shingle must be fastened to the roof deck using a minimum of five fasteners, spaced as shown in Table 7. For roof slopes equal to or greater than 21:12 (175% slope), nine fasteners must be used, spaced as shown in Table 7. Fasteners must be located 6 and 11-112 inches (152 and 292 mm) above the butt edge of the shingles. Maximum exposure to the weather must be 5 inches (127 mm). In colder climates or wind regions where it is questionable whether the thermal-sealing adhesive will activate to seal the shingles, the shingles must be hand-sealed. Four evenly spaced 1-inch diameter(25.4 mm)spots of cement should be placed under the exposed portion of the shingle, approximately 1 inch (127 mm) above the butt edge. 6.4 Valley Construction and Other Flashing: Valleys must consist of woven, open valley or closed-cut construction and must be flashed in accordance with Section 1507.2.8.2 of the 2018 IBC, and Section 1507.2.9.2 of the 2020 Florida Building Code - Building, 2015, 2012, and 2009 IBC or Section R905.2.8.2 of the IRC and 2020 Florida Building Code - Residential. Other flashings must be in accordance with Sections 1503.2 and 1507.2.8 of 2020 Florida Building Code - Building, 2018 IBC, Section 1507.2.9 of the 2015, 2012, and 2009 IBC, or Section R903.2 and Section R905.2.8 of the IRC and 2020 Florida Building Code - Residential, as applicable. Page 5 of 19 7.5 Fasteners: Fasteners must be minimum No. 12 gage [0.105 inch (2.7 mm)], %-inch diameter head (9.5 mm), galvanized, stainless steel, aluminum or copper corrosion-resistance nails. Fasteners must be of sufficient length to penetrate into the sheathing 3/4-inch (19.1 mm), or through the sheathing, where the sheathing is less than 3/4-inch (19.1 mm)thick. Fasteners must be compliant with ASTM F1667. 7.6 Asphalt Cement: Asphalt cement must comply with ASTM D4586, Type I, Class I. 8. CONDITIONS OF USE The TAMKO Asphalt Shingles described in this Report comply with, or are suitable alternatives to, what is specified in those codes listed in Section 2 of this Report, subject to the following conditions: 8.1 Materials and methods of installation shall comply with this Report and the manufacturer's published installation instructions. In the event of a conflict between the installation instructions and this Report, this Report governs. 8.2 The products are manufactured at the locations listed in Table 1 of this Report under the UL LLC Classification and Follow-Up Service Program, which includes regular audits in accordance with quality elements of ICC-ES Acceptance Criteria for Quality Documentation, AC10. 8.3 See UL Product iQm database for Prepared Roof-Covering Materials (TFWZ). 9. SUPPORTING EVIDENCE 9.1 Manufacturer's descriptive product literature, including installation instructions. 9.2 See UL Product iQTm database for the following: 9.2.1 UL test reports and Classification in accordance with ANSI/UL 790, Class A and UL Subject 2375 for Roof-Covering Materials (TFWZ). 9.2.2 UL test reports and Classification in accordance with ASTM D3462 for Prepared Roof- Covering Materials (TFWZ). 9.2.3 UL test reports and Classification in accordance with ASTM D7158, Class H for Prepared Roof-Covering Materials (TGAH). 9.2.4 UL test reports and Classification in accordance with ASTM D3161, Class F Prepared Roof-Covering Materials (TFWZ). 9.3 Quality Documentation in accordance with ICC-ES Acceptance Criteria for Quality Documentation, AC10. 10. IDENTIFICATION TAMKO asphalt shingles described in this Evaluation Report are identified by a marking on each package bearing the report holder's name (TAMKO Building Products LLC), the plant identification, the product name, the UL Listing/Classification Mark and the evaluation report number UL ER2919-01. The validity of this Evaluation Report is contingent upon this identification appearing on the package. Page 7 of 19 Table 2—Elite Glass-Seal Dimensions: 12-1/4"x 36" ------------------------ ----------------------------------------------------------------------------------------- Plant Location(s): Frederick, Joplin -------------------------T----------------------------------------------------------------------------------------- For slopes 2:12 up to but less than 21:12 NAILS Fastening Pattern: Na ------------------------ - 6-71W &V - - - - - - �4-- --- --- --- --- --- --- ------------------ -----------------------------M..................... . ............................... Butt Edge ------------------------ ----------------------------------------------------------------------------------------- For slopes equal to or greater than 21:12 NAILS Fastening Pattern: .6-------------------- .............. ... ------ Naling- .. ....................................................... ..............W._........