Loading...
HomeMy WebLinkAboutHealth Dept Report APPLICATION #:AP1397590 STATE OF FLORIDA 1 ` PERMIT #:56-SF-1923683 DEPARTMENT OF HEALTH // (J DOCUMENT #:FI 1374935 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM ,y CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:01/25/2019 FEE PAID:515.00 RECEIPT #:56-PID-3857865 APPLICANT: Susan Beckman AGENT: MICHAEL STUHR (ASHTON SEPTIC TANKS, INC.) PROPERTY ADDRESS: 7816 Saddlebrook Dr Port Saint Lucie, FL 34986 LOT: 5 BLOCK: SUBDIVISION: Sabal Creek I ID#: 3321-501-0005-000-8 CHECKED [X3 ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ 1 [013 TANK SIZE [11 1090.00 [21 [ 3 [27) SURFACE WATER FT [ ] (023 TANK MATERIAL Polypropylene [ 1 (28] DITCHES FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS 100 FT [ 3 (041 MULTI-CHAMBERED [ Y N ] [ 3 1301 PUBLIC WELLS FT ( ] [05) OUTLET FILTER Polylok PL-68 [ 1 [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1 70-143-11DC4 2. [ 3 [321 POTABLE WATER 73 FT [ ] (071 WATERTIGHT [ 1 (331 BUILDING FOUNDATIONS 7 FT [ ] [081 LEVEL [ 1 [341 PROPERTY LINES 37 FT ( ] [091 DEPTH TO LID [ ] [35) OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1] 679.2 [2) SQFT ( ) [361 DRAINFIELD COVER [ ] (111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 6.00 2. [ 1 (381 SLOPES [ 1 [131 DRAINLINE SEPARATION [ ] [39) STABILIZATION 02/25/2020 [ 1 (141 DRAINLINE SLOPE [ 1 1151 DEPTH OF COVER ADDITIONAL INFORMATION [ 1 [161 ELEVATION [ ABOVE / BELOW )BM 2.00 [ ] [401 UNOBSTRUCTED AREA [ 1 [171 SYSTEM LOCATION [ ) [411 STORMWATER RUNOFF [ 1 (181 DOSING PUMPS ( 1 [421 ALARMS [ 3 [191 AGGREGATE SIZE [ 3 [431 MAINTENANCE AGREEMENT ( 1 [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [211 AGGREGATE DEPTH ( 3 [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL ( 1 [461 FINAL SITE GRADING [ 1 [221 FILL AMOUNT [ 1 (473 CONTRACTOR MICHAEL W STUHR (ASHTO [ 1 (231 FILL TEXTURE ( 1 (48] OTHER [ 1 (241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] (491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ 1 [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED ron ENV St. Lucie CHD DATE: 12/13/2019 DISAPPROVED 1' En ntal specialist 11 J Ingram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ): St. Lucie CHD DATE: 02/25/2020 nVironmental Special I Brian J Ingram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1397590 EID1923633 APPLICATION #:AP1397590 STATE OF FLORIDA PERMIT #:56-SF-1923683 DEPARTMENT OF HEALTH DOCUMENT #:FI 1374935 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM 0.,ox, CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID: 01/25/2019 9 FEE PAID:515.00 RECEIPT #:56-PID-3857865 Violation Number Comment Comments The system is sized for 3 bedrooms with a maximum occupancy of 6 persons(2 per bedroom),for a total estimated flow of 400 gpd. New ST, filter,and 6x10 long BED DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final inspection for mound system and final site grading. Well inspected at construction inspection. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1397590 E101923683