_._.__ 1 w 6-7/8 11 Area ----------------------------------------------------------------------­------------------------------ 5-Mil Butt Edge Page 9 of 19 Table 4—Heritage Dimensions: 13-%"x 39-3/8" ------------------------- ----------------------------------------------------------------------------------------- Plant Location(s): Tuscaloosa ------------------------ --------------------------------------------------------- For slopes 2:12 up to but less than 21:12 1 12-1/2' —o- -12-W8'—►, 12-1/2r PAINT PREFERRED FASTENER LOCATIONS LINE,,"" 7-718" ---- -- ----- -- --- }NAIL ZONE 6-1/8" EEDpGGEEO' Fastening Pattern: BOND ON EXPOSURE r ACCEPTABLE FASTENER LOCATION DO NOT FASTEN ALONG EDGE OF COMMON BOND — --- - — PREFERRED FASTENER LOCATION --------------------------------------------- ------------------------------------------------------------------ For slopes equal to or greater than 21:12 NAL ZONE FASTENERS COMMON BOND Fastening Pattern: 6-1 EXPOSURE 5-"* Page 11 of 19 Table 7—Heritage Vintage Dimensions: 17-1/2"x 40" ------------------------- ----------------------------------------------------------------------------------------- Plant Location(s): Phillipsburg ------------------------T- - - - -------------------------------------------------------- For slopes 2:12 up to but less than 21:12 �o• n EXP— Notcl Easftrbm - - - - - - - - - - - - rl Fastening Pattern: S. Exposure 41lC 41/C "94M' �-JONC--i -ta3fa•� - --------------------------------------------------------- For slopes equal to or greater than 21:12 40• "OICIM Fasteners s• 1 Zone Fastening Pattern: T — —� - - — — — — — — — — — — — 5. Apply under each tab 1'diameter asphalt adhesive cement Page 13 of 19 Table 9—12-1/4X 12 Hip and Ridge Dimensions: 12-1/4"x 12" -------------------------------------------------- ------------------------------------------------------- Plant Location(s): Frederick, Joplin - ------------------------r--------------------------------------------------------------------------------- Nails 1 in. FasteningPattern: T 5 5/8" Exposure 12" Page 15 of 19 Table 11 Heritage Hip and Ridge IR Dimensions: 12-%"x 12" ------------------------- ----------------------------------------------------------------------------------------- Plant Location(s): Joplin ------------------------------------------------------------------------------------------------------------------ Nails Fastening Pattern: 12'/.' t in-� �1 in_ 5 1/8" 5 5/8' Exposum 12" Table 12 Heritage Vintage Starter 36.00n. ±11W N Page 17 of 19 ©2020 UL LLC This UL Evaluation Report is not an endorsement or recommendation for use of the subject and/or product described herein. This report is not the UL Listing or UL Classification Report that covers the subject product. The subject product's UL Listing or UL Classification is covered under a separate UL Report. UL disclaims all representations and warranties whether express or implied, with respect to this report and the subject or product described herein. Contents of this report may be based on data that has been generated by laboratories other than UL that are accredited as complying with ISO/IEC Standard17025 by the International Accreditation Service (IAS) or by any other accreditation body that is a signatory to the International Laboratory Accreditation Cooperation (ILAC) Mutual Recognition Arrangement (MRA). The scope of the laboratory's accreditation shall include the specific type of testing covered in the test report. As the accuracy of any non-UL data is the responsibility of the accredited laboratory, UL does not accept responsibility for the accuracy of this data. U` Page 19 of 